Lo impact is for keystones and punch down blocks with the same type pins so you have less chance of damaging the pins and the tabs. Hi impact is for your traditional 66 block type connections and uses more force to get to the board and cut the wires. I have done some government wiring years ago and we had to certify each wire for it's speed capabilities, it would give you a pass or fail but also numbers for the speed it could transfer data. If you had too much untwisted wire the capabilities of the data cable would be diminished. Great video and a lot of useful information, I always enjoy your videos.
@jenniferwagner45953 жыл бұрын
A quick tip, once you expose the wires, use the string and pull it back to slit the sheaf. This prevents nicking of the twisted pairs. I usually use my scissors and cut into the first inch or so of the cable, find the string and pull it back. There are pass thru versions of the rj45 plug that make it easier to verify the pairs are correct. The crimper than cuts the excess cable.
@SomeGuy-hf4nl2 жыл бұрын
Right! The string is used because usually exposing the wires causes nicking which isn't always noticeable. So I always just assume the wires have been nicked during exposing, and plan to throw that section away.
@abc-bu7nr Жыл бұрын
I never use a string but I've been doing it for many years. People just have to learn to score the jacket and not cut it. If you're only doing a few that's fine, if you're a few hundred The string gets very tedious
@Tw1steD247 Жыл бұрын
Yes, guaranteed way to ensure you didn't knick through and expose copper.. pull enough wire so you can strip back to clean wire and you won't be going back to fix it months later.
@Tw1steD247 Жыл бұрын
@@abc-bu7nr yes once you get the touch/ feel then great. But for a beginner I personally recommend them to use the pull string.
@jenniferwagner4595 Жыл бұрын
I recommend training people to use the string instead of using a stripper of some sort to pull of the sheaf. It sucks to have to reterminate later because of a break or short circuit. The best solution on course it to pay a contractor to do it, so you can focus on more important things. 😉 It's a good skill to know, especially for one off problems.
@GerbenWijnja2 жыл бұрын
Great explanation of the keystone jack, very informative. 3:10 "With ethernet you're only using 4 out of these 8 wires." That's partially correct. With 10/100 Mbit, you use 4 wires: 1 pair for TX and 1 pair for RX. But 1 Gbit uses all 8 wires: 4 bidirectional pairs. You can try this yourself by only connecting the 4 wires mentioned in the video (pin 1, 2, 3 and 6) and then connecting for example your laptop to your router. It will show that it's connected at 100 Mbit instead of 1 Gbit.
@jenniferwagner4595 Жыл бұрын
People used to cheat and run phones and such on the other pairs. This of course really screws over the next tech trying to figure out such madness. (I have seen four phone lines run a cat 5. Ugh)
@lyfandeth4 жыл бұрын
Cat5 "UTP" stands for *unshielded* twisted pair. Not "universal". And STP is, conversely, *shielded* twisted pair, referring to an RF shield wrapped around the wire bundle, under the outer jacket.
@spammanchan46223 жыл бұрын
I was about to say the same thing it upsets me when people make videos but don't do a two second Google search to get the right acronym
@stevenholton4382 жыл бұрын
He just spaced it ffs
@diegocruz90802 жыл бұрын
@@spammanchan4622 it’s really not a big deal
@ricardoa.denegrimartinez96882 жыл бұрын
Do i need an stp or an sftp if I'm going to wire it thru concrete walls via hoses? Or an UTP it's okay?
@deang56222 жыл бұрын
What do you expect, he's an electrician! They deal with mains electric cables. 95% of electricians won't even know what balanced transmission is.
@EsotericArctos5 жыл бұрын
Gigabit Ethernet uses 8 wires (4 pairs). Only 100mbits and 10mbits ethernet leave 2 pairs unused, unless Power over Ethernet is implemented, then all 4 pairs are used again. It is critical to get the wiring of all 4 pairs correct for Gigabit or 10Gigabit ethernet. It is also critical for systems that use Power over Ethernet. Telephone lines only use one pair, they do not use two pairs. Telephone uses a multiplexing system and only needs two wires (one pair) to both send and receive. If you only use 4 wires ( 2 pairs) as described, you will only get a maximum of 100mbits speed. :)
@johnluciano51634 жыл бұрын
I was going leave a comment on POE. No reason to now.
@jspafford4 жыл бұрын
What will all the correctors do. Sigh. Why don’t people correct themselves in the description at least or redo their videos where they say something incorrect. Why wouldn’t they catch that after they said it? Or while editing? Or when previewing it before uploading it? Is this guy a complete idiot? Well reason to not hire.
@ohcrapitsmrG4 жыл бұрын
Thanks for the correction - I am trying to fix my home cat6 because the installer didn't give enough wire for keystone wall termination. Is workflow show in this video accurate enough for DIYer. It seems most people use color code B in America- Is that accruate?
@EsotericArctos4 жыл бұрын
@@ohcrapitsmrG I find the B code is used in most cases here (in Australia), but ultimately it doesn't matter as long as both ends of the cable run use the same code. A B wired cable will work fine in an A cabled socket. The main thing is that the cable uses the same code at both ends. It is best to use the same code throughout an installation of course :). The main part of the workflow and information is fine in the video. It was just the information about unused pairs that had a little bug in it :)
@jessem.52024 жыл бұрын
This explains why my 600mbps internet is only giving me 98mbps out of the ethernet wall jack. I looked at the junction box and see only 4 wires connected and the other 4 wires wrapped around the cable.
@SnackManJ5 жыл бұрын
Great video. A couple of updates to your information. The brown and blue pairs ARE used in networking for several things, not the least of which is PoE. Second, Telephone is full duplex over ONE twisted pair, the second pair is for a second line. I believe the Kevlar string is for strengthening the cable for pulling, though it is a convenient jacket splitter. The Crimp tool has two blades, one for scoring the jacket and one from cutting the ends off straight. Last, but not least, for electricians who are running the wire, be careful not to kink the wire. A kink will degrade or prevent the signals, and it is recommended that the wire be at least 12" from power wire when running parallel.
@jabado20095 жыл бұрын
To piggyback a little, when it comes to untwisting the wires for the keystone, you want to keep as much twist as possible to avoid a high NEXT(near end crosstalk). When I do these I never untwist them completely, I just unwind a small section where it will be punched and set the entire pair together. I also use alot of Panduit minicom style connectors that have a whole separate method.
@brianleeper57375 жыл бұрын
PoE is only delivered on the brown and blue pairs when the source of PoE power is a power inserter. If the source of PoE power is a network switch, then PoE will be delivered on the orange and green pairs. Which means that a PoE device powered from a switch, and for which 10/100 operation is sufficient (like an IP phone), only needs two pairs to work. I have taken advantage of this to run IP phones at 10 megabit using 3 pair telco wiring (leaving a pair free--if needed--for an analog fax line), leaving the cat5e drop free to run at gigabit speed for the desktop PC.
@philipkhung14584 жыл бұрын
You may find another video on KZbin that explain more and does the work better of terminating. With the 568A and 568B this still matters and depends on what country you are in. POE Power over Ethernet. Is used in alot of area such as cctv and also to extend the distance and signal of the cable. The kevlar ribbon / string is used to strip for more cable
@csorrows4 жыл бұрын
The string is nylon, not kevlar and is in fact for ripping the insulation.
@richardcranium58394 жыл бұрын
no kinks no sharp bends. excesses should be looped. there is a standard for the radii depending on the category.
@thetechstop38755 жыл бұрын
Here’s something I would’ve added in, and done differently. you want to keep the twist in the cable as much as possible, or else they would not certify if tested. The best way to punch down a keystone is to leave them twisted, and make a small gap with your fingernail. It allows the pair to go into the keystone Slots, and is much easier to terminate since they won’t slip out. Also, it means the twist stay in the cable
@seansmythe75435 жыл бұрын
Yes! Just started doing low voltage at work for the first time and was interesting every wire, it was time consuming, so I just asked one of our experienced Low Volt guys for a better way to do it and he said just what you said. Makes it easier and gives a better connection
@cravenmorehead87554 жыл бұрын
That's the way I do it plus I use a tool that punches all pairs at the same time. Not to mention those wire cutters he uses makes me cringe.
