Setting Up Wires for Switches in a 3 Gang Switch Box

  Рет қаралды 98,247

Electric Pro Academy

Electric Pro Academy

Күн бұрын

Пікірлер: 41
@bryanrudel9005
@bryanrudel9005 3 жыл бұрын
Can you share the link to the next video after this one? I'll be wiring up a 3 switch box and this would be perfect
@ElectricProAcademy
@ElectricProAcademy Ай бұрын
Sorry we missed this comment 2 years ago! Will this: kzbin.info/www/bejne/rqLaZqxpic2Bodk or this: kzbin.info/www/bejne/bJXOoXugpdmigKs work for you?
@brianhooper2452
@brianhooper2452 Жыл бұрын
@electricproacademy need a follow up video to this. What’s the plan for black wires and ground? Daisy chain?
@ElectricProAcademy
@ElectricProAcademy Ай бұрын
Sorry we missed this comment! Will this: kzbin.info/www/bejne/rqLaZqxpic2Bodk or this: kzbin.info/www/bejne/bJXOoXugpdmigKs work for you?
@laurelglenn
@laurelglenn 2 жыл бұрын
Thank you, great and very clear lesson
@duaneanderson6198
@duaneanderson6198 Жыл бұрын
Looking the internet over for this exact setup...thank you
@homerepairguy1902
@homerepairguy1902 Ай бұрын
In a Ryan Reynolds way, this is a great video!!
@ziggydiaz7601
@ziggydiaz7601 3 жыл бұрын
Loving the channel, quick question, why 14 gage and not 12 gage at least in the hot feeding the box?
@raphaeljr441
@raphaeljr441 8 ай бұрын
Do u have a video for the next part connected the switch
@christopheralaniz5079
@christopheralaniz5079 2 жыл бұрын
how do you know witch one is the hot feed coming into the box ?? on a all ready installed outlet in a new home ??
@ElectricProAcademy
@ElectricProAcademy 2 жыл бұрын
By code the black conductor _should_ be black, but a more thorough test would be pulling both wires off of a device and testing them separately. The hot will have a voltage ~120, while the other should only have nominal voltage ~10-20
@simond.9457
@simond.9457 Жыл бұрын
Great video! Thanks!!!
@mikejustice1196
@mikejustice1196 Ай бұрын
Where is the pigtail for the neutral according to the 2023 NEC code?
@sassy36587
@sassy36587 Ай бұрын
This video was made in 2021.
@mikejustice1196
@mikejustice1196 Ай бұрын
@ the NEC code for the pigtail started in 2011
@anthonyesposito7
@anthonyesposito7 Ай бұрын
Why is there so much insulation inside the box?
@NathanHarrison7
@NathanHarrison7 9 ай бұрын
When do you attach the white neutral wire to the silver screw on the switch? If ever.
@ElectricProAcademy
@ElectricProAcademy 9 ай бұрын
It's generally best practice to connect ground to green screw, then neutral to silver, then hot to brass last
@joeycatropa3779
@joeycatropa3779 2 жыл бұрын
Why don’t do separate hots and grounds for each switch? It makes it easier if there is a problem .
@ElectricProAcademy
@ElectricProAcademy Ай бұрын
Couple reasons: 1. While pigtails aren't formally calculated toward box-fill, they do take up additional real space. 2. More terminations means more additional potential failure points. 3. If there is a problem, A. There is intrinsic additional information in a single hot feed setup. All devices problematic? Home run or breaker issue. Only 1 device misbehaving? Either the device or the switch leg likely need replaced. B. Flipping the breaker for those 3 devices might be an inconvenience, but it's likely easily overcome (wear a headlamp, etc.).
@keebineer
@keebineer Жыл бұрын
I have some 3-gang boxes in my house with all grounds connected with a wire nut, but there are no pigtails for grounding each of the switches. Is it ok to daisy-chain a single ground wire between all three switches, instead of using individual ground pigtails? My concern is that there is very little space left to add three individual ground pigtails. Is this ok and code-compliant? Seems like it's ok to do since a single ground is coming out of that grounding wire nut.
@ElectricProAcademy
@ElectricProAcademy Жыл бұрын
Yep, totally fine! Good check.
@keebineer
@keebineer Жыл бұрын
@@ElectricProAcademy awesome, I appreciate the prompt response!
@keebineer
@keebineer Жыл бұрын
@@ElectricProAcademy I thought I’d ask another questions while I’m at it 😀 I have a GFCI in my garage with no other outlet or switch on that circuit. I want to install a floodlight, can I source power from the GFCI load side? All GFCIs in my house are by themselves on individual CBs, I don’t know if that’s a code requirement or not (I’m in NY).
