Nameplate details of Power Transformer | Explained | TheElectricalGuy

  Рет қаралды 103,872

Gaurav J - TheElectricalGuy

Gaurav J - TheElectricalGuy

Күн бұрын

Пікірлер: 93
@KABIRUSULEH
@KABIRUSULEH 3 ай бұрын
Mr. Gaurav you are amazing. Kudos to you for this wonderful explanation.
@GauravJ
@GauravJ 3 ай бұрын
thanks
@balasubramanig634
@balasubramanig634 3 жыл бұрын
This temperature is measured in oil due to heating of windings in oil, by temperature gauge .if temperature exceeds it shutsdown tranifomer by connected to ACB or OCB. I thank super explanation . Max 70 degree C.
@prabhakaran20ten
@prabhakaran20ten 4 жыл бұрын
Thanks for detailed explanation, Electrical Engineer rocks 👌
@manig3101
@manig3101 4 жыл бұрын
You're explain very clearly and very useful .Thanks for vidos
@sethtaylor5938
@sethtaylor5938 Жыл бұрын
MVA highest rating is with Fans on. Heat run is usually higher depending on the utility. Then there’s the emergency rating, higher yet. That number is not on the nameplate.
@billdavis606
@billdavis606 5 жыл бұрын
The video states Lv leads Hv by 30 degrees, or Hv lags by 330, in this case both numbers should be the same. If it states Lv leads Hv, and then Hv leads Lv, the numbers would be different as indicated.
@sebastianbugade3521
@sebastianbugade3521 Жыл бұрын
He should make correction here
@sebastianbugade3521
@sebastianbugade3521 Жыл бұрын
Very Correct
@eugeneleroux1842
@eugeneleroux1842 3 жыл бұрын
Thank you for a very informative and use full presentation.
@GauravJ
@GauravJ 3 жыл бұрын
Glad it was helpful ☺️ do also check out other videos on my channel 😊
@technovisionacademy
@technovisionacademy 3 жыл бұрын
Your work is really appreciated...👍👍👍
@GauravJ
@GauravJ 3 жыл бұрын
Thanks 😊 Do share and subscribe 😊
@Deepakranjan555
@Deepakranjan555 3 жыл бұрын
Aur bhi electrical video daliye..
@tb.casenjo2680
@tb.casenjo2680 2 жыл бұрын
Hello Gaurav, I would like to see the "turning sense" to clarify tha phase shift in both cases (HV lags or LV leads) the angle is only 30º
@pitamchettri3480
@pitamchettri3480 5 жыл бұрын
sir please make a video on why electron is negatively charged and what actually is charge?
@FULLMOON36528
@FULLMOON36528 5 жыл бұрын
beautiful animation...keep it up n thnaks for the beautiful voice...
@badshahengineeringvlogs9718
@badshahengineeringvlogs9718 Жыл бұрын
Sir please explain all test of power transformer on practical manners. 🙏 we wait
@md.shahjahanali4285
@md.shahjahanali4285 4 жыл бұрын
at 3:03 "LV leads HV by 30 degs or HV lags LV by 330 degs" is not correct. It will be "LV leads HV by 30 degs or HV lags LV by 30 degs"
@gajananwakle6670
@gajananwakle6670 3 жыл бұрын
thank you
@amitavmondal5855
@amitavmondal5855 2 жыл бұрын
Sir kindly make a video on average power
@sebastianbugade3521
@sebastianbugade3521 Жыл бұрын
Gaurav please reply comment of Bill Davis to clear the atmosphere
@eng.omareyadaljorani9954
@eng.omareyadaljorani9954 4 жыл бұрын
Thank you so much Sir, Why transformer name plate made of stainless steel?
@randomjack477
@randomjack477 7 ай бұрын
Thankyou. Is the LV 1669 amps per phase or the total of 3 phase amps?
@muqtardm
@muqtardm 5 жыл бұрын
Very helpful thanks lot.
@osamazahid715
@osamazahid715 5 жыл бұрын
such a great video, I like it too much.