@JZ65634 жыл бұрын
You really should do a TDR / Bandwidth test on a completed run to prove cat rating compliance. Unlike electrical wiring which tends towards the work or “no work” conditions, data wiring has many more conditions and nuances that can greatly affect the final performance.
@H.T.2forever4 жыл бұрын
@@JZ6563 ; Whew, ... I agree ... That's why with the exception of large or medium businesses and some home office situations. For the average home I thank goodness for advances in WiFi and coax MoCA solutions today. As wiring for Ethernet, and to meet all specs, is just too labor intensive and thus expensive. ...
@thetechstop38754 жыл бұрын
I seriously doubt this guy has a quality certifier like the fluke I have. It set me back 10k, but its just a business expense lol.
@michaeldoit13 жыл бұрын
Don’t untwist pairs when doing the jacks , only for the plugs
@aaron744 жыл бұрын
One thing I've learned is that the string inside the cable, called a "rip cord", is there to literally rip the sheathing. So after you strip off like 2" of sheath, you should grasp the string and rip down another 2 inches or so... then chop off the conductors BELOW where you stripped the sheath. The reason for this is because in your initial stripping of the sheath, there was some risk you nicked one or more inner conductors. So the rip cord stripping of the sheath comes closer to guaranteeing good inner conductors.
@dawudasha9774 жыл бұрын
If you are knicking the conductors, you do not belong in the field terminating.
@aaron744 жыл бұрын
@@dawudasha977 If you use the rip cord in the cable as you should, there is much less chance that anyone--including those in the field of terminating--will nick the conductor. Thanks for your reply!
@linelinelinelinep4404 жыл бұрын
@@dawudasha977 yeah if youre not out risking $100k recabling on a 95% certainty, skill based protocol vs. a 99% certainty, fool-proof protocol youre not a "real" field tech right? fuck off
@DrD64522 жыл бұрын
@@dawudasha977 If you're not using the rip cord and stripping back you definitely do not belong in the field terminating. I can't even begin to tell you how many terminations I've had to redo behind "experienced" cable installers when networks start experiencing intermittent outages months and sometimes years after the cables were initially installed.
@rpruneau682 жыл бұрын
@@DrD6452 Then why are you? Sorry couldn't help myself...
@jeremiegrund4 жыл бұрын
A couple of tidbits to try to and help out any other DIY'ers. You want to avoid running UTP/CAT 5 parallel (next to) standard romex (considered high voltage, compared to low voltage CAT 5). Electrical wires can introduce EMI into your networking cables and cause issues. Also, with regard to testing, there is a huge difference in merely testing cable versus "certifying" cable. What is shown here in the video is a good simple test to make sure your pin-outs and terminations are correct but it doesn't actually validate that the run is capable of supporting gigabit speed.
@Sean-mc4iq2 жыл бұрын
you would have almost no interference happening even with UTP/CAT5 being side by side with insulated romex.
@Robnord12 жыл бұрын
@@Sean-mc4iq False. EMI/RFI problems caused by parallel runs of AC wiring in close proximity to data cable are well documented. Standards for separation are based on scientific testing by EE's, and available online if you are a seeker of facts.
@xphiles234511 ай бұрын
perpendicular runs if in proximity of romex. to certify cables it costs quite a bit to get the tester. ive wanted one but prohibitively expensive right now
@AEthridge135 жыл бұрын
Highly recommend the EZ-RJ45 connector. After you've stripped, untwisted and attempted to insert the conductors, on the EZ-RJ45 you can insert the conductors through the end of the EZ-RJ45, allowing you to confirm the colour orientation.
@davelavigne21333 жыл бұрын
And you need a different crimper/cutter
@JustinBallou012 жыл бұрын
As a professional in the low-volt industry, stay away from these pass-through EZ-RJ45 ends. A lot of manufacturers will void the warranty on their product if they find that you used an EZ-Jack.
@TheDrew20222 жыл бұрын
@@JustinBallou01 And how would they know? And how would you damage equipment bad enough with a bad male end to require a warranty replacement?
@neilmarsh1904 Жыл бұрын
@@JustinBallou01 Which manufacturers would those be? Pass-through "EZ" ends are where it's at (especially when your eyes succumb to a high birthday count).
@DrD64522 жыл бұрын
Phones only use 2 conductors. Always use the rip cord and strip the jacket back. Wires almost always get nicked during the score. Gigabit and PoE use all 8 conductors. When wiring jacks don't untwist the wires as the twist needs to remain as close as possible to termination points in order to pass certification.
This IS the most helpful video for a novice!! Straightforward and very easy to follow. THANK YOU SO MUCH!!
@davet67454 жыл бұрын
NEVER untwist the pairs when doing a keystone jack, most good keystone jacks have a points top for each pair, just use that to separate the pairs leaving the twist intact, place all the pairs in the corresponding slots then punchdown all the pairs. This is done to maintain the high speed of the network, do to any untwisting slows the speed down.
@xxxARBiHxxx4 жыл бұрын
what about the keystone jack, if i use the cat5 jack on a cat6 cable? is there a big difference? because... the cat6 jacks are 3 times more expensive than cat5 jack (1$ - 3/4$)
@davet67454 жыл бұрын
@@xxxARBiHxxx you can loose speed with the lower grade cat 5e jack, with cat 6 cable.
@xxxARBiHxxx4 жыл бұрын
@@davet6745 yep... but I'm not sure if the difference is that big just because of the connector...
@ThePirateGod4 жыл бұрын
@@davet6745 I've used Cat5e Keystones with Cat6A cable and use 10Gb with no speed loss. Only because I didn't have the correct jack with me. But it is not the end of the world.
@davet67454 жыл бұрын
@@ThePirateGod100mb or 1000mb a.k.a. gigabyte ethernet, then the connectors make a big difference, I have seen speed loss with mismatched connectors when testing and certifying a system. Maybe on a short run cable there might not be a problem.
@Koorisin4 жыл бұрын
Its nice to see an electrician who can actually terminate Cat 5/e/6 cable correctly. I would only add that those who are new to it, please get a proper Cat cable stripper. Also a good rule of thumb is to strip a portion of the cable off, then use the fibers inside (some cable brands use a plastic strip) to pull down and rip the cable as he demonstrated for about another 2 inches. The purpose of this is, because Cat cables are most typically 24 AWG wire, which is very thin, its easy to nick the inner sheathing on a cable when stripping the outer jacket. So by ripping the cable down another 2 inches from your initial strip, ensures that if you did nick a cable, then you are sure to get past it. (Especially if you do the bend method to brake the outer sheathing off like he does) If you do nick one of the inner jackets, then its almost a guaranteed chance the inner cable was nicked and severed. Its very easy to do. I've even seen the inner cable break in the sheathing due to over bending past the rate radius of the cable and cause signal issues over time.
@MrThinking4myself3 жыл бұрын
Love your channel. Just so you know, a phone line is only two conductors. The four pins are for locations with two phone lines. The "full duplex" capability of telephones is really quite a clever design, but it uses two conductors. Also, gigabit ethernet uses all 8 conductors, as does POE Power over ethernet. All that said, your videos are great 👍
@aredditor42722 жыл бұрын
The handset cable has 4 conductors, though.
@MyUserTubeAccount2 жыл бұрын
yes sir, ty! as a Verizon man, i was like "hmmm, so guys like him are why I'm out", and that's NOT to disparage him, he's an electrician, and smarter than I!
@MyUserTubeAccount2 жыл бұрын
@@aredditor4272 its for 2 lines. green/red in center are "line 1", yellow/black outside of that is "line 2" if you have a 2 line phone and 2 phone number, otherwise there are up to 4 pairs for a 4 line phone. or a single pair over 120vdc for a PBX system, but thats a whole other thing.
@MrThinking4myself2 жыл бұрын
@@MyUserTubeAccount or, for twisted pairs, the blue pair is line 1 (solid blue: ring, white/blue: tip) orange pair is line 2, green pair is line 3, brown pair is line 4.
