Thank You Sir, your teaching method is just flawless. I have a question. What procedure we should follow if voltage drops by more than 5% upto the final DB ? What should we do in that case ?
@yogeshkharat203710 күн бұрын
YOU ARE GREAT SIR ♥
@DefineThenSolve6 ай бұрын
Very helpful, lots of love, if you can clear one thing please, In which percentage of voltage drop the cable size need to be extended?
@EngineerTaj6 ай бұрын
Upto final DB it should not be decreased more than 5%
@DefineThenSolve6 ай бұрын
@@EngineerTaj Thanks a lot 💛
@maazahmad16313 жыл бұрын
You explain in a very easy way. Can you please make more videos regarding load calculation. I'm working in abu dhabi and I'm interested to learn about wiring calculation, load calculation in UAE. Suppose we have 4 villas or 5 flr building, please calculate total load, MCB,MCCB sizes,single line diagram, how many MBD and SMDB required, Thank you
@EngineerTaj6 ай бұрын
I have made lots of videos check if it helps, apologies for delay, do you still need this?
@rajibpasha15173 ай бұрын
Awesome video....
@sudhirnair6867 Жыл бұрын
Dear Sir, your Explanation was good and understandable, only the thing as per your formula for ampere calculation was little confusion i.e you told it is 1.739* or is it 1732*, furthermore you didn't mentioned the maximum allowed% for Vd.
@EngineerTaj Жыл бұрын
1.73 and max 5% vd is allowed upto final DB
@muzzamilsaleem47712 жыл бұрын
Bundle of thanks sir for your kind information Dear sir now we need information about online metering system in UAE, and how to install cat-6 cable in SMDB room and how to read drawing for metering system
@EngineerTaj6 ай бұрын
Apologies for delay, do touch base still need this info?
@fazleazim4792 жыл бұрын
sir different websites has different voltage dropo formula like V Drop = 2 x Z x I x L / 1000, im confused which one to follow. i also have seen many different formula for VD
@navabjohn16619 ай бұрын
This formula also similar but multiple 2 for single phase
@muhammadrezwan23512 жыл бұрын
Assalamu Alikum ma na 2019 ma electrical engineering complete ki ha us ka bad out of Feild job kr rha hon mje kon si skill seekhni chiye electrical job hasl karne ka lye as a fresher.....
@ayztekprojects2 жыл бұрын
Autocad Electrical, PLC SCADA or industrial automation, Revit MEP
@EngineerTaj2 жыл бұрын
Autocad, Ms Excel is essential , some other skills if you want to go in automation field then PLC and scada, any thing you can learn online free of cost no need to pay anyone , You can pay for the course if they will provide you placement also.
@mdaarif7333 жыл бұрын
Thank you sir for give my question to answer.
@riadhossen5623 Жыл бұрын
Thanks , The way you explain. good
@EngineerTaj6 ай бұрын
Welcome
@shafeeqahamed7059 Жыл бұрын
👌 Excellent
@EngineerTaj6 ай бұрын
Thanks
@ashimkumarnandy113811 ай бұрын
Sir, How you have calculated the VD factor. Will you please explain ?
@mehmoodurrehman93229 ай бұрын
Subscribed and liked it too ❤
@EngineerTaj6 ай бұрын
Thanks
@zubairmahar2222 Жыл бұрын
Bhai voltag drop ni chahye kitna load ho aur os k liye hamain khud cable ka size nikalna ho wo formula chahye
@EngineerTaj Жыл бұрын
Already made that video check in playlist
@navabjohn16619 ай бұрын
Hi brother you made explain nice but dividing by 1000x N if some where used 2 run cable means we have to divide 2000
@ZiaUrRahman-lp1sz7 ай бұрын
Sir plz explain demand and diversity factor and its Applications
@EngineerTaj6 ай бұрын
It changes according to local regulations and should be kept in drawing as they instructed but not necessarily
@mdparwez40362 жыл бұрын
W=V*I, Ampere nikalne ke liye formula use krte hai... Aap ne ye koun sa formula bataya hai 1.739*kw yee kaise Please explain.......
