Excellent work! So professional... Your 200A upgrade videos are just awesome and interesting. Keep it up!
@electricianron_New_Jersey2 жыл бұрын
Thank you very much!
@thomascraig1085 Жыл бұрын
Section 230.85 requires an emergency disconnect to be installed for all new electrical services as well as when an electrical service is modified or upgraded. Service masts used for the support of service-drop or overhead service conductors shall be installed in accordance with 230.28(A) and (B). The service mast shall be of adequate strength or be supported by braces or guy wires to withstand safely the strain imposed by the service-drop or overhead service conductors. 250.24(A)(1) Connect the grounding electrode conductor at any reachable place from the load end of the overhead or underground service conductors, service drop, or service lateral to the terminal or bus-at the service disconnecting means-to which the grounded conductor is connected.
@electricianron_New_Jersey Жыл бұрын
Think I should go back and add the disconnect even if I’ve already gotten the final approval?
@mikewallace5394 Жыл бұрын
Your work looks good! We do the exact same process here in St. Louis Missouri. However our utility company here requires the meter base with a lever bypass. I run my own company here and operate the same way you do. Good looking work!
@electricianron_New_Jersey Жыл бұрын
Thanks for the info! Each utility company is a little different.
@aidanray48463 ай бұрын
What’s up neighbor I work for Hoffmann brothers everyone
@russrockino-rr08642 жыл бұрын
Yes, we are required to use conduit for a service riser here in Oregon. You are lucky Ron, your way is less time consuming. Great video, Thanks, Russ-Electrician from Oregon.
@electricianron_New_Jersey2 жыл бұрын
It's different all over the country as it should be. What I'll never understand is states like California and Arizona where the service panel is outdoors and ganged-up with the meter. Now if a breaker trips you have ti go outside to reset the breaker. That never made any sense to me.
@leengly3127 Жыл бұрын
@@electricianron_New_Jersey yeah also in Colorado, house panels are outside in the cold. Here in Minnesota service riser has to be in conduit. If your conduit goes through the roof, the conduit has to be imc, can’t run pvc.
@jamescollins81482 ай бұрын
As always! Superior work! I would’ve corrected that conductor running through the block. But that’s me. I just don’t like leaving poor practices.
@unstableatbest2 жыл бұрын
Hi Ron, I'm a one-man electrical contractor, myself. I noticed in another vid where you're on top of the roof, you have kind of this nice 2" thick rubber tape for going over your butt splices on the drip loops. Between that and the 4-pronged Klein large wire stripper, I've been picking up little tips like those, and I appreciate ya, man. Little stuff like that which a hardened 1000 yard stare master electrician can still learn from another pro... just always looking to ease the burden a little more all the time, ya know? All the best, brother.
@electricianron_New_Jersey2 жыл бұрын
Hi Tim, we can all learn from each other. It’s about pulling each other up the ladder, not kicking the ladder out from one another. I’m glad you enjoyed the video!
@davidchesley6363 Жыл бұрын
@Electrician Ron hi, I like your style. Mike Holt says anti oxidant is unnecessary.
@russrockino-rr08642 жыл бұрын
Cleanup is easy to do when you are your own boss. When your working for someone else, sometimes the boss wants you out of there and on to a different job and they don't want to pay for you to stay late. Or you get called to do a service call somewhere else. It is much different when you are working for someone else. Also, I would be required to have the panel all labeled properly before leaving. No comebacks. I always hated doing service changes by myself. Here in Oregon your always running conduit, drilling holes in roofs, installing roof jacks and guy wires kits. It was always a very long day by myself. Thanks, Russ-Electrician from Oregon.
@electricianron_New_Jersey2 жыл бұрын
Cleaning up and using drop clothes makes a big difference in getting repeat business and referrals. People expect you to do GREAT electrical work but leaving a mess behind is all they'll remember even if you did a good electrical job.
@ernestperino9334 Жыл бұрын
I like to fill the weatherhead with duct seal to help prevent water running inside the cable
@electricianron_New_Jersey Жыл бұрын
I do that sometimes too.
@dwreed63 Жыл бұрын
You're a true professional. I've learned a lot from watching you and I appreciate it. 🤙👍👊
@topher7720 Жыл бұрын
I purchased a piece of property that has 442 aluminum sticking out of the ground two black one white. I bought 442 aluminum that's two black and one stripe and I have to go through and connect to the meter out by the road and to the 200-amp Box + 2 RV boxes and I realized after not messing with this stuff for over 23 years and I'm just an individual on top of it you really have to think of what's going on because I have to connect and heat shrink to the existing wires sticking out of the ground and run 40 feet to the Box you guys definitely have your work cut out for you working on this stuff.