@Deepakranjan555
@Deepakranjan555 3 жыл бұрын
Beautiful
@horizonrohit
@horizonrohit 4 жыл бұрын
Very good
@MrMadhumithan
@MrMadhumithan 6 жыл бұрын
Hi bro your videos are super
@patakotisrinivas1918
@patakotisrinivas1918 5 жыл бұрын
Thanks sir...nice explaination...
@kilumumahesh935
@kilumumahesh935 6 жыл бұрын
Useful data bro ...
@rameshtripathy5978
@rameshtripathy5978 5 жыл бұрын
Good explanation !
@jmorbasayan1901
@jmorbasayan1901 4 ай бұрын
May I know what is the function of OLTC on power transformer?
@saberkangalio9576
@saberkangalio9576 3 жыл бұрын
Fantastic
@GauravJ
@GauravJ 3 жыл бұрын
Thanks. Do share and subscribe to my channel ☺️✌🏻✌🏻
@Santosh9720103812
@Santosh9720103812 5 жыл бұрын
the last point about temperature is not ok bro(ambient temp etc)..please check and provide right info..i like your tutoring style though ...god bless you ..
@hareshrajyaguru8094
@hareshrajyaguru8094 2 жыл бұрын
You should clearly mention that the phase differance will be only between the LINE VOLTAGES of the Primary and Secondary windings. PHASE VOLTAGES of the Primary and Secondary Windings are always in Phase.
@abebehaile8985
@abebehaile8985 4 жыл бұрын
tanks for explanation
@premtours
@premtours 3 жыл бұрын
Nice
@Deepak_Kumar1993_
@Deepak_Kumar1993_ Жыл бұрын
Dyn11 is power transformer?
@rengaramanujan
@rengaramanujan 5 жыл бұрын
Dyn11 is -30 deg its wrongly mentioned in nameplate
@jeraldabasolo376
@jeraldabasolo376 2 жыл бұрын
nice bidyo sir
@ruan2587
@ruan2587 6 жыл бұрын
Thank you sir.
@healingmeditation5970
@healingmeditation5970 4 ай бұрын
I THINK FOR Dyn11 HV winding i.e (hour end) should be at 11 and LV winding(minute end) should be at 12 then we can say HV leads LV by 30 deg
@curiousguy9544
@curiousguy9544 5 жыл бұрын
Thanks. The maximum temperature rise at ambient 50c is given as 50/55. So in running condition the acceptable max temperature is 50/55 or 100/110?
@ssh6943
@ssh6943 4 жыл бұрын
Hi ,can you please explain how three phase AC supply is generated from Alternator and Inverter having phase difference 120°.
@GauravJ
@GauravJ 4 жыл бұрын
Sure. I’ll try to post a video on it.
@sudhakarm4394
@sudhakarm4394 5 жыл бұрын
Quality maitained bro
@pankilshingala9309
@pankilshingala9309 6 жыл бұрын
In case of LV winding Why lightning impulse voltage is not applicable?
@asimjan438
@asimjan438 5 жыл бұрын
Great...Thanks...but every one is skipping to explain the percentage impedance....
@substationtestingandcommis3452
@substationtestingandcommis3452 2 жыл бұрын
It is % of rated primary voltage required to produce rated current when secondary winding is short circuited.
@Anups_art_energy7
@Anups_art_energy7 5 жыл бұрын
Brother could u explain an vector group YNaOd1
@timhumphries479
@timhumphries479 5 жыл бұрын
One question, with % impedance for different taps, if you wanted to find the ohmic value, would you use the voltage at that specific tap as your kVbase or do you use the nominal kVbase for all? Thank you
@visheshgarg4642
@visheshgarg4642 2 жыл бұрын
Sir appki clock mai fark nhi hai ,minute hand lamba hota hai or hour hand chota hota hai , or jab 11 bjte hai toh hour (small hand ) 11 pr hoga or minute hand hai (long hand wo 12 pr hoga ,pr aapne toh ulta liya hai ...confused
@mdabuzafar6883
@mdabuzafar6883 2 жыл бұрын
Pls explain nameplate details of a motor
@parthzalavadiya2131
@parthzalavadiya2131 5 жыл бұрын
Sir In induction motor sometimes efficiency is not indicate why ??
@neelbanerjee3086
@neelbanerjee3086 5 жыл бұрын
details video about transformer vector groping. please i need to understand correctly.