@MyUserTubeAccount2 жыл бұрын
@@MrThinking4myself not on the handset cord side. it was green(tip) red(ring) on line 1, yellow(tip) black(ring) line 2. talking old Bell 2pr i.w., when cat3 came, yes, bl/or/gr/br
@Mister64 жыл бұрын
I hit the buzzer at about 3:05. Only 10Mbps and 100Mbps Ethernet use 2 pair; Gigabit or higher use all 4 pair, as does anything running 802.3ab/at/bt. Your IT content is circa the 1990s even if your Electrical content is contemporary. There's a good reason why a totally separate set of training and certification is required to legally install Cat6+ (at least in Australia) as there are many factors that matter and differ from Cat5e and below. Your tester only shows polarity, not impedance, distance or a host of other factors that go into a correctly installed cable., Cat6a+ is another story again as you have to take into account bundle limits as well. I respect electricians for what they know but believe that they should either get fully certified as data cablers or get a specialist to do this sort of work.
@jakesully54022 жыл бұрын
I fully agree that certification should be required for data installations. As an electrician I’m not afraid to admit I’m far more comfortable dealing with 600 volts than I am with 30 volts. That being said, I’ve done my own cabling at home using Dustin’s tools and techniques. All my lines work perfectly fine. I’d do same for buddies, but I wont do it for clients unless they completely understand that I’ll give it the “old college try” but it might not work and they would then have to contact a data guy to troubleshoot.
@chadhidalgo57635 жыл бұрын
The keystone has a "puck" that provides a little wider footprint for punching down and it protects the tab from being broken. It can be difficult to get the keystone jacks into and out of the puck when they are brand new, but it does help.
@uptowngregory69473 жыл бұрын
Great video. It helped me out with what I needed. When cat5 and cat6 wires need to be terminated in the industrial industry I can add this under my belt. I also appreciate all the low voltage guys giving their input as well. One isn't complete with out the other...✌🏿
@Longshot10565 жыл бұрын
Easy tip to untwist the pairs is to use that piece of the jacket you just stripped off. Just slide it between the wires of a pair. It will naturally unwind the cable without having to do much twisting. You can also then slide it over both wires, pinch them, and then pull it off while pinching. This will get the wires relatively close to each other and straighten them out without having use additional tools or risk knicking them on your shears.
@stemmentor97002 жыл бұрын
I have only seen that used recently while ¯\◔ー◔/¯ for vids for middle school kids to learn. I’m anxious to try it. Since 96, been old school and untwist by hand. Also straightening with fingers (and why I haven’t used the scissors or screwdriver to straighten wires is beyond me as I do that with many other electrical projects. Guess breaking old habits or teaching an old dog new tricks need some getting used too. Today, I do this seldom, if I need a cable at home or teaching a class 😏
@dmz69733 жыл бұрын
One thing that's helpful to untwist the wires, is to use the sheathing you just pulled off the cable and run it down in between each of a twisted pair.
@@ronaldnolasco7792 what is that supposed to mean?
@jeffm27874 жыл бұрын
Keep the twist as much as possible, it's an balance pair where the twist on the two conductors balances the inductance and capacitance to keep the impedance where it needs to be. Not to mention common mode rejection of the twisted pair. Untwist and you create an impedance lump. So keep it twisted as much as possible. Yes someone can come by and say that's not precisely right, feel free.
@steveclark9852 жыл бұрын
Absolutely correct.
@stevenholton4382 жыл бұрын
Ahhh so it's impedance and inductance! Interesting how this produces the desired effect! Anyone care to elaborate to save me searching? 🤔
@azr2d15 жыл бұрын
also, gigaBIT ethernet uses ALL 8 WIRES.
@tylersmith98684 жыл бұрын
I believe some of them are for POE.... Power over ethernet
@isaacbull86534 жыл бұрын
Pins 7&8 are POE
@FlaxTheSeedOne4 жыл бұрын
@@isaacbull8653 And 10g uses all of them cuy poe is not possible with 10g over copper
@CarsonSuite4 жыл бұрын
Haha give him a break we are the nerds haha he is probably installing for standard use
@Kaleeb424 жыл бұрын
@@isaacbull8653 I thought the same but regular POE can be carried over only the orange and green pairs (pairs 1 & 2, 3 &6) for 568B. I only know this because I've been able to get Cisco 3602 WAPs online using 2 pair hydra cables. All this tells me is that I don't understand how POE works. Or Cisco does something with their switches where POE is sent on all 4 pairs, so whatever end device you are using can get power over any pair.
@saltyroe31794 жыл бұрын
The string in the cat5 cable is a strength member. It is common to have strength cords in cables that will pulled or hung and where the conductors on not strong enough to hold things together.
@jim7smith4 жыл бұрын
I was going to mention that the string was mainly for pulling the cable through conduit, but no need now that you have done it...
@tonyrobbins64 жыл бұрын
FYI: the brown/brown white is used for POE. So if your using something like an IP phone or security camera, some will/can derive their power from a switch via POE, so if you mess up the brown/brown white wire and ignore it, though it will not affect a computer, it will not provide power to a phone or camera.
@alant57573 жыл бұрын
You forgot pins 4&5 the blue/blue white pair…. It too is part of the POE . That is of course.. if you are using anything POE
@DoYouDJ2 жыл бұрын
I was looking for this info and bam it is here lol.
@geraldreeve64034 жыл бұрын
I was told by my data teacher at the university that he was on the team that AT&T sent to the standards conference, when the conference established the 568 standard that we know today as 568A Att objected because they had already established their own standard (258A) and objected that it would not be the standard, the end was to have both an A and a B standard to accommodate AT&T. The pairs are also important, Pair 1 the blue pair Pins 4 and 5 on a 568 cable initially carried a standard telephone line. Pair 2 (the orange pair, pins 1 and 2) was transmit data and pair 3 the Green Pair, Pins 3 and 6 was Receive data, a crossover cable was for connecting equipment such as two switches (both expect to transmit data on pair 2) together, the crossover was to crossover transmit to receive and receive to transmit. Pair 4 the brown pair was unused. We could make two network connections by creatively using the blue and orange pairs for a second connection. AT&T also was using 258A for their telephone systems that had (hybrid) telephone sets and used one pair for voice (pair 1) another pair to send data to the telephone set (lights, date/time etc) and a third pair to send data from the telephone set tot he phone system (digits dialed, buttons pushed etc. ) and the last pair for power. as the systems got more complex the need for 4 pairs dropped to 3 then 2 and finally 1 pair. the telephone techs had to know a bunch of standards and how they worked.
@giovannimercuri51685 жыл бұрын
The male ends are always a pain..but, a while back, I started using the pass through ends. I know for those that have been doing this forever, they will call that cheating and are used to the systems demonstrated here...but, the pass through are just as good...and they are way easier (and more importantly, faster) to get terminated.
@orcoastgreenman5 жыл бұрын
With the pass through you can also pull the untwisted portion all the way through and thus maintain the twist of each balanced pair as close to the compression/piercing connection of the gold pins at the end as possible.
@Ressy665 жыл бұрын
well, " just as good " is yet to be determined, I'm a little concerned for those in high humidity areas, oxidization on the exposed and unprotected ends.. Even the folks at Ideal say its a "wait and see in 5 or 10 years time" type thing as to how being exposed affects them.
@T6Tarek5 жыл бұрын
@@Ressy66 I admit I use passthru ends it's too easy and I can make 10 patch cables in the time I can make 1 standard style end. Haha. On exterior projects, outdoor A/P, security cameras, ETC i have started just putting the faintest amount of dielectric grease on the exposed end, I have been doing it for a couple years and have had zero issues, call backs, down time. When doing routine maintenance nothing looks abnormal. I live on acreage and have zero cell service so I rely on wifi. I have deployed the same methods at my own home without fail well except cutting a direct bury cable in half that was over a 100ft run lol.