@RCRadioShow Жыл бұрын
I found your channel about a month ago and enjoy your service upgrade videos. I admire your work and would not hesitate to hire you for any electrical work. I am an electrical engineer by trade and worked in the power field almost 40 years. I have a couple of comments. I think you could use a lot less Penetrox on the service connections. I think a bead applied with the bottle nozzle and spread with a small brush would do the job. Burndy says "apply liberally" so I guess that is subject to your own judgement. I know too much is better than too little. The other comment concerns arc flash hazard. I was involved in an arc flash incident on a 480 volt motor control center years ago before we took arc flash seriously. I was extremely lucky not to lose my vision. We had defeated the door interlock on a starter for a 200 HP motor to check something. The MCC decided to fault on its own just as I had turned my head away to stand up. I still suffered second degree burns on the side of my face and welders flash burn on my eyes. In your work I would wear a face shield, leather gloves and long sleeves when unplugging and plugging the meter in and operating the main breaker. Actually pulling and plugging in the meter is probably the most dangerous task you do since you are making or breaking the circuit with something not designed to do that and the meter condition is unknown to you. The main breaker is brand new and should be in very good condition. NFPA 70E, Standard for Electrical Safety in the Workplace has a very good guide on arc flash hazard and work practices. It would be worth getting if you do not already have it. Where I worked we adopted NFPA 70E after suffering a number of arc flash incidents. Some involved third degree burns and permanent injury.
@SG-zh5xd Жыл бұрын
I bet you do get a lot of comments about the service drop not being in a conduit .I like Square D panel looks clean !
@electricianron_New_Jersey Жыл бұрын
If they’re familiar with NEC article 230 they’d see SE Cable listed as an approved wiring method.
@ellenpecina9832 жыл бұрын
Great job Ronnie the Rapper! You make me so proud❤
@salvatorecarapazza2485 ай бұрын
Love these service upgrade videos. It's funny when you say if there is a better way to do it nave in the comments. Very humble but you are an Electrical Ninja! Awesome!
@electricianron_New_Jersey4 ай бұрын
Thanks man. A lot of experience.
@larrymoore66402 жыл бұрын
Nice job.... I like the tip about turning away when flipping on the Main Breake.
@electricianron_New_Jersey2 жыл бұрын
Glad it was helpful!
@kevinhurley36992 жыл бұрын
I forgot my next door neighbor a retired machinist sat in a lounge chair and watched me do the upgrade. I was 20 years when I did it,
@matthewmidgett6531 Жыл бұрын
Always install the surge breaker at the top of the electric panel
@chuckquinn80262 жыл бұрын
Sweet job, and completely by yourself 👍👍. That’s a very long day! Excellent video and description of the work.
@electricianron_New_Jersey2 жыл бұрын
Thank you, Chuck!
@jfinaz992 жыл бұрын
Superior attitude, superior work. 👍
@electricianron_New_Jersey2 жыл бұрын
Thank you!
@jboywebby2 жыл бұрын
You do great work very neat in your work & clean up
@vince68292 жыл бұрын
Nice job!!! Thank you for sharing your knowledge.
@TEDOTENNIS2 жыл бұрын
Fantastic video! Thanks taking the time to show the process. Have a great 2023!
@electricianron_New_Jersey2 жыл бұрын
Thanks, you too!
@johnathenevans61392 жыл бұрын
Wonderful work, sir. I appreciate learning more about your trade through your videos. I’m curious if you’ve ever had to upgrade service for tankless electric water heaters.
@electricianron_New_Jersey2 жыл бұрын
Fortunately, most of New Jersey has natural gas access.
@roybreeden89282 жыл бұрын
Well done Mr. Ron! Appreciate share - All Pro!
@pawelelektryk29852 жыл бұрын
I started using ratcheting cutters and that klein *big cable* stripper myself recently. They cost a pretty penny but both are life savers.
@electricianron_New_Jersey2 жыл бұрын
If the tools saves time in labor it’s worth it!
@rongwu7181 Жыл бұрын
Great job.
