Firman generator whole house interlock backup power system T07571 THTHQLLX1 RV Guard 50amp

  Рет қаралды 26,282

Tennessee Yankee

Tennessee Yankee

Күн бұрын

Пікірлер: 54
@kristenzaldivar6338
@kristenzaldivar6338 Жыл бұрын
We have used the kzbin.infoUgkxOTeIs0vv4_9B5hsmnLsk9r930uDQLu_Y for probably 30 hours with our camper and it’s been great! The noise level is really only noticeable when running the AC and other appliances like the microwave, hair dryer, or coffee pot. It’s not huge like other ones and it has wheels so even at 90lbs, I can move it!
@TNYankee2020
@TNYankee2020 Жыл бұрын
Thanks for watching. I no longer have the cover.
@tyjones5019
@tyjones5019 Жыл бұрын
Just bought this same unit during the last winter cyclone. I'm planning on hooking it up like this. Thanks for the video, it seems very capable!
@rwstarke
@rwstarke 2 жыл бұрын
FYI .... the 50 Amp outlet on this generator has a 31 Amp circuit breaker. You may find out that your house A/C may not start without having a Soft Starter installed on the compressor unit.
@FDRGREG
@FDRGREG Жыл бұрын
Yes I got mine installed time, money, effort. Now no more power outages!
@TNYankee2020
@TNYankee2020 Жыл бұрын
Awesome. Ran 80% of my house this weekend on it with all the major windstorms.
@c.juneau410
@c.juneau410 4 ай бұрын
How did you do it? The same way??
@FDRGREG
@FDRGREG 4 ай бұрын
@@c.juneau410 yes pretty much. Running a 9500/12500 Westinghouse interlocked into a 50 amp breaker. Soft start on my HVAC outside unit. I keep the stove, hotwater heater, off. I installed current monitors on both legs of the 120v power inputs to monitor my watts consumption and total amount of load when running the generator. I still haven’t had to use it but a couple of brief times since installing everything about 4 years ago. I try to exercise the generator at least every other month.
@mikek8229
@mikek8229 2 жыл бұрын
Wow the safety police are always on patrol! Thanks TY for showing us your setup.
@TNYankee2020
@TNYankee2020 2 жыл бұрын
Thanks for watching Mike.
@pierremillette739
@pierremillette739 2 жыл бұрын
The Firman t07571 has a bounded neutral and your interlock allows sharing the neutral with the house resulting in bounding at the generator and at the main panel which is against NEC code.... This will cause parallel return current on neutral and ground in normal operation (not a good situation). The fix as per NEC is either to unbound the generator or install a tansfer switch that also switches neutral in which case you will also need to ground the generator.
@TNYankee2020
@TNYankee2020 2 жыл бұрын
Pierre, thanks for your feedback on this.
@pierremillette739
@pierremillette739 2 жыл бұрын
@@TNYankee2020 Please watch a very good video at kzbin.info/www/bejne/rJqxi4lmod6FjLM. It explains rules regarding bounding/grounding in a very simple way. Also check the associated web site article which complements the video nicely: homebatterybank.com/do-i-need-to-ground-a-generator-simply-explained/ Best of luck and keep safe! Pierre
@glennmartinez6155
@glennmartinez6155 2 жыл бұрын
Transfer switch the neutral. How do you do that.
@ChuckMorton
@ChuckMorton 5 ай бұрын
@@glennmartinez6155 its a seperate box, where you take certain circuits out, but a lot of transfer boxes only switch the hot, and in that case the neutral is tied to both the generator and the house panel.
@ChuckMorton
@ChuckMorton 5 ай бұрын
@@TNYankee2020 did you end up unbonding your generator? It is fairly easy, and I keep a bonding plug (Neutral to Ground tied in plug) in case I ever need to use the generator not hooked up to the house (and house ground to neutral bond point). I have the same generator and use NG but have about 25 gals of propane on hand as backup. I like the setup until I go solar/battery backup.
@billybassman21
@billybassman21 7 ай бұрын
Nice! Other than the hot tub you should be able to power everything including the AC as long as you don't turn too many appliances on at once. Also you may want to get a soft start or hard start kit for your AC. With my 10k doing less on natural gas I just brute force it on without turning anything off. My AC and fridge has a start delay, have UPS on the entertainment system, nothing is really going to surge. I'm just careful not to run too much as once. If I'm say running the microwave I won't have the coffee maker or toaster on. Switched most lighting to LED. AC has a hard start kit.
@TNYankee2020
@TNYankee2020 7 ай бұрын