@Ressy665 жыл бұрын
@ Tarek Now that's a neat idea, I might make a couple (supplier gave me bag of 50 once when they were new to them) and dab the ends of some, and some not, then just wait and see in 6/12/24/+ months if there's a difference. We're in a hot and humid climate, near ocean, so a good test to see how they hold up. I'll do some inserted, and some "spares" that are truly exposed to air. (Ohh and I know what you mean about time to make normal, my hands are not that small, and its a PITA to keep them in order sometimes :)
@neilmarsh1904 Жыл бұрын
The older my eyes get, the better I like pass-throughs.
@azr2d15 жыл бұрын
On the keystone jack you are not supposed to untwist them all the way. The more twist left behind, the higher the signal quality.
@dr_kellogg5 жыл бұрын
It makes no difference.
@lqdxoni15 жыл бұрын
Damned sparky stay away from my work.😜
@dr_kellogg5 жыл бұрын
@Default User a quarter inch is something that is literally impossible to test for, get off your high horse.
@SuperSetright5 жыл бұрын
@@dr_kellogg , ''a quarter inch is something that is literally impossible to test for''.......I would have to agree.
@Truevisionsolutions4 жыл бұрын
Get a tester and test and the the loss you get and you will see. It makes a difference!
@nazgullinux66012 жыл бұрын
It literally does not matter what order the colors are in. As long as they perfectly match on each terminated end. The device with the network port isn't going to flip out when a green is in the normally blue/white pin location. Its just copper wires. Ensure each wire is in the same location on both ends and the colors won't matter for anything but for nitpicking purists. the actual conductor pads on the rj45 jack lets you know which signal line it's using. Keeping the 568A or 568B config is just for those that don't know the above info.
@AquariumThoughts4 ай бұрын
Yes & No. Will it work? Yes, but you are asking for trouble by not following standard practice. You are opening yourself up to making errors. Not only that, let's say down the road you need to fix one keystone termination. When you go to fix it, you are going to need to remember whatever janky order you used. It's best to just follow the standards to avoid such messes and doesn't make anyone else who might work on it pull their hair out.
@kylelikeskjvbible5 жыл бұрын
I love these videos Dustin. They're great for someone like me who never worked on these before and is expected to know what I'm doing while in class when we had no prior instruction. Its just like read schematic and go, no lesson.
@justinsouthworth17835 жыл бұрын
Way to be humble!
@kylelikeskjvbible5 жыл бұрын
@@justinsouthworth1783 I am. I know my limits, and I'm just trying to learn.
@BlastarX4 жыл бұрын
This Video explains the reason why companies hire network technicians to do the network wiring and not electricians.
@skynetlabs3 жыл бұрын
EXACTLY! I can spend the next 100 years fixing electrician's low-voltage/networking attempts.
@jlowbag3 жыл бұрын
Exactly I took electrical and network cabling teq I can see that it isn’t terminated correctly
@arneanka46333 жыл бұрын
And my experience says that electricians always need to clean up after network techs after they were climbing around all our conduit messing up absolutely everything. So the best thing is to have the electricians pull the wires after some instructions and then let a specialist terminate them. Absolutely not one of those guys dwelling in an office clunking a keyboard all day long. They are the worst and should not be near a site until the switches are to be but in. Not even patching is done right.
@pn1023 жыл бұрын
Yes, second I saw the headline I said oh crap, electrician who needs his balls busted for playing data guy. Sure enough this guy makes every mistake in the book. Worthy mention to some of the other comments, unless the data guys were formally trained, it’s just a flunky IT guy who thinks he knows how to run and manage cable.
@pn1023 жыл бұрын
@@j2o3shI see a lot of messed up cable plants and others that make you scratch your head wondering how much $ and time was poured into the pristine detail work. And when I see things like that, I respect the tradesman’s efforts but it usually begs the question of how much planning and thought was really poured into it, and at who’s expense. If its beautiful but lacks forethought, it isn’t adding value. It was a data guy taking someone for a ride. Usually I’m brought in at a directors level to clean up someone else’s mess. There is a vast difference between being highly trained vs understanding requirements, client needs, and seeing around the corner for whats coming down the pike. My perspective in unique in this way. What I saw in this video specifically was the typical electrician, using subpar data products for their install demo, untwisting pairs, crimping riser cable? I mean come on. If I see crimpers anywhere, they are promptly thrown in the trash. There are many different ways to skin a cat, and in the data world, there are many different ways to install cable. Some of them good, some just okay, and many bad with little forethought. These overall mistakes are repeated over and over and over again. And it makes me wonder. “Why” I already knew what I was about to see before I watched this video. It didn’t disappoint. Do not use riser - Industry Certified Plenum Only! And use the higher MHZ rated stuff. Plenum performs better. Crimp Nothing or Be Crimped. Use a keystone and biscuit. Hey you can label it, imagine that. Crimps Create a point of failure. Use ICC keystone jacks. They make an install Mitt for them. The pairs are in order. Why make the job harder? Use ICC EZ Panels rather than patch panel. Color code it! Smack the IT guy when your done and provide 1ft booted patch cords, color coded, matching the brand of your keystone. (It matters) the products were designed as a system by engineers. T568B Only - A was an old AT&T standard. Why create any confusion on a site? Why would anyone even suggest that? All pairs are used with 10/100/1000 and POE standards.
@dr_kellogg5 жыл бұрын
Senior sys and network engineer here, came to watch an electrician terminate cat cable and was surprised by how much he did right! Kudos bro! Didnt use pass through rj45 ends!
@cravenmorehead87554 жыл бұрын
I always use passthrough, it annoys me to no end to re-terminate.
@dr_kellogg4 жыл бұрын
@@cravenmorehead8755 just do it right and you won't have to reterminate
@joshuasmith44312 жыл бұрын
Feed thru RJ-45 modular plugs are the way to go!
@patmanwainwright34234 жыл бұрын
Hey mate you got the basic there just would like to say the blue pair is for voice and the brown pair is power eg cameras use POE power over Ethernet which is the brown pair WAPS in buildings also use POE. Also with the male RJ45 it is best to put the rubber protector on which you see on you testers jumpers these protectors help stop the cable wires from breaking up close to the RJ45 crimp. Now as for A & B A is the Australian standard and still used heaps in Australia but you are correct as long as you wire it the same both ends it will pass and work anyway I enjoyed you how too it was good hope this helps you or someone reading comments and keep up the goo work
@dalefirmin51183 жыл бұрын
To say that the Blue is for voice and the Brown is for PoE is wrong. PoE uses the outer pairs of wires for 802.3at and 802.3af but uses all for pairs for the 802.3bt. (NEVER is less than two pairs used.) This is the Orange pair and Brown pair for EIA/TIA-568B. If you use Cat5e wire with RJ-45 for POTS, then the Blue pair is line 1, Orange for line 2, Green for line 3 and Brown for line 4. (It spells BLOG with the Brown pair last and understood.) This order is the same in your 66 block. www.black-box.de/en-de/page/23894/Resources/Technical-Resources/Black-Box-Explains/lan/PoE-in-Networking There is a lot to learn in proper networking that cannot be covered in a 25 minute KZbin video. Unfortunately, there is a LOT of misinformation put out on these videos and especially by user comments. There are several good certifications for network cabling, such as BICSI being tops and some vendor certifications like Fluke. The LOWEST certification level requires about 50 hours of classroom training followed by a two-hour written exam and hands-on testing.
@shahzadhaider9195 Жыл бұрын
Nice man , good explanation , your video is much appreciated , it helped me
@DrummerDude56455 жыл бұрын
Stick a small precision flat head screwdriver in between the twisted pair wires and slide them apart. Its so much faster than twisting them apart by hand. Just a little tip.
@WLRJ34 жыл бұрын
Bingo! And use that to straighten them as well.
@joshuawolfe77634 жыл бұрын
or use the jacket that you just stripped off to untwist....most of the time I don't untwist at all unless its going into male rj45....
@RCRoads Жыл бұрын
It's critical for electricians to know how cat cable is terminated and tested. I'm retired now but as an electrician you will open more doors of opportunity. Cat cable is used for TV's, Surveillance Cameras, N-light wall pods and so much more. I was never that good at terminating RJ45's but when I started using the pass throughs it was real easy to do. Thanks for sharing. Sharing is caring.
