this video helped me to learn about how Floating head exchanger and hydro test procedure, and the explanation was outstanding and briefly explained shell side tube side and final hydro test procedure.
@Oilandgasacademy11 ай бұрын
Thanks for your valuable comment 🙏🏽
@husainjam11 ай бұрын
Can u suggest a text book to learn about the geometry of shell and tube heat exchangers ?
@k.alangaramkuppan19110 ай бұрын
Very good making video and very useful video... Thank you brother
@mufeez339 ай бұрын
Bro very good explanation 🥳
@ssnarayanans10 ай бұрын
Use full video bro
@Oilandgasacademy10 ай бұрын
Thank you so much
@pravinradhakrishnan72462 ай бұрын
Hello bro...I have one question Why we are using floating head in exchangers...I means what is the purposes of floating head....?
@puttalu19823 ай бұрын
how do you make this animation? amazing!
@lalithkaran18616 ай бұрын
Super sir , very use full thank you so much
@abdabdullah6573 Жыл бұрын
Very useful video sir
@Oilandgasacademy Жыл бұрын
Keep watching
@ArockiaAntonyRaj-g5k9 ай бұрын
I am very clear now thank you bro
@selvinsuther11 ай бұрын
Very useful bro
@Oilandgasacademy11 ай бұрын
Thanks a lot
@mubarakstar9 ай бұрын
Thank for the video it's very helpful... one doubt brother.. Can we use Air-condition Outdoor and its coil inside the Tube bundle instead of water fluid for cooling purpose??
@Oilandgasacademy9 ай бұрын
Thanks...I am not understanding your question bro...
@mubarakstar9 ай бұрын
@@Oilandgasacademy brother Water fluid cooler inside la water ku bathila andha cooler oda copper tube hole la AC la outdoor la small copper coil gas cross panni AC cool pannumla atha water ku bathila AC outdoor tube ah wrap pannalama? Water tank +motor + outside chiller ellam micham thane ore AC outdoor second hand la oru 7000 ku vanguna pothum la .. Ipdi panna workout aaguma? Ungaloda suggestion sollunga pls
@Oilandgasacademy9 ай бұрын
@@mubarakstar 😀 bro ..no idea...actual intha channel la oil and gas la ulla static equipment related pathithan poduren. neenga kekurathu AC unit ah pathi solreenga sorry ...
@mubarakstar9 ай бұрын
@Oilandgasacademy Thank you brother 🙏 ❤️
@mahadhoombasila4333 Жыл бұрын
Super bro ❤
@Oilandgasacademy Жыл бұрын
Thanks 🤗
@jojips949510 ай бұрын
How to connect the fitting for hydro test ( gauge and prv )if there is no provision on inlet and outlet nozzles.
@Oilandgasacademy10 ай бұрын
As far as I understand your question, my answer is that if there is no vent and drain connection at the inlet and outlet ends, a special arrangement at the inlet flange and outlet flange should be done with a test spade at that location for hydrotesting.
@msdmsd3562 Жыл бұрын
Very nice
@mohamedmeerasahib452510 ай бұрын
Casket ethana varum.. All exchanger kum. Thani video podunga