Try SkyCiv 1. Purchase the standalone - SkyCiv Quick Design Module: skyciv.com/structural-software/quick-design/?cc=brendan 2. Access the integrated version with SkyCiv Structural 3D by signing up for an extended 30-day free trial of the Professional account: skyciv.com/brendan/
@QuickQuestionEngineering7 ай бұрын
That’s very interesting about shielding. ASCE 7 (for the US) explicitly prohibits any reduction in wind loads due to shielding unless a wind tunnel study is performed. Some of the reasonings are that 1) if the adjacent building gets demolished in the future, you wouldn’t be able to count on it anymore, and 2) reports have indicated wind regenerating or picking up speed around the corners of adjacent buildings. Just food for thought. Keep up the great work Brendan!
@BrendanHasty7 ай бұрын
This covered more exposure classification in the US. For Australia and NZ the reduction from shielding needs multiple building in the wind direction to provide reduction, so the demolition of one building wouldn't affect it. The building surrounding also needs to be taller then your structure to have significant impacts yea Vortexes off building can have detrimental effects on the wind loads. Thanks for the support
@malikdaniyel1467 ай бұрын
Great content Brendan. Living in the Caribbean we have to design for hurricane categories from cat 1 to 5 with wind speeds at 74 to 157+ mph. We recently had a cat 4 passing between barbados and Tobago with effect from the outer bands. Thanks for the video Malik from Barbados.
@mariansykora53417 ай бұрын
Topic of the video fits my PhD dissertation thesis: Experimental and numerical analysis of wind pressure coefficient. Cheers!
@_Breakdown7 ай бұрын
4:28 - - wind in business districts 4:49 - - as a building gets taller - the wind load goes up vertically 5:10 - - wind must also be calculated for 40x the height + a 500 meter radius around a building.
@kirankumarkv55287 ай бұрын
Awesome content. 🎉 Also can you please do a video about comparison about wind load calculation based on American and European standards. Wind gust speeds, Mean Recurrence Interval etc on different standards confuses the engineers some times. Thanks 😊
@psthew5 ай бұрын
I offer a correction: At 2:20 when you are talking about terrain categories, you are referring to the 2011 version of the code. The 2021 version of AS1170.2 reclassified all water surfaces as 1.0 and did away with the 1.5 category. Updated research showed the waves have less effect than previously thought. So the ocean and all bodies of water are now classified as terrain category 1
@BrendanHasty5 ай бұрын
thanks for the update and correction
@gourabsarker95527 ай бұрын
Sir do you earn 150k dollars a year in Australia now? Plz reply. Thanks a lot.
@BoZhaoengineering7 ай бұрын
Currently, CFD can be utilized to obtain wind load for complex structures.
@BrendanHasty7 ай бұрын
It can but not often used normally it is done in a wind tunnel