@DLexEdition5 жыл бұрын
Actually, the other 4 wires on the Ethernet cable can be used for power delivery via PoE standards and injectors, if separate from your router, bridge or switch. Here's what I'm talking about: planetechusa.com/power-over-ethernet-poe-demystifying-mode-a-and-mode-b/
@OVCArchion2 жыл бұрын
That's a good point on the TIA-568 A vs B. In datacomm these days we are always using B. I still run into old Bell system guys that use A because that's always what they used. One of the first times I worked with one of the greybeards, he was punching down in A at the patch panel and the rest of us were punching down in B out at the jacks. Luckily we caught it early after only like 10 drops had been punched, another win for safety/slack loops. Also, for my experience in 15 years I've never had the need for the strippers and found them a little bulky. I've found a nice set of electricians scissors to be easier to use and handle on big jobs.
@TheDrew20222 жыл бұрын
A vs B is a debate that's been raging for a while. I personally use 568A as it's compatible with 2pair phone wiring, but end of the day whatever my customer is using on premises is what I work to.
@terry60205 жыл бұрын
UTP = Unshielded Twisted Pair
@tylersmith98684 жыл бұрын
Basically indoor Ethernet cables
@Demon09-_-4 жыл бұрын
Using shielded cable unless you have equipment that supports it can do more harm then good. Utp should be used 99% of the time for normal users,unless you know you have grounded equipment
@johnsilva50204 жыл бұрын
Yeah, I cringed when he said Universal
@dhansel48354 жыл бұрын
I buy the EZ45J plugs so I can pull each wire through the plug. When I crimp them down the crimping tool I use cuts the excess wires off. The wires are hard for me to see so I put on a head mounted magnifier which makes things BIG.
@dmlagoon4 жыл бұрын
Thanks so much. I'm about to wire our house with Cat6 and this was concise enough to get me going. Now I know what those strange tools are for!
@buzzsah3 жыл бұрын
@@RolandWartenberg True, I get it done over time when I can see the parts.
@dbetts30874 жыл бұрын
Punch down has HIGH/LOW impact for a reason. You always you low on any plastic punch down block and high on all metal punch down blocks. The low is so you don't break the plastic connector
@michaelm.69555 жыл бұрын
Never let electrician wire or finish the cabin or rack. 50% of time we always have to return and rip it out.
@philipkhung14584 жыл бұрын
If the work is done good and tested properly then you would not need to return to. I do agree with you that over the years as a electrician I have seen dodgy work.
@keithwilliamsWilf4 жыл бұрын
What you mean to say is that half of the problems you have encountered have been to poor installations by electricians, that does not mean half the networks installed by electricians are bad. Yes there are poor data installations but not all of them have been carried out by electricians there also also data bad engineers, or are you saying they don't exist? Having worked in both industries I think that two day course is long enought to learn all you need to know about data networks, the rest is experience in wiring and containment installation, knowing how to create a route and the best method in wiring to it to conform to wiring regulations. Not just throwing a loom over a suspended ceiling often passing straight over a florescent light fitting (when they were more common) which I have witnessed on many occasions. The bottom line is it really is'nt rocket science and a half decent electrician will get a hold of it very quickly because cabling is a good part of our trade.
@michaelm.69554 жыл бұрын
@@keithwilliamsWilf it's just my two cents. 25 years in the telecom / IT field , in the Bay area and as a owner of one of these these businesse. That's the data that I've concluded.
@RyanH08092 жыл бұрын
I was just trying to learn a bit about this stuff to test my cat6 jack that isn't working in my office. Although i've pretty well determined that i'll just wait for our data guy to come and inspect/repair it, as a student of many things, i found this super interesting and well-taught. Good job!
@marciethomas73714 жыл бұрын
Ops the first ops. I love your videos so far. Telephones only used one pair, the blue white pair. I spent 30 years doing and started to electric work in 1960, yes I am that old. Second have you ever used the pass-thru RJ-45 plugs, I wish I would have years ago. But, the pass-thru you do not cut the wire, they pass-thru the plug and the crimper will gut the wires flush.
@sixteenornumber4 жыл бұрын
"Gigabit" not "Gigabyte". Byte is denoted with a capital B while bit is denoted by a lowercase. For example, 1GBps vs 1Gbps. 1 byte = 8 bits so a 40Gbps = 5GBps. This gets more complicated when considering that there is overhead date on top of the real data being sent (data vs information) so it's easiest to just use bits when referring to network speeds.
@NevergoldMel3 жыл бұрын
Dude, it's silly to preach computer science to Electricians.
@themountofoliveschannelwit70095 жыл бұрын
27 years in the Electrical trade, For the last 5 or 6 years I have done far more datacomm work than I do regular electrical work these days. Not on purpose, it has just worked out that way ((((( Just a tip, You can buy one of those FLUKE punchdown tools at OfficeDepot for much cheaper than what they cost at a Electrical supply store. Why OfficeDepot is able to sell those for so much cheaper than everyone else, I don't know how they're able too, but they do. ((( One of my co-workers told me about them being cheaper at OfficeDepot is how I found out, I didn't even know that OfficeDepot sold Fluke products until he told me. (they don't actually stock them in the store, but they will order it for you, takes 2-3 days for it to come in)
@luvdady4 жыл бұрын
get a set of klien punch down you wont be sorry so much better then a lot you can catch a combo pack at times and save big time
@jopo63882 жыл бұрын
Love your channel but never untwist the punch down end. It’s actually easier to leave them twisted and place a partially opened twist over the punch down ramp on each pair. Faster and better bandwidth
@steveclark9852 жыл бұрын
Exactly.
@colinstu5 жыл бұрын
Could talk about shielded / unshielded, plenum rated cable, exterior cable, etc.
@CarsonSuite4 жыл бұрын
Colin Stuart good idea for another video
@CarsonSuite4 жыл бұрын
@Rezheer Kirkuky it depends on the application. If I never run less than cat6. If you are around hvac and air passageways you are required by code to run plenum because it is smoke/fire resistant and obviously you don't want smoke or fire around oxygen ;) If you need higher data rate like 10g ethernet i would be running cat7 or better. If you have long (300+ ft) cable runs maybe cat6a minimum for example. It all depends on the application.. if you are running cable between levels of a building.... you would by code need "riser" cable which is a very common form. If network cable is not rated it is for general purpose runs on the same floor and not to be run though walls.
@gusc67854 жыл бұрын
@@CarsonSuite what would you use for outdoor ?
@CarsonSuite4 жыл бұрын
@@gusc6785 they make a outdoor version of all of these cables.... if you are linking buildings i would recommend cat7 (but really fiber) but if its just to a device (camera or rf device) cat6 would be perfect :) All depends on the application tell me what you are doing and I might be able to give more insight :)
@gusc67854 жыл бұрын
@@CarsonSuite just PoE cameras residential, longest run approx.. 190ft. Some will be exposed to weather but very small section of it.... 2 of which will be in raceway underground. ( do you recommend metal or pcv for raceway)?
@jerzy8536 ай бұрын
Men, I'm watching your wonderful schooling and helping on and off for a long te now. We need you and your wisdom Never stop , keep on going - you are truly amazing bro! Thanks for allcyou do .
@thejpkotor4 жыл бұрын
I thought he was going to get to further standards than just CAT5...
