External Standard , Internal Standard, and Standard Addition | Chemistry with Dr. G

  Рет қаралды 24,783

Chemistry with Dr. G

Chemistry with Dr. G

Күн бұрын

Want more resources about General Chemistry. View my website at sites.google.c...

Пікірлер: 25
@siyabongamnyoni1699
@siyabongamnyoni1699 Жыл бұрын
Thank you for highlighting the differences between the quantifying techniques, Dr. G. Looking forward to more videos 👏👍
@ChemistrywithDrG
@ChemistrywithDrG Жыл бұрын
Glad it was helpful!
@yukinaminato
@yukinaminato Жыл бұрын
Thank you so much, sir! This video is really helpful.
@ChemistrywithDrG
@ChemistrywithDrG Жыл бұрын
Glad it was helpful! Thank you for letting me know.
@dhuhabariysa6869
@dhuhabariysa6869 10 ай бұрын
this was very helpful, thank you!
@ChemistrywithDrG
@ChemistrywithDrG 10 ай бұрын
Glad it was helpful!
@yunengliao6190
@yunengliao6190 9 ай бұрын
Good! thank you for sharing!
@ChemistrywithDrG
@ChemistrywithDrG 8 ай бұрын
Glad it was helpful
@didiez8678
@didiez8678 4 ай бұрын
So helpful, thank you so much !
@ChemistrywithDrG
@ChemistrywithDrG 3 ай бұрын
Glad it was helpful!
@normanbates6638
@normanbates6638 Жыл бұрын
Great video, thanks!
@ChemistrywithDrG
@ChemistrywithDrG Жыл бұрын
Great. Glad you liked it.
@devpatel2309
@devpatel2309 Жыл бұрын
thank you , keep it up
@ChemistrywithDrG
@ChemistrywithDrG Жыл бұрын
Glad to hear it is helpful.
@ivanbombana7282
@ivanbombana7282 10 ай бұрын
Good morning. What should I do to understand if I have matrix effect?
@ChemistrywithDrG
@ChemistrywithDrG 10 ай бұрын
You could think about measuring an external standard with a known concentration with the instrument. Then dope in the same standard analyte amount into the sample and see if you get the same signal increase in the doped standard as in the external standard. For example, an external standard with a concentration of 0.2 M gave a signal of 0.5. The sample gives a signal of 0.3 for the analyte. If the sample doped with 0.2 M gives a signal of 0.8 (the sum of the sample and the external sample signal) then there is no matrix effect. However if it differs from this then you know there is a matrix effect.
@user-rq6dx5ro3w
@user-rq6dx5ro3w 5 ай бұрын
Thank you sir, for your nice explanation. i have one question regarding standard addition. If the unknown concentration shows a negative signal(i.e S1(absorbance)= -0.1245) of arsenic due to matrix(salt) effect in an atomic absorption spectrometer then how i will calculate it from standard addition method? waiting for your kind response.
@ChemistrywithDrG
@ChemistrywithDrG 7 күн бұрын
This seems like that you would want to reconsider your blank that you used for the calibration of the instrument. Also, the arsenic concentration might be too low and below the LOD
@ChemistrywithDrG
@ChemistrywithDrG 7 күн бұрын
The concentration might be too low and below the LOD. Also, you would want to check the blank you use for calibration as they may contribute to the negative signal.
@PritomAhad
@PritomAhad 9 ай бұрын
So with internal standard, am i still getting a conc v signal graph nd using it to find conc of unknown?
@ChemistrywithDrG
@ChemistrywithDrG 7 ай бұрын
You will be using a comparison. You will have a standard solution that has a known amount of the analyte you are interested in quantifying (for example caffeine) and a known internal standard concentration added (for example benzoic acid) and get a signal for both caffeine (analyte) and benzoic acid (internal standard). Then you will add the same amount of benzoic acid to your unknown solution as an internal standard. Get the signal for both caffeine and benzoic acid, then compare the signals for caffeine and benzoic acid from the standard solution to the unknown solution.
@za7607
@za7607 Жыл бұрын
Great thank you! I have a question. how should I specify the maximum and minimum range for calibration carve while I have no idea about the concentration in my sample?
@ChemistrywithDrG
@ChemistrywithDrG 11 ай бұрын
Great question. If you are unaware of the concentration of your sample, you will want to do some research about the instrument you are using. What is the linear range possible with the instrument? What is the LOD or LOQ? Then, do a first test of your sample with a dilution, to make sure that the pure sample will not overload your detector or your analytical system. If it is low, then analyze the sample at higher and higher concentrations, until you get a significant signal.
@za7607
@za7607 11 ай бұрын
@@ChemistrywithDrG thank you for replying 🙂 so helpful !
@ChemistrywithDrG
@ChemistrywithDrG 10 ай бұрын
@@za7607 Glad it was helpful!
Internal Standards
14:04
ShortChemistry
Рет қаралды 48 М.
Commentary on Calibration Methods
17:23
Mark Lingwood
Рет қаралды 20 М.
Секрет фокусника! #shorts
00:15
Роман Magic
Рет қаралды 44 МЛН
Ik Heb Aardbeien Gemaakt Van Kip🍓🐔😋
00:41
Cool Tool SHORTS Netherlands
Рет қаралды 9 МЛН
Cute kitty gadgets 💛
00:24
TheSoul Music Family
Рет қаралды 17 МЛН
Analytical Science: Standard Additions Calibration
8:52
ChemEngTutor
Рет қаралды 47 М.
Spectrophotometers, calibration curves and Beer's Law
11:58
Katharine Hubbard
Рет қаралды 70 М.
5.2 External Standard Calibration
18:06
CC CH241
Рет қаралды 6 М.
Calibration Curves, Blanks, and Method Verification Terminology
27:17
The End of Haber Bosch
13:51
Reactions
Рет қаралды 178 М.
Calibration Methods
15:04
Dr. David Kreller Chemistry
Рет қаралды 94 М.
How to Set up HPLC calibration curve - External Standard Calibration Method
6:38
Calibration Curves 101 (UPDATED)
8:00
David Yazdi
Рет қаралды 37 М.
Секрет фокусника! #shorts
00:15
Роман Magic
Рет қаралды 44 МЛН