Flow table test of concrete / flow table test / flow table test procedure / Concrete testing

  Рет қаралды 34,111

Saral Mechanical

Saral Mechanical

Күн бұрын

#testing #concrete #concretetesting
Flow table test of concrete
flow table test
flow table test procedure
flow table test apparatus
flow table test apparatus dimensions
flow table test calculation
flow table test standard
flow table test result
flow table test ppt
flow table test for mortar
Procedure for Concrete Flow table Test
about video
Flow table test of concrete
Flow table test of concrete also determines the Quality of Concrete concerning its consistency, cohesiveness and the proneness to segregation.This test for self compacting concrete where reinforce is congested and compaction not possible by vibrator.
Slump test of concrete video link
• Slump test of concrete...
technical study for SSC & BANK & RAILWAY & OTHER GOVT. EXAM
current affair playlist
• current affairs for st...
engineering and technical play list
• current affairs for st...

Пікірлер: 45
@zubairparkar3153
@zubairparkar3153 Жыл бұрын
Nice video... With full details.. Practical video hota to aur maza ajata
@royalrawvikash1374
@royalrawvikash1374 Жыл бұрын
note :- 15 times in 15 seconds
@er.abhishekdhakad
@er.abhishekdhakad 4 ай бұрын
15 time in 60 second
@sandie1306
@sandie1306 3 ай бұрын
15 times in 45 sec as per Indian IS CODE .....but 60 sec b lete h , jo American IS code m h
@KMFamilyFun
@KMFamilyFun 2 ай бұрын
what is the acceptance criteria by doing this test
@saralmechanical
@saralmechanical 2 ай бұрын
it is there
@chirag11931
@chirag11931 Жыл бұрын
Value range after vertical & horizontal calculation,please mark?? Note :- What should be correct range with 10mm & 20 mm aggregate?
@ashishmohapatra5412
@ashishmohapatra5412 9 ай бұрын
Sir bahut acha laga
@saralmechanical
@saralmechanical 9 ай бұрын
thx
@onlinetamizha6260
@onlinetamizha6260 Жыл бұрын
Flow range limit how much and IS reference which following....
@mdfaizalam2246
@mdfaizalam2246 5 ай бұрын
Sir formula ka use kaise karna hai
@Hungryhemant
@Hungryhemant 3 жыл бұрын
Thank you sir...👌 Sabhi test sikhne h mujhe....joki mere lye bhut jauri hai ...ummed krta hu apki madat se m all testing sikh paunga ye mera phle test tha jo apki help se clear hua .. Mujhe ye janna hai sir ....isme D¹ & D² ki reading kis unit m hogi cm Mai or Mm Mai? I am average student
@saralmechanical
@saralmechanical 3 жыл бұрын
in this test unit cm mai li jayengi. i upload max test u can learn that test on my channel
@nanakchand3332
@nanakchand3332 3 жыл бұрын
mm
@JitendraKumarVerma-rn8bd
@JitendraKumarVerma-rn8bd 4 ай бұрын
Flow table ka cone kitna height me uthaya jata hai
@saralmechanical
@saralmechanical 4 ай бұрын
40 MM ABOVE FROM BASE
@ranjeetkumar-jk1uo
@ranjeetkumar-jk1uo Жыл бұрын
38 mm coarse aggregate scc me hota hai kya?
@saralmechanical
@saralmechanical Жыл бұрын
yes
@belalmallick97
@belalmallick97 Жыл бұрын
We are using 10mm aggregate maximum time at our site, but max 20mm we are using.
@saralmechanical
@saralmechanical Жыл бұрын
@@belalmallick97 38 ix max size for testing
@shahidsaleem256
@shahidsaleem256 2 жыл бұрын
Excellent
@quickmovietime1075
@quickmovietime1075 2 жыл бұрын
Doosra videos main flow table test kuch aur process nd apparatus dikha raha hain, wo v kya flow table test hai ???
@saralmechanical
@saralmechanical 2 жыл бұрын
u can send me link for other video so i can tell u what is diffrenece
@sadhiqbasha6240
@sadhiqbasha6240 9 ай бұрын
What is limit for flow?
@arunsiddhpura7040
@arunsiddhpura7040 6 ай бұрын
You have not told which result is good for approval and which concrete of flow diameter will not be suitable
@mdayyaz9344
@mdayyaz9344 Жыл бұрын
Value kaise nikalta h
@Hungryhemant
@Hungryhemant 3 жыл бұрын
Sir Vfunnel L box Sieve segregation test pr video bnegi?
@saralmechanical
@saralmechanical 3 жыл бұрын
i m busy with a project if i will free sure make a video on this topic
@sukantipujaimissyoubijayas9179
@sukantipujaimissyoubijayas9179 2 жыл бұрын
Thanks so much sir
@SagarGhorpade-u7z
@SagarGhorpade-u7z 11 ай бұрын
IS code No for this taste
@saralmechanical
@saralmechanical 11 ай бұрын
5512 1983
@kazizimran2228
@kazizimran2228 2 жыл бұрын
Thnx sir ji🙏👍
@meshanqamar4498
@meshanqamar4498 7 ай бұрын
full calculation of this test please sir
@saralmechanical
@saralmechanical 7 ай бұрын
calculation is there
@wonderingcivil8808
@wonderingcivil8808 2 жыл бұрын
Thanks
@ranjeetkumar-jk1uo
@ranjeetkumar-jk1uo 2 жыл бұрын
Limitation ke bare me aapne bataya nahi??
@saralmechanical
@saralmechanical 2 жыл бұрын
kindly watch properly
@Faizanali-kl4je
@Faizanali-kl4je 2 жыл бұрын
Sir slump test kese krte hai
@saralmechanical
@saralmechanical 2 жыл бұрын
video hai channel par u can watch
@vikasbatra2009
@vikasbatra2009 2 жыл бұрын
Limit in flow test
@monojsaikia9390
@monojsaikia9390 Жыл бұрын
Sir kon sa is code ke adhar per ye test hai
@saralmechanical
@saralmechanical Жыл бұрын
flow table test is covered with BS 1881 part 105 of 1984 and DIN 1048 part I.
@AjyBaghel001
@AjyBaghel001 11 ай бұрын
Is code 1199/2018 🎉😊 brother ❤️🚩
@mdfaizalam2246
@mdfaizalam2246 5 ай бұрын
Plz guide
@nafeesahmad2313
@nafeesahmad2313 2 жыл бұрын
Thanks sir
Concrete Flow Table Test as per Latest IS 1199-2018 | Learning Civil Technology
26:07
Learning Civil Technology
Рет қаралды 23 М.
Wall Rebound Challenge 🙈😱
00:34
Celine Dept
Рет қаралды 23 МЛН
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 30 МЛН
My scorpion was taken away from me 😢
00:55
TyphoonFast 5
Рет қаралды 1,7 МЛН
Self compacting concrete & slump flow test procedure
9:10
Concrete Engineers
Рет қаралды 2,8 М.
Concrete core cutting & Lab testing procedure.
17:46
R B Singh Civil Engineering Academy
Рет қаралды 39 М.
Slump test of concrete in hindi
11:48
Civil Notebook
Рет қаралды 24 М.