As we defined self load while defining EQ parameter, so I think it would not be define again beam member weight, because it will unnecessarily increase seismic weight and thereby hamper the structural output.
@rmathew3595 Жыл бұрын
Correct.
@engineerashfaque4 жыл бұрын
You already considered selfweight which covers beam/ slab/column self weights, then why did you add again beam & slab weight?
@PradeepMYeole4 жыл бұрын
Good explanation
@civilengineeringbyshravan95964 жыл бұрын
Thanks 😊
@dr.rajeevanb34714 жыл бұрын
I think you need not add weight of beam as member weight. That will be already calculated by the self weight option. The member weight is for including the partition loads. Right?
@sayandas89143 жыл бұрын
Yes
@ManojKumar-wp3bx2 жыл бұрын
We consider the floor load 3.5 kn..while slab dead load already takes and assigned in self weight ..so we should take only 1 to 1.5 kn floor load that is its finishing load..m i right sir
@faizanuddin92724 ай бұрын
Sir seismic load is consider positive?
@civilengineeringbyshravan95964 ай бұрын
I was considered EQx case only you can take EQy also by considering another load case
@jintamolp.y.22303 жыл бұрын
Since member weights are added here whether it is needed to add self weight again in DL option
@nikolastheologou70815 жыл бұрын
Thanks a lot for your video! Why Did you reduce the damping ratio from 5 to 0.05? The five in the beginning did not meant five percent?
@civilengineeringbyshravan95965 жыл бұрын
If we are not consider 0.05 it will show you error message as damping ratio limit exceeding
@pujajha99764 жыл бұрын
kzbin.info/www/bejne/mqKviGWAdrZrers
@MG-ny1ue3 жыл бұрын
No need to calculate dead weight of concrete for sismic analysis. It calculates automatically. Instead of calculating dead weight of beam , calculate dead weight of wall resting on beam
@civilengineering34383 жыл бұрын
Sir you have applied member load in E.Q analysis to all beam but you have not applied floor load to all plates which you have generated. pl clarify only we have to generate the floor load not applied to its plate elemets?
@sugatmohod64162 жыл бұрын
brother do you have something on " Seismic Analysis of Silo"
@omgomase844 жыл бұрын
Sir please make a correction while defining a floor weights pressure=(DL+0.25/0.5 LL) kN/m2. here DL=Self weight of slab+superimposed DL.
@barnabusgurung54994 жыл бұрын
Can you analysis and design a rcc building of a seismic region
@civilengineeringbyshravan95964 жыл бұрын
Please follow this video 👍🏻 kzbin.info/www/bejne/fp2Tl6OFZt-rbsk
@shrutirawat123454 жыл бұрын
Ppppplppppppppppppppp
@rahimsafi62754 жыл бұрын
we do not use - sign for load in seismic analysis
@ManojKumar-wp3bx2 жыл бұрын
We take uni load 2.5 kn and assigned for beam ...while dead load already taken..why in seismic load we again assigned it..kindly clear
@shaiksharmila54668 ай бұрын
@Sir i got 2 errors by following u r video how can i rectify the errors
@syedmuzaffarihsan19604 жыл бұрын
After seismic analysis can I directly go to design option for rcc design
@pujajha99764 жыл бұрын
kzbin.info/www/bejne/mqKviGWAdrZrers
@pujajha99764 жыл бұрын
kzbin.info/www/bejne/mqKviGWAdrZrers
@Souvik626744 жыл бұрын
Why do you add member weight and floor weight ??
@sadanandaswamy69183 жыл бұрын
It would have been better if you had meshed the slab according to the column spacing.
@civilengineeringbyshravan95963 жыл бұрын
ok
@btb-bengaltrekkerbubun16783 жыл бұрын
Why are you not considering the weight of the column?
@puneetgosain39225 жыл бұрын
Sir, What is Damping ratio?
@puneetgosain39225 жыл бұрын
I want to ask how you choose the damping ratio( .05) is it depend on type of material
@civilengineeringbyshravan95965 жыл бұрын
Damping is a phenomenon that makes any vibrating body/structure to decay in amplitude of motion gradually by means of energy dissipation through various mechanisms. For the building generally we will assume 5% vibrations
@puneetgosain39225 жыл бұрын
@@civilengineeringbyshravan9596 ok sir
@yogeshprajapati33195 жыл бұрын
Error 1893 load cases must be defined before any other load case ....what is the solutio
@civilengineeringbyshravan95965 жыл бұрын
Yes you need define load case initially before applying
@rahimsafi62754 жыл бұрын
you should define seismic load before any other load such as dead or live load
@civilengineeringbyshravan95964 жыл бұрын
Yes
@nishantmeshram21043 жыл бұрын
@@civilengineeringbyshravan9596 SIR AFTER DEFINATION ALSO ERROR IS COMING
@nishantmeshram21043 жыл бұрын
PLEASE RACTIFY MY DOUBT
@oscarvaron50243 жыл бұрын
Hey my friend ¿dimensions of columns and beams in concrete material?meter
@manisingla38605 жыл бұрын
sir mere softwere m sesimic load define nhi ho rha, creation failed ara h ,,,any solution