Acceptance criteria for Radiography Test Test as per ASME BPVC section VIII Div I
Пікірлер: 70
@amit84ind4 жыл бұрын
Sir, thanks for valuable knowledge. You are doing great work. While, for rounded indications, that is relevant indication not reject indication.
@saravanansubramanian69903 жыл бұрын
During explanation of rounded indications that was relevant indication of according to the thickness. That's not size of rejected indication.
@amitmishra25824 жыл бұрын
Sir please explain mandatory apendix 4 of section-8 as per given in book. As chart mention isolated, random, cluster etc should be explained by you.
@souravsharma83685 жыл бұрын
what is acceptance criteria as per uw52 asme sec 8 div 1 edition 2017
@petrosmduduzi2087 Жыл бұрын
Thanks it helped ,me now i understand it better 😎🤞
@WeldingandNDT Жыл бұрын
Thank you. Please join my channel to support my initiative. Joining link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@masudhbasha29435 жыл бұрын
Thankyou sir,please make one video about welding map
@samarjitnathmazumder42413 жыл бұрын
Sir u have explained acceptance criteria for radiographic testing as per ASME SEC Viii and IX. How to decide which criteria to follow?
@saranyadevi64683 ай бұрын
Rounted indication How to calculate please immediately uptate in sir.right maltiple calculation.
@manojkundu56984 жыл бұрын
Asme b31.3 for round indications??
@noblepayyappilly791310 ай бұрын
IQI is mandatory for RT filim interpretation
@abderrahmanebenabdallah6725 жыл бұрын
thank youuu sir
@WeldingandNDT5 жыл бұрын
Thanks. Please visit my website weldingandndt.com
@mumbaithamizhan30292 жыл бұрын
Sir, could you please explain difference between Asme sec viii div1 and Asme sex ix for radiography test.
@souravbohrays41894 жыл бұрын
what is acceptance criteria for porosity when e=0.85 ,tungsten inclusion acceptance criteria????
@WeldingandNDT4 жыл бұрын
Acceptance criteria is always determined by the applicable code of construction. It can not be generalized. Thank you. Please visit my website www.weldingandndt.com/
@jagannayakuluginni46213 жыл бұрын
Thank you
@WeldingandNDT3 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@mahammadshaik58443 жыл бұрын
Sir.. Please upload vedio acceptance criteria of ASME B31.3 piping.
@umayasuresh3 жыл бұрын
Very Nice Explaination Sir
@WeldingandNDT3 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@umayasuresh3 жыл бұрын
Yes sure sir... All your videos are very useful and help ful for us .....
@Royal_Club3 жыл бұрын
Sir please explain elongated indication rounded or liner
@pankajsinghrana6961 Жыл бұрын
Pata hoga to explain karega, book se padke yaha likh raha hai, Round relevant indication ke dimension ko hi acceptance criteria bata raha hai, achhe se pad le pahle
@amalababu916 ай бұрын
Good ✨👍✨
@vishnumurali1005 жыл бұрын
Rounded indication shown is relevant indication not maximum to accept
@ramakrishnandt47434 жыл бұрын
Yes
@Jayanusudh264 жыл бұрын
Can you explain slag elongated and ISI slag difference in brief
@WeldingandNDT4 жыл бұрын
Thanks a lot. Please visit my website www.weldingandndt.com/
@nitesh76724 жыл бұрын
Plz make video on section 1
@haribolisetti26422 жыл бұрын
Sir, You have given two times for acceptance criteria of rounded indication which one is needed to use in which condition
@WeldingandNDT Жыл бұрын
Acceptance criteria is explained in this article: www.weldingandndt.com/acceptance-criteria-for-weld-defects/
@parsulimbu8514 Жыл бұрын
What is 6L
@mohammedal-dubai9442 Жыл бұрын
Please sir acceptance criteria for tank API 650
@narasingk66303 жыл бұрын
B31.3 radiography acceptance criteria also make one video plz same as like that
@praveenkumarmishra97315 жыл бұрын
Sir, Kisi bhi 2material ko jab ham welding karate hai to usko welding karane me jitni electrode lagati hai usaka calculation karne ka tarika kya hai. Kripya batane ki kripa kare. Aap ka channel bahut hi achha hai ha pcbc ke liye. Thanks
@bhaveshmali25744 жыл бұрын
Per feet of weld length and thikness of weld portion kitna hai us par depend krta h
@samdanishaik75705 жыл бұрын
Sir please make a video on B31.1,B31.3,B31.4,B31.8and api1104
@smmomin683 жыл бұрын
Sir need API 650 acceptance criteria
@roubalarbi64454 жыл бұрын
please sir if we work in bliler project ; we take acceptance criteria from ASME I OR ASME 1 lead us to ASME VIII. THANK YOU
@WeldingandNDT4 жыл бұрын
Thanks a lot. Please visit my website www.weldingandndt.com/
@uthmaniyah15564 жыл бұрын
he only said Thanks a lot :)
@uthmaniyah15564 жыл бұрын
you meant Boiler ??
