How is possible to measure rotating field by measuring between phase and neutral? Between two phases indicator for rotating field is not active but usually it should be.
@terrygoyan5 жыл бұрын
Nice clear video. Does the T110 probe have a low impedance setting for finding ghost voltages?
@stupot_644 жыл бұрын
Pressing the round buttons on the main unit and probe together reduces the impedance from 200KΩ to 7KΩ.
@jobpatyahoo9 ай бұрын
is there a voltage phase tester that tells you also what phase is it like Ph-A, Ph-B, or Ph-C?
@chrismcnally90796 жыл бұрын
Can you explain the one hand rule
@pgreenx11 ай бұрын
Why get this vs Fluke T+ pro?
@micksreviews8 жыл бұрын
Why is it that every time I see someone reviewing some multi-meter or scope of sorts they have 100 scopes/meters in the background?
@EvioneElectronics7 жыл бұрын
Unfortunately that is an operational workbench. At the time it was the only place I could do the review. We have grown a lot since then and I now use a small office space for my videos.
@SuperKiller3746 жыл бұрын
Can you provide the link and name for the gloves you are wearing. Thanks
@DJChipsandGarlic2 жыл бұрын
Do you need a proving unit with this or does it have a test built in?
@dennisfabian25707 ай бұрын
These Flukes are very safe, everyone in the trade can confirm.. still using a separate proving unit is the law in most countries
@Xxxcappie234 жыл бұрын
Great video, please make more ! Are those gloves insulated? Where can I get those and what brand are they ?
@babbarhussain293 жыл бұрын
They are general use gloves and cost £1.40 at screwfix
@daliborzvak39732 жыл бұрын
For love of Jesus Christ! If you aren't educated and experienced electrician with high voltage allowance!! DON'T YOU DARE TO EVEN THING OF TOUCHING ANYTHING INSIDE THE ENCLOSURE!!!
@Xxxcappie232 жыл бұрын
@@daliborzvak3973 It's hard to take a comment on "being educated" seriously when you don't even know how to spell the word "think "properly.
@daliborzvak39732 жыл бұрын
@@Xxxcappie23 wow! Bull's eye!! I'm destroyed!!! Disabled from combat!!! For fuck's sake! Have you ever heard of automatic words finishing? Or how's that evil function named... I give a size of earth fuck of what you say because the point is as far from you as even Hawking can't imagine!
@HanaBasara Жыл бұрын
This is better than t90?
@Mark-ij2nh5 жыл бұрын
I still prefer meters that give me the accurate readouts as continuity tests are vital but remember guys continuity of each circuits are done with power off
@jesusb53857 жыл бұрын
Are those gloves electrician insulated gloves or can we use any gloves?
@EvioneElectronics7 жыл бұрын
The ones I used are semi insulated. They just guard against accidental contact and such. I suggest proper insulated gloves and an inspection of your leads and meter before testing any high energy circuits.
@jesusb53857 жыл бұрын
Thank you for the quick response. Great video.
@arne92199 жыл бұрын
Good Video! In Germany it is mandatory for professionals to check with such devices if the circuit is disconnected and save.
@EvioneElectronics9 жыл бұрын
+Arne Schwaab Its always a good idea to check and switch off before working on any mains power circuits.
@arne92199 жыл бұрын
+Evione Electronics No - I mean that it is simply not allowed and common to use a Multimeter to check power circuits as Professional Electrician (commercially) .
@arne92199 жыл бұрын
+Arne Schwaab It is described in the Standard "Din VDE 0680"
@johnystrange6657 жыл бұрын
Arne Schwaab I think you’ll find it’s mandatory in this country also.
@handle11964 жыл бұрын
Are them in sulated gloves or for a certain reason?
@foxconNI7 жыл бұрын
What is the name of the multi meter that you where using.
@EvioneElectronics7 жыл бұрын
Had to watch the video to check. :-) It is a Brymen TBM800 series.
@yosefherrera7216 жыл бұрын
it's a wiggy
@STRATOS13PAO9 жыл бұрын
what is the left rotation or the right one? i have the meter and those lights dont light up for my mains voltage
@FoodOnCrack8 жыл бұрын
+Stratos Vasilas make sure its ac and it displays 230/120v while being connected to both neutral and phase. If it then does not work contact fluke or the retailer.
@koffibanan30998 жыл бұрын
Rotation only applies to three phase power. To determine phase rotation, you press the probes at two different phases and by holding the plastic body you provide a capacitive coupling to ground. That's how the meter is able to determine the phase sequence without hooking up three wires as the traditional little rotational testers do. When he was measuring from phase to ground the 'L' did light up, but that has no significance, you need to measure phase to phase. Same deal when he was measuring the socket outlet.
@STRATOS13PAO8 жыл бұрын
thanks for the answer, its been a year and i still didn't knew what those lights were about. :)
@AfricanSouthernCross8 жыл бұрын
What is meant by a circuit having continuity ? Thanks.
@duckman56427 жыл бұрын
Mark Shaw, connection like a circle.
@AfricanSouthernCross7 жыл бұрын
Duck Man Thank you duckman, I presume that the "circle" can have continuity without needing a current to pass through ? Thank you for you answer.
@jothain5 жыл бұрын
@@AfricanSouthernCross exactly. Basically you can touch ie. single detached wire and see if has continuity etc. Tester will show and beep rapidly if has. Obviously useful in ie. 24vdc circuit when checking for ground points etc.
@david72384 жыл бұрын
You do not need to use both probe. Just read one will indicate live wire
@MarcelofabianIanni Жыл бұрын
Lastima , no se ingles
@helalchowdhruy46814 жыл бұрын
Inet one how Mass
@ВячеславИванов-и3ш3 жыл бұрын
Не работает
@Whigu7 жыл бұрын
Next time turn off that beep when doing videos like this. Otherwise great video :-)