Cool how he tested his own school's fire alarm system
@QueenKenziegaming7 ай бұрын
It is but we have to make Sure they all work because what if it was a real fire and they don’t go off if they makes sense
@Luke202-z8b2 ай бұрын
@QueenKenziegaming bro we know that mr. "Nothin' in life is fun 🤠". He is just making a complement. And there are certain jobs out there people like
@livestreammaster7 ай бұрын
The guy in the blue shirt looks like one of the people that nic in Canada works with
@Jdujfrewqadc11 ай бұрын
Was this taken during the night? Also when the alarm first started I heard a horn strobe but didn’t know where it was coming from. Do you know where it was coming from?
@SportyTrainGuy11 ай бұрын
This was taken during the night (if you do watch the full video, you’ll know). And there are horn strobes on the right side beyond the double doors at the beginning.
@Jdujfrewqadc11 ай бұрын
@@SportyTrainGuy oh ok
@themexicanmerc10 ай бұрын
school got speaker and horn strobes mixed 💀
@clxdyy_5 ай бұрын
its perfectly with code, and almost any school will put horn strobes in large areas and speaker strobes in other areas. sometimes the speakers will be too quiet for larger areas that may need reverb on the alarms.
@YoGGuy3 ай бұрын
Oh My God, Junior's Gonna Love School In America😍❤💙🤍🇺🇲
@jacobisworld951611 ай бұрын
How did you get to do it at night.
@LiamFire17B-R-qz2xr2 ай бұрын
I’ve seen this kind of system before where it has both truealert speaker strobes and horn strobes mixed. There’s an elementary school in Hamden, CT that I used to go to, and it has a simplex fire alarm system that has truealerts everywhere. The truealert horn strobes are all in the hallways, and in the classrooms. The speaker strobes are in the cafeteria, the gymnasium, and in the library. The library is huge, so they have the speaker strobes on the ceiling and a few on the walls.
@SomeDudeWithAnExitSign9 ай бұрын
The inspector that was in the video looks like a guy who would have a Simplex 4120 network in his basement
@AlfredoMartinezLobaton17 күн бұрын
Haag did the fire alarm test.
@achannelwithnopurpose197711 ай бұрын
Seems like a bigger system. I’m guessing it’s a 4100ES head end that is controlling an entire campus and has several annunciators tied to it (one per building). Need to ask though: does this system have miniplex transponders (basically cabinets that aren’t quite panels hooked up on the RUI circuit and is basically a step below a multiplex system)? Also, can I get some other specs on this system? Also, what system was original to this building that the 4100ES upgraded (I saw quickalert/early gen smartsync truealert horn strobe devices)?
@SportyTrainGuy11 ай бұрын
It used to be a 4100U
@achannelwithnopurpose197711 ай бұрын
@@SportyTrainGuy Cool. Lots of high schools in the school system I used to attend (including my old one) had 4100U systems, but they are being converted to EST. I managed to intercept one of these 4100U systems from a high school one zone over from my old high school before a panel/system swap to EST and got the parts after they were taken down. The panel came with everything standard on a 4100U plus an XPS, a 4120 card for the field house system, an additional IDNET 2+2 card, a mapnet legacy card for the old mapnet 2 devices from the original system before the 4100U (a 4020 that’s long gone), and oddly even a switch controller that had never had anything hooked up to it but was there regardless for whatever reason. If you go to the community tab on my channel, I snapped a couple of pictures just to tease and leak the system. I’m not gonna post a vid on it until I’m able to dump a new config on it and upgrade it to 12.08.02 to get rid of the troubles including a specific trouble (Pseudo Point P499) stating the firmware needs to be upgraded (hence why I’m upgrading to 12.08.02).
@officialsimplexguy10 ай бұрын
There’s 2 4100es systems networked together both formerly 4100Us. Looks like this system was originally a 2001 judging by the 2001 annunciator spotted at the beginning of the video.
@joeycaridi303010 ай бұрын
02:21 The speaker on the Wheelock ET70WP speaker strobe isn't working
@cg72409 ай бұрын
That was probably intentional. It looks like a newer alarm that was added on to comply with strobe coverage.
@SportyTrainGuy29 күн бұрын
Before, there was a problem with the speaker strobes playing 2 tones at once in that building (advisory tone + whoop/voice), here's the link to that video: kzbin.info_UmFIKeQwm8?feature=share
@BlueThunderboltFireAlarm-um4rp3 ай бұрын
What brand are the pull stations?
@michaelgonzales255911 ай бұрын
What day was this?
@SportyTrainGuy11 ай бұрын
Yesterday
@dale423111 ай бұрын
Do you know the history as to why your school has horns and speakers?
@SportyTrainGuy10 ай бұрын
No
@cg72409 ай бұрын
Usually there's a mixture of alarms whenever a building gets expanded or partially renovated. The area with speakers must be a newer area that was later added on.
@NewEnglandAviaton9873 ай бұрын
@@SportyTrainGuywe have speakers outside and in the gyms we have two gyms and horns in the halls and strobes in the classrooms ( in our high school) and our middle school only has speakers
@CentralVirginiaEAS10 ай бұрын
Looks like this was done at night lol.
@ministrygreene255610 ай бұрын
That mr True alert
@GaryBeltz10 ай бұрын
Why does the school have horn strobes in some areas but speaker strobes in the rest?
@cg72409 ай бұрын
Usually there's a mixture of alarms whenever a building gets expanded or partially renovated. The area with speakers must be a newer area that was later added on.
@Xavierstrainsandmotors6 ай бұрын
can you record the fire drill at florida school for the deaf and blind? 😊
@JMWtrainsnstuff4 ай бұрын
I feel like I've seen this school in a different video
@braydenfaw15685 ай бұрын
5:01
@mariorules888810 ай бұрын
If you get a chance can you please do a video of your school's bell system?
@jacobisworld951611 ай бұрын
Hate Horn Strobes.
@blose7748 ай бұрын
It could have been worse if it was a spectralert advance or wheelock or any horn on continuous.
@jacobisworld95167 ай бұрын
@@blose774I Don’t Understand Why They Have Horn Strobes And Speaker Strobes.
@blose7747 ай бұрын
@@jacobisworld9516 Probbaly since part of the building may be newer and they decided to upgrade to voice evac.(speaker strobes)My old school had horn strobes in the classrooms and voice evac in the gym,weight rooom,locker rooms,drama room,and pac and it was built in 2013.
@jacobisworld95167 ай бұрын
@@blose774 really
@blose7747 ай бұрын
@@jacobisworld9516 Yep,since voice evac is newer technology and is used on new buildings for the most part.
@Cam-SB10 ай бұрын
What happens if you're in a wheelchair and on the second floor?
@Justingaming89410 ай бұрын
I don’t know just try not to end up in one
@Cam-SB10 ай бұрын
@@Justingaming894 I have a physical disability; I'm already in one alot of the time when I'm out of the house.
@ittorchicer10 ай бұрын
Most commercial buildings have special chairs for disabled people that are carried by 2 other people meant for evacuation purposes.
@SportyTrainGuy10 ай бұрын
I think the school has some sort of transportation device that makes the wheelchair easier to go down the stairs. But I don't remember at the same time, so don't quote me on that lol