This is the perfect situation for an Electric Tankless Water Heater 🔥🔥
I'm building my dream Home Office with Kitchenette & Full Bathroom 😃
And I didn't want to waste space for a big hot water tank, or waste the money heating water continuously on a space that won't be used that often.
I chose to install a Thermomate 18KW Electric Tankless Water Heater - amzn.to/3s0guPA
This unit will heat 2.3 gallons per minute from 52 degree water to 105 degrees.
Here are a few things that I recommend you should think about before purchasing an Electric Tank Water Heater :
1. Power supply, do you have the room for the breakers needed. This 18kw unit takes 2 - double 40amp breakers, the 27kw needs 3!
2. What kind of gpm do you need? For a typical shower system, 2 gpm is needed. And thats a low volume shower....If you are used to full massage shower then be sure to buy the bigger unit (27kw)
3. 8 AWG wire is not cheap.....A 125ft roll of 8/2 wire was almost $300 😐
I hope this video helps you out in deciding if this is a good solution for your space.
For more help & support, Enroll in the DIY GEEK MEMBERSHIP (one-time payment, that's it 👊) You'll get all of my courses bundled together along with this Home office build. bathroomremodeling.teachable....
🛁Tub/Shower Bathroom Remodel Course in 7 Days or Less - bit.ly/3ODNwfV
🚿Ulitmate Curbless Shower Course - bit.ly/46Cyfn5
💫 3 Day Tiled Shower Course - bit.ly/3ZFSCgV
🌟 Basement Bathroom Course - bit.ly/475PgHa
🛀 Tub/Shower Replacement Course - bit.ly/44okO8r
✨ Custom Tiled Shower Course - bit.ly/3ELCBw1
🔥 Custom Glass Enclosure Course - bit.ly/46SQFRm
💥 Converting a Tub to Shower Course - bit.ly/3t1RszQ
🔷 Tile Shower Repair Course - bit.ly/3t9vUBj
🎬Chapters
0:00 Thermometer Tankless Water Heaters
0:49 Which one to choose?
3:30 Electrical Line Supply
4:16 Water Supply Connections
5:17 Placement of Heater
6:26 Electrical Connections
9:54 Testing & Review
#diy #plumbing #electrical #bathroomremodel #homeoffice #garage #waterheater #bathroomdesign #bathroomremodelingteacher #homeimprovement
* Bathroom Remodeling & construction is inherently dangerous. Please use proper safety equipment and care with the use of tools and materials. For full disclaimer please review: docs.google.com/document/d/1y...

Пікірлер: 29
@fishynut8252
@fishynut8252 9 ай бұрын
LOL - Northern Hemisphere! Gave me a chuckle. Just yankin your chain here ..... The entire US in the Northern Hemisphere, but you are at a more northern latitude than most.
@BathroomRemodelingTeacher
@BathroomRemodelingTeacher 9 ай бұрын
Pennsylvania schools 😆
@windego40
@windego40 5 ай бұрын
Just got it in yesterday and replaced my old one that was leaking, worked great!
@joshuawhite9725
@joshuawhite9725 9 ай бұрын
you should always mark those white wires with black tape when using them as a hot.
@BathroomRemodelingTeacher
@BathroomRemodelingTeacher 9 ай бұрын
Yeah
@joshuawhite9725
@joshuawhite9725 9 ай бұрын
I was an electrician before I started tile work lol. Love your work and channel though!
@feeblewrk5788
@feeblewrk5788 9 ай бұрын
Yes always when using white as an identified conductor.
@thenexthobby
@thenexthobby 9 ай бұрын
These tend to be popular in countries not limited by 240v supplies … that’s a LOT of copper here to unfortunately need run.
@codymercado5253
@codymercado5253 25 күн бұрын
Great vid!!
@thermomate
@thermomate 8 ай бұрын
Great video! Thank you for sharing your knowledge and expertise with us. I'm so grateful for your hard work. Can I share it on my KZbin?
@mackfisher4487
@mackfisher4487 5 ай бұрын
NEC 20/23 code cycle you You'll need GFCI breakers (more money too).
@christinacampbell1547
@christinacampbell1547 4 ай бұрын
Hey im in Pittsburgh do i need to add ground ground wire for this???
@user-qd2cd8ft6d
@user-qd2cd8ft6d 5 ай бұрын
Hi, are the electric tankless water heaters quiet? I'm looking to change my gas water heater which is loud because of the vent motor...
@murphydowning2495
@murphydowning2495 2 ай бұрын
Never heard of using the neutral as a hot, but would be cheaper than buying the 8/3 which is what I thought I needed. Getting a consultation with my inspector this coming week to see what he says about that... Does anyone know where I'd find a guideline to this in the NFPA codebook?
