Explain principle of smart distribution panel with energy monitoring

  Рет қаралды 5,178

KinCony IoT

KinCony IoT

Күн бұрын

#homeassistant #smarthome #smartcontroller #tuya #esp32project #diyprojects
Home Automation Distribution Panel Energy Monitor| IOT Project 2024!:
• Build Own Smart Panel ...
Home Automation 8CH Raspberry Pi Distribution Board DIY | Smart IOT Project 2024 video tour:
• Home Automation 8CH Ra...
16CH Raspberry Pi Distribution Board DIY Video:
• Home Automation Raspbe...
32CH Distribution Board DIY Video:
• Home Automation 32CH D...
8CH smart distribution panel diagram download:
www.kincony.co...
visit for more:
KinCony's website: www.kincony.com
Online Store: shop.kincony.com
Facebook: / kincony.smarthome
Twitter: / kincony

Пікірлер: 38
@arbazaa7295
@arbazaa7295 2 ай бұрын
Best explanation 👏🏻!! Upload daily video sir I'm waiting for your new video's 😊
@KinCony
@KinCony 2 ай бұрын
thanks.
@Innovation_king
@Innovation_king 3 ай бұрын
The best company I ever seen in wired automation...pls make Tuya + Home assistant devices...also pls introduce a solution like KNX DALI system..
@KinCony
@KinCony 3 ай бұрын
yes, in furture we will consider about Dali.
@yedukondalumidde1900
@yedukondalumidde1900 3 ай бұрын
Your work explanation very very great🎉🎉🎉
@KinCony
@KinCony 3 ай бұрын
thanks
@ruimarinho
@ruimarinho 3 ай бұрын
Thank you! Amazing work! Here the contactor is after the breaker but in previous videos it’s different - they are the other way around. Can you explain which system works better in each scenario?
@KinCony
@KinCony 3 ай бұрын
this one is better.MCB before contactor.
@ibryxx
@ibryxx 3 ай бұрын
i noticed that too.. my setup is breakers after contactors. 😅 tho it works great with H32B pro
@Dylan_Lanckman
@Dylan_Lanckman Ай бұрын
Great product presentation, again. However, I notice 32 relay channels with contactors tend to become quite noisy. Any sollutions for that in the future? Are these relay boards also planned with a zigbee antenna or do you already have these?
@KinCony
@KinCony Ай бұрын
if use SSR without any noise. do you want zigbee relay board work with home assistant?
@Dylan_Lanckman
@Dylan_Lanckman Ай бұрын
@@KinCony yes that would be awesome
@KinCony
@KinCony Ай бұрын
@@Dylan_Lanckman ok, thanks for suggestion
@ruimarinho
@ruimarinho 3 ай бұрын
The new CT clamps look very good. What’s the max rating? Are they factory calibrated or should we calibrate them individually at arrival?
@KinCony
@KinCony 3 ай бұрын
not need calibrate , there are some different model of CT sensor, MAX support 100A version.
@walkastray007
@walkastray007 2 ай бұрын
Hey KinCony! I know it's probably obvious, but is there a reason we use a fuse instead of a circuit breaker? I'm quite new but would like to understand the design choice. Thanks! :D
@KinCony
@KinCony 2 ай бұрын
fuse only protect the DC12v power supply.others load all protect by breakers.
@jonathancolby9179
@jonathancolby9179 3 ай бұрын
Thank you! I am glad your making nice products and I have noticed your English getting better year over year. I used the 868COLB for a customer and it worked good ! System design with manual failover is very good idea! I like the small power meter rings.
@KinCony
@KinCony 3 ай бұрын
thanks, sorry, my English also is poor:)
@lionlion-g9d
@lionlion-g9d 3 ай бұрын
Very good. I liked kincony products ❤
@KinCony
@KinCony 3 ай бұрын
@@lionlion-g9d thanks
@fareedquraishi
@fareedquraishi 2 ай бұрын
Hi, can you please inform that how the wiring of a home is to be done as per your schema of DBs. As in South East Asia, Generally a single CB, controls a single room. In that sense, how should we go about thses type of DBs.
@KinCony
@KinCony 2 ай бұрын
you can make one DB, all wire connect with one DB. Or you can make multi DBs, every floor or every room use by a small DB, such as 8 channel or 16 channel version.
@martinspukitis1954
@martinspukitis1954 2 ай бұрын
Can you make a smaller energy meter? 10 or even 5 channel?
@KinCony
@KinCony 2 ай бұрын
yes, will make it in furture
@luciancotaie8803
@luciancotaie8803 20 күн бұрын
Why you dont use less mcb for lights. You dont need to put for every output own mcb
@KinCony
@KinCony 20 күн бұрын
yes, that will save space, good idea , some channels together with one MCB.
@abhirupbiswas5671
@abhirupbiswas5671 2 ай бұрын
what is the reason for using dc contactors?
@KinCony
@KinCony 2 ай бұрын
Will not generate interference signals and cause interference to other devices
@ruimarinho
@ruimarinho 3 ай бұрын
What’s the primary reason for using DC powered contactors?
@KinCony
@KinCony 3 ай бұрын
DC contactor will not cause interference
@ruimarinho
@ruimarinho 3 ай бұрын
Does the DC contactor work manually if the DC power supply dies?
@ibryxx
@ibryxx 3 ай бұрын
it should work..
@KinCony
@KinCony 3 ай бұрын
sure, this is important
@ruimarinho
@ruimarinho 3 ай бұрын
If I understood correctly, there are two redundancies: the A32 Pro software being broken where the manual switch can be used to trigger the contactor and the contactor itself if the A32 Pro dies or the DC PSU dies. Is this correct?
@KinCony
@KinCony 3 ай бұрын
@@ruimarinho yes, you are right.
@samza9
@samza9 2 ай бұрын
Can you make EC PH control kits for sale? Bro
@KinCony
@KinCony 2 ай бұрын
use for agriculture?
how to wire light socket switch cable for smart distribution panel
21:36
Every parent is like this ❤️💚💚💜💙
00:10
Like Asiya
Рет қаралды 20 МЛН
Installing the Leviton Whole Home Energy Monitor
11:45
Leviton
Рет қаралды 9 М.
Control Box Assembly #6
14:41
MindaugasV85
Рет қаралды 8 М.
Home Assistant Control Panel For My Wall
11:19
BorisDigital
Рет қаралды 288 М.
Home Automation 32CH Distribution Board DIY | Smart IOT Project 2023!
17:33
Open Source Smart Home HUB 2.0 for Home Assistant
20:36
Smart Solutions for Home
Рет қаралды 176 М.
Why Circuit Breakers DON'T Protect People (electric shocks)
18:23
The Engineering Mindset
Рет қаралды 1,3 МЛН