Dear Sir, You may not know how this video solved my big problem and made my life easy....I have never ever seen such complete and clear video even from the developers of Etabs and SAP2000 software. ..Sir, Please make such comprehensive videos on ''Time History Analysis'' and ''Pushover Analysis''...Waiting to hear from you soon....Thank you so much for the great work.....
@civilknowhowtutorials71008 жыл бұрын
+Nasratullah Amarkhail yeah ...sure..
@PoojanMistry4 жыл бұрын
Why you don't use IS code? Pls use is codes
@civilknowhowtutorials71008 жыл бұрын
Kindly note that,those want to apply response spectrum analysis according to Indian code,please use scale factor as I.g/2R instead of I.g/R.
@beenay188 жыл бұрын
what value should I use for "I" and "R" according to Indian Standard? only "I" I know in Indian Standard is "Importance Factor". Is Occupancy Factor same as Importance Factor? Should I use value of I=1 for residential building? If not what will be the value of I for Indian Standard? And Only "R" I know in Indian Standard is "Response Reduction Factor" which is R=5 for special moment frame. Is "Response Reduction Factor" same as "Response Modification Factor"? If not what value should I use for "R" for Indian Standard? I used same value of scale factor as yours in my model ie 1225.83. And got Fx of RSmax= 124% of "Fx of EQx" and Fy of RSmax=114% of "Fy 0f EQy" " would I be designing the structure stronger than necessary if "Fx of RSmax" or "Fy of RSmax" exceeds 85% of "Fx of EQx" or "Fy 0f EQy" respectively? Also my sumUX, sumUY, sumRX, sumRY and sumRZ value exceed 0.9 in mode 7. So, should I reduce the number of modes to 7 or assigning any number of modes greater than 7 is ok? All of my sumUZ value is zero but RZ value is not. Is it ok if all my sumUz values are 0? should all sumRZ values also exceed 90%?
@sandipchhetri66238 жыл бұрын
I=1 and R=5 will do for residential building. The default no. of modes is 12, and if 90% of the building mass gets excited within 12 modes, then you don't have to change anything. Uz is basically displacement in z-direction, and earthquake force being applied in lateral directions only, we are bound to get Uz zero. Yes, sumRZ should be > 90%.
@afzalandthedreams6 жыл бұрын
Dear Sir could you send me the above etabs model to my mail
@MdAhmed-vg3dn5 жыл бұрын
can u please provide reason why we use (i. g/2R)? instead of (i. g/R)
@afzalandthedreams5 жыл бұрын
@@MdAhmed-vg3dn Design base shear by dynamic methods shall not be less than same calculated by equivalent static method hence result forces must be augmented by a factor according to code IS 1893-16 7.7.3. As far my knowledge there is no such similar clause in international codes. above increments operation is only required for forces, not deflections and drifts according to code, it is a question of rationality rather than the benefit. Initial Scale factor IG/2R is nothing do with the code, it is part of the formulation. if spectra acceleration is normalised by g (unitless) we should use IG/2R. if you happen to work with field spectra with acceleration where it is not normalised ( units are in m2/s) then use I/2R.
@thedhungels4 жыл бұрын
BEST OF THE BEST EXPLANATION. THANKYOU 🖐🖐🖐
@md.mizanurrahaman97394 жыл бұрын
Thanks a lot,Really very clearing tutorials for spectrum analysis.Sir Plz make such comprehensive videos on ''Time History Analysis'' and ''Pushover Analysis''.I am waiting for your response.
@bestvideos88445 жыл бұрын
Best explanation i have ever found.
@faizurrehman25236 жыл бұрын
Thats fantastic and career shaping video. Need more like this.
@m3sman1218 жыл бұрын
Nice and clean video small and accurate illustration thank u very much keep going
@civilknowhowtutorials71008 жыл бұрын
+Muhanned Othman Glad to hear that...thank you..:-)
@madhusinha24274 жыл бұрын
How to you calculate long-period transition period?
@evanah-taningauchun94364 жыл бұрын
I love your work my brother... beautiful
@pushkardeshpande31723 жыл бұрын
How to put response spectrum in Load combination?
@hypnose658 жыл бұрын
Why Cd (Deflection Amplification) factor is not used at 8:53 time?? Help me please
@aymansaeed33247 жыл бұрын
how can i find 0.2 Sec spectral Accel. Ss ?? 1 Sec spectral Accel. S1 ?? and long period Transition period ?? For the Response spectrum and the static Ex.
@frozanbarakzai11368 жыл бұрын
Thanks a million for your useful videos and content, please do keep it up!