@danielawe834 жыл бұрын
I thought the same.. No shielding at all
@danielawe834 жыл бұрын
The real challenge comes with CAT7A (not only the cables but also Cat.7 A capable Jacks like GG45)
@paulphillips6754 жыл бұрын
Just as well he didn’t move on from Cat5 ‘cos he obviously doesn’t understand it
@raiden724 жыл бұрын
@@paulphillips675 some electricians have been known to botch up network cable installs because they are borrowing knowledge from the RJ11 days, I've seen phone splice connectors being used inside of ethernet installs (really bad!) This is why people pay for a proper network guy such as Cisco certified to get things done right the first time
@rcnitro0012 жыл бұрын
You made this look so easy. My son has been asking for a cable connection in his room for his tv and laptop. Wi-Fi is too slow for downloading he said. Now I know how to connect these plugs. Nice video
@markseven60464 жыл бұрын
Thanks for the video man! You missed a good opportunity to do a over the shoulder first person view when you were explaining the termination. That little bit of “my left, your right” will add a little bit of frustration when trying to learn an already tedious task. Thanks again for the help
@Koorisin4 жыл бұрын
Second comment when terminating keystone jacks is that you want to maintain the twist as long as you can. This means keeping the pairs twisted all the way up to the punch down terminal as best as possible. You also want to keep all the cables as close to the same length as possible which means instead of laying the cable at 90 degrees to the block like shown here, you want to come straight in on it. The same goes for punch down panels as well. You can see that the keystone cap is designed for the cable to come straight it at it. Never bend the cable back up afterwards either as it will pull them loose. When taught this, it keeps cross talk down. The proper standard is to keep the pairs twisted always, use a pick tool (looks almost like a dentist pick but plastic) and separate a small opening between the pairs where they need to connect in the punch down. Since keystone jacks and punch panels always keep the pairs together (only crossing the connections internally as needed) this makes the best for least cross talk. Cat cable is so fine and the more cable exposed from the outer sheathing, the more the potential for cross talk. This isnt as bad in 10Mb/100Mb and even most 1000Mb configurations but def a must for 10Gb and higher. In fact cabling for them are sticker and have shielding internally to the wire as well. A proper 1000$ tester will pass the connections shown here for but report they have cross talk and reduced signal strength even though they make connection and are wired correctly per color code.
@velocityacoustics4 жыл бұрын
Some keystones from reputable companies, come with instructions showing to lay the cable at 90 degrees and bending the cable back up.
@Koorisin4 жыл бұрын
@@velocityacoustics You should never bend the cable after termination as it can and will cause the termination to pull lose. Also when coming out at a 90 degree, you cannot guarantee each run is of equal length which is something you should always attempt to maintain is equal length cables from the sleeve. You cant trust the producer of a key stone jack over industry standards.
@velocityacoustics4 жыл бұрын
@@Koorisin I agree that terminating the wires straight into the keystone is the right "by the book" way. But I can tell you that in the real world, chances are it will not make a difference. These things are not that fragile. They designed for the rigors of installation. Think about when you are installing a keystone wall plate. You don't think that pressure is exerted on the wires? The IDC connectors have a very firm grip on the wires, plus with the snap on cap, that wire is not going anywhere. You would have to be very forceful with the wire for it to come loose. As for equal length of the wires, that minute amount of wiring is insignificant in 90 percent of installations.
@Koorisin4 жыл бұрын
@@velocityacoustics I do this stuff every day. I can show you our new building where lazy installers did the same thing and upon pressing the wall plates back into the wall and tieing them down, we had a number of them come lose. Most on the blue/white
@azr2d15 жыл бұрын
it's called a ripcord and you are supposed to use it otherwise there is a chance you nicked the wiring when you took the insulation off.
@tzd19174 жыл бұрын
only noobs use ripcords
@joshuawolfe77634 жыл бұрын
@@tzd1917 lol I don't even use strippers or ripcords.....i just put a nick the shielding with my scissors and it snaps right open.....
@tzd19174 жыл бұрын
@@joshuawolfe7763 #metoo
@cat6cableguy814 жыл бұрын
@5.56 Bear Yeah, I just use my snips. Never had an issue nicking wires.
@nelg702 жыл бұрын
I'm Glad I went to cabling/fiber school in 2001 to learn all the theory behind this.
@benosborne58425 жыл бұрын
I wish I could like this video twice. Just what I was about to search for.
@mcgameing15 жыл бұрын
just to add something , one of the twisted pairs he mentioned not being used can also be used as POE (power over Ethernet) and can be used to power things such as CCTV cameras ect. great vid!
@thetechstop38755 жыл бұрын
Send, Recieve, Power, Future
@AnthonyP2A4 жыл бұрын
Would have been great if you linked the tools you used, so we could "assemble" our field kits.
@AlGoYoSu4 жыл бұрын
Instead of untwisting with your fingers, try this: take a small flathead screwdriver, stick the screwdriver between a pair, and pull the twist out. They will be completely straight except for the tip which you can then cut off. The best ($) connectors for efficiency are EZ RJ45 connectors, along with their crimpers. The connectors are open on both ends so you don't have to cut the wires down to length, they just pass through the other side. The crimpers have a blade on it, so when you go to crimp, it cuts the excess wire off for you.
@robertharker4 жыл бұрын
This is a great CAT5 termination video. Your clear explanation and great closeup of how to lay the wires flat for interesting in the RJ45 plug are excellent. But this is not a "CAT6, CAT 7, CAT 8" video. These higher cat levels have much stricter termination requirements and use different physical RJ45 connectors. Once you go above 1 Gbps, a more sophisticated Ethernet analyzer is a must to verify the performance of the lines. Something more than a simple continuity tester like the LAN Scout Jr.
@saltyroe31793 жыл бұрын
The unused wires act as shielding and increase external signal rejection. As has been noted by others the string is for strength, not to take jacket off. A vs B. As long as both ends are terminated the same way, you will get signal. B is theoretically better than A for outside signal rejection, although in practice, how well you do the termination is more important. Remember that twisted pair is a cheap substitute for coaxial cable. Also termination of coax is more difficult
@NevergoldMel3 жыл бұрын
Coaxial ethernet died in the 90's, let it go.
@Rick-kv3gl5 жыл бұрын
The pairs should remain twisted as much as possible
@electricaltouchmaltasmarth5144 жыл бұрын
www.electricaltouch.com cat5 cat6 cat6a Malta network utp cable for cctv and network
@TroubleChute2 жыл бұрын
12:53 Timelapse music goes hard
@TheDrew20224 жыл бұрын
I think the biggest thing that electricians should take away from any training they get on how to run CATx cable, is bend radius. Network cable is NOT doorbell cable, you can't bend it around a 2x4 like you can doorbell cable, it needs a gentle bend (1" radius at the absolute minimum) otherwise you'll damage the cable internally and guys like me who work with this stuff for a living will come behind you cursing at the (expletive) sparky who forced me to re-pull a cable (always fun behind drywall) because it wasn't installed correctly. And if you really want to make us datacom guys happy (sing your praises) when doing commercial rough ins, run some 1/2" or 3/4" conduit into an outlet box so we can do our pulls easily. You know what it's like to fish MC through finished walls, we don't like it either. :-)
@stemmentor97002 жыл бұрын
Lol. You got that right. Bends were one thing. Having staples driven through the cables and trying to hide it was annoying as heck. Made my electricians pull a whole new 200’ run for not telling me. I could have fixed where it was (micrscan tester is awesome for detection and where). They needed the practice. And we had a saying in the Navy. “ never enough time to do it right the first time, but ALL the time in the world to do it over and over. Plus I was doing installs and first stop was Pearl Harbor. Was in no hurry as it was winter time 😏
@TheDrew20222 жыл бұрын
@@stemmentor9700 I have a cable certifier (not the expensive $5000 Fluke model) that can detect shorts or cuts, and uses TDR to determine length so I can estimate where the break is. Always at the point where there's no slack anyways, so gotta pull a new run.
@Mestman32 Жыл бұрын
Crimpin’ ain’t easy, but you make it look so easy. Thanks for the lesson!
@padraics4 жыл бұрын
"Unshielded twisted pair" come on bro you get the name of what you're talking about wrong in the first sentence??
@falconwings69942 жыл бұрын
Amazing. I never knew the reason for the specific wire twist was to separate or eliminate cross talk. I assumed the plastic center strip was there to space the wires farther apart. This also explains why I have spliced signal wires in the past and they didnt work... all because I untwisted the wires and left them straight or the 2 wires joined together had different twists. (all about the details!!!)
