Mein ne bohat videos deki magar Apse achi details kisi ny nhi btai. Jazak Allah
@TechnicianBhai6 ай бұрын
Thanks
@imshaji26 ай бұрын
Meny kal NMC 2500 pv3000 lgwaya hy. Kia ye acha inverter hy ya bora.
@imshaji26 ай бұрын
Display same ap waly inverter ki tarha he hy
@penink13036 ай бұрын
💯💯💯 Agree
@TechnicianBhai4 ай бұрын
@@imshaji2 g sb ka board same he hota hai sirf body shape or brand name aleg hota hai...
@abdulmannanrkg45847 ай бұрын
السلام علیکم ورحمۃاللہ وبرکاتہ ماشاءاللہ آپ نے بہت بہترین انداز میں inverter کیsettingکرنےکاطریقہ سمجھایا ہے الله تعالیٰ آپ کو جزائے خیر عطا فرمائے آمین
@drrafiquebhatti20197 ай бұрын
Masha Allah 🎉
@ShahzadKhan-m8d6 ай бұрын
Very detailed and nice way of explanation. thumbs up
@hashirakhtar-w3m5 ай бұрын
Sir rat ko jab wapda pe shift hota ha to 3 ya 3.6 amp lord leta ha wapda se ma sirf aek dc fan use karta ho ya frig on bi kar lon tab bi 3.5 amp leta ha wapda
@penink13036 ай бұрын
Sir, Thanks you very much... I have lost 60k upon this system,and reason was that I didn't know about the user manual.... Once again thanks...❤
@mustafahyderlangah13505 ай бұрын
Kese bhai?
@penink13032 ай бұрын
Because if you don't know about all the functions properly and on the other side you can't use the user manual because of excessive technical terms.
@hashirakhtar-w3m5 ай бұрын
Hi sir mare pas pv 3200 new modal me ha 2024 butt aek problam a rahi ha ratt ko jab wapda pe shift ho to ac 3 ampeer hi rahta ha use kuch ho ya na ho agar frig bi use kar lo tab bi 3ya 3.5 HOTA ha use na karo tab bi sir bucht tenshan me plz ansar Dan
@TechnicianBhai5 ай бұрын
Question clear kar dae. Smj ni i
@khurramshahzad91367 ай бұрын
Bhai Boht ache andaz me samjhya hy apne is trah to jis ne pasay ly ker install kia hy us ne b nahi samjhaya hum ko..
@TechnicianBhai7 ай бұрын
Thanks
@syedfahadaliforsage27943 ай бұрын
Bhai frinus PV 2200 reborn ki setting bhi bata dain. Or heavy load cut off setting kese hogi pv 2200 reborn me.
@yasirdaud-p8m8 ай бұрын
Informative n well explained. ❤
@hashirakhtar-w3m5 ай бұрын
Hi sir mare pas pv 3200 new modal me ha 2024 butt aek problam a rahi ha ratt ko jab wapda pe shift ho to ac 3 ampeer hi rahta ha use kuch ho ya na ho
@TechnicianBhai3 ай бұрын
Woh capacitor charge discharge hote hain inverter k ess wajha se clamp meter 0er show hota hai only. Digital energy Meter per reading count nahi karta
@Ghazanfar7615 ай бұрын
Thanks bro bht acha smjhaiya apny
@tahirmakwal34007 ай бұрын
Brother Fronus PV 5200 ki bhi yahi setting kar sakty hain
@TechnicianBhai7 ай бұрын
Yes pv 3200 or pv5200 ki same current voltage ki setting ho gi.
@muhammadosamasiddiqui3500 Жыл бұрын
Behtreen Video Banai ha ap ne Informative
@islamkiroshni26119 ай бұрын
السلام علیکم Allah ap ko jaza e khair de bhai bht achi video bnai ha Maine pv 3200 k sath 220 ki 2 batteries leli ha bhai thori tips dedo behtr installation k liye
@islamkiroshni26119 ай бұрын
Bhai 3200 with 3 panel 570 watt or 2 batteries 220a k liye b video bna do ya tips bta do
@TechnicianBhai9 ай бұрын
@@islamkiroshni2611 panels series main laga dae 3no. Or baki jo setting btai hai uss hisab se kar lae
@MubashirYasin-u8l9 ай бұрын
Salam, Aap ko di hui saari settings kar li PV3200 ki. Ab trouble yeh he k SUB pe rakhen to subah k time charging karta rehta he load nahi uthaata jab tak battery full na hojaye. Or sham ko jab solar current kam hota he to b battery pe shift hojata he. Agar MKS pe rakhen to bhe subah k time battery pe shift kar deta he jab tak solar current poora na aajaye. Q? Battery only solar and SNU dono pe kar k dekh li he 5 din. Batteries 145AH ki 2 hen. Ab kya kiya jaye?
