I understand setting the relief pressure at the highest pressure line but if you fit that line down won’t the lower psi lines spike up the pressure that your highest line is set at?
@TheRollSteady6 ай бұрын
You are on to something… and why gating lines down can be extremely problematic. This is why Rick Brewer advocates for utilizing multiple engines and setting up pressure zones for each apparatus to function in.
@ericfeatzka6484 жыл бұрын
Can you set the relief pressure just circulating water back to tank? Or is it best to set when flowing a hand line?
@TheRollSteady4 жыл бұрын
Good question. Personally, I prefer to set the relief valve with a dedicated discharge. A side note is to test different relief pressures as you do your morning check out.
@ericfeatzka6484 жыл бұрын
@@TheRollSteady Thank you
@kaelynhess80493 жыл бұрын
Where is part 10 of this series?
@TheRollSteady3 жыл бұрын
I had to pull some of these down. I’m in the process of re-doing this entire series though. You might be able to find the original episodes I pulled down still at therollsteady.com in our Pump School with Rick Brewer.
@donpietro58193 жыл бұрын
Hello I hope you are well I work in an oil company I am a fire truck driver I have a problem with the truck in the control panel when I accelerate the pump with the start button not I think because that discharge relief valve please help me
@TheRollSteady3 жыл бұрын
Sorry Don, I’m not sure what exactly you are asking.
@donpietro58193 жыл бұрын
@@TheRollSteady you have an email or Facebook to send you the photos and understand me please
@TheRollSteady3 жыл бұрын
@@donpietro5819 look up Roll Steady on Facebook
@jesusleon34933 жыл бұрын
@@TheRollSteady Good morning, could you explain to me how to configure my relief valve, thank you very much in advance
@TheRollSteady3 жыл бұрын
@@jesusleon3493 join us on Therollsteady.com I will be putting out a video on setting your relief valve in the next couple month or so
@christopher99752 жыл бұрын
How the heck does this guy write backwards so easily?