@jessesmith16812 жыл бұрын
Some localities around me still allow for riser without conduit but I myself have never done it that way . I always put my service cables in conduit for the main reason I've seen too many risers and entrance cables that weren't in conduit the outer sheathing would Crack open and allow water in and once water gets in the cable it corroded the aluminum neutral wire and causes you to loose the neutral. I've had to replace several service cables for this reason . If the cables don't receive a lot of direct sun it's not as bad but I still won't install without conduit even if allowed. Also here if changing out complete service or upgrading service if the breaker panel is not directly behind the meter base so that a short nipple can be installed between themthenwe have to install an outdoor disconnect
@electricianron_New_Jersey2 жыл бұрын
The old SEU had issues but todays SEU cable is much improved.
@l.rod28276 ай бұрын
Obviously you have a lot of experience as you make it look so easy. Nice R&R of the panel and all the necessary hardware. I wish you worked out in Southern California. I'm looking at doing something similar but to include a critical load panel for a battery backup system. Any electrical company recommendations for the High Desert (Victorville) area?
@electricianron_New_Jersey6 ай бұрын
@@l.rod2827 Sorry, not in California.
@IreneWalter-nd4ce2 ай бұрын
Ron, How do you ID the individual circuits (labels) when the job is finished? I can think of difficult ways but do you have a better way?
@impsquared Жыл бұрын
amazing work!! well done!
@rajenwilliams2 жыл бұрын
Love these videos...so educational for me. Thank you.
@electricianron_New_Jersey2 жыл бұрын
Glad you like them!
@mcarroll5982 жыл бұрын
With all the services you do, you should invest in a cordless Milwaukee H-crimper. It can cover all ranges of wire sizes for the run and tap connections on services. A lot faster and easier than the mechanical crimps when doing services. Just a suggestion.
@electricianron_New_Jersey2 жыл бұрын
I was looking at that last night. Only $2700 at Acme Tools. I would be helpful as it not only crimps but also has dyes available to cut large conductors.
@mcarroll5982 жыл бұрын
@@electricianron_New_Jersey seriously think about it. It’s kinda pricey, but it pays for itself after a few jobs…..It’s awesome. And you love Milwaukee tools so there’s a win-win!! Haha
@mcarroll5982 жыл бұрын
And we cut a ton of wire with the interchangeable head. It’s so fast. Slices thru 500kcmil like nothing.
@johndursee5971 Жыл бұрын
Ron great video!! is it smart( suggested) that I turn off all breakers before turning of the 'Main' or is it ok just to turn off the main and not kill each breaker first? Thx!
@Nihilumbra2 жыл бұрын
Как приятно посмотреть квалифицированную и качественную работу, а также на мастера, выполняющего её (работу) со знанием и уважением 👍😉😎. Спасибо.
@electricianron_New_Jersey2 жыл бұрын
Thank you!
@joebert8892 жыл бұрын
How about a safety glasses or even a shield when you plug in that meter
@benlord1902 Жыл бұрын
Sweet!!!!
@johnmazzocchi71162 жыл бұрын
Nice work as always Ron! Love the new Square D panels! Finally someone using their noggins! Have you seen the new Leviton panels at Home Depot?
@electricianron_New_Jersey2 жыл бұрын
Not yet! I've seen them before at a Levition presentation some time back at an IEC presentation.
@Cubik3032 жыл бұрын
Very clean, pro job. Quality workmanship start to finish.
@electricianron_New_Jersey2 жыл бұрын
Thanks 👍
@garycunningham847811 ай бұрын
How do you secure the bottom meter socket with screws
@timothykraft49092 жыл бұрын
Thanks for the great videos Ron! On the Meter sockets! I got a little confused with Horn bypass and the lever bypass! Any info if you don't mind sharing would be great! I know in our area the power company requires a 200 amp meter socket to have a lever bypass! I got curious what the 2 bypasses do! Thanks again for the great videos!
@electricianron_New_Jersey2 жыл бұрын
I'm sorry I cant help you. I dont even know the difference between the two either! Around here we use ringless with PSEG and JCPL.
@aerofart Жыл бұрын
I like that you use a professional labeling system to identify your breakers. I got a great deal on a used, like new Brother electricians label printer that I use to give everything I do a professional appearance and added utility. You might consider getting some professionally designed labels with your company logo and info to stick onto your panels for repeat business and easy service calls.
@JuanMartinez-dz7wn2 жыл бұрын
Thanks I found youtube chanel. Iam learning electricity. What number of wiring are you using for miror, and how to cut the power outside on mirror to upgrade panel. Please. Thak you.
@electricianron_New_Jersey2 жыл бұрын
A 200 amp single family dwelling service requires 2/0 AWG copper or 4/0 AWG aluminum.
