EBM Papst RG-130 Blower Motor - Repair (Ep. 71)

  Рет қаралды 12,792

Trevor's Bench

Trevor's Bench

Күн бұрын

Пікірлер: 25
@craigm.9070
@craigm.9070 3 жыл бұрын
Awesome troubleshooting and operational check(s) of blower PWM parameters. Again, like you mentioned, terrible shame the customer had to replace a pricey component due to a less than desirable capacitor mounting during circuit board buildup. At least now, the customer has a known good replacement. Thank you for taking the time to make this video!
@Sharklicker2000
@Sharklicker2000 3 жыл бұрын
Dude! I love you!! It's 15 degrees in Seattle and we've had no heat or hot water for 10 days. You are allowing me to fix this near exact ebm papst motor pcb. Thank you thank you thank you. My motor is backordered nationwide until February...hot shower tonight!! 72 virgins in heaven for you.😂🤣😂🤣
@TrevorsBench
@TrevorsBench 3 жыл бұрын
Awesome, great to hear this is helpful. Stay warm
@justin2588
@justin2588 2 жыл бұрын
I have had two similar motors to replace one that wouldn't spin. When they arrive and I apply 110v they do nothing. They don't have a plug on the signal end when they are installed, they're supposed to just do %100. Any ideas? RG148
@TrevorsBench
@TrevorsBench 2 жыл бұрын
Confirm they are getting power when they are to run. Aside from the fuse, there's no way of telling without confirming power is getting to all the circuits that need it. These are 3 phase motors with hall effect sensors for speed feedback. They can be a bit complicated.
@rc5037
@rc5037 3 жыл бұрын
Hi, Thanks for the video. I couldn't see how you changed the parameters for the PWM. Did you changed the voltage maintaining the 1 kHz?
@TrevorsBench
@TrevorsBench 3 жыл бұрын
I changed the duty cycle of the square wave of the sig gen
@wesleygt40
@wesleygt40 Жыл бұрын
Thanks for the video it helped a lot. So I wanted to know where I can get the diagram of the board?
@paulericn.mouafo6610
@paulericn.mouafo6610 2 жыл бұрын
Thank so much.. i'm facing similar issue with my boiler blower... it doesn't start at all and need a check..
@ogneanmihai8676
@ogneanmihai8676 Жыл бұрын
Can i start that motor with a 3 phase controller?
@dongyuanfan4909
@dongyuanfan4909 3 жыл бұрын
Great video👍
@Firatsevimli44
@Firatsevimli44 2 жыл бұрын
Nice Video Thanks 👍👍👍👍
@fredkester6130
@fredkester6130 Жыл бұрын
Very usefull, thnx a lot!
@michaels3835
@michaels3835 2 жыл бұрын
Just took one apart here. Slightly different model but the capacitor was floating around inside. Unfortunately, it probably got into the fan area. the fan is busted up. I don't have the sleeve you had. It was probably broken or spun off. Now, the big problem is finding a replacement fan. Anyone have any ideas? All I am finding online are replacement motors such as your friend had.
@agermats
@agermats 11 ай бұрын
Sounds like exactly the same problem I have! Did you ever find the replacement fan and the way to take it off?
@electroniys
@electroniys 3 жыл бұрын
Wher is PWM control value?
@agermats
@agermats 11 ай бұрын
Just FYI it can run without that cap. I had the same issue with the cap it fell completely off but it still ran.
@agermats
@agermats 11 ай бұрын
The issue I had was the blower fan bottom side got delaminated and came off breaking in 4 pieces and getting stuck. I have no idea how to remove it as it doesn't have any spring holding it and it seems it was just press fit onto the shaft.
@adil123eei
@adil123eei Жыл бұрын
Hi I need some help to build a PWM driver to run a boiler
@abrahamfranciscolopezcartagena
@abrahamfranciscolopezcartagena 2 жыл бұрын
Mi estimado soy chileno y tengo un problema con el modelo a3g800-05-71 Como puedo pedir el reemplazo de la placa ya que aquí en Chile no encontramos las partes posiblemente dañadas Te agradezco mucho tía comentarios atte Abraham López
@sametalici877
@sametalici877 Жыл бұрын
Thanks for share
@neurodx65
@neurodx65 2 жыл бұрын
Did your customer pick up the fan? otherwise I will buy it .
@TrevorsBench
@TrevorsBench 2 жыл бұрын
Yes, it's back in service
@uknokianut
@uknokianut 2 жыл бұрын
Ive just had to order a new fan for a commercial customer for a Remeha Gas 210 pro , it's nearly £2000 . To think it could simply be a £2 part,
@sametalici877
@sametalici877 Жыл бұрын
Everytime it is not related to capacitor this blowers can be stuck and short circuit because of fluid contact in this situation cost increases and also experience is important for repair
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 62 МЛН
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 18 МЛН
Арыстанның айқасы, Тәуіржанның шайқасы!
25:51
QosLike / ҚосЛайк / Косылайық
Рет қаралды 700 М.
The most useful tool ever for electronics repairs - (PWJ212)
13:09
Play with Junk
Рет қаралды 277 М.
simple way to make mini heating stove.free energy for your home!awesome
18:09
Pulling apart fan motor EBMpapst A4350 Part 2
4:46
Simplicity Garage
Рет қаралды 36 М.
ZIEHL ABEGG EC BLUE FAN MOTOR  | TROUBLESHOOT AND TEST
13:56
D2D NY Real World HVAC Simplified
Рет қаралды 4,9 М.
I Built an Atmosphere Powered Battery..
13:00
Concept Crafted Creations
Рет қаралды 832 М.
A long time shoemaker showed me this secret! great tool.
9:19
Creation Secret
Рет қаралды 6 М.
Check out this GRAVITY-Powered Electric GENERATOR!!!
12:34
EL ANGELITO
Рет қаралды 340 М.