What Happen when DC Voltage Given to Transformer| Why Transformer not work on DC

  Рет қаралды 13,761

Electrical With Abhishek Joshi

Electrical With Abhishek Joshi

Күн бұрын

Пікірлер: 72
@techno-tips13969
@techno-tips13969 6 ай бұрын
Well explained... Simply, coil is a short circuit against DC
@ashishfasate4850
@ashishfasate4850 10 ай бұрын
Very informative and logical video .sir please make more videos .
@akshayakumarmahaling1195
@akshayakumarmahaling1195 8 ай бұрын
Jabardast sir.......aap ko meri taraf se .......salute💯🙏
@WaqasAli-nl7kz
@WaqasAli-nl7kz 7 ай бұрын
Your All videos are very informative sir, Thanks 👍 from Pakistan ❤
@tayyabatanvir8961
@tayyabatanvir8961 6 ай бұрын
Very well explained each and every video Thankyou so much make more of Electrical Engineering Interview Videos
@SantoshKumar-yk3wg
@SantoshKumar-yk3wg 10 ай бұрын
Very nice sir please make video PLC series.
@rudranarayankhuntia9246
@rudranarayankhuntia9246 10 күн бұрын
Really helpful, well Explain bro👏👏
@SukhdevSingh-zq2kb
@SukhdevSingh-zq2kb 10 ай бұрын
brillant sir bhut informative conti......
@brilliantentrepreneur7330
@brilliantentrepreneur7330 10 ай бұрын
What a greatest video sir....technically cover all point with suitable explaination ..thank you for video👌👍
@arunjoshi2089
@arunjoshi2089 10 ай бұрын
Very informative
@worldinstrumentationengineer
@worldinstrumentationengineer 10 ай бұрын
बहुत अच्छा गुरू जी प्रणाम
@sailadarahulkumar8510
@sailadarahulkumar8510 7 ай бұрын
Thank you sir for your useful informations😊
@Munavvar_Mansuri
@Munavvar_Mansuri 10 ай бұрын
I have one question then why it’s not burn when we apply megger DC voltage ???
@ratnapriya2304
@ratnapriya2304 9 ай бұрын
omg sir u are excellent.thank you for this
@SABIRKHAN-eu8nf
@SABIRKHAN-eu8nf 10 ай бұрын
Good information share
@sameerchalke783
@sameerchalke783 10 ай бұрын
Hi Abhishek, very informative video. I have query on HT & LT cable sizing criteria, hope you can make video on it or answer over here. For HT cable sizing first criteria is always to find minimum cross section area based on short circuit rating, however for LT same is not consider, also in case consider it is not practical to terminate such higher size cable in small rating of motor ranging from 0.37 kw to 45 kw, also economically not viable solution ( these are my thoughts) whats your take on LT cable size with respect short ckt rating of the system
@HariKrishnan-vl1wv
@HariKrishnan-vl1wv 10 ай бұрын
Sir, do a video about the data centre. Cooling system.
@AkashKUMAR-ot3ts
@AkashKUMAR-ot3ts 10 ай бұрын
Sir electrical equipment standard rating related video bana dejiye intwerview me pucha ja raha hai jaise ceing fan ki standard speed and many more
@vinodshah5120
@vinodshah5120 8 ай бұрын
Superb sir🙏
@PankajMadhale
@PankajMadhale 10 ай бұрын
Plz sir iti technician4 pareshaan ibps pattern pe video baniye motivation imporve ho Raha apke video dekh ke ❤ without fess itna acha studey material cover ho Raha !!!
@shailendrajadon3599
@shailendrajadon3599 10 ай бұрын
Very informative video
@boshudev8674
@boshudev8674 10 ай бұрын
If the capacitor of the ceiling fan is weak, the fan rotates slowly, but if the capacitor of the single phase induction motor is weak, the motor does not rotate slowly, after a while the motor stops rotating completely. What is the reason for such a difference? plz make a video on this topic
@vrajvariya8413
@vrajvariya8413 10 ай бұрын
Sir ht panel me HV & megger test kyu Lena padta he uske related video banavo 🙏🙏
@narsingrao4724
@narsingrao4724 10 ай бұрын
super sir
@waqarahmed858
@waqarahmed858 10 ай бұрын
Very well explained 👏
@sanaparveen9642