@bojhporiintertenmentsong8501
@bojhporiintertenmentsong8501 6 жыл бұрын
Nice #desielectrical
@hardikrana2673
@hardikrana2673 5 жыл бұрын
HV vtg is of 33kv then why we are using transformer of 1250KVA? We can use lower one?
@sudheersubairkutty1633
@sudheersubairkutty1633 3 жыл бұрын
You mentioned cooling of transformers with oil forced water forced (OFWF), could you please specify which rating of transformers (MVA) will use these type of cooling.
@substationtestingandcommis3452
@substationtestingandcommis3452 2 жыл бұрын
100MVA & above
@amarnathmishra1461
@amarnathmishra1461 4 жыл бұрын
Good video .How do you define impedance volts ?
@substationtestingandcommis3452
@substationtestingandcommis3452 2 жыл бұрын
% of primary voltage applied that will produce rated current when secondary winding is short circuited.
@amarnathmishra1461
@amarnathmishra1461 2 жыл бұрын
@@substationtestingandcommis3452 That's right.% of rated primary voltage required to establish rated current as secondary is short circuited
@7akm123
@7akm123 5 жыл бұрын
Other transformers have 2 or 3 types of cooling mention as ( onan / onaf / ofaf ) why ? Is that for each phase or primary/secondary winding ?
@zaheerrao1150
@zaheerrao1150 5 жыл бұрын
Hakem M over all transformer because all windings are dipped in the same oil tank ... where fans are provided outside the tank where hot oil move in the ducts
@Hitlerstopjew
@Hitlerstopjew 4 жыл бұрын
It is for different stages of the cooling process. The hotter the transformer is, the more stages of cooling will be used. When the transformer is cool it will use only natural convection, then it will add forced convection through the use of cooling fans as the temperature rises.
@KENFEDOR22
@KENFEDOR22 4 жыл бұрын
@@Hitlerstopjew good explanation! Further, allowing the transformer temperature to rise results in more output. Large 3 phase oil immersed XFMRs will typically be ONAN/ONAF/ONAF with corresponding three MVA stages. A good example: 30/40/50 MVA at 50C rise means at 30 MVA, no fans running, just natural cooling, at 40 MVA, 1/2 the fan bank is running (forced cooling), at 50 MVA, all fans running. A fourth MVA can be added to denote an increased MVA at 65 C (in this case, 56 MVA). The rule of thumb is each MVA step raises 33% (from 30 to 40 MVA), while the 65C jump from 50% is 12% (from 50 to 56).
@KhalidMehmood-cm5ri
@KhalidMehmood-cm5ri 4 жыл бұрын
Brother there are 4 type of coolings systems most prevalent in power transformers. Onan Onaf Ofan Ofaf First is natural Second is air forced Third is oil forced Forth is oil forced and air forced. There are leading and lagging thermostates setting on different temperatures they contineous watch the temperature behaviour of power transformer in normal and peak hours and maneuver the through above mentioned four systems as required time to time. (Khalid Mahmood pakistani power xfmr specialist)
@7akm123
@7akm123 4 жыл бұрын
Thanks to all comments you help me 🙏
@praveenkp5463
@praveenkp5463 5 жыл бұрын
Why primary winding represents 3 split rectangles?
@jamilajamila3658
@jamilajamila3658 3 жыл бұрын
What does mean by 10KVA rating of the transformer? Is it transformer input or output? Please clear me.
@substationtestingandcommis3452
@substationtestingandcommis3452 2 жыл бұрын
it means 10KVA load can be supplied by this TF.
@hasanmusanadaf9686
@hasanmusanadaf9686 5 жыл бұрын
OLTC which side it's connected for HV side or LV side.
@KhalidMehmood-cm5ri
@KhalidMehmood-cm5ri 4 жыл бұрын
If step down power tranformer then OLTC HV side if Generator xfmr then lv side but not necessary oltc may be manual.
@jitendrapatil7869
@jitendrapatil7869 5 жыл бұрын
Why tapping are provided on HV winding? Why not on LV winding?
@Santosh9720103812
@Santosh9720103812 5 жыл бұрын
some countries have tappings on LV too..it only depends on usage as mostly LV is secondary in india.