@civilknowhowtutorials71008 жыл бұрын
+Farzad Hakimi thank you....yeah sure..:-)
@ujwalms43082 жыл бұрын
how was the calculation done for Ss and S1 values
@CEADACADEMYcivilengineering5 жыл бұрын
How can analysis the RS by using 1893:2016 and push over analysis
@santoshnarayan36034 жыл бұрын
Should we design the building for response spectrum analysis results?
@mittalrit7 жыл бұрын
Hi, Can you please tell in case we have a Importance factor more than 1, what happns or what shall be changed in static definition of the Earthquake, because, otherwise we get a difference in base shear values after application of scailing.
@nguyenthinh23015 жыл бұрын
Thank you so much for the great work! This video is very usefull.
@ajayramani93834 жыл бұрын
How to see shear force distribution in specific storey
@ayadjasim99115 жыл бұрын
Great very easy and power video
@ratankumarbiswas3362 жыл бұрын
Sir, it is a nice lecture.It help us very much as well as students. It will be more helpful to me if you kindly mention the name of good books for dynamic analysis. Thanks. Thi
@suliman90585 жыл бұрын
If i am not permitted to use static analysis should i use ig/r scale factor or not please
@syedzakir0914 жыл бұрын
How to select the type of seismic design method i.e static or dynamic for an RCC building ?
@ezzatullahtemury6 жыл бұрын
Thank you for your nice and useful videos! If we have three different structures. the plan is one but the structure is different. 1) the structure is made of columns and beams. 2) the same add a few shear walls. 3) no columns and beams only shear walls. if possible to do dynamic analysis for all of them and compare the result. would be nice of you.
@6arash97 жыл бұрын
please tell me why you didnot make acombination between the horizental forces?
@beenay186 жыл бұрын
should scale factor in x and y direction be same? can i scale them by different amount so that both of them produce 85 percent of static base shear.
@hakimuddinshamsi56635 жыл бұрын
how do we assessthe .2 sec and 1 sec. response specterum.
@adirajasimamora97206 жыл бұрын
Dear sir Does the scale factor have to be the same for x and y direction after re-scaling?
@sayeedhussaini88066 жыл бұрын
Nicely explained.....best ..sir
@ankurkumarsrivastava41255 жыл бұрын
Plese explain the modal participating mass ratio table
@aamirsheikh97896 жыл бұрын
Sir can you please upload a vedio how to to modelling of a mass tuned damper in a building
@luismendietaelena93324 жыл бұрын
Thank you very much for this!!! My question: So after re scaling, we get a 2753.25 value, wich is introduced as the new scale factor, on the load case RS. Therefore, now our new R (response modification factor) gets to be 9806.65/2753.25=3.56. (and before it was R=8!). Is there any section of the code which allows this change? or is this justified by saying that we achieved the 85% of the base shear?. Finally, just reminding the audience, that the displacements values now will have to be multiplied by 3.56. Thank you, Sir!
@hassanbasil13505 жыл бұрын
in defining RS case y u take U1 & U2 instead of U1 & U3 ?!
@nasratullahamarkhail32178 жыл бұрын
ASCE 7-05, in order to consider the live load for effective seismic weight calculation says ''In areas used for STORAGE, a minimum of 25 percent of the floor live load is considered''. Do we have to consider this 25% of live load in mass source for office or residential buildings as well or only for areas used for STORAGE?
@civilknowhowtutorials71008 жыл бұрын
+Nasratullah Amarkhail it depends on the type of buildings n the live loads applied...it is better to take 25 %
@beenay186 жыл бұрын
what do "Sum UX" and "Sum RX" in "modal mass participation ratio" table mean?
@NTC6 жыл бұрын
could you please provide the geometry layout of this building ?
@nupurdas54135 жыл бұрын
What as per is code and please tell the clause and code
@carlosgarciafluxa35386 жыл бұрын
Thanks for the tutorial. A question please. If I must find the forces in each story for do the diagram of the sum modals diagram. Where I should check? Thanks.
@maunikmevada91155 жыл бұрын
What is the difference between given time period in load pattern and getting time period after analysis ???
@danielbrhane65377 жыл бұрын
Sr. I am using G+10 model which one is more appropriate to analysis static or dynamic analysis ?
@nemalavenkatesh5 жыл бұрын
may i know the difference between civilknowhow and fieldready
@hassanhumayoun27977 жыл бұрын
what are these factors ? R,Omega,Cd and I . and where can i find out them and how can i find there value? are the predefined in the code or they depend on the area in which the building is located?
