Electrical Safety Gloves Student Version

  Рет қаралды 4,347

David Borg

David Borg

Күн бұрын

Пікірлер: 15
@hongkevin4544
@hongkevin4544 Жыл бұрын
Thank you so much ..
@nathanfraser4125
@nathanfraser4125 2 жыл бұрын
every aussie sparky should watch this
@mohammadsaieed1945
@mohammadsaieed1945 3 жыл бұрын
Thanks for helping for SWP your the best شكرا على كل شيء
@terminator-kunterminator-k3926
@terminator-kunterminator-k3926 2 жыл бұрын
At 17:53 you didn't have your gloves back on when using the tester? Is that allowed
@davidborg5996
@davidborg5996 2 жыл бұрын
Art 17:00, he proved all conductors were not live then he tested the tester. It was safe to work with gloves off
@terminator-kunterminator-k3926
@terminator-kunterminator-k3926 2 жыл бұрын
Also at 9:39 you tested between known earth to only the active not all conductors? And you didn't retest the metre on the known live source.....
@davidborg5996
@davidborg5996 2 жыл бұрын
Hi When you are looking for the circuit protective device, you dont need to check each conductor for live. If you test live, the meter is working so you dont have to retest the meter. Once you locate and lock out the protective device for the circuit you are working on, then then must test every conductor to make all conductors are dead, then retest the tester. Only then can you declair the circuit has been safely isolated.
@Maverick00555
@Maverick00555 2 жыл бұрын
@@davidborg5996 could almost guarantee that would fail
@Maverick00555
@Maverick00555 2 жыл бұрын
I failed this exam for leaving my key in the tool box…
@davidborg5996
@davidborg5996 2 жыл бұрын
Hi mate. Keep practicing un til it becomes second nature
@misribanda5555
@misribanda5555 2 жыл бұрын
Now I am a little confused you did the IR test between earth and 3points on frame, shouldn't it be between earth&Live,Earth&Neutral at appliance terminal...
@davidborg5996
@davidborg5996 2 жыл бұрын
Hi. The test between earth and frame is the earth continunity test, The result you are looking for is less than 0.5 ohms. When using a IRC tester or multimeter, select an ohm scale around 2 or 3 ohms.
@Aussieknuckleheads
@Aussieknuckleheads 2 жыл бұрын
where do we get a glove kit from? just the wholesaler?
@davidborg5996
@davidborg5996 2 жыл бұрын
Hi You can try your electrical wholesaler or try Australian Powerline Industries pty ltd Phone 03 9387 1077 Email sales@apipower.com.au
@lucidzwrld2313
@lucidzwrld2313 2 жыл бұрын
Thankyou for the help
Electric Gloves Explained
2:40
PowerPak - Safety
Рет қаралды 10 М.
It’s all not real
00:15
V.A. show / Магика
Рет қаралды 20 МЛН
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 62 МЛН
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
Disconnect and reconnect a motor
21:55
gary currall
Рет қаралды 9 М.
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,6 МЛН
Путин ответил на ультиматум Трампа
7:25
Diplomatrutube
Рет қаралды 1,8 МЛН
Tagging Betterer
8:53
gunsparky
Рет қаралды 16 М.
TEST OF ELECTRICAL INSTALLATION  CHISHOLM
20:19
ELECTRICAL TAFE theory
Рет қаралды 9 М.
Best Gloves For Work
6:33
Essential Craftsman
Рет қаралды 548 М.
Putin urgently interrupted a meeting / Change of power in Ukraine
14:46
Electrical Wire Color Coding Used By Electricians
16:14
Electrician U
Рет қаралды 766 М.
HV - The AS3000 is Easy
4:52
HV Coach
Рет қаралды 5 М.
It’s all not real
00:15
V.A. show / Магика
Рет қаралды 20 МЛН