@lchen4292 Жыл бұрын
How do you make sure that you aren't grounded? By the way, there is no way I am going near a live wire. I am curious as your comment about "make sure that you aren't grounded" when connecting the city wire to the new house wire.
@electricianron_New_Jersey Жыл бұрын
Because if you’re grounded you give a path for electrons to flow.
@aerofart Жыл бұрын
So what had my pucker factor at full-scale is seeing you connect your feeders to the service lines. Aluminum ladder? And your proximity to the grounded metal conduit with no gloves or limb coverings would scare the begezus out of me. Am I correct in seeing this as a risky situation or am I missing something?
@electricianron_New_Jersey Жыл бұрын
Fiberglass Werner 28’ 300lb’r.
@kevinhurley36992 жыл бұрын
Brings back memories I did this upgrade to my parents house in 1980 while working for a electrical contractor a permit was pulled it passed.
@DTzant2 жыл бұрын
You’re from Point Pleasant where they have the “Point Pleasant Police Depotment” 😊
@electricianron_New_Jersey2 жыл бұрын
Hi David, I'm not sure what you are referring to.
@DTzant2 жыл бұрын
@@electricianron_New_Jersey Sorry…it’s a skit they use to do on the Jimmy Fallon show. Ha. I’m a journeyman and I enjoy watching your content. Nice work.
@tracle8334 Жыл бұрын
can you cover a video with Circuit breaker Surge protector?
@electricianron_New_Jersey Жыл бұрын
Sure can.
@bigdaddy4975 Жыл бұрын
Would you get shocked if your touching both ends of the line wire on the incoming service ?
@electricianron_New_Jersey Жыл бұрын
Yes.
@stillthakoolest10 ай бұрын
Im not very familiar with SE cable like that. Are the conductors themselves labled with their insulation class? I know NM cannot be removed from its sheath to sleeve it in conduit, but wasnt sure about SE like this.
@electricianron_New_Jersey10 ай бұрын
Service-entrance cable is a listed and approved wiring method for service entrance conductors.
@Mikey_The_Electrician2 жыл бұрын
Hey Ron. Are you not a allowed to crimp your service back in, in NJ? Also have you ever used the plastic tap connector covers for your lugs?
@ptso75802 жыл бұрын
SPD in the box? So Jersey moved up to 2020? Hope this is not late, Happy New Year Ron. Looking classy job well done. 👍.
@electricianron_New_Jersey2 жыл бұрын
I included the SPD with this job but were still not 100% on the 2020 NEC yet.
@ptso75802 жыл бұрын
@@electricianron_New_Jersey Gotcha. Here in AZ it's to local interpretation. State wide it's the wild west. Thanks for getting back. 🙂
@stevesolt40362 жыл бұрын
Square d panel cover screws always have alignment issue
@sweepingdenver2 жыл бұрын
Ha, it's like romex but for service conductors.
@electricianron_New_Jersey2 жыл бұрын
It's done like this all over the Northeast.
@garycunningham847811 ай бұрын
People say you should brush the antioxidants on the wire itself. Did you ever hear that?
@stevesolt4036 Жыл бұрын
Does NJ require the exterior disconnect for fire on the service?
@electricianron_New_Jersey Жыл бұрын
Nope! Not until 9/6/23.
@elangomattab2 жыл бұрын
Hey Ron, thanks for the video. In part 2 of this upgrade you talked about the multi wire branch circuits. Are those wired in the box as the top 6 breakers on the right side of the box? I assume so since they are done with double pole breakers which will both trip if one half trips. I have at least one multi wire branch circuit in my house (kitchen) but unfortunately the breakers aren't next to each other right now. Would it be a good idea to have an electrician come out and fix this? Would it also make sense to upgrade to GFCI breakers as well since I don't currently have any GFCI protection in my kitchen?
@electricianron_New_Jersey2 жыл бұрын
The double pole breakers are for the MWBC's. They share a neutral conductor. Both of the hot legs should be on opposite legs so you dont overload the neutral conductor.
@christophershaffner2827 Жыл бұрын
I'm in Central NJ and I'm considering a panel replacement and service upgrade. How much does a job like this cost?
@electricianron_New_Jersey Жыл бұрын
Each one is different but they’re starting at $2800.00.
@mattschoular8844 Жыл бұрын
Are you required to have your work inspected afterwards?
@electricianron_New_Jersey Жыл бұрын
Of course. It passed no problem.