@aimuthiacitrautami45146 жыл бұрын
Hello, I'd try to answer this. Usually, we can find these factors on you country's earthquake codes. These factors are based on typical of structure we design to use
@growstock79447 жыл бұрын
can you please provide pushover analysis of RC building in etabs by capacity spectrum method with IS
@kaushik54395 жыл бұрын
Sir, Can a response spectrum data created in MATLAB or excel sheet be inserted into etabs?
@abhishekshelke45647 жыл бұрын
Nicely explained sir thank you
@arasadamanjaripatnaik58716 жыл бұрын
Sir I have analysed a model for response spectrum I have created load cases for response spectrum but while analyzing it is being displayed that loads could not start please give a solution to this problem
@patilkirankumar11404 жыл бұрын
how to take X value
@sankhadka4506 жыл бұрын
load assign and load combination are of same as that of static analysis ?
@manumoudgil96077 жыл бұрын
Hello ! Can you please tell me that the results obtained from ETABS analysis( Base shear, Displacements, Drifts) are already amplified or they have to be multiplied with the force modification factors (R in ASCE or Rd-Ro in NBCC)?
@rafikhan65356 жыл бұрын
thank you for wonderful explanation, I have two queries, first is whether I have to run model in set cases only for Response spectrum only?? second is that about how much Response modification factor R value under ubc7 for apartment
@jeffputra74077 жыл бұрын
How to show Tx and Ty in table??
@Arsuvalzz5 жыл бұрын
Please how do we design columns and shear walls next to the analysis? And it was a very useful tutorial... God bless you
@akshaydhumal73804 жыл бұрын
Thanks bro 🙏
@prabh6627 жыл бұрын
Sir, Kindly tell me if the RS analysis has to be done before defining load combination + envelop And does load combination effects the RS analysis ?? Please Reply ASAP!
@Arulmozhivarma7 жыл бұрын
A BIG thanks to you :)
@raktimbarua69735 жыл бұрын
First of all it was a fascinating tutorial. I would like to know when I am going to design for sections do I need to create additional load combinations incorporating Response Spectrum load case? Also this is new for me but based on your experience does response spectrum analysis give better results than static one in high rise buildings or does it make worse (based on it's purpose)?
@nasratullahamarkhail32178 жыл бұрын
Sir, in the video, for re-scaling, why the same value is used for X and Y directions? while the RS base shear is different for both directions, hence we get different scale factors.
@civilknowhowtutorials71008 жыл бұрын
+Nasratullah Amarkhail different scale factors are used ....pls do check the video
@nasratullahamarkhail32178 жыл бұрын
I checked it, 2753.25 (which is calculated considering the X-direction RS base shear) has been used for both X and Y directions...
@civilknowhowtutorials71008 жыл бұрын
+Nasratullah Amarkhail scaling up the min base shear value to 85 %...base shear in other gets increased propotionately
@beenay186 жыл бұрын
@@civilknowhowtutorials7100 can't we put different scale factors in U1 and U2 so that we get 85 percent of static base shear in both x and y direction.
@nikkorianto27006 жыл бұрын
is the I.g/R written in code?
@nagakishore92237 жыл бұрын
sir why did U didn't given the wind load
@hailaykidanu73017 жыл бұрын
sir, why you tries for vertical response spectrum
@beenay188 жыл бұрын
Please make a video tutorial on seismic design of soft story building by modelling the wall as struts and performing dynamic analysis.
@civilknowhowtutorials71008 жыл бұрын
+beenay18 will try if tym allows
@shivasharana75545 жыл бұрын
sir how to find out base shear
@sabith5096 жыл бұрын
May i kno what is the load combination for RS Max. Thank You
@faizahmed44734 жыл бұрын
1.2
@maunikmevada91156 жыл бұрын
Sir why scale factor required in rsa??
@herome35438 жыл бұрын
late but thank you for this tutorial.sir, according to Is code we will be using the scale factor of I.g/2R as mentioned in your comment, my question is what will be the re scaling factor according to IS code will it be Ig/2R 0.85 *static base shear/RS spectrum base shear ? your reply will be very much helpful.
@beenay188 жыл бұрын
If I am using Indian Standard, is "I" importance factor? ie I=1 for residential building? Is R response reduction factor? ie R=5 for special moment frame?