@i.satish10262 жыл бұрын
Sir good evening. Can you explain About B31. 3 ,B31.1, Film interpretation latest edition
@WeldingandNDT2 жыл бұрын
Yes
@hammadalihamdan27314 жыл бұрын
Sar can you make a conprehansive video on aceptance criteria of DT please
@WeldingandNDT4 жыл бұрын
kzbin.info/www/bejne/Z5XPk4SqmctorbM
@hammadalihamdan27314 жыл бұрын
Welding and NDT sar ya men full dakh chuka hn destructive test ka bare men aceptence criteria par videoo plz
@prakashduraisamy3452 жыл бұрын
I have a doubt sir., We have separate sections for NDT ie) ASME section v for non destructive testing., Then why should we need to refer ASME sec viii div i?., I mean how we come to the conclusion that we have to refer sec viii rather than sec v.,
@WeldingandNDT2 жыл бұрын
Sec V is only for NDT and it gives a general guideline for NDT (not acceptance criteria). However, Sec VIII is exclusively for pressure vessel and it contains everything pertaining to pressure vessel including the acceptance and rejection.
@prakashduraisamy3452 жыл бұрын
Somebody told cswip 3.1 welding inspector pattern will change from april. Is it true?
@smmomin75892 жыл бұрын
Sir Please upload API- 650 Acceptance criteria
@Sreedeshputhussery4 жыл бұрын
Pls make a video about RTFI
@WeldingandNDT4 жыл бұрын
Sure. Thank you. Please visit my website for notes, videos and other important informations www.weldingandndt.com/
@KannanKannan-yt9el2 жыл бұрын
நல்லது
@pabitrakapal80214 жыл бұрын
Sir need acceptance criteriab 31.3
@WeldingandNDT4 жыл бұрын
Sure. Thank you. Please visit my website for notes, videos and other important informations www.weldingandndt.com/
@gampashivakumar5 жыл бұрын
Deposit weld material You wrote T, actually it is t. ' T ' we use as plate/pipe thinkness ' t ' we use as weld deposit thinkness. If anything wrong, please educate me. Thank you.
@kadouriaziz92835 жыл бұрын
n'existe pas la même explication en français merci
@mntpictures59962 жыл бұрын
👍🙏👍👍👍👍
@WeldingandNDT2 жыл бұрын
Thank you. Please join my channel to watch all the videos. Joining Link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@dipankarbarik64232 жыл бұрын
your information about rejection of rounded indication is not correct you tell about non relevant indication we have to check only relevant indication by the way nice work
@sarathk.s21688 ай бұрын
I think the explanation for the rounded indication is wrong.
@WeldingandNDT8 ай бұрын
Why do you think like that. Can you elaborate
@sarathk.s21688 ай бұрын
As per ASME BPVC SEC VIII DIV 1 MANDATORY APPENDIX 4 (4-3). The indication which is more the (t/10) for t less than 3mm, 0.39mm for t between 3mm to 6mm, 0.79mm for t between 6mm to 50mm and 1.58mm for t more than 50mm will be considered as a relevant indication. Below to this dimension will not be considered as a relevant indication. The acceptance criteria for a relevant indication is (t/4) for a random indication and (t/3) for an isolated indication.