@kaseyc5078
@kaseyc5078 8 ай бұрын
Wonder why it’s 2 40amp breakers on separate lines instead of higher gauge wire in a 80 or 90 amp breaker
@XC-Z-cv8qw
@XC-Z-cv8qw 5 ай бұрын
Because most electric companies don't supply 80-90 amps to a residential customer, usually only around 40A. So you need to use electric water heaters "in-tandem" which means the electric water heater units work in parallel in the circuit to supply about double the flow rate.
@windego40
@windego40 5 ай бұрын
How has this water heater been working for you? looking into getting one
@BathroomRemodelingTeacher
@BathroomRemodelingTeacher 5 ай бұрын
Good, just takes 30 minutes to fill tub with hot water 😆 have to keep flow to about 1.3 gpm to be 125
@brandoneiler4221
@brandoneiler4221 9 ай бұрын
What is the yearly maintenance requirement for this? Should there be service valves for flushing?
@BathroomRemodelingTeacher
@BathroomRemodelingTeacher 9 ай бұрын
Excellent question, only thing would be the inlet filter if debris gets in it. Which requires unthreading the water supply
@charmerxxx
@charmerxxx 9 ай бұрын
thought they needed descale on occasion.
@bobscaping
@bobscaping 9 ай бұрын
@@charmerxxx Hard water around Pittsburgh where Steve is located, with an added dose of high-TDS
@charmerxxx
@charmerxxx 9 ай бұрын
@@bobscaping I'm also in pgh!
@feeblewrk5788
@feeblewrk5788 9 ай бұрын
Why isn’t it code to use a vapour barrier in pitz? Paper back is good enough? I find it odd considering the cold climate changes
@BathroomRemodelingTeacher
@BathroomRemodelingTeacher 9 ай бұрын
That’s what the question arising from this video? To each his own. Look up all the controversy on vapor barriers. You want one, get one 😆
@feeblewrk5788
@feeblewrk5788 9 ай бұрын
Well, I saw paperback insulation in the video, so I only asked if it was code. I wasn’t attacking you or saying it was wrong. Just wondered if poly was used in your area. I’ll just unsubscribe so I don’t irritate you anymore
@BathroomRemodelingTeacher
@BathroomRemodelingTeacher 9 ай бұрын
@@feeblewrk5788 😆 sorry man. Didn’t mean to attack. I personally just hate vapor barriers. I see nothing but problems with it. I may be wrong on not using them
@rudyponzio5871
@rudyponzio5871 9 ай бұрын
You'll never be wealthy switching to point of service. You'll have to put yearly commerce into maintenance. And never not more as required. Ha. Laugh Out Loud if everyone jumps off the Brooklyn Bridge.. They'll still be one guy left to witness it. 🇺🇸
@feeblewrk5788
@feeblewrk5788 9 ай бұрын
??? What are you on
What it feels like cleaning up after a toddler.
00:40
Daniel LaBelle
Рет қаралды 78 МЛН
Sigma girl and soap bubbles by Secret Vlog
00:37
Secret Vlog
Рет қаралды 12 МЛН
Tankless Water Heater Install | Existing Home
21:50
MR Post Frame | Marshall Remodel
Рет қаралды 512 М.
3 Things They Don’t Tell You About Tankless
5:56
Matt Risinger
Рет қаралды 2,6 МЛН
Best Electric Tankless Water Heaters 2024
7:43
Home Reviews
Рет қаралды 7 М.
Gas VS Electric Tankless Water Heaters
4:43
All Things Plumbing, Heating & Air
Рет қаралды 62 М.
Installing a Bathroom Water Heater for Comfortable and Convenient Hot Water Heater
9:15
Learn Pass Earn Professional
Рет қаралды 930 М.
How to Install a Tankless Water Heater | Ask This Old House
10:50
This Old House
Рет қаралды 2,2 МЛН
Gymrat CAT is a CHEATER?! 🙀 #kitten #cat #cute #aicat
0:45
Stunning Cat Stories
Рет қаралды 20 МЛН
貓媽媽🆚爆米花🌽🥷🍿 #aicat #shorts #cute
0:33
Cat Cat Cat
Рет қаралды 45 МЛН
НИЧЕГО СЛОЖНОГО
0:21
KINO KAIF
Рет қаралды 3 МЛН
Как мама ухаживает за мной VS гостями
0:50
Время горячей озвучки
Рет қаралды 3,1 МЛН
The cat chose the right one 🥰🥳😸
0:32
Ben Meryem
Рет қаралды 27 МЛН