@anoopraj8346
@anoopraj8346 5 жыл бұрын
On hv windings current is low as per transformation equation.So tap changing is preferred on hv.On lv current flow is higher and tapchangings may lead to sparkover and resulting winding destruction
@satyarout9377
@satyarout9377 5 жыл бұрын
Sir why transformer primary & secondary power ratting are different Like 30mva/35mva
@zaheerrao1150
@zaheerrao1150 5 жыл бұрын
Satya Rout it’s not p & s winding ratings.... its actually ratings with out cooling & with cooling
@karthikreddy-hl9dd
@karthikreddy-hl9dd 5 жыл бұрын
What does untanking mass and transportation mass means?
@KENFEDOR22
@KENFEDOR22 4 жыл бұрын
For larger oil immersed transformers, "untanking" mass refers to the core and coil assembly (or the active part) weight/mass or what is actually untanked by a crane. Some larger transformers (20-200 MVA) can have the tank top plate as part of the core/coil assembly. "Transportation" mass refers to the actual weight as it is transported, the tank with the active part inside. For larger transformers, all the accessories that can be removed are to make the transport weight lower (lower cost). Bushings, radiators, fans, even control cabinets are removed for transport. On the largest transformers (think high voltage transmission systems), oil is drained prior to transport to bring transport weight down even lower. Crossing bridges and culverts gets expensive as weight goes up.
@chandrashekharratnakarjosh8500
@chandrashekharratnakarjosh8500 6 жыл бұрын
Hon.Best.
@chebrolupavankumar899
@chebrolupavankumar899 5 жыл бұрын
Pls explain tapping theory
@Happy-cz8ft
@Happy-cz8ft Жыл бұрын
isn't 11 min 66 deg? ((11/60)*360)
@alimanaal-atefi3622
@alimanaal-atefi3622 7 ай бұрын
🙋‍♂️💟🙋‍♀️
@donberg01
@donberg01 4 жыл бұрын
Question: why do engineers use % of Z & not Ohms?
@rsg5850
@rsg5850 5 жыл бұрын
DYnAllavan!
@kashikhan518
@kashikhan518 2 жыл бұрын
⁰0
@moumitagorain3492
@moumitagorain3492 Жыл бұрын
Amazing
@surendrakverma555
@surendrakverma555 4 жыл бұрын
Very good
Nameplate Details of Inductive Voltage Transformer (IVT) | Explained | TheElectricalGuy
12:02
Nameplate Details of Current Transformer | Explained | TheElectricalGuy
11:16
Gaurav J - TheElectricalGuy
Рет қаралды 53 М.
Кто круче, как думаешь?
00:44
МЯТНАЯ ФАНТА
Рет қаралды 5 МЛН
СКОЛЬКО ПАЛЬЦЕВ ТУТ?
00:16
Masomka
Рет қаралды 3,1 МЛН
How To Choose Mac N Cheese Date Night.. 🧀
00:58
Jojo Sim
Рет қаралды 84 МЛН
Power & Distribution Transformer | What are the differences | TheElectricalGuy
10:30
Gaurav J - TheElectricalGuy
Рет қаралды 15 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 1,6 МЛН
HVAC vs HVDC | What is the difference | TheElectricalGuy
14:34
Gaurav J - TheElectricalGuy
Рет қаралды 46 М.
Why there is no Neutral in Transmission Lines?  Explained | TheElectricalGuy
8:46
Gaurav J - TheElectricalGuy
Рет қаралды 258 М.
Percent Impedance of a Transformer
6:44
Zack Hartle
Рет қаралды 34 М.
Lecture 1: Introduction to Power Electronics
43:22
MIT OpenCourseWare
Рет қаралды 825 М.
How 3 Phase Transformers Work - why we need them
24:24
The Engineering Mindset
Рет қаралды 981 М.
What does "impedance matching" actually look like? (electricity waves)
17:08
Why Circuit Breakers DON'T Protect People (electric shocks)
18:23
The Engineering Mindset
Рет қаралды 1,4 МЛН
Кто круче, как думаешь?
00:44
МЯТНАЯ ФАНТА
Рет қаралды 5 МЛН