It’s really worked out well for me. Thanks for watching.
@FliesGoodbyes
@FliesGoodbyes 2 жыл бұрын
Great Stuff. Thanks!!!! Plan on doing this soon. Want to get the soft start installed on ac first.
@TNYankee2020
@TNYankee2020 2 жыл бұрын
Thanks for the kind words and thanks for watching
@robb1460
@robb1460 Жыл бұрын
For the A/C Get an A/C Soft Start Kit. Cuts amps draw by 50%
@TNYankee2020
@TNYankee2020 Жыл бұрын
Thanks for the tip, never heard of such a thing.
@robb1460
@robb1460 Жыл бұрын
@@TNYankee2020 Now you have. The point here is to switch over without turning off all the breaks. Do a power use report. On how much power is on during day/nite. Change light bulbs to LED, Frig/Freezer, A/C, and Heater (low draw startup) with soft start, PC, and Everything that would be on and do not auto restart. See if you can just switch over. But turning off the A/C breaker would be the safe route. After switching over. Reset the A\/C breaker should all work. But do turn off all unneeded draws. don't use 1500 watt hair dryer etc.
@JoseOrtega-xn4mj
@JoseOrtega-xn4mj Жыл бұрын
Thanks for the de demonstration! Question I noticed you had PVC pipes on the side what do you use for?
@cpwatching5647
@cpwatching5647 2 жыл бұрын
Looks like a great setup. I like it!! Take care.
@TNYankee2020
@TNYankee2020 2 жыл бұрын
Thanks. :) Hope your snow plowing days are numbered.
@toyota4life326
@toyota4life326 10 ай бұрын
Where did you buy the generator cord or did you make one?
@TNYankee2020
@TNYankee2020 10 ай бұрын
Good question, sometimes it’s hard to see the updates in the description, but what was pictured in the video is not what I ended up with, I will summarize the changes below from the comments. To answer your question I originally made my cord but then decided to change it out later for a safer version, if someone other than me was ever hooking it up. I kept the original cord link below, but changed out the end to a twist lock also linked below. 50 amp 25’ Power Cord amzn.to/36UCKj5 After the video was up, I ended up changing out my plug end to a twist lock vs what came on the end of the power cord and I changed my box out as well. These are what i changed it out too: 50 amp Twist Lock amzn.to/3fl1hlF 50amp Power Inlet Box: amzn.to/3C0Q4hV
@Clockcash
@Clockcash 2 жыл бұрын
Great vid. Thanks
@tonyrollin402
@tonyrollin402 Жыл бұрын
Can you please Tell me where you got that cord I can't find one to save my life I need one exactly like the one you have
@TNYankee2020
@TNYankee2020 Жыл бұрын
Amazon see my link second in description
@scotthooper4170
@scotthooper4170 Жыл бұрын
Where did you get that cord? I like the bright green with a grip to identify it differently than a standard male/ Female standard extension cord.
@TNYankee2020
@TNYankee2020 Жыл бұрын
It's the second link in my description. I'm not using that cord anymore it was fine but I changed it out to a twist lock.
@scotthooper4170
@scotthooper4170 Жыл бұрын
@@TNYankee2020 thank you. That’s what I use professionally. But have the straight blade receptacle for RV’s. Generator uses that same straight blade.
@pierremillette739
@pierremillette739 2 жыл бұрын
I also plan to buy the T07571 and was wondering whether it is OK to use it to power 'modern smart' fridge you know those with gadgets such as WiFi etc... I have a Samsung fridge whose manual warns against powering it on a non-inverter generator. Do you have one of those recent sensitive fridge? And, if so did you power it successfully with the generator? Thanks, Pierre
@TNYankee2020
@TNYankee2020 2 жыл бұрын
My fridge is kind of fancy but it doesn’t have Wi-Fi I’ve run it off the generator
@edgarhernandez4572
@edgarhernandez4572 2 жыл бұрын
My understanding is that the T707571 burns up the rectifier if you disconnect the NG bond a the generator. I am going to call Firman to see if this also affects the T07573.
@TNYankee2020
@TNYankee2020 2 жыл бұрын
@@edgarhernandez4572 Thanks for your leg work, I haven’t done any modifications to my Firman. I have about 10 hours run time running my house on it.
@cascios
@cascios 2 жыл бұрын
Great video. What size wire did you run from your outside female outlet to your fuse panel?
@TNYankee2020
@TNYankee2020 2 жыл бұрын
Sorry, I can't help you with that part, I bought all the parts but the wire and had the electrician run it from outside into the panel. Whatever is code for 50amp breaker is what he would have ran. Thanks for watching.
@utrutr6013
@utrutr6013 2 жыл бұрын
