thats made me look 100% right in an disgruntled converstaion over pilz verry clear and easy to under stand for the aprentice only thing i would say is use orange cable for controll identification as yellow is a no no thank you
@marijngade54033 жыл бұрын
Would this setup not require 2 master relays in series to consider it full safe? This way the relay could get stuck open and the intire safety part is useless.
@pnswg012 жыл бұрын
In the schematic section, the wires goes to the wrong pins but the audio is true. Possibly because the software wouldn't allow you to draw the lines to the correct pins. Good explanation anyway.
@Jatin____Sharma4 жыл бұрын
Awesome, today I learn about a new device😍
@judeclark1424 жыл бұрын
thank you so much i finally understand safty relays
@kevin008612 жыл бұрын
Thank you Sir for spreading your knowldge
@EASYPLCTRAINING2 жыл бұрын
Welcome dear
@The11noodle3 жыл бұрын
Brilliantly explained
@maintenancegc65682 жыл бұрын
Clear Explanation.
@syedhassanali9330 Жыл бұрын
Thank you very much sir very informative video
@monroestrike43784 жыл бұрын
Perfect. Simple and well explained!
@alfredaxax10 ай бұрын
nice lecture
@baskarchandrakasan9954 жыл бұрын
Excellent teaching sir.
@irwinjimenez Жыл бұрын
Great job. Very useful video. Thank you.
@xubairahmed9512 жыл бұрын
amazing work
@afrid-li8ke2 жыл бұрын
Great and well explained
@arunrajendran6743 жыл бұрын
Super explanation... Explain pilz X3 relay also?
@EASYPLCTRAINING3 жыл бұрын
Stay connected coming soon
@ismatsumarjan2902 жыл бұрын
Thanks for your information
@AEGroupNL3 ай бұрын
You can put 100K in the thumbnail :) thanks for the video!
@chappagiridhar51094 жыл бұрын
Nice explanation sir👍👍👍
@vasanthakumar81674 жыл бұрын
Good explanation
@showshocka3k3 жыл бұрын
Love it! Controls!!
@kencooley55894 жыл бұрын
I have a question. If one of the channels are not closed when the on pulse to the start channel is made, do you have to turn off both channels to attempt to start it again? So if channel 1 is false and channel 2 is true. Start signal is received. Must channel 2 be made false before another start signal can be made true?
@EASYPLCTRAINING4 жыл бұрын
Yes exactly we have to reset both channels ..... but in some relays we jut have to reset only one faulty channel .... I think It depends on the model of the Safety relay
@user-saber-yasser.2 жыл бұрын
thank you very much 🌹good explanation
@hatemzaatra58944 жыл бұрын
Great video
@Bigmallone4 жыл бұрын
great work it was very useful for me
@cathleyamaesantos45574 жыл бұрын
Nice one
@azharbarmare6847 Жыл бұрын
Sir I had a question in my case relay is starting but after some time but it is continuously asking to reset and sometime reset button also dnt work...
@shahbazarain94884 жыл бұрын
Amazing
@devpatel3619 ай бұрын
Do I compulsorily have to use a Contactor at the end? If not, do i attach 13-14. 23-24 directly to the actuator ? Why use contactor, if we are using relay for the saftey ? Thank you for the video ! :))
@glennrodrigues71113 жыл бұрын
Thank you sir well explained
@RAMSINGH-06 ай бұрын
Thankyou ❤
@mantunaik97987 ай бұрын
How to take feedback from this safety relay to plc for alarm generations
@aminizza14503 жыл бұрын
Thank's very usefull
@manjunathamanju62044 жыл бұрын
Good explanation thank you so much
@shanefrank32812 жыл бұрын
Great video! I have been having trouble understanding safety relays from the data sheets and this helps. But I was wondering if you had only wired the contactor to only 13-14 (and not series 13-14 and 23-24) would only the red button connected to S11-S12 turn off the contactor? So S11-S12 safety input only controls 13-14 and S21-S22 only controls 23-24. Is that correct?