@DrorF4 жыл бұрын
12:53 This is the worst tutorial-music I have ever heard! 😖
@beatmakerbrown3 жыл бұрын
I want to hear it at a rave
@tonygawel94 жыл бұрын
I am a certified installer for several different manufacturer's there is a difference with tia 568a and b. You should not mix the 2 when running Gb speeds. Also use the specialized for proper termination
@wmcomprev4 жыл бұрын
While you can strip the way he shows, I would recommend getting a stripper designed specifically for this. It's cheap and MUCH easier.
@curtflirt24 жыл бұрын
Got any recommendations??
@wmcomprev4 жыл бұрын
@@curtflirt2 Just try Amazon.com and type in "Cat5 Stripping Tool" in the search box. Pick the one that looks the easiest for you to use. The one you get should be adjustable, not all cable is exactly the same diameter. Even though I typed Cat5 above, it works for Cat6 also.
@TheDrew20224 жыл бұрын
@@curtflirt2 I use this one all the time at work as I do a lot of CAT 5/5e/6 cabling at work. A lot of other's one's cut too deep which nicks the inner insulation. Only time I use the deeper cutting ones are when I do outdoor cable rated for direct burial or overhead (aerial) runs. The jackets on those are thick. www.platinumtools.com/products/strippers/twisted-pair-strippers/cat-5-6-cable-jacket-stripper-15015c/
@curtflirt24 жыл бұрын
@@TheDrew2022 okay, cool, thanks
@bowlsofjelly70302 жыл бұрын
Thank you!!! This is the BEST video I've ever seen on this subject!! Great job.
@cravenmorehead87554 жыл бұрын
He's a typical electrician, does everything caveman style.
@glasshalfempty19844 жыл бұрын
Dude, this guy is a pro and does things as clean and as well done as humanly possible. Structured cabling just isn't his profession, he's an electrician...but I'm guessing electricians sometimes do this work. Unless they are very knowledgeable on both fronts, however, it's not something that they should be doing. But your remark was completely unfair, not even remotely accurate, and uncalled for.
@raycurci4 жыл бұрын
Analog voice, aka B1 lines, use a single twisted pair (2 conductors).
@tyler39934 жыл бұрын
yes, the 2 pair is line one line two. he fucked that part up. same thing with the orange pair and green pair one is transmit other is receive.
@florianbayer20545 жыл бұрын
my boss would cry out loud...
@wildchak4 жыл бұрын
LOL
@rolanddibb4175 Жыл бұрын
analog telephone uses a 4pin or 6pin connector (RJ11) - but telephone only uses 2 wires per phone number / line . green/ tip = positive red / ring = negative most cables have 4 wires so here is the other 2 colors that are generally not used unless you have a second telephone line in .or used for return to house phones in line seizure for alarm systems / emergency phones. yellow / tip2 black/ ring2
@Xxjoker21xX4 жыл бұрын
You are incorrect about networking not using all 8 wires , in half duplex what you say is true but now most connections are Full Duplex and it uses all 8 with twice the throughput!
@Teampegleg3 жыл бұрын
Half duplex and full duplex still only used 2 pairs. Gigabit is when they started to use all four pairs.
@itchyblanket55082 жыл бұрын
Do keystone jacks reduce speeds or ping? I have fiber running to my modem in the garage, then a 20-foot ethernet to a keystone jack, then a jumper(small Ethernet cord) to the router, then another 30-foot ethernet to my Xbox. I'm trying to get the lowest latency possible. Does the keystone jack make a difference? Is cat8 overkill? Any help would be awesome, you seem very knowledgeable on this stuff.
@user-ub4ok2ze8n4 жыл бұрын
This comment section. "IT'S xxxxBITTTTTTT!!!"
@starlite5282 жыл бұрын
Yes all four pairs are used! In Gigabit ethernet and PoE. In the "old days" 10/100mb only needed the two pairs
@PrimeRsoul5 жыл бұрын
Pro Tip: Don't tell your wife/girlfriend that you ordered a stripper. Thank me later.
@cravenmorehead87554 жыл бұрын
I did but thankfully I'm happily divorced now!
@bobstalnaker97064 жыл бұрын
Order two....in the event you lose one.
@Wranorn2 жыл бұрын
"A" is not older, "B" is just took hold because the color coding was similar to AT&T 258A specifications. Crossover cable is 568A on one end and 568B on the other, so while it DOESN'T matter which one you use, you DO need to use the same termination on both ends (Unless a crossover connection is wanted). National phone system operates on 1 pair (2 wires). (A PBX might use 2, 4 or 6). Don't untwist the wires, the keystones you have, have a point to push the wire twist down onto to separate the twist, keeps the wires more manageable too. If you have to untwist THAT much for other purposes, run a straw on one conductor in the twist, it'll separate them. And always use the rip cord, especially if you just pulled the cable.
@lqdxoni14 жыл бұрын
Ok sparky back away from my low voltage and stay in your lane.
@padraics4 жыл бұрын
Haha I know right
@hungrynapps4 жыл бұрын
I swear this cross my mind. Lol
@Hewagej2 ай бұрын
Nice video thanks ❤
@whelenguy4 жыл бұрын
Industrial Electrician here, and even I had to stop watching when he said phones use 4 wires to work... only 2 are used Tip & Ring...
@paulpoco224 жыл бұрын
Yes I jumper 2 wires(pair) everyday on the Central Office Frame.
@davidj8984 жыл бұрын
If you are using a business phone it can 2 wire/1 pair 4 wire/2 pair or if an older system 6 to 8 wire/ 3 to four pair. If you're using VoIP with PoE then all pairs of course. Done them all!!
@whelenguy4 жыл бұрын
@@davidj898 Well i was referring to the service providers. As far as I know the vast majority of all them are a pair to supply unless they are VOIP. You are talking about PBX systems and even "old" pbx systems like nortel which are super common only use 1 pair... and I know other digital / analog systems line panasonic, AVAYA, and so on only used a pair.
@timezonewall4 жыл бұрын
@@davidj898 He said one pair to send the voice, and one pair to receive the voice (utter nonsense). Clearly he was talking about a single analog POTS line, which uses one pair, Tip & Ring. Much of what he said was either incomplete or just plain wrong.
@orcoastgreenman5 жыл бұрын
One thing I didn’t notice covered in this video is that most RJ-45 plugs (male) are made for use with stranded patch cord cable, and most RJ-45 jacks (female,) are made for solid conductor cable. Using any of these with the wrong type of cable for the connector design, often resulted in flaky, intermittently unreliable, or non working connections.
@orcoastgreenman5 жыл бұрын
Generally, in practice, solid conductor cable is used from high density rack mount RJ-45 female patch panel ports at data centers, to wallplate, furniture plate, or surface mount box RJ-45 jacks at the “work station/user endpoint”
@orcoastgreenman5 жыл бұрын
and stranded patch cord cables with male RJ-45 “Ice Cube” plugs are used at the data center from network switch equipment to patch panel ports, and then another patch cord of suitable length at the workstation end. It was almost NEVER cost competitive for us to make patch cords for customers, over buying prepared ones in suitable lengths from the same vendors we bought the solid conductor in wall cable from, and the female jacks we installed on the cable after running hundreds or thousands from data centers to workstation outlets.
@briankirkland96824 жыл бұрын
I can’t watch any more of this.. seriously I’m sure he’s fully qualified as a high volt tech, but do not follow his technique for cable termination. Use ripcord, use snips, or let your telecom/ network guys finish the termination. If you score without using the ripcord I’ll be charging you to reterminate your jack/ patch because after 6 mos the cable will fail
@VideoNOLA4 жыл бұрын
Came here for this comment. ♥
@myshots1015 жыл бұрын
FYI. It does matter if you have A VS B connections. Troubleshooting this is no fun if you are not familiar. I had a contractor making a building and I had specifically said to use cat6. One morning I came to work to find that they had wire everything cat5 when I had been using cat6 to rewire the old building I was in. We were also doing a new phone install which came out very nice in the old building. The phone company guys did the work. Let's just say the contractor also decided to do the phone wiring in the new building to get the money and when the phone company guys saw the work, they told me that wasn't the way to do it. It may have worked but if you want to really piss someone off that's the way to do it. Ask those who know before doing any type of work if you're not familiar with something. Just my two cents.