@TechnicianBhai9 ай бұрын
@@MubashirYasin-u8l 13 no setting load uthane ki hai. 13 no setting ko jitna kam rakhe gae load utna jaldi utha lae ga. 27.2v kar dae
@AsgharKhan-sj4jx4 ай бұрын
Mansha Allah boht malomati video hy. Bhai mery pass bhi fronus 2200 hy jis k sath mein ne 190 AH ki bty lagai huwi hy. Is ka backup kam hy Kia mein is k sath aik aur bty laga sakta houn. Bty kaise lagaun k volt 12 hi rahein lekin Amp barh jain. Aap ne batya k 2 btys parallel mein laga sakte hein. Us ka kia tarika hy aur is ka faida kia ho ga. Dono btys same honi chahiye ya chhoti barhi ho sakti hein. Shukria
@TechnicianBhai4 ай бұрын
G 2 battery parallel main laga sakte hain same company or same rating ki old or new ko bhi sath ni laga sakte... Parallel connection ka tareeqa yeh hai k battery k positive ko positive k sath or negative ko negative k sath milana hai. Or output aik positive se or aik negative se lae ly
@TechnicianBhai4 ай бұрын
G 2 battery parallel main laga sakte hain same company or same rating ki old or new ko bhi sath ni laga sakte... Parallel connection ka tareeqa yeh hai k battery k positive ko positive k sath or negative ko negative k sath milana hai. Or output aik positive se or aik negative se lae ly
@AsgharKhan-sj4jx4 ай бұрын
@@TechnicianBhai aap ka boht shukria. Samj aa gai. Jazak Allah.
@iqraqureshi7 ай бұрын
Exide 2500 ah wale tubular battery k leye better setting kaun se rkhne h fronus pv 2200 k leye . 02 wale m ktny Ampere rkhe ? Aur. 26 aur 27 m ktna rkhe. .. aur battery k max charge setting ktny rkhe ful per rkhe ya 14.2 per rkhe. Kindly iska rep den . Ya koe video bnae ispe
@MuhammadAli-zi9ue Жыл бұрын
Buhut achi video banayi bhai aapne Allah khush rakhey apko aur hamesha kamiyab krey ameen😊 I also liked and subscribed your channel.
@TechnicianBhai Жыл бұрын
Thanks u ☺️
@m.usmankhalil692711 ай бұрын
❤ New subscriber sir off-grid ki settings b explain Karen thanks
@waqarahmad79868 ай бұрын
A. O. A Bhai Osaka ki tall tubular battery hai 160AH Pro. Is k liye kitna charging current rakhen.. 10% k hisab sy daikhen to 16 amp bnta hai lekin 16 amp ka option nahi hai inverter mn
@mustafahyderlangah13505 ай бұрын
Same question
@imranaslam87096 ай бұрын
❤ Nice video Bahi jan
@danialkhan38710 ай бұрын
Me abhi konsa inventor lo mere pas 2 pannal he 550 wala ye 2200 pv wala lelo abhi ya nhi
@zaibabbasi49687 ай бұрын
Sir hamry ghr my fronus 3200 hy agr sitting my help krdyn to mihrabani hogi q ky hamy ye samj ni ata ky is pr kitna load dalna chahye matlab istre or washing machine or fans kitny chalany chahye
@TechnicianBhai7 ай бұрын
03064724536 only whattsapp
@zaibabbasi49687 ай бұрын
@@TechnicianBhai thanks
@incongnito7129 Жыл бұрын
Thank you Bhai, for making this video, it saved me alot of time and effort
@TechnicianBhai Жыл бұрын
Thanks u
@Unknownunknown12483 Жыл бұрын
Bro you earn my Respect and subscription too love you and God bless you ❤️
@HM-Ventures Жыл бұрын
Sath aap nay tublar our non tublar kay cut off voltage alag alag nahein batai 29 number setting may. And thanks for video really amazing work.
@TechnicianBhai Жыл бұрын
Woh tubler k 10.2v rakh dae or non tubler k 10.4v rakh dae
@alimansoob42618 ай бұрын
Mera pv 3200 hey setting 29 pey 20 volt set hey mey usko change kerna chah rhaa hun but hou nhee rhaa ? Plz guide@@TechnicianBhai
@TechnicianBhai8 ай бұрын
@@alimansoob4261 26,27 aur 29 number setting tab change ho gi agar 05 number setting USE per ho gi
@muhammadtahakhan83884 ай бұрын
Meri lead acid 2 battries hai 2200 12V ki . Kia setting rkhni hai?
@TechnicianBhai4 ай бұрын
Voltages sb setting main same rakhne hain or charging current 40amp
@sabihakhawar43154 ай бұрын
Pb
@cricketlovers-pj8eh13 күн бұрын
Aoa bhai mery pas pv 3200 se lakin rat ko wapda se bypass mode pe hota ha battery charge nai krta frequncy 50.HZ bi ho tab bi nai krta kabi start karta ha kabi kabi wapda volatge bi 210 se 220 hotay ha please is ka koi hal bata de
@TechnicianBhai13 күн бұрын
Ap ne 16 number oso per rakhi ho gi usay cso kar dae
@shahidalvi67888 ай бұрын
Mery pas 110ah ki 2 batteries lagi hain kitni amp select kru?
@ghulammurtazazaur5 ай бұрын
Bhai agar main pv3200 main 11 number utility charging ko 20A rakhon to kuch masla to nhn hoga batteries main plz reply krna
@TechnicianBhai5 ай бұрын
Nahi koi issue nahi ho ga
@ghulammurtazazaur5 ай бұрын
@@TechnicianBhai Thank you
@muhammadtahakhan83883 ай бұрын
Techorse lead acid 12-200 AH deep cycle ki battries k voltages kitnh rkhny hai? Kyun k ye used battery hai aur backup raat ko bht kam derhi hai. Isky low dc cut off voltage kitny hony chahiye? Mere pas 2 battries lgi hui hain fronus 2200k sth
@TechnicianBhai3 ай бұрын
26. 14.8v 27. 13.6v
@muhammadtahakhan83883 ай бұрын
Charging amp kia rkhun?