@GhostHostMemories Жыл бұрын
no. 13/14 and 23/24 are mechanically linked, and not tied to a specific input
@johnrece66223 жыл бұрын
So this relay doesn't have a reset option? So you will have to turn off channel 1 and 2 to restart it?
@TheThippu4 жыл бұрын
Excellent i have learned new thing today, Is it same as Siemens Sirius safety relay with more chancels
@Jarito19034 жыл бұрын
Great video, thanks. Keep on the hard work
@Love__yu4 жыл бұрын
The contactor is 24 v?, how can connect a 220v contactor
@MenAreBrave072 жыл бұрын
Using relay.
@irwinjimenez Жыл бұрын
220v can go to COM terminal, NO contact goes to the contactor coil. Safety relay energizes the 24vdc ice cube relay to turn on the 220v.
@phanduyautomation37373 жыл бұрын
perfect. good
@antoniomondragongonzalez16928 ай бұрын
Excelente
@danghoangvinh95123 жыл бұрын
Perfect. but i have a question. Why do you have to wiring both 2 NO 13-14 and 23-24 to contactor instead of only 1 (13-14 or 23-24 to Contactor) .Thanks you about this video!
@EASYPLCTRAINING3 жыл бұрын
You can use single contact also , just as an example I looped both auxiliaries . These contacts are also used to give signals to other safety relays ... means if you have seen safety relays working in loops
@danghoangvinh95123 жыл бұрын
@@EASYPLCTRAINING thanks you!!
@cascadeanalog3203 жыл бұрын
Thank you Sir
@showshocka3k3 жыл бұрын
How could one even attempt to give this simple tutorial thumbs down?
@danschumacher54272 жыл бұрын
Watch me
@ajayrawat95252 жыл бұрын
sir PNOZ S3 have same function or different?
@EASYPLCTRAINING2 жыл бұрын
Same function, but I thing It have 4 channels to monitor the safety loops
@balachanderbalachander69594 жыл бұрын
nice sir. add other company relays also. sick, schmuller.
@EASYPLCTRAINING4 жыл бұрын
Almost similar .... but must go through wiring diagram
@ethan0732 жыл бұрын
THANK YOU
@athilaldurry58804 жыл бұрын
Many thanks
@mikeadler434 Жыл бұрын
👍👍
@goriparthisrikanth6463 жыл бұрын
Sir video prepared in three phase motor runs in single phase supply okk
@goriparthisrikanth6463 жыл бұрын
Plz reply
@EASYPLCTRAINING3 жыл бұрын
Yes three phase motor , running on single phase 220v
@goriparthisrikanth6463 жыл бұрын
@@EASYPLCTRAINING plz video prepared sir
@ThePengue2 жыл бұрын
Why to reset the safety relay you have to push both red button?
@sebutir_embun67034 жыл бұрын
thanks bro
@asifislam73762 жыл бұрын
Neutral A2..you draw black wire in s12..channel 1 s21,s22..but where u have drawn red push button? 14 and s11..how!! One red push button should be in ch1 (s22,s22) and another one in ch2 (s11,s12) Am k right? Pardon..
@Idrathernot.3 жыл бұрын
Very beginner here; what does K1 and K2 mean?
@EASYPLCTRAINING3 жыл бұрын
k1 and k2 are the internal relays of the safety device
@jwerry584 жыл бұрын
Can you provide what type the 1 green button and 2 red buttons? Momentary or Latch? Red N.C.? Green N.O.?
@MenAreBrave072 жыл бұрын
He said it need pulse signal which means momentary.
@foxxmulder75243 жыл бұрын
This is incorrect:Channel 1 and channel 2 is not wired using single pole normally closed contacts. You must use double pole force guided contacts. going to both channels simultaneously.
@mosesmoyes33013 жыл бұрын
Piloje
@AndrewBambiliano Жыл бұрын
Sorry but your bad wiring diagram made me so confused
@pogssss5058 Жыл бұрын
Thanks for this sir,
@박정훈지훈3 жыл бұрын
Can you provide what type the 1 green button and 2 red buttons? Momentary or Latch? Red N.C.? Green N.O.?
@EASYPLCTRAINING3 жыл бұрын
All momentary button .... green NO .... and red NC push buttons