@beenay188 жыл бұрын
Is it supposed to work like this for Indian standard: So you put the scale factor as I.g/(2r) at first. And then you run analysis. And then check " (Fx of RSmax)/(Fx of EQx)" and " (Fy of RSmax)/(Fy of EQy)" if one or both of the ratios is less than 0.85 re-enter scale factor as (Ig/2R *0.85 *static base shear/RS base shear) And then run analysis. Then "static base shear/RS base shear" value will be equal to 0.85 for one among fx and fy and that value will be equal to or greater than 0.85 for another among fx and fy. at first i got I.g/(2R)=9806.65/(2*5)=980.665 I entered the value in scale factor and ran analysis. Then I rescaled the scale factor according to above procedure. but I didn't got "static base shear/RS base shear" value equal to 0.85 for one and more than 0.85 for another. both "static base shear/RS spectrum base shear" value were lower than 0.85 for both fx and fy in my case. Does it mean that above procedure does't work for Indian Standard.
@civilknowhowtutorials71008 жыл бұрын
+hero me according to Indian code scale it to total base shesr
@civilknowhowtutorials71008 жыл бұрын
+beenay18 yes
@sariaosman42678 жыл бұрын
many thanks sir ... why the vertical component of earthquake in buildings is not considered
@civilknowhowtutorials71008 жыл бұрын
+Saria Osman bcoz the vertical excitation is negligible n the major effect is due to horizontal ground acceleration..
@dhirajkalita75054 жыл бұрын
Helo sir My Ex is coming 2366.095 and RS =2387.331 at scale factor 40only .units is FPS system .is this value ok or i made any mistake? pls help
@PraveenKumar-iz2rx7 жыл бұрын
Sir, could you please teach us about p-delta analysis ??? in etabs
@keyurtailor89188 жыл бұрын
what is the significance of Scale Factor?? What does it indicate?? We are modifying Scale factor, if it is not in limit, what are we exactly doing to structure??What is the limiting ratio of Earthquake Base shear to Response Spectrum Base shear according Indian IS 1893 code???
@civilknowhowtutorials71008 жыл бұрын
+Keyur Tailor The significance of scale factor is to ensure accurate distribution of earthquake forces throughout the building frame members...
@civilknowhowtutorials71008 жыл бұрын
+Keyur Tailor Refer IS 1893 7.8.2 for scaling..
@civilknowhowtutorials71008 жыл бұрын
+Keyur Tailor Use scaling factor as Ig/2R for scaling with Indian code
@keyurtailor89188 жыл бұрын
thank you for your reply. Can you please tell me the unit of gravitational acceleration you have defined in your video tutorial???
@civilknowhowtutorials71008 жыл бұрын
+Keyur Tailor mm/s2
@nasratullahamarkhail32178 жыл бұрын
Is the formula for computing the scale factor ''Ig/R'' taken from ASCE 7-05?
@civilknowhowtutorials71008 жыл бұрын
+Nasratullah Amarkhail it is based on asce asce seismic response coefficient formula...check the csi forum
@poojah40374 жыл бұрын
I think it will be more helpful if you are explained the behaviour of graph obtained after analysing... Which includes what is crt and can be adopted
@bhupeshpant19357 жыл бұрын
Sir how to done response spectrum analysis as per Indian standard
@markanthonygumamela10148 жыл бұрын
hello, do you have a video regarding non-linear static analysis?
@civilknowhowtutorials71008 жыл бұрын
+Mark Anthony Gumamela don't hav one nw...but wil upload soon
@markanthonygumamela10148 жыл бұрын
thank you and I am hoping that you can upload a sample
@beenay188 жыл бұрын
Is non linear static analysis in etabs also called push over analysis? Is non linear analysis is a form of dynamic analysis like Response spectrum and time history analysis?
@asimjunaidsherwani-2 жыл бұрын
Dear sir, can you please tell me how can we check our foundation size with the help of this data mean to how can i calculate my footing size by using my etabs model please help me regarding this. and this was really a very helpful video
@prabhuram146 жыл бұрын
Sir please make a video for same response spectrum analysis based on Indian code.
@maspicard8 жыл бұрын
Thanks a lot Sir.
@yogeshbang6 жыл бұрын
can u pls explain modal mass participation table in all details..till last col. of Sum of Rz, with there min. & max. values required for being safe Structure. Pls explain tortional modes & min. max. values of it, how to remove it. pls upload video for same.
@Omid_Rayan8 жыл бұрын
Dear Sir Please upload some videos for shear wall and its optimization. I am concerned about its size and location in the structure.