@IbrahimGulraiz5 ай бұрын
kzbin.info/www/bejne/oWbCkpJ3lpx9pLM
@mdmanauwar9060 Жыл бұрын
Hello sar ..make one video in electrical schematic drawings ..i want to know
@wilsonmendees29112 жыл бұрын
Sir...can i get the information that ...how have i calculate Cable tray/Ladder for cables(Diff siges in one Tray)
@azizashaheen75832 ай бұрын
nice
@ELECTRICALENGINEERSUAE2 жыл бұрын
Sir , how to calculate voltage drop from three phase DB to single phase load .
@EngineerTaj2 жыл бұрын
Formula will be the same
@alexsunder91223 жыл бұрын
Thank you. Taj bhai
@SavageShorts12353 жыл бұрын
You are a gem bro
@mirzasaqib4220 Жыл бұрын
Brother need video about electrical site engineer
@hanifabaali3299 Жыл бұрын
Good sir g
@EngineerTaj6 ай бұрын
Thanks
@ZiaUrRahman-lp1sz7 ай бұрын
Sir plz explain demand and diversity factor plz
@amirezaz Жыл бұрын
Sir g single phase ka ampre kese nikale
@EngineerTaj Жыл бұрын
Ampere nikalne ka separate video hai, you can check out in playlist
@amirezaz Жыл бұрын
Video ni mil rahi sir g
@wilsonmendees29112 жыл бұрын
Thank you....
@EngineerTaj6 ай бұрын
Welcome
@shafeeqahamed7059 Жыл бұрын
Please upload cable size calculation
@naserkhan3132 жыл бұрын
Assalamualykum engineer Nice explanation Please make video on what we have to do after getting voltage drop of cable.. Means how to select cable as per voltage drop or how to compare with standard voltage drop values of cables for different applications
@ISLAMICWORLD279 ай бұрын
love you broooooo
@umermukhtar4472 Жыл бұрын
AMAZING
@EngineerTaj6 ай бұрын
Thanks
@kv8483 жыл бұрын
Fine brother
@aftabAli-iv4fu2 жыл бұрын
Thank you sir
@EngineerTaj6 ай бұрын
Welcome
@innocentsunny3962 жыл бұрын
What percentage of voltage drop is acceptable?
@EngineerTaj2 жыл бұрын
In general 5% but some special condition also exist
@lintopalayoor10112 жыл бұрын
What about derating factors
@engjamalhussain8232 жыл бұрын
I need cataloge for voltage drop plz
@EngineerTaj2 жыл бұрын
I will try
@KamalUddin-jq5lm3 жыл бұрын
👍🏻👍🏻👍🏻
@adithcheshan27482 жыл бұрын
thanks
@hafizaftab-gq9dt Жыл бұрын
❤
@anuj50847 ай бұрын
1.732 also multiply in A rating
@EngineerTaj7 ай бұрын
Can you explain
@vishnurnair63302 жыл бұрын
Difference between cw and e1w glands
@EngineerTaj2 жыл бұрын
E1w provide more protection to weather compare to cw
@Ad4282 жыл бұрын
MashaAllah
@sarikajeswal60162 жыл бұрын
Pls provide pdf voltage drop calculation sheet
@salahuddinbangash47852 жыл бұрын
Vr = (V(no-load) -V(full-load)) / v(no-load)
@mirzasaqib4220 Жыл бұрын
Y we divide 1000
@EngineerTaj Жыл бұрын
Formula
@mirzasaqib4220 Жыл бұрын
@@EngineerTaj i ask logic
@EngineerTaj Жыл бұрын
Because of kW, you can check my other video on ampere conversion from kW then you will understand
@mirzasaqib4220 Жыл бұрын
Can we use i²R for drop
@mirzasaqib4220 Жыл бұрын
In this case R is unknown
@FarahFarhan-v8y2 ай бұрын
bhai kuch nazar nhi aa raha😢😢😢
@AliHassan-r5x8x Жыл бұрын
Bhai mujy ye sheet send kr do
@electricalstudent71602 жыл бұрын
pdf file load karai
@zubairmahar2222 Жыл бұрын
Aur ap ka country coad I sath watts app number chahye
@EngineerTaj Жыл бұрын
You can email me taj@techdxb.in
@ZiaUrRahman-lp1sz7 ай бұрын
Sir plz explain demand and diversity factor and its Applications
@EngineerTaj6 ай бұрын
It is used generally to optimize the circuit breaker, transformer selection and reduce load consumption on paper