@TechnicianBhai2 ай бұрын
@@muhammadtahakhan8388 20
@ubaidshah46948 ай бұрын
Sir 185 amp ki saimple. Battery k liya charging current Kitna rakain.o plzz user-defined sutting b bata dain
@TechnicianBhai8 ай бұрын
20a. Or user defined rakhne ap 26,27 or 29 number ki setting khod kar sakte hain
@kingofkings79927 ай бұрын
@@TechnicianBhaipv3200 mai 185amp ki tublar battery hy ampire setting kitni rako 40?
@TechnicianBhai7 ай бұрын
@@kingofkings7992 20
@kingofkings79927 ай бұрын
@@TechnicianBhai backup nea milta 20 py
@TechnicianBhai7 ай бұрын
@@kingofkings7992 12, 13, 26,27 or 29 number setting video k mutabiq rakhe.
@bhattigarmentspindigheb619610 ай бұрын
Bhai nice video.pv3200 sbu pr hy.12 no setting 21v pr hy.lkn jb sham solr crunt off krta hy to batry 24v tk ati hy wapda py shift ho jata hy.hal bta den
@TechnicianBhai10 ай бұрын
Ap ne setting SUB rakhi ho gi agar setting SBU kare gae to tab jab tak battery k 21v nahi hn gae wapda per shift nahi ho ga
@Qkvideos47 ай бұрын
Sir hamra pv 3200 invter he jo hi sham hoti he wo beep karta he battery b belkol new error koi show ni karta he kindly aska solution bata dey
@TechnicianBhai7 ай бұрын
22 number setting ko off kar dae. Agr phr bhi issue ho to 18 number se bhi kar sakte
@Qkvideos47 ай бұрын
Dosra bahi hamne 16 setting pay battery KO sirf OSO pay raka he but jab Raat KO battery Ka backup khatam hojata he to battery wapada say charge Hoti he
@TechnicianBhai7 ай бұрын
@@Qkvideos4 software updated hai 007?
@Qkvideos47 ай бұрын
G updated he 007 but per b wapada say battery charge Hoti he halnke 16 no setting mey mene OSO Kia he
@shehzadpathan9278 ай бұрын
Aoa sir pv3200 ma kitny pannel lg sakty hn or kia pv 3200 hair ka 1.5 invertor chala sakta hy without wapda shring
@TechnicianBhai8 ай бұрын
Wese to mppt range 400v tak hai but ap 7 panels se ziada na lagae. Or 1.5t Easley chal jae ga. Kam se kam 6 panels hone chaie
@DailyDriver-qx5hn21 күн бұрын
Sir battery charge hona band nahin ker rahin i have 2 batteries on pv 3200 and selected the settings that you mentioned in the video
@DailyDriver-qx5hn21 күн бұрын
29.2 v per bhi keep on changing
@mehtabalijatoi37818 ай бұрын
Bhai software update sy inverter ke efficiency py koi farq aata ha 001 ka software ha
@TechnicianBhai8 ай бұрын
Efficiency 10% se 100% ho jati hai. 001 software ki solar power 200w per stuck ho jati hai
@miansohaib33638 ай бұрын
jazakallah, very informative brother 🎉
@junaidshah65669 ай бұрын
Pv 3200 new install kia hae 280 ampire ke 2 batteries hn new.back up bhot km ml rha hae . battery gravity zero hae .kia kren k gravity theak ho jy?
@hamzamurad4318 Жыл бұрын
Salam bhai mere pv 2200 me new software he 007 or isko as a ups use kr raha ho solar pannel nhi lgy hoye.. Tx 1800 tubular battery he 185 ah ki.. Charging ki default setting 60 amp he isko change kro ya thk he?
@TechnicianBhai Жыл бұрын
20amp kar dae warna battery kharab ho jae gi.
@X4HIL5 ай бұрын
Sir Pv3200 Latest model hai mere pass. 16# setting OSO hai Par Charging Still Utility Par Kar Raha Ha.
@TechnicianBhai5 ай бұрын
Asa hona to ni chaie oso per sirf solar se charging hoti hai. Apka software 007 ha?
@X4HIL5 ай бұрын
@@TechnicianBhai borther check kesay karna hai.
@TechnicianBhai5 ай бұрын
@@X4HIL ess video main bhi btaya hai shuru m
@Ubaidahmeddinmuhammad3 ай бұрын
@@TechnicianBhaibhai maira inverter ka software 007 hai OS mai bhi yahi masla kar raha hai
2 number setting may ager two 250ah ki batteries series may lagi hon to current kia rakhain gay matlab 20 ya 30? Sath ager charging preference solar then utility rakha ho to 2 or 11 ki kia setting rakhain gay?
