Finding Target Superheat

  Рет қаралды 21,271

HVAC School

HVAC School

Күн бұрын

Пікірлер: 19
@kelbymasey4453
@kelbymasey4453 Жыл бұрын
I appreciate his approach to teaching. Good job!
@carrieresammy
@carrieresammy Жыл бұрын
Appreciate the insight. Too many people feel like they know what range superheat should be which is fine, but if you’re not testing, you’re guessing!
@thrshr6669
@thrshr6669 Жыл бұрын
Awsome to watch and appreciate the tips/tricks/skills you are sharing with us all! Thanks!!!
@juancarlosfernandezmontero7935
@juancarlosfernandezmontero7935 Жыл бұрын
Greetings from Costa Rica. Well explained.
@bulentyavas6690
@bulentyavas6690 4 ай бұрын
First of all, I wish you success in your work. We will benefit greatly from your training and other study VIDEOS, but we would be very grateful if you could add Turkish to the subtitles. Greetings. I was able to write this article by translating it from translator. Thank you.
@rpsmith
@rpsmith Жыл бұрын
Excellent video! Very good presentation! Thanks!
@deanmartin1966
@deanmartin1966 Жыл бұрын
Great info. Thanks for sharing.
@markharmon6392
@markharmon6392 Жыл бұрын
I wonder if this method of finding targe superheat would work on a vehicle. Having trouble getting proper cooling from a 2008 Jeep Grand Cherokee I replaced the evaporator, dryer and TXV on a couple years ago, and it never has worked right. Evacuated and weighed in correct amount of refrigerant, but unsure exactly how much oil is in the system. Perhaps that's part of the problem, thinking of evacuating again, draining all oil from wherever I can get it out of easily, and starting over. Suggestions welcome, it's been many years since HVACR school in the Navy, and just the occasional job like this since. I just tuned up my JB vacuum pump and micron gauge (good for 15 micron verified by two separate micron gauges) and ready to try again. I think part of the problem last time was the vacuum pump wasn't pulling down remotely enough, and with my micron gauge contaminated, couldn't tell at the time.
@seek3n
@seek3n Жыл бұрын
I use the Emerson checkcharge app. It asks for vapor pressure vapor line temperature. And indoor wb outdoor db
@jericosha2842
@jericosha2842 Жыл бұрын
Why did Bert say to input the tonnage into MQ? Isn't return wetbulb and outdoor drybulb enough?
@rickhimes1385
@rickhimes1385 Жыл бұрын
Where is this school? This guy is a great instructor.
@craigmarshall40
@craigmarshall40 Жыл бұрын
Great video thank you 😊
@BigDon18
@BigDon18 4 ай бұрын
Does target super heat calc also work for the duct less mini split systems?
@jamesfitzsimmons381
@jamesfitzsimmons381 Жыл бұрын
Good job
@zachosborne6577
@zachosborne6577 Жыл бұрын
B E R T L I F E
@zesty2023
@zesty2023 Жыл бұрын
guy put me to sleep lol.
@mr.invisible3770
@mr.invisible3770 Жыл бұрын
How do you determine target superheat on water source heat pumps? Do you replace outdoor dry bulb with inlet water temp?
@enochian7133
@enochian7133 Жыл бұрын
Bert Life Beaches!
@jparson3309
@jparson3309 8 ай бұрын
Great video thanks for sharing
Class - What Superheat Signifies
17:07
HVAC School
Рет қаралды 248 М.
Чистка воды совком от денег
00:32
FD Vasya
Рет қаралды 4,1 МЛН
Lamborghini vs Smoke 😱
00:38
Topper Guild
Рет қаралды 30 МЛН
Wet bulb temperature - why & when is it used?
9:16
Process with Pat
Рет қаралды 81 М.
Mastering Superheat: The Trick to Charging an HVAC Unit
15:33
Mechanical Pros
Рет қаралды 33 М.
HVAC 052 Measuring Wet Bulb, Dry Bulb and Humidity
12:11
Love2HVAC with Ty Branaman
Рет қаралды 34 М.
What Should the Air Delta T be? (Air Temperature Split)
9:17
HVAC School
Рет қаралды 63 М.
Failed Compressors - Don't JUST REPLACE IT
24:59
HVAC School
Рет қаралды 67 М.
Practical Training on Manometers
18:58
HVAC School
Рет қаралды 23 М.
Explaining Superheat and Subcooling to Your Apprentice!
14:14
AC Service Tech LLC
Рет қаралды 638 М.
Saturation, Superheat,  Subcooling
30:58
Love2HVAC with Ty Branaman
Рет қаралды 204 М.
How To Check Superheat & Subcooling On An HVAC System
16:03
The DIY HVAC Guy
Рет қаралды 117 М.