@tmitch49762 жыл бұрын
Is it a N.J. thing with red on the left. Always thought Black,Red,Blue.Nice job other wise
@electricianron_New_Jersey2 жыл бұрын
It’s single phase and it does not matter. Black Red Blue is a three-phase configuration so motors spin the right way.
@stevesolt4036 Жыл бұрын
Seems panel cover screw holes for square d are always out of alignment
@electricianron_New_Jersey Жыл бұрын
You ain’t kidding!!
@ronaldboucher30812 жыл бұрын
Hey Ron , it looked like the ladder was aluminum. Is that a path to Ground?.. Thanks for the video , i did enjoy! Always looking to learn... p.s. great name! Sussex county , NJ
@electricianron_New_Jersey2 жыл бұрын
Did you really think I'd be tying in a service with an aluminum ladder? Always fiberglass.
@aaron742 жыл бұрын
@@electricianron_New_Jersey And the orange fiberglass for us big guys lol
@1percentSolutions23 Жыл бұрын
How do you make sure your not grounded ?
@electricianron_New_Jersey Жыл бұрын
Insulated equipment/ tools.
@dawnmitchell82132 жыл бұрын
Good help is a rarity these days. There’s nothing worse than relying on other people and being in a wheelchair I have to rely on other people to run cables for me and do many other things that I can’t do that requires functioning legs.It’s a tad bit frustrating to say the least not being able to do simple 5 second task if I only I could stand up for just 5 seconds. I’m cursed with still enjoying working with my hands and doing physical labour while in a wheelchair.
@steveloux47092 жыл бұрын
Rather than contemplate the loss of your face or hands, how about you put the panel cover on before energizing the bus? It would take five minutes tops. And maybe meg-ohm the bus and feeder (branch OCPDs in the OPEN position) up to the weatherhead before energizing? And wear insulated gloves with leather outers to make up the utility, just as the lineman would?
@electricianron_New_Jersey2 жыл бұрын
Sure, if I can get the utility company to supply all the tools/ clothing necessary to do all that.
@sciatl25052 жыл бұрын
Nice clean install but this wouldn’t pass code here in Florida
@electricianron_New_Jersey2 жыл бұрын
Oh is that right? Why not.
@sciatl25052 жыл бұрын
@@electricianron_New_Jersey Florida is on the 2020code the disconnect must be outside next to meter also FPNL requires the grounding be connected in the meter
@aaron742 жыл бұрын
@@sciatl2505 NJ is 2017 NEC
@steveloux47092 жыл бұрын
@@sciatl2505 The NEC allows the GEC to be terminated in either the meter base or the service disconnect equipment. So if "FPNL" requires something else, it's irrelevant elsewhere.
@quintinfletcher19762 жыл бұрын
what gauge is the cable
@sciatl25052 жыл бұрын
Look like 4/0 New Jersey is on the 2017 code
@linehandibew62052 жыл бұрын
Surprised you’re using seu for the riser……didn’t know anyone still used that crap 🤮
@linehandibew6205 Жыл бұрын
Just busting chops brother. You do great work
@tylershafer79292 жыл бұрын
Holy cow that's a lot of antioxidant!!! If u read the bottle it tells u to wipe off excess. But like u put in video, u don't need it. Lol. If that wire corrodes, then u might as well smear it all over the lugs, buss, and all. Same material. It actually changes the torque spec. Which goes against UL listing. Which goes against code. Which is WRONG. So going above and beyond is not what ur doing there. Same as "adding extra grounds to make the house safer" kind of logic. Pure ignorance. Good job tho with the rest of the work!!! I'm h3//bent on getting antioxidants off the market.
@electricianron_New_Jersey2 жыл бұрын
Don’t worry I know all about grounding and only a fool would add additional grounds to “improve” the grounding.
@tylershafer79292 жыл бұрын
@Electrician Ron "additional" grounds connected properly to the main grounding system is amazing. So yes, more grounds the better in ONLY that senerio. Mainly talking about Separately Derived Systems. I.E. home standby generators with their own ground rod. Big no no. Some ppl install ground rods at heat pumps. Also huge no no. The Grounding Differential Potential is huge in the instant lighting were to strike. Causing thousands of volts to go up the EGC and potentially burn ur, or ur clients, home to the ground. So yes, "more grounds the better" saying can and will be extremely dangerous for those arrogant people set in their ways.
@mikewallace5394 Жыл бұрын
Your work looks good! We do the exact same process here in St. Louis Missouri. However our utility company here requires the meter base with a lever bypass. I run my own company here and operate the same way you do. Good looking work!