@TechnicianBhai Жыл бұрын
Pv 3200 main 2no battery series main he lagti hain or 2no k lie 20a ya 30a bhi rakh sakte hain
@TechnicianBhai Жыл бұрын
30a per battery jaldi charge ho jae gi or but battery ki life thori kam ho jae gi. 20a per battery ki life theak rahti
@HM-Ventures Жыл бұрын
@@TechnicianBhai g bilkul theek kaha aap nay, yeah trade off ho ga, waisay slow charging bhee battery ki life kum ker daiti hai. I think behtar hai 200Ah ki batteries li jayn jo 20AH ko match kerti hain exactly
@HaiderAli-uc8xp6 ай бұрын
Bhai mene pv200 ki setting SBU pr ki ha but phir b ye show kr raha ha ke solar ke sath wapda b electricity ghar ko pass kr raha ha. Halan ke is option pr electricity main se pass nahi krni chahiay. Just grid show krna chahiay. Plz solution bata dein.
@aftaabhussain787110 ай бұрын
Nice and detailed video. Helped me alot
@Muhammadusman-to2tw10 ай бұрын
Slam bhi. Please trion wis 3600 ki setting ki video bna dain.
@MArif-fx2fe6 ай бұрын
Sir many inverter ki setting video instructions k mutabik ki hai.. Ab issue yha a rhaa...jasy hi wapda light jati..pora solar setup power dena off kr detaa...chahya din k 12 bjy hn..battry bi full charge backup p hoti.. Jasy wapda jati...yha UPS ki trah backup power (Solar, battery) nai dy rha...off ho jata sb .. Breaker s solar krna parta.. Yha inverter automatic q nai kr rhaa... Kndly iska solution to bta den...
@TechnicianBhai6 ай бұрын
Ap yeh setting kar dae 01. SBU 12. 12v 13. 13.6v
@TechnicianBhai6 ай бұрын
Baki backup ka issue sb ka hai ap helpline per complain kare ho sakta hai company phr new software update jari kar dae
@kkmmsskardu49799 ай бұрын
Temperature ap n default p kyn rakha ha Es ko enable rakha tou kya hogah
@TechnicianBhai9 ай бұрын
Enable kare gae to over temprature per restart ho jae ga. Jab k disable per restart nahi ho ga balkay alarm dae ga. Or load chalta rahe ga.
@AamirFarooq-f9f6 ай бұрын
Assalam O Alikum Which battery best for 3 kw inverter Kindly give your advice.
@TechnicianBhai6 ай бұрын
Tubler phoniex
@sohailmalik4u6 ай бұрын
AoA software kaisay update hoga pv 3200 ka 001 hai kindly guide me.
bhai ye jo inverter extra electricity wapda ko wapis bhej kar meter reverse me chalata hai wo kon se inverter pe hota hai?
@TechnicianBhai9 ай бұрын
Woh on grid solar inverter hote hain. Yeh hybrid solar inverter hain
@alishah34947 ай бұрын
v good vedio lekin mery pv 3200 men msla aa rha hai k wo jinko 545 watt ki panal py Ac nai chalata batrry use krny lag jata hai or 2200 watt k bad over load hojata ha
@alihasnain8514 Жыл бұрын
Very useful information. Thanks brother ❤
@maryamxcarain68367 ай бұрын
iske sath kam se kam kitne wali battery laga sakte? aur ap kis shahar se hain... agar is ke proper setting ap se karwani ho?
@abroazhar7 ай бұрын
please
@TechnicianBhai7 ай бұрын
03064724536 only whattsapp
@riffatparveen7796 ай бұрын
Sir ap kdr se ha hume b solrs ka boot masla ha
@TechnicianBhai6 ай бұрын
03064724536 whattsapp
@muhammadsalman13816 ай бұрын
BRO DUAL OPTION WALAY INVERTER MAIN HEAV LOAD CUTOFF KI POORI SETTING BATA DAIN PRIMAX GALAXY 5000 INVERTER HAY JAZAKALLAH
@farhanamin6779 Жыл бұрын
Asalam o Alaikum Bhai net kaise lagana ha is pe bhe detail video share kar dain
@TechnicianBhai Жыл бұрын
Net?
@MuhammadRizwan-uh7tg6 ай бұрын
@@TechnicianBhai wifi kasy connect kr sakty ha or application c details check kr sakty
@TechnicianBhai6 ай бұрын
@@MuhammadRizwan-uh7tg Solar wifi device milti hai daraz se. Different companies hain in main smart solar walon ki best hai.
@maislamicstudio Жыл бұрын
Sir mana 0.37kw ka submurcibal water pump chalana ha us ka kon sa inverter best ho ga 2.2 ya 3.2 Please reply zaror karna bhai hmara gao ma bijli ni ha
@TechnicianBhai Жыл бұрын
2.2kw ya 2.5kw wala bhi chala lae ga inverter...
@Lehndapunjab07865 ай бұрын
Or second ek cheez lazmi bato Jo sb se zrori h k din wapda q used hoti hai
@TechnicianBhai5 ай бұрын
Agr setting USB ho or 13 number setting full per ho to wapda use hoti rahti hai. Or 16 number Bhi SNU or Ue1 ho to bhi wapda use hoti Setting SBU or 13 number 13.8v or 16 number oso kar dae to wapda bilkul use nahi ho gi
@ImadAhmedKhanOfficial6 ай бұрын
Very good video .. thankyou ao much
@kashif_.110 Жыл бұрын
Sir inverter k output AC voltage ko kasy adjust kr skty hn
@TechnicianBhai10 ай бұрын
G video ma btaya hai 220v ya 230v set kar sakte hain
@junaidshah65669 ай бұрын
3200 ke 26 aur 27 number ke setting ka clear kr den in dono mean kia different hae?