@gauntletwielder63064 жыл бұрын
Wow!!!! *DO NOT WATCH THIS!!!!* I had to stop watching as soon as he said that 4 of the wires do not do anything. WRONG. Gigabit Ethernet and Power over Ethernet (POE) use more than 4 wires. At the beginning, he said universal twisted pair... the U in UTP stands for *unshielded* ... not universal.
@timezonewall4 жыл бұрын
It's filled with errors and nonsense.
@antonfloor3444 жыл бұрын
You do only use 4 wires, the other 4 are for phone and Poe
@timezonewall4 жыл бұрын
@@antonfloor344 Most installations today use 1000base-T which uses all 8 wires for data. Go read up on the IEEE 802.3ab standard over unshielded twisted pair. In short here is the pinout: 1-BI_DA+, 2-BI_DA-, 3-BI_DB+, 4-BI_DC+, 5-BI_DC-, 6-BI_DB-, 7-BI_DD+, 8-BI_DD+. POE is piggy backed with the data, there is no support for analog phone. 20 years ago, your statement would be true with 100base-TX, but not now. The author of the video is has only limited knowledge of data cabling and is not a good source of accurate information.
@johng.4 жыл бұрын
And yet he took as much care to lay out all four pairs, just as if they do make a difference ...
@timezonewall4 жыл бұрын
@@johng. All the wires do make a difference unless you are talking legacy Ethernet from more than a decade ago.
@matthewferguson25152 жыл бұрын
Thank you for really helping me understand ethernet cable.
@techydude4 жыл бұрын
stopped watching when you called it “UNIVERSAL twisted pair”
@hongtanke4 жыл бұрын
yeah, I'm watching it through to see how bad it is.... universal made me laugh. But hey! guy's got a cert so obviously he knows more!
@jeremysmith16174 жыл бұрын
I really like how you put the emphasis on JR---rrrrrrrrrrr lol. Great vid man.
@kai74744 жыл бұрын
"With ethernet you're only using 4 wires, the other 4 don't do anything" Categorically FALSE. With 100mbit, yes, With anything above 100mbit, such as nearly All electronics now having Gigabit / 1000mbit, ALL 8 wires are important. Telling people how to make a cable and telling them that only 4 wires are used, will likely result in them getting poor performance. Many internet packages are over 100mbit nowadays, and a 4-wire Ethernet run will NOT be able to deliver above that speed. Also saw some comments about PoE - Most PoE Power specs don't "take over" wires, they lay the power on top of the data on those wires. Gigabit with passive and active PoE specs still has data on all 8 lines. The difference between Passive and Active are that Passive standards are not exactly standards. Every company rolls their own, and sometimes even within a brand there are 12, 24 and 48 volt passive options. Active is a standard such as 802.11af (13 watts), 802.11at (25 watts), 802.11bt (51 watts / 71 watts). Passive is "Always on" - as in if you plug in a device that's not expecting it, it will likely fry at least the network card of whatever you've plugged in. Active/Standard PoE is "negotiated", where tiny pulses are sent that wont damage any properly designed product, and if that product wishes to use Power, it can use those tiny pulses to send back a request for the power to be turned on to one of the available wattage limits depending on the standard.
@timezonewall4 жыл бұрын
And....a standard land line telephone only uses 2 wires (1 pair) and has for over 100 years. He said it uses 2 pairs, one pair to send voice and one to receive, that is completely false. Through sound cancellation done on each end in the telephone itself, the person does not hear themselves in the earpiece, they only hear the far end party. The video author is going too far out of his wheel house and loses a lot of credibility fairly early on in the video. Then he says he is training people for Rogers (a telecom in Canada), that's a little scary. He didn't make any mention of maintaining the correct twist in the connector which is part of the specification, nor did he talk about bend radius, or the various ratings (CM, CMR, CMP, etc). His testing involved a simple continuity check using a cheap tester, which may be okay for short residential runs, but it's certainly not for a professional commercial installation. In a pro install, every cable is "certified" at high frequency with a tool that costs over $1K and a report proving it is given to the customer. It's not that unusual to pass a simple continuity test, but fail on a true certification tester. It's clear he hasn't had any professional training in network cabling, likely just picked things up organically from others. That's fine for home DIY, but there is so much more one needs to know to for professional installs and he implies that he is a professional at this.
@kai74744 жыл бұрын
@@timezonewall Thankfully he's not referring to Rogers Communications, but a Rogers that seems to just be an electrical sub-contracting sub-contractor that pairs electricians with work.
@timezonewall4 жыл бұрын
@@kai7474 Okay, I missed that.
@bobstalnaker97064 жыл бұрын
I noticed you have 4 subscribers.....this man is giving it a shot and trying to give general info....I'm a telecom guy for 20 years and could pick him apart and he could on my electrical work. I imagine a world were we could work together and build each other up, rather than tear-down. Just saying....especially with a virus spreading nationwide, get over yourself.....in a nice way...I've been there.
@timezonewall4 жыл бұрын
@@bobstalnaker9706 When someone in a video says, "hey I'm no expert, but this is what I did" people tend to give them a lot of latitude and be more gentle in correcting mistakes. That's not the case here. The video author is holding themselves out as having expertise that they don't have, so it's not surprising to see those that really do have expertise call him out on mis-information.
@3030watergates3 жыл бұрын
Actually yes keystone Jack wiring does differ if your RJ-45 is wired B then your keystone Jack needs to be wired A also if you are running a patch panel then you have to make sure that you check which configuration they wired it A or B
@Ressy665 жыл бұрын
OMFG .... where do I start .... @04:47 WTF? no, most of the rest of the world uses "A" ,, also of note US Govt Buildings must only be cabled in "A" There are couple other things wrong with the first few minutes too, all 4 pairs ARE used for data in the gigabit ranges.. and 2 pairs for phone systems? analog requires one pair, 2 pair is for some pabx's or old phones with 2 lines though. cat 5 is no longer a standard, its been removed, but commonly used term cat "5" used now days is the meaning of cat "5e" @7:28 no ,no no ,NO. you NEVER EVER trust you have not nicked those pairs, the draw string is so when you cut the sheath, you DO pull down and snip off just below where you scored the sheath, meaning you have no possible way of using a pair that been nicked that WILL cause you problems at some point if not right away, I have failed certifications because installers have been sloppy and not followed the correct method and nicked a pair or three @18:11 I'm glad you put the cable "just inside" the jacks - many installers dont, so big plus there, but. it is very important to keep the twists as close to the punchdown point as possible.
@michaelm.69555 жыл бұрын
568b is The BICSI standard for all Telecom/data terminations. 568a is generally only used for government buildings.
@Ressy665 жыл бұрын
BICSI is not universal, applicable to the USA, "B" standard is not used in Asia, Australia, New Zealand, or any EU country that I know, except Russia
@michaelm.69555 жыл бұрын
@@Ressy66 okay sorry, I'm from the "silicon valley."
@Ressy665 жыл бұрын
oh youre forgiven then.
@MrJR864 жыл бұрын
B is used in Norway!
@bayoubees944710 ай бұрын
Great video. Having never run Cat5 cables this information helped me succeed!
@sssiamese73484 жыл бұрын
I turned off at 1:14. 10MB...
@aplasser4 жыл бұрын
Lollllll haha ditto
@jeremyfish19754 жыл бұрын
Or that CAT3 is twisted....
@richardcranium58395 жыл бұрын
a solid conductor can transfer data at unheard of speeds. the problem is there is capacitave and inductive coupling that occurs corrupting the signal. the twist is for noise rejection and capacitance and inductive decoupling and the number of twists per inch is directly related to the data rate the cabling is to be used for. nothing worse than an old cable too close to a florescent light or next to a fan motor with a bad bearing. strong enough emp will corrupt any data! using the wrong cable is like trying to push a bowling ball through a garden hose. but great video as always!