@sanaparveen9642 10 ай бұрын
Sir electricity bord se 3 phase and neutral supply aati hai or hamare building me single phase ki tarh use hoti hai but tino phase k wire and neutral wire same size ka hi Aisa q Agr har phase me 5 amp current flow ho rah hi to neutral wire me 15 amp current flow hota hoga to neutral wire mota hona chaie . Yahan system to single phase ki tarh use hoara hai to system to unbalance hai yahan koi 3 phase motor to nahi chal rahe hai system balance ho or neutral me koi current nahi flow horaha . To neutral wire mota q nahi hai plese help.
@preetirani753
@preetirani753 10 ай бұрын
Very helpful sir
@suryatechb.e2778
@suryatechb.e2778 10 ай бұрын
Dear Abhisek ji Transformer name plate my winding 35,and oil temperature 40 degree hoga, but we are keeping in tripping in 65 degree above, why sir?? Please explain this concept
@AnujKumar-bg6hp
@AnujKumar-bg6hp 10 ай бұрын
Awesome sir 👍
@nayanbhandari18
@nayanbhandari18 9 ай бұрын
Wow sir....very unique
@sarojkumarpradhan1917
@sarojkumarpradhan1917 10 ай бұрын
Sundar prachestha thanks
@kundansgaikwad4619
@kundansgaikwad4619 9 ай бұрын
nice and explain in simple language
@creativesn2sgallery827
@creativesn2sgallery827 10 ай бұрын
Sir,does a RCBO can protect against lightning for house wiring?? Please make a video on this topic. 🙏🙏
@prabirnaury7813
@prabirnaury7813 3 ай бұрын
I've one question.Then why its not burn, when we inject dc voltage by meeger?
@abubakertimol4352
@abubakertimol4352 8 ай бұрын
Sir good morning A P F C panel me higher rating ke capacitor jaise 600 kva use karne se harmonic problem solve hoga
@shyamsunderdeo7208
@shyamsunderdeo7208 3 ай бұрын
DC mcb aur AC mcb me difference kya hota hai bataye Sir
@fahimasghar6375
@fahimasghar6375 10 ай бұрын
Nice video Sir, Please tell us that how much DC voltage will apply? Means kitnay dc voltage honay chahiye jis pr transformer winding burn ho jayegi? Thanks
@SaiKishoreKshirasagar
@SaiKishoreKshirasagar 10 ай бұрын
The winding acts as a short circuit across the terminals of the Direct current t(DC) source that leads to the flow of heavy current through the winding resulting in overheating of the winding. Iske liye primary winding burn hojayega, 50volts ke jadha volts diyetho it's start as SC in the winding. Hence we cannot give Dc in the primary side. But when you have the megger test to check the insulation we can inject the DC volts as per the rating of the transformer. But we cannot give the supply of DC continuously. At the time of the insulation test we can give the DC volt for checking the windings of the transformer. I hope you got answer by this.
@durgeshpandey1381
@durgeshpandey1381 8 ай бұрын
Sir Rectifier Transformer Kya hota hai...??? Please make a video🙏
@abhijeetpatil592
@abhijeetpatil592 10 ай бұрын
❤ thank you Sir
@elensahu2662
@elensahu2662 10 ай бұрын
Sir instrument ka uper video banaea
@yashindravadankayasth4204
@yashindravadankayasth4204 10 ай бұрын
Sir DC Current Increase hone se CORE BHi Magnetize ho jayegi To Magnetization se hata ne ke liye kya kare ?
@76tyeeitanmaykaranjikar51
@76tyeeitanmaykaranjikar51 10 ай бұрын
Very nice 😊
@AjayBappakhana
@AjayBappakhana 10 ай бұрын
Sir why because transformer AC voltage input supply why but not dc supply flux generating no How to dc motor generating flux
@NagarajuDoddi-f8m
@NagarajuDoddi-f8m 5 ай бұрын
Thankyou sir
@rajivrai4235
@rajivrai4235 10 ай бұрын
Thora PLC bar bhi video banai aur di do ai ao ay sab par
@sameershigwan4311
@sameershigwan4311 10 ай бұрын
Thank you sir
@souravdubeydubey2165
@souravdubeydubey2165 10 ай бұрын
Very good video
@srikantakumarjena2928
@srikantakumarjena2928 10 ай бұрын
nice sir