@TechnicianBhai9 ай бұрын
Bulk charging or float charging ki setting hai. Search on KZbin k bulk or float charging kya hoti hai.
@CNClearning-9611 ай бұрын
Assalam o alaikum Mere pas pv 2200 hai mene us k sath 100 ampere ki 2 batteries lgai v hain parallel main mujhy us k hisab se setting btaein
@TechnicianBhai11 ай бұрын
Samjho ap ne 200ah ki battery lagai hoi hain to charging ampare 20a set kare baki setting same rahe gi
@sohailaslam296610 ай бұрын
Bahi kasa chal raha
@danishmughal78249 ай бұрын
Brother kesa chal rha apka invt
@TechnicianBhai9 ай бұрын
@@danishmughal7824 not recommend to buy it. Still facing some issue
@UmarFarooq-ym3mb Жыл бұрын
Assalam o alaikum bhai jaan.. your video is really impressive 👏 I have a question bro. I have installed a fronus xeon 2000va and tall tubular battery of 185Ah. What should be the setting 12 and 13?? Meri battery backup bhtt kamm de ri ha.. I think is setting m koi issue ha. My 12no setting is set to 11.0V and 13no setting is 13.5V. Please guide me bro.
@TechnicianBhai Жыл бұрын
12. 11.5v 13. 14v
@UmarFarooq-ym3mb Жыл бұрын
@@TechnicianBhai bhai me ny 14.2V kii ha but Battery phrr b 13.5tk hi Max charge hori ha.. us se ziada ni hori..
@TechnicianBhai Жыл бұрын
@@UmarFarooq-ym3mb solar generation kitni hai or load kitna ha?
@UmarFarooq-ym3mb Жыл бұрын
@@TechnicianBhai 3 545w ki plates installed han or load bhtt ziada nahi ha.. mostly 2,3fans or fridge chalte bss.. kbi kbi sb kuch off krr k 1000watt ki Istri chalaa lete han
@UmarFarooq-ym3mb Жыл бұрын
@@TechnicianBhai battery ko charge hone ka time bhttt milta ha.. raat m b wapda pa charge hoti ha but wo Max 13.5V se ziada charge hi ni hoti.. 13setting Full b kr k dekh li.. uspe b 13.5V tk hi hoti charge bss
@selfearning33037 ай бұрын
Pv3200 bettery k bina chl.skta ha kia
@TechnicianBhai7 ай бұрын
No
@signalbankinternetinformat1962 Жыл бұрын
Fronus Pv2200 inverter han ya rat ko jab soraj garob hota han wapda chor data han jab battery khatam hoti han to par wapda pakrta han Kya masla ho Sakta han Backup ni rhata
@GlobeNobel7 ай бұрын
Aoa fronus PV 3200 pe 1 ton inverter ac chal jaye ga
@TechnicianBhai7 ай бұрын
1.5t bhi chal jae ga
@GlobeNobel7 ай бұрын
@@TechnicianBhai actually hum ne le lia hai lekin Maine abb reviews parhein hain logon ne complains bht zyada lekhi huwi hai . Abhi packing mein hai change hosakta karwa loon ya nhi aur AGR karwaoon toh best company konsi hai
@fromireland5 ай бұрын
No 30 and no 36 setting enable nahi ho Rahi hay. Halankay no.5 setting ko FLd Kya hua hay. Kindly guide karay
@TechnicianBhai5 ай бұрын
05 number ko USE per set kare pahle
@faizanrahil11 ай бұрын
Bhai ye kesa chl rha hai apky pas me lena chahta hu ya is range me koi or acha inverter 60-80k ki range suggest kr dain
@TechnicianBhai11 ай бұрын
Fronus k na lae jo latest models hain. In sb main issues hain... Baki solarmax k achay hain
@muhammadzubairaftab88409 ай бұрын
Assalam o Alaikum Brother, aap ki video bohot informative hai. Mera inverter right after a month smell chor kar off ho gaya. Warranty claim k baad jab usay connect kiya to setting issues aa rahay hai. Mein ne ap ki btaey har baat ko follow kiya. Shaed i m unable to understand amperes . Meri AGS 12 volt 27 plates battery hai jis k amperes ka mujay koi idea nahi. Please guide
@TechnicianBhai9 ай бұрын
Ap 20ampare he rakhe charging current
@bilalkhankhan9928 ай бұрын
Bhai pv2200 ka software new install kia ha inhon ne new setting ki vid bny ab
@khurramshahzad91367 ай бұрын
Mere pass pv 2200 hy us me ye problem aa rahi hy k jb soler per chal raha hota hy to wifi router net band ker dyta hy computer or mobile hang hona shuro ho jaty hain. Lakin jese hy soler ka braker band kerty hain chahe battery per jain ya Wapda per sb normal ho jata hy .. please guide ker dain k kya problem hy
@TechnicianBhai7 ай бұрын
Software 007 updated hai? Agr software updated hai to solar wala breaker remove kar k solar wire direct inverter main laga dae. Agr issue resolve ho jae to samjho solar wala breaker kharab hai.
