Watch, "How to pass strong column weak beam check in ETABS Tutorial"
@zahidairfan61613 жыл бұрын
strong column weak beam check was an awaited tutorial , thanks
@laythhasan5188 ай бұрын
thanks for sharing this video , I would like to ask , is it needed to use modifier 0.25 for slab in slab beam system, I checked ACI-318 - 19 for that and its written that its necessary for flat plates and flat slab
@dilipngangom41982 жыл бұрын
Does ETABS check the shear strength of Beam-Column joint as per IS:13920-2016 cl.9 over and above Strong column-Weak beam check? How can I verify the check?
@Engrwaleed5553 жыл бұрын
AOA brother. Udemy par ju course ap me upload kia hai us mai detailing ka portion cover kia hai ap ne? I mean complete working drawings ju ham banate hein submission ke leye.
@EngineeringLearningPlatform3 жыл бұрын
No, it's an ETABS course primarily, but additionally design aspects are covered and you can check the topics covered on the landing page of course: www.udemy.com/course/etabs-rcc/?referralCode=4F571121E8073D773BE7
@gowthamiv48412 жыл бұрын
its nice..what about the size of 24" x 24" by increasing column will it feasible to adopt though the member size passed???
@EngineeringLearningPlatform2 жыл бұрын
Sorry the question is Unclear. However if a size is passing checks then there would be no reason to increase size
@gowthamiv48412 жыл бұрын
@@EngineeringLearningPlatform 24" x 24 " size passed once 18"x18" not passed..but adopting of 24 " is feasible for residential??
@EngineeringLearningPlatform2 жыл бұрын
@@gowthamiv4841 it is totally dependent on the project I cannot judge that without looking at drawings, it's an Engineer's call and judgement
@andresdavidtorrescarranza19532 жыл бұрын
how can i check strong column weak beam if I have a intermediate sway? as We know, Etabs just calculates strong column weak beam for special moment frames.
@EngineeringLearningPlatform2 жыл бұрын
Didn't get the question
@andresdavidtorrescarranza19532 жыл бұрын
@@EngineeringLearningPlatform Hi, thank you for aswering me, I mean, when I have a intermediate sway and I want to check 6/5 beam/column capacity ratios OR column/beam capacity ratios I get from Etabs N/A, it happens because Etabs Just calculates these capacity ratios for special frame moments, so as I mention before, I have a intermediate sway and I want to do these Checks. How can I check 6/5 beam/column capacity ratio in an intermediate sway?. In this video you are working whit a special frame moment so you can check 6/5 beam/column capacity ratio.
@zahoorahmadnisar58413 жыл бұрын
Can you please share any technical doc that how etabs calculates it.
@EngineeringLearningPlatform3 жыл бұрын
Go to Etabs help menu, click on manuals there you can see list of manuals of different codes, see for your code and the pdf manual will open
@rcbsht96442 жыл бұрын
can you explain the color of column it displays as red pink and sometimes as black
@EngineeringLearningPlatform Жыл бұрын
Red is failure. Black is if you haven't designed it
@adrianuslahiwu10022 жыл бұрын
are the wall loads include in mass source ??
@EngineeringLearningPlatform2 жыл бұрын
They must have to be
@civilideas19252 жыл бұрын
👍🏻
@dibesshrestha7963 жыл бұрын
What does N/A mean in c/b capacity ratio
@EngineeringLearningPlatform3 жыл бұрын
Mostly arises when the beam is not assigned "beam property" happens by mistake, or if the joint is not properly forming at common node or even releases can cause this issue.
@4ta01_josuadmarthrietchyri7 Жыл бұрын
@@EngineeringLearningPlatform How ti fixed it? please answer.
@EngineeringLearningPlatform Жыл бұрын
@@4ta01_josuadmarthrietchyri7 select the members, go to design and then "overwrite the frame design procedure" to correct one. If concrete so concrete or steel so steel