@civilknowhowtutorials71008 жыл бұрын
+Hamid Nikzad provide 20 mm thick wall...around the lift area..that's it's usual location
@Omid_Rayan8 жыл бұрын
Civilknowhow Tutorials Thank you so much for your reply Currently I am doing research on RC frame-shear wall system optimization so I was wondering if you could upload some videos related to shear wall optimization by etabs. I am confused with how to decide the length of the shear wall based on ACI code. thank you so much
@afzalandthedreams6 жыл бұрын
@@Omid_RayanAsalamualaikum Mr. Hamid, currently i am pursuing btech could you send me dynamic analysis highrise shearwall building etabs model to my mail so that i could do learn for my project
@mohammedkhajasalahuddin98738 жыл бұрын
how to determine the number of modes for a high rise structure and how to determine number of degrees of freedom for each mode
@civilknowhowtutorials71008 жыл бұрын
+mohammed khaja salahuddin set your model to high number of modes..for eg more than 200...n analyse...analysis wil take quite a tym n while analysis click on show analysis option in the footer....then u wil b able to see no of modes n joints at the beginning of calculation...degrees if freedom will always 2 for spring supports
@mohammedkhajasalahuddin98738 жыл бұрын
OK thank u if I get any queries I will ask u for that can u plz give your email id
@nasratullahamarkhail32178 жыл бұрын
Dear Sir, In my case, I got base shear from RSA more than the linear static base shear....Is it okay or there is something wrong? because normally we expect base shear from RSA to be less than the linear static base shear...Thank you.
@civilknowhowtutorials71008 жыл бұрын
+Nasratullah Amarkhail what's the percentage in in RSA base shear wet to static base shear??
@civilknowhowtutorials71008 жыл бұрын
+Nasratullah Amarkhail what's the percentage in in RSA base shear wet to static base shear??
@nasratullahamarkhail32178 жыл бұрын
I got the point....at first, I didn't divide the scale factor by R. ie. g=386.4 in/s2 was not divided by R=8, where I=1. Now its okay. I got the right RS base shear and scaled it up to get minimum 75% of the Static Base Shear.
@mohammedkhajasalahuddin98738 жыл бұрын
sir I have done time history analysis I have defined the functions and load cases of time history analysis but after the analysis I am getting the time history analysis results as zeros what to do to get the results plz guide me plz help
@civilknowhowtutorials71008 жыл бұрын
+mohammed khaja salahuddin All the results zero lyk moment shear n displacement??
@mohammedkhajasalahuddin98738 жыл бұрын
+Civilknowhow Tutorials yes sir displacement,moments,n shears are zeros what's the problem sir can u plz solve my issue
@saqadiry53188 жыл бұрын
Thank you sir, it is really useful tutorial. it cleared lots of doubts i had regardingly but dont know how to find the number of joints for a concerned project?, as you mentioned: "This project comprises 2833 joints".
@civilknowhowtutorials71008 жыл бұрын
+Sa Qadiry it's from the analysis file..
@sarannaeemn5906 жыл бұрын
Can u upload the cad file please ??
@frsaj73967 жыл бұрын
ples. upload single footing design by safe
@ashmitakoirala34237 жыл бұрын
thanku so much
@spoorthythummala4376 жыл бұрын
please do give response spetrum analysis as per is code ,sir
@biniyambirhanu71686 жыл бұрын
WOW NICE PRECENTAION
@gainisagar67735 жыл бұрын
Sir please upload some videos on progressive collapse analysis ...pls make a video on interpretation of results of response spectrum analysis
@born2die6885 жыл бұрын
Hai sagar
@born2die6885 жыл бұрын
R u doing project on progressive collapse analysis
@born2die6885 жыл бұрын
Can I have your contact number plz
@born2die6885 жыл бұрын
I can help you
@nasratullahamarkhail32178 жыл бұрын
Sir, in case of tall irregular buildings, the moments and shears for design, should they be based on RSA analysis or static linear (ELF) analysis?
@civilknowhowtutorials71008 жыл бұрын
+Nasratullah Amarkhail RSA analysis is btr
@EngineeringLearningPlatform6 жыл бұрын
Nice
@dobocalculus8 жыл бұрын
thanks !
@serhangenc5 жыл бұрын
8:42 and 14:45 have been reserved
@mimikhaingsoe1608 жыл бұрын
Sir, Where can i find the scale factor = Ig/R in ASCE code? could you please tell me which chapter of ASCE mention this scale factor? Thanks Sir
@civilknowhowtutorials71008 жыл бұрын
+Mi Mi Khine Soe it's based on seismic coeff calc in asce ...but no direct formula is provided..check the csi forum for the formula
@VinayAKania4 жыл бұрын
Dear Sir, Sincere request to send me e mail id for solving my confusion about RS ANALYSIS IN ETABS VK
@beenay186 жыл бұрын
should scale factor in x and y direction be same? can i scale them by different amount so that both of them produce 85 percent of static base shear.
@sudeepthisuresh19285 жыл бұрын
Sir how to get the response spectrum curve on etabs