STARTER (classic) and StartDrive (new) are two generations of drive engineering software. They are just sofware to configure your drive. The topic discussed in the is video is the S7-1500 Syn motion control topic. Does not matter on which engineering tool you are using. If you are using position synchronization, you'd better using S7-1500 T-CPU for position gear. In addition, STARTER is old, try to use StartDrive
@haoyuyou94654 ай бұрын
@@electricalautomation Thank you for your reply. As you mentioned, STARTER is just software for configuring the drives, so I don’t need to focus too much on achieving a specific function with it. I have already achieved the positioning function for one motor using STARTER and open-loop movement for the other motor. I am currently learning TwinCAT 3 through video tutorials, and I will soon try to use the motion module in TwinCAT 3 to control the drives and achieve synchronous movement and positioning of the two motors. Perhaps this is possible? I look forward to your response!
@haoyuyou94654 ай бұрын
@@electricalautomation Because I currently own a BECKHOFF controller, I'll be using a Twincat3.
@Kozak4507 ай бұрын
Can we change the velocity value when the drive is running and the speed will change automaticly?
@electricalautomation6 ай бұрын
Please review this kzbin.info/www/bejne/i523ip-FmpaCm6csi=1Dm2qfRfBtWcv_lL
@abrahamestradaalvarez97102 жыл бұрын
Nice video!! I would like to know what could happen with the slave´s speed if the master has a torque limiting active and a load is aplied until the master stops. I suppose the slave will continue spining since the type of conection is "setpoint".
@electricalautomation2 жыл бұрын
Yes, for S7-1500 regular controller, the gear is base on the Velocity 'Setpoint'. But if you are using S7-1500 T Motion Controller, then you can set 'Actual' Gear
@bhagyodayasinghjadhav2 жыл бұрын
Great 👍
@electricalautomation2 жыл бұрын
Thanks my friend!
@antokingston8348 Жыл бұрын
Sir can you please explain about MC Measuring input it will be more helpful for us thank you sir.
@electricalautomation Жыл бұрын
I would recommend reading carefully for this manual cache.industry.siemens.com/dl/files/466/109766466/att_1004383/v1/s71500_s71500t_signal_function_manual_en-US_en-US.pdf note that CAM with Measuring Input always not an easy topic in motion control. Also, find the document about S120 CU Telegram 393.
@antokingston8348 Жыл бұрын
@@electricalautomation thank you very much sir
@antokingston8348 Жыл бұрын
@@electricalautomation Thank you very much i has one doubt regarding positive and negative edge could you please explain what it means
@amragwa40058 ай бұрын
Can you make sessions about the cpu with technology I have application with s7-300 with technology and used some function mc_camin mc_camout Mc_camswitch Mc_camclear Mc_sectoradd
@electricalautomation7 ай бұрын
No really, sorry, my friend. I understood this old stuff T-CPU and some Cam motion control. There is less materials for this area and it is rarely used. I would recommend using S7-1500 T and use TIA portal and CAM motion control.
@amragwa40057 ай бұрын
@@electricalautomationcan you make session for another functions of cpu technology like mc-camin mc-camout and other functions