I read people complaining about the loud noise this unit makes. My main concern more than the noise is dirty power it apparently provides. At 11%-14% THD, I'm concerned electronics will get damaged. Anyone have comments/opinions on this point?
@TNYankee2020
@TNYankee2020 2 жыл бұрын
Thanks for comment hopefully someone has feedback
@samlancaster5506
@samlancaster5506 2 жыл бұрын
I'm still just looking into getting a generator. I read in a post somewhere that you can just go buy a power back up unit for your more expensive electronics those should smooth out the power coming from the generator. Not sure it's true. But thought I'd let you know.
@kenjohnson961
@kenjohnson961 Жыл бұрын
You need an inverter generator for home back up, it delivers clean power that won't damage electronic, motors, and anything with a circuit board
@larryjanson4011
@larryjanson4011 Жыл бұрын
only the inverter generators make clean power. ALL of the "open frame" units also know as contractor generators make very "dirty" power. are very noisy, burn twice, or up to five times the fuel. (as a side note, some construction job sites are now banning them due to the DB levels being so high). but USE a manual lock out and/or a computer controlled swap over control. NEVER allow any juice from your generator to back feed into the grid. as you can kill a wire worker who believes the line to be dead. got a large battery bank?
@Teleman01
@Teleman01 Жыл бұрын
I was going to put a lockout switch like this on my outside panel. But unfortunately, the people who wired my house in the 90s did install a "main breaker" that cuts every single thing off in the house. It only has a breaker that turns off the panel inside the house, then there is a separate breaker for my garage HVAC, then a separate breaker for my house Hvac. So there are three breakers lol. So there's no way to put in a lockout that would lock out everything. I would have to get an electrician to rewire the whole panel to 200 amp service with a main breaker. Not paying for that lol....
@TNYankee2020
@TNYankee2020 Жыл бұрын
Sounds frustrating. Thanks for watching.
@tonyrollin402
@tonyrollin402 Жыл бұрын
I'm sorry I've checked the link that you have in the description I can't find that particular court anywhere That is a double male cord correct If so can you send me the link directly to the court or the information so I can find it
@TNYankee2020
@TNYankee2020 Жыл бұрын
Oh, the double male I originally used I made from that cord. I ordered another male end and changed it out. After much excoriation about it being a suicide cord I decided to change it out to a twist lock.
@tonyrollin402
@tonyrollin402 Жыл бұрын
@@TNYankee2020 lol oh that's what I'm going to do I thought I was going crazy I couldn't find that cord anywhere and it's only a suicide court when the power is running so if you plug it in before you start the generate her up and turn all your breakers off you'll be fine
@timgraham7851
@timgraham7851 2 жыл бұрын
Hack job.
@TNYankee2020
@TNYankee2020 2 жыл бұрын
👌
@PeterLawton
@PeterLawton Жыл бұрын
It looks like you're just trolling, or maybe sarcastic. This installation looks top notch.
4 Generator Hacks by an Electrician
6:45
abrelectric
Рет қаралды 316 М.
А ВЫ ЛЮБИТЕ ШКОЛУ?? #shorts
00:20
Паша Осадчий
Рет қаралды 8 МЛН
Please Help This Superhero! 🙏
00:48
Alan Chikin Chow
Рет қаралды 6 МЛН
HAH Chaos in the Bathroom 🚽✨ Smart Tools for the Throne 😜
00:49
123 GO! Kevin
Рет қаралды 14 МЛН
Пришёл к другу на ночёвку 😂
01:00
Cadrol&Fatich
Рет қаралды 11 МЛН
Save thousands on Backup Power System For Your House. Part 1.
10:42
David Georgia: Personal Preparedness & Finance
Рет қаралды 40 М.
FIRMAN TRI-FUEL GENERATOR - TOP FIVE QUESTIONS ANSWERED (review)
17:59
TOOLMAN TIM'S WORKSHOP
Рет қаралды 67 М.
How To Get Whole Home Backup Power For Under $1000
9:03
The DIY HVAC Guy
Рет қаралды 1,1 МЛН
Whole House Power Backup Solution | Generator Inlet Box Install
12:22
Everyday Home Repairs
Рет қаралды 797 М.
34. FIRST TEST OF MY WHOLE HOUSE GENERATOR SET UP (How Did The Firman Trifuel Do?)
24:30
7 Backup Generator Mistakes. (Have You Made One?)
8:11
Backyard Maine
Рет қаралды 437 М.
Cheap & Easy Way to Connect a Generator to Your House - Legal Too!
8:19
90% Don't Know About This Fatal Generator Connection
11:17
HAXMAN
Рет қаралды 723 М.
Don't Buy A Backup Generator Until You See This!
20:44
Haxman XTRA
Рет қаралды 434 М.
А ВЫ ЛЮБИТЕ ШКОЛУ?? #shorts
00:20
Паша Осадчий
Рет қаралды 8 МЛН