@ranafaisal94308 ай бұрын
Aoa bhai , bhai fronus pv 2200 lagaya hua hy , din time jb solar on hota hy to display pr sath wapda ka tower matlb k solar or wapda sy b bijli ly raha hota hy , jb k dhoop b boht hoti hy , or is liye hamy dp box sy wapda ka brecker off krna parta hy . Tb ja kr solar sy only bijli leta hy warna solar or wapda 2no mix chlta hy , plz bhai is k liye setting btana , is maslay k liye ???
@TechnicianBhai8 ай бұрын
Ap yeh setting kar dae 01. SBU or SUB 12. 12v 13. 13.4v 16. OSO or SNU
@TechnicianBhai8 ай бұрын
Or software updated 007 ya 006 hona chaie. Agr update nahi to woh update karwa lae uss per ma ne video bnai hoi hai
@ranafaisal94308 ай бұрын
G Bhai software update WALA hi Lia hy abi 3 din huay hen new Lia hy
@ranafaisal94308 ай бұрын
Or Bhai is par fridge Chal jay gi , abi check Ni Ki chla kr?
@TechnicianBhai8 ай бұрын
@@ranafaisal9430 g chal jae gi.
@ShahzadWahla-k7f10 ай бұрын
Sir mery pass 200 watt waly 2 panel hy kia pv 3200 per lag jaye gy
@TechnicianBhai10 ай бұрын
Yes 30v pv se solar generation Start kar deta ha yeh
@ShahzadWahla-k7f10 ай бұрын
@@TechnicianBhai sir mery 12 v waly 2 panel hy dono ko sireies me kar ky 24 v ho gy kia ye mppt ko on kar dy ga
@TechnicianBhai10 ай бұрын
@@ShahzadWahla-k7f nahi kam se kam 18v k hote hain 200watt wale open circuit 21v tak agar 18 hn to 36v bane gae 2 panels k. Or lagane series main hain
@ShahzadWahla-k7f10 ай бұрын
@@TechnicianBhai me ny parlal me lagye hy pwn controller ky sath os per taiz sun light me 13.9 v or 8 amp tk show karta hy
@TechnicianBhai10 ай бұрын
@@ShahzadWahla-k7f ok pwm k sath parallel ma he lagte hain. But pv3200 ma series ma lage gae
@adilbilal6007 Жыл бұрын
Assalam o alaikum bhai aap ne jo 11 number kj setting btai hai.. Agar bnda Inverter ko as a U.P.S istimal karw to A.C ka 1 ampere D.C k 20.24 ampere j brarabar hota hai.. To phir 11 number ki setting main agr ampere 20 pr set jr dain ge to inverter khrab nahin ho jai ga??
@TechnicianBhai Жыл бұрын
Nahi 11 number main jo 2 ampare hain woh DC k 2 ampare hn gae battery ki charging k lie.
Great bro, suna he fronus fsd service centre p both versions 006 & 007 avail hein. Kon sa better he 006 ya 007 ?
@TechnicianBhai Жыл бұрын
006
@zillagaming8716 Жыл бұрын
Sir apni batya ke sbu pr batry bacuo kam degi who q bhla?
@TechnicianBhai Жыл бұрын
Bcz SBU main sab se pahle solar se load chalae ga agr solar ki power kam ho gi to phr battery per load shift ho jae ga or jab battery setting 12 k voltage tak pohche gi to uss k bad apka load wapda per shift kare ga
@WildLensVlogs Жыл бұрын
Dear, boht achi informative video thi aur ap pv 2200 ke performances se satisfied hain ager satisfied hain btna please muje lena hai aur ap ne in k sath kitne watt k kitne panel attach keye hain. Mere pass abi 460 k do panel hain jo veyron I pr parallel leg hoe hain or wo 400/450 watts se ziada generate nhi krta peak time me or me wo series me lega b nhi sakta q k mppt 80 volt se ziadaa support nhi krta..
@TechnicianBhai Жыл бұрын
Pv 2200 or pv 3200 main updated software k bad bhi issues hain. Agr new lene ka soach rahe ho to na lo. Company kah rahi hai eska dobara software aye ga. Ab pata nahi kab ata hai or yeh bhi nahi pata software update k bad dobara masle resolve hn gae ya nahi.. Or Main ne 6 panel lagae howe hain 150watt k 600watt dete hain.. taqreebn.
@WildLensVlogs Жыл бұрын
@TechnicianBhai dear phir dorsa koi bether option hai 12 volt me ager pv 2200 me after updates koi bara issue nhi to phir sehe ager abi b koi bara issue hai Jo disturb kr raha frequently to phir nhi leta dear ager is bat nhi to ap kahe to le lune q k mere abi jo inventor hai na wo change krta kuch ziada capacity wala k sath . thanks for the positive reply.
@TechnicianBhai Жыл бұрын
@@WildLensVlogs Solar max, crown k achay hain inverter
@TechnicianBhai Жыл бұрын
@@WildLensVlogs pv2200 main software update k bad battery proper charge nahi karta to battery backup kam milta hai.
@alihasnain8514 Жыл бұрын
Pv 3200 ka meny 0006 wala krwaya hai software...is me bhi koi issue hai?