@jlewis1091
@jlewis1091 Жыл бұрын
@@keebineerthat’s where I would source it from if it were me.
@keebineer
@keebineer Жыл бұрын
@@jlewis1091that’s what I ended up doing :)
@vivaalbania1
@vivaalbania1 8 ай бұрын
you should pigtail the wires its more simple and more secure
@skdiver1
@skdiver1 6 ай бұрын
Why that 3 gang box doesn't have a support on the right to keep the box from swinging in ,some places that won't pass INSPECTION 😢😢
@mikejustice1196
@mikejustice1196 Ай бұрын
I thought I was ahead of the curve by not wearing a ring.
@ElectricProAcademy
@ElectricProAcademy Ай бұрын
😅
@matttyler390
@matttyler390 2 жыл бұрын
Just have to mention that romex going into blue boxes must be stapled within 8 inches , 12 inch rule applies when you have a 2-screw NM connector like you would use on metal boxes because they actually grab the romex correctly
@josterpi
@josterpi 2 жыл бұрын
@@ElectricProAcademy I suspect that Matt is thinking about the exception to 314.17(C), where it states that where the cable is fastened within 8 in, securing the cable to the box shall not be required. There are blue boxes that have knockouts instead of integral clamps, but the one you used here does have clamps.
@987stang
@987stang Жыл бұрын
Hello do you have an email I can send you a pic and question?
@ElectricProAcademy
@ElectricProAcademy Жыл бұрын
Hit us up on Facebook or Instagram
@ElectricProAcademy
@ElectricProAcademy Жыл бұрын
Or Hello@ElectricProAcademy.com
@surferdude642
@surferdude642 2 жыл бұрын
What's the plan for the hot wire and the ground? It looks like you will jump the ground wire from switch to switch and if so I can understand and accept that. The hot wire should be pigtailed to each switch imo. The flange on the box must be supported by using another stud. Letting it hang there unattached is unacceptable. Overall, I'm not thrilled, you can do better than this, Joel.
@davidmorrow2589
@davidmorrow2589 9 ай бұрын
Never wired any switches. Ggggrrrrr
@juniorsalas3687
@juniorsalas3687 Жыл бұрын
Horrible!!!!
@jesseestrada4290
@jesseestrada4290 2 жыл бұрын
Why only one ground pig tail when you need 3 ? AND Why not just make up the bx already if ure already touch in it, I'm not a fan in touching things twice, if I see someone wasting time like that I'll fire them because there costing money to the company in being inefficient, touch it once leave it ready for trim-out and get out...!!
@aurvaroy6670
@aurvaroy6670 Жыл бұрын
First of all, that's not a ground pigtail. In fact, he didn't do any pigtails at all, which is why he folded all the hot wires after joining that. Him or his other members will do the pigtails later when the walls are up and the switches are ready to be connected in the box. So I guess his method of bonding grounds is to use a green wire nut to leave one long wire which would then be pigtailed or connect all three switches. Second of all, this is his work, not yours. He's the CEO of his company, so the fact that you think so low of him really worries me. If you like to pigtail before trim-out then do so. But don't expect others online, especially a master electrician/CEO to follow everything you do
@collygomez219
@collygomez219 8 ай бұрын
Too much sheathing in box you only need at least quarter inch son
How To Wire a Multiple Gang Switch Box Rough In
24:23
Benjamin Sahlstrom
Рет қаралды 854 М.
진짜✅ 아님 가짜❌???
0:21
승비니 Seungbini
Рет қаралды 10 МЛН
КОНЦЕРТЫ:  2 сезон | 1 выпуск | Камызяки
46:36
ТНТ Смотри еще!
Рет қаралды 3,7 МЛН
Counter-Strike 2 - Новый кс. Cтарый я
13:10
Marmok
Рет қаралды 2,8 МЛН
Installing a 3 Gang Switch Box
10:55
Electric Pro Academy
Рет қаралды 18 М.
How NOT to Wire Light Switches in 2024 (New Rules)
15:21
Backyard Maine
Рет қаралды 1,6 МЛН
STOP Cutting Wires So Short!!! What Does Code Say?
6:37
Electrician U
Рет қаралды 126 М.
How To Wire 3 Light Switches In One Location
7:49
Any Hour Services - Electric, Plumbing, Heating & Air
Рет қаралды 68 М.
The Best 3 Way Switch Explanation Ever!
11:49
Terry “The Internet Electrician” Peterman
Рет қаралды 4,2 МЛН
진짜✅ 아님 가짜❌???
0:21
승비니 Seungbini
Рет қаралды 10 МЛН