@udairegar2304
@udairegar2304 10 ай бұрын
Ir conducted during applied dc voltage 5 kv above
@ArvindGupta-j3g
@ArvindGupta-j3g 10 ай бұрын
Sir mai arvind gupta rajasthan me 9 MLD STP plant me ele post pr hu sir hmare yha din ke 2 bje se rat 11 se 12 bje tak voltage 455 se 470 tk ho jata hai hmare yha 630 kva ka transformer hai aur hmare yha 80 aur 40 hp ka pump chalta hai aur 75 kw ka blower chalta hai kya kre kya karn hai
@RashidAli-no2tn
@RashidAli-no2tn 10 ай бұрын
Sir, use onload tap changer or servo stabilizer
@SaiKishoreKshirasagar
@SaiKishoreKshirasagar 10 ай бұрын
Use onload tap changer(OlTC) and adjust rt side and lt side in the OlTC panel. And at the starter set the values of OC if the MPR relay is available.
@vikasparmar18
@vikasparmar18 10 ай бұрын
Volume too slow.
@ARkasamaraj8421
@ARkasamaraj8421 10 ай бұрын
Sir servo valve with full details
@gauravkatke2557
@gauravkatke2557 10 ай бұрын
Thanks
@mohammadzubairfarooq8765
@mohammadzubairfarooq8765 10 ай бұрын
Good
@tanzeemkhan85
@tanzeemkhan85 10 ай бұрын
@Abhijeet578
@Abhijeet578 10 ай бұрын
Sir is there any opportunities for freshers in Aditya birla?? I mean upcoming recruitment etc..? I am a Btech,EE 2018 graduate
@SaiKishoreKshirasagar
@SaiKishoreKshirasagar 10 ай бұрын
2018 passout ho aap fresher kaise hothe he... Do one thing take some additional courses.
@shaukatdaulat4170
@shaukatdaulat4170 10 ай бұрын
Super
@shaukatdaulat4170
@shaukatdaulat4170 10 ай бұрын
Sir please share the Air Gape sensor details (Rotor Stator Hydro)
@mzia854
@mzia854 10 ай бұрын
Nice
@ArvindGupta-j3g
@ArvindGupta-j3g 10 ай бұрын
Good night sir
@krishhV06
@krishhV06 4 ай бұрын
👌🏼👌🏼👌🏼👍👍🙏✅
@mzia854
@mzia854 10 ай бұрын
❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤
@gauravverma7256
@gauravverma7256 10 ай бұрын
Kul mera interview ha as fresher
@milton8778
@milton8778 10 ай бұрын
If you explain these things in English you will reach to more people..👍
@Yaur6355
@Yaur6355 10 ай бұрын
Nahi bilkul nahi
@SukhdevSingh-zq2kb
@SukhdevSingh-zq2kb 10 ай бұрын
mutual flux pr video jur bane....
@MuhammadSaleem-id3vi
@MuhammadSaleem-id3vi 10 ай бұрын
why not heat losses of transformers, you are not using for heating water, oil, in your SORROUNDING economic needs to overcome 😂😂😂😂😂😂use of Engineering Economics 🎉🎉🎉🎉😂😂
@PankajMadhale
@PankajMadhale 10 ай бұрын
How to Synchronise Generator and GRID| Generator parallel operation| Synchronoscope
5:43
Electrical With Abhishek Joshi
Рет қаралды 18 М.
1% vs 100% #beatbox #tiktok
01:10
BeatboxJCOP
Рет қаралды 67 МЛН
Enceinte et en Bazard: Les Chroniques du Nettoyage ! 🚽✨
00:21
Two More French
Рет қаралды 42 МЛН
Why we Use 3ph? Why Not 4ph, 5ph??| Why Transmission done with 3ph| 1ph vs 3ph System
9:01
Electrical With Abhishek Joshi
Рет қаралды 31 М.
The Impact of DC Supply on Transformers | Explained with Simulation | TheElectricalGuy
16:17
Dissolved Gas Analysis DGA Interpretation
18:20
Oil Analysis
Рет қаралды 5 М.
Can we Connect Earthing in place of Neutral | Neutral vs Earthing | Interview Question
7:16
Electrical With Abhishek Joshi
Рет қаралды 251 М.
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,4 МЛН
Why Transformer Rating in KVA and Motor in KW - Electrical Dost
8:07
Electrical Dost
Рет қаралды 112 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 2,1 МЛН
Motor Fuse Blown Frequently | How to Check Electrical Motor| How to do Megger |
7:19
Electrical With Abhishek Joshi
Рет қаралды 21 М.
Interview Question on Transformer Loss| Types of Transformer Loss| Eddy current Loss| Hindi
9:21
Why Transformer rating in kVA | Types of Loss in Transformer | Hindi
6:48
Electrical With Abhishek Joshi
Рет қаралды 101 М.