@ismailismail-sb6ep9 ай бұрын
Bhai ye setting sheed kaha se download ho gi ap jo video mai dikha rahy
@TechnicianBhai9 ай бұрын
Google per search kare pv2200 manual
@ismailismail-sb6ep9 ай бұрын
@@TechnicianBhai nai mill raha
@ismailismail-sb6ep9 ай бұрын
Koi link share kar do
@TechnicianBhai9 ай бұрын
@@ismailismail-sb6ep ess main pdf download per click kare gae to ho jae gi download www.anerngroup.com/products/2000w-3200w-pure-sine-wave-solar-hybrid-inverter/
@URSHOPINGSTORE6 ай бұрын
Bai mere pas pv 3200 h 007 bai solar pe battery ko thk charging kerta h lakin jb wapda se charging kerta hon 2 mint tk wapda se charging kerta h us k bad full show kerne lgta h lakin battery full nhi hoti plz help me
@TechnicianBhai6 ай бұрын
Service center walon ko complain kare or btae k 007 software main bhi issues hain tab shaid woh new software jari kare
@URSHOPINGSTORE6 ай бұрын
Shukriya bai
@URSHOPINGSTORE6 ай бұрын
Bai ab mesla ye a rha h k solar pr battery charge to rahi hai lakin full nai ho rahi na hum battery use kr rhe h phr b full nahi ho rahi 13 din se battery charge ho rahi h
@muhammadafzal89666 ай бұрын
Bai mere wapda or solr use Hota Ha solr Hona chiye
@URSHOPINGSTORE6 ай бұрын
@@muhammadafzal8966 Battery full charge ho rahi kia
@zafaryaseen9139 Жыл бұрын
Bhai mere pass 550watt k 2 panel he masla ye arha he k pv volt 30 volt pe stuck hojati sir sir solar SE 300watt SE zeada nhe jate eska kia Hal he
@TechnicianBhai Жыл бұрын
Yeh issue old software ma tha. Ap service center ja kar software update karwa lae pv2200 ka
@pakemperor397910 ай бұрын
Mere pass 1100 watt ka pc h and 3 4 led bulb chl rhy hoty hain to inverter light jaty sth beep shuru krdeta h and jese e light jati h battery k 2 cell khd e girjaty hain , kia issue hoga ?? Battery to ni khrb? Agr ap lahore sy hain to chkr lga lein I'll pay you
@pakemperor397910 ай бұрын
Mene 2 batteries lgai hain 155 amp hour ki osaka p210s Pehly 1 thi tb b beep krta tha Lekin ab 2 hain to ab kr rha h! Light jaty sth e...kindly guide krdein
@pakemperor397910 ай бұрын
And 3 solar pannel 275watt double sided parallel mein lgai hui hain
@TechnicianBhai10 ай бұрын
@@pakemperor3979 software update karwa lia hai 007 ? Old software battery ko proper charge nahi karta tha. Uss per ma ne video bnai hai. Dosra setting 18 ko off kar dae beep sound band ho jae ga
@TechnicianBhai10 ай бұрын
@@pakemperor3979 parallel main mat lagae sare panel series main lagae mppt range tab ja kar pori hoti hai
@pakemperor397910 ай бұрын
@@TechnicianBhai sorry sorry series mein e lgae hain solar panels
@atteeqkhan1238 Жыл бұрын
Bhai mery pass pv3200 invertor ha aur es py sollar charging kar Raha ha but jab bi load dala jaye to charging chor deta ha ab konsi setting thek karni ha
@TechnicianBhai Жыл бұрын
Software update karwa lia hai?
@atteeqkhan1238 Жыл бұрын
@@TechnicianBhai konsa ya ABI Kuch month phly leya tha ABI thek chalta tha phir fault howa to company NY reapir kya ab ya issue araha ha shyed setting Ka masla ha to konsy number ki setting thek kary
@waleedbaloch852 Жыл бұрын
Fronus 1.6 kw inverter installed. Jab sa tubler tx 1800 battery lagae ha inverter ka fan auto off nahe hota. Age load run na ho phir bhe fan off nahe hota. Please setting bta den
@TechnicianBhai Жыл бұрын
Ess k fan 100watt se ziada load per chalte he rahte hain
@waleedbaloch852 Жыл бұрын
@@TechnicianBhai brother 100 watt ka load bhe na ho phir bhe fan on rahta ha. Jb sa tubler battery lagae ha jb sa fan on rahta ha phla asa nahe tha
@TechnicianBhai Жыл бұрын
@@waleedbaloch852 nahi yeh battery ka issue nahi hai.
@waleedbaloch852 Жыл бұрын
@@TechnicianBhai mjha lgta ha ka charging hona ki wja sa inverter fan on krta ha. Floating charging pr bhe fan on rahta ha
@TechnicianBhai Жыл бұрын
@@waleedbaloch852 woh to lazmi bat hai agr wapda se charging kare gae to fan on he rahe gae. Oso kar dae to rat ko fan band ho sakte agr 100watt se load kam howa to
@waleedbaloch852 Жыл бұрын
1.6 kw xeon fronus ka sath 550 ka 4 panels laga kr. 1 ton a.c chala skta ha?
@TechnicianBhai Жыл бұрын
Yes but ac inverter hona chaie
@waleedbaloch852 Жыл бұрын
@@TechnicianBhai thanks your reply ❤️
@PakistanConnect9 ай бұрын
Bhai inverter mei fan ki awaz band ho skti hai Kia ?
