How to pass strong column weak beam check in ETABS Tutorial

  Рет қаралды 15,361

Engineering Learning Platform

Engineering Learning Platform

Күн бұрын

Пікірлер: 25
@EngineeringLearningPlatform
@EngineeringLearningPlatform 3 жыл бұрын
Watch, "How to pass strong column weak beam check in ETABS Tutorial"
@zahidairfan6161
@zahidairfan6161 3 жыл бұрын
strong column weak beam check was an awaited tutorial , thanks
@laythhasan518
@laythhasan518 8 ай бұрын
thanks for sharing this video , I would like to ask , is it needed to use modifier 0.25 for slab in slab beam system, I checked ACI-318 - 19 for that and its written that its necessary for flat plates and flat slab
@dilipngangom4198
@dilipngangom4198 2 жыл бұрын
Does ETABS check the shear strength of Beam-Column joint as per IS:13920-2016 cl.9 over and above Strong column-Weak beam check? How can I verify the check?
@Engrwaleed555
@Engrwaleed555 3 жыл бұрын
AOA brother. Udemy par ju course ap me upload kia hai us mai detailing ka portion cover kia hai ap ne? I mean complete working drawings ju ham banate hein submission ke leye.
@EngineeringLearningPlatform
@EngineeringLearningPlatform 3 жыл бұрын
No, it's an ETABS course primarily, but additionally design aspects are covered and you can check the topics covered on the landing page of course: www.udemy.com/course/etabs-rcc/?referralCode=4F571121E8073D773BE7
@gowthamiv4841
@gowthamiv4841 2 жыл бұрын
its nice..what about the size of 24" x 24" by increasing column will it feasible to adopt though the member size passed???
@EngineeringLearningPlatform
@EngineeringLearningPlatform 2 жыл бұрын
Sorry the question is Unclear. However if a size is passing checks then there would be no reason to increase size
@gowthamiv4841
@gowthamiv4841 2 жыл бұрын
@@EngineeringLearningPlatform 24" x 24 " size passed once 18"x18" not passed..but adopting of 24 " is feasible for residential??
@EngineeringLearningPlatform
@EngineeringLearningPlatform 2 жыл бұрын
@@gowthamiv4841 it is totally dependent on the project I cannot judge that without looking at drawings, it's an Engineer's call and judgement
@andresdavidtorrescarranza1953
@andresdavidtorrescarranza1953 2 жыл бұрын
how can i check strong column weak beam if I have a intermediate sway? as We know, Etabs just calculates strong column weak beam for special moment frames.
@EngineeringLearningPlatform
@EngineeringLearningPlatform 2 жыл бұрын
Didn't get the question
@andresdavidtorrescarranza1953
@andresdavidtorrescarranza1953 2 жыл бұрын
@@EngineeringLearningPlatform Hi, thank you for aswering me, I mean, when I have a intermediate sway and I want to check 6/5 beam/column capacity ratios OR column/beam capacity ratios I get from Etabs N/A, it happens because Etabs Just calculates these capacity ratios for special frame moments, so as I mention before, I have a intermediate sway and I want to do these Checks. How can I check 6/5 beam/column capacity ratio in an intermediate sway?. In this video you are working whit a special frame moment so you can check 6/5 beam/column capacity ratio.
@zahoorahmadnisar5841
@zahoorahmadnisar5841 3 жыл бұрын
Can you please share any technical doc that how etabs calculates it.
@EngineeringLearningPlatform
@EngineeringLearningPlatform 3 жыл бұрын
Go to Etabs help menu, click on manuals there you can see list of manuals of different codes, see for your code and the pdf manual will open
@rcbsht9644
@rcbsht9644 2 жыл бұрын
can you explain the color of column it displays as red pink and sometimes as black
@EngineeringLearningPlatform
@EngineeringLearningPlatform Жыл бұрын
Red is failure. Black is if you haven't designed it
@adrianuslahiwu1002
@adrianuslahiwu1002 2 жыл бұрын
are the wall loads include in mass source ??
@EngineeringLearningPlatform
@EngineeringLearningPlatform 2 жыл бұрын
They must have to be
@civilideas1925
@civilideas1925 2 жыл бұрын
👍🏻
@dibesshrestha796
@dibesshrestha796 3 жыл бұрын
What does N/A mean in c/b capacity ratio
@EngineeringLearningPlatform
@EngineeringLearningPlatform 3 жыл бұрын
Mostly arises when the beam is not assigned "beam property" happens by mistake, or if the joint is not properly forming at common node or even releases can cause this issue.
@4ta01_josuadmarthrietchyri7
@4ta01_josuadmarthrietchyri7 Жыл бұрын
@@EngineeringLearningPlatform How ti fixed it? please answer.
@EngineeringLearningPlatform
@EngineeringLearningPlatform Жыл бұрын
@@4ta01_josuadmarthrietchyri7 select the members, go to design and then "overwrite the frame design procedure" to correct one. If concrete so concrete or steel so steel
@zulkarnainbinmohdsalleh2024
@zulkarnainbinmohdsalleh2024 7 ай бұрын
Confused…
MODEL MASONRY STRUCTURE IN ETABS PART 1
33:53
Engineering Learning Platform
Рет қаралды 21 М.
How to calculate expansion joint in Etabs
17:53
Engineering Learning Platform
Рет қаралды 5 М.
小丑妹妹插队被妈妈教训!#小丑#路飞#家庭#搞笑
00:12
家庭搞笑日记
Рет қаралды 35 МЛН
Minecraft Creeper Family is back! #minecraft #funny #memes
00:26
Strong Column Weak Beam Design
22:49
Dr. Saleema Panda
Рет қаралды 10 М.
How To Fix O/S In Columns? ETABS
8:01
Mr EngineerO
Рет қаралды 4,3 М.
WEBINAR: How to use Meshing Tools Effectively
38:09
Computers and Structures, Inc.
Рет қаралды 28 М.
Difference Between Shell Thick, Shell Thin & Membrane
10:04
DECODE BD
Рет қаралды 27 М.
How to calculate seismic joint in Etabs
17:19
Engineering Learning Platform
Рет қаралды 2,2 М.
How to rectify beam failure in Etabs? How to make model safe in Etabs?
14:15
CIVILFIELD TRAINERS
Рет қаралды 10 М.
小丑妹妹插队被妈妈教训!#小丑#路飞#家庭#搞笑
00:12
家庭搞笑日记
Рет қаралды 35 МЛН