@TechnicianBhai9 ай бұрын
No... But agar charging setting oso per ho to kuch time bad band ho jati h
@PakistanConnect9 ай бұрын
@@TechnicianBhaimein pv2200 use kr rha hon 2 panel 585 watt k lagay hwy hein aur electricity 300 se 350 v tk banti hai..aur sham 4 k baad kaam hojati hai Kia yeh Sahi hai?
@TechnicianBhai9 ай бұрын
@@PakistanConnect software 007 hai updated ? Or mujhe lagta hai ap ne solar panels parallel lagae howe hain. Agar parallel hain to unko series main kar dae production 700watt tak chali jae gi
@PakistanConnect9 ай бұрын
@@TechnicianBhai software 007 hai ab yeh series mei kesy lagein gy
@TechnicianBhai9 ай бұрын
@@PakistanConnect check google connection of 2 solar panels in series and see images
@faizanrahil11 ай бұрын
Isky sath wifi device lag jati hai mobile se monitor krny k liye
@TechnicianBhai11 ай бұрын
Yes leg jati hai
@Gamermunda Жыл бұрын
پی وی 3200 کی 30 نمبر سیٹنگ آن ہی رکھنی چاہیے ؟ EEN
@TechnicianBhai Жыл бұрын
Yes
@FaiqFightingAutism7 ай бұрын
How to control the sound of PV 2200 too much noise please help me to resolve
@hamzatalib60347 ай бұрын
A.o.A Bhai pv 3200 pe 1 ton inverter AC on krta hu to 02 ka error deta he heating ka iska kya hal he ? Halan k is k ilawa fridge or iron ka load to sai utha leta he solar pe lekin sirf Ac on kru to heating ka error he iska hal bta den plz
@TechnicianBhai7 ай бұрын
Solar panels kitne lagae howe kitne watt k or series hain ya parallel
@hamzatalib60347 ай бұрын
@@TechnicianBhai 6 panels lagy hen series me Jinko k Last year 545w k 2 thy or ab 555w k 4 add kiye hen
@TechnicianBhai7 ай бұрын
@@hamzatalib6034 Dust filter saf karte hain? Or inverter kya ziada heat wali jaga per to nahi laga howa?
@TechnicianBhai7 ай бұрын
@@hamzatalib6034 Software updated 007 ha?
@hamzatalib60347 ай бұрын
@@TechnicianBhai g filter bhi saaf kiye hen phr b dopehr k waqt heating ka error ata he jab k inverter indoor hi laga he ventillation bhi he Software iska 001 he
@imranemmi02225 ай бұрын
Love u bro❤
@maharsaeedsial9 ай бұрын
Bhai mere inverter ma ak msla a rha hai jab load band output ka to solar se current ni ata mtlb solar bettry charge ni.krta jab load on kren to tab bettry charging hoti hai
@TechnicianBhai9 ай бұрын
Yeh issues taqreebn sb ma aa raha hai specially 006 software main bhi hai
@shahidsheikh52493 ай бұрын
Please, Setting of Maxpower sunglow mv 2 hybrid off grid, four tubular batteries in series..
@Lehndapunjab07865 ай бұрын
Mtlab k din me to solar used ho but din m bhi sirf solar se charging ho Rahi hoti used wapda hi hoti hai
@notyour.x48339 ай бұрын
Bro pv2200 ko check krny k liye wapda wali line off kr k on ki ab wo just battery sy load ly rha ha wapda bypass show ni krwa rha kindly iska koi solution bta dein
@TechnicianBhai9 ай бұрын
Setting main agar UPS mode select hai to usko APL kar k dakhe.
@AhmedAli-du6nr6 ай бұрын
sir g pv3200 hai is main eroor 03 ata hai our band ho jata hai
@TechnicianBhai6 ай бұрын
Service center lae jae
@AbdulRauf-mc1rs8 ай бұрын
Bhai Jan red lait mosalsal chall rahi hy or inverter Kam Bhai Nahi Kar Raha Hy Kia Kia jay
@AbdulRauf-mc1rs8 ай бұрын
Ansar pliz
@TechnicianBhai8 ай бұрын
@@AbdulRauf-mc1rs Battery ko aik dafa hatta kar dobara lagae. Agr phr b on na ho to battery ko charge kare or phr inverter k sath lagae
@AbdulRauf-mc1rs8 ай бұрын
On to HOTA Hy sacred par batri full show b karta Hy red lait jali rehti Hy input output zero sho karta hy
@ranafaisal94308 ай бұрын
Bhai lazmi is maslay k liye setting btana plz ???
@aamiransari173411 ай бұрын
Kya mujhe ap ye settings chart send Kar sakte he
@mmuzamil4097 Жыл бұрын
Bhai load shedding boht ziada hoti he 24h me 2h bijli hoti he is waja se bettry belkul charge ni hoti he.. 150 bettery he.. Kia karo esa k solar se battery ko full charge mile.
@TechnicianBhai Жыл бұрын
1 number setting USB or 16 number setting SNU kar dae. Or sath 11 number setting 20amp kar dae. Abhi sardian hain wapda use kare jab solar ki power ziada ho jae tab pahle wali setting sbu ya sol kar dae