Venturimeter kya hota hai || What is Venturimeter || venturimeter derivation || Gear Institute

  Рет қаралды 24,054

Gear Institute Mechanical Engineering Videos

Жыл бұрын

#sscje #mechanical #gearinstitute
Click here to download our app
edumartin.page.link/jLFr
Join telegram channel
t.me/gearinstitute
JE की तयारी के लिए App Download करें
edumartin.page.link/jLFr
ALL IN 1 AE/JE EXAM LIVE CLASSES (TECHNICAL +NON TECHNICAL)
bit.ly/452qVRR
ALL IN 1 AE/JE EXAM LIVE CLASSES (TECHNICAL ONLY)
bit.ly/3Rp4ykf
SSC JE RECORDINGS (2YEAR VALIDITY).
bit.ly/3CSOuzH
SSC JE RECORDINGS (1YEAR VALDITY)
bit.ly/3W9LVjv
Mechanical MCQ Book written by Er.Harvinder Singh
Order your copy click here
bit.ly/MCQBOOK
Join our whats app channel
whatsapp.com/channel/0029VaCPbFbE50Uee2zw6944
Strength of material Full Syllabus
bit.ly/38jyEBX
Fluid Mechanics Full Syllabus
bit.ly/3uNsG3z
Theory of machine Full Syllabus
bit.ly/3xRPQJk
Thermodynamics Full Syllabus
bit.ly/3k7lXws
Material Science full syllabus
bit.ly/38pU5Bf
Machine Design Full Syllabus
bit.ly/3k7lr1u
Automobile Engineering Full Syllabus
bit.ly/3wMMm8S
Refrigeration and air conditioning Full Syllabus
bit.ly/3Q2tHyy
Power plant engineering
bit.ly/3kGoj9v
Workshop Technology
bit.ly/3QGsNIo
Industrial Engineering
bit.ly/3vvyyjq
bit.ly/3vvyyjq
bit.ly/3xUxdCY
Working of Venturimeter - Construction, Principle with Diagram
Venturimeter is a device that is used to measure the rate of flow of fluid through a pipe. This device is based on the principle of Bernoulli’s Equation. Venturimeter is named after G.B Venturi who developed the principle of venturimeter in 1797 but this principle comes into consideration with the help of C. Herschel who developed the first venturimeterin 1887.
Main parts of venturimeter :-
1. Covering part : It is the part of the venturimeter where the fluid converges .
2. Throat : It is the portion that lies in between the converging and diverging part of venturi. In the throat portion the cross section is much less than converging and diverging portion. When the reaches the throat, its velocity increases and pressure decreases.
3. Diverging part : It is the part of the venturimeter where the fluid gets diverges and the cross-section area increases.
Construction :
As stated above it has three parts converging part, throat and diverging part. These three parts are arranged in systematic order.
First one is inlet section or converging section. It is the region where the cross section emerges into conical shape for the connectivity with the throat region. . In this part cross section area decreases from beginning to ending. This section is connected to inlet pipe on one end and cylindrical throat on the other end. The angle of convergence is generally 20-22 degrees .
Second one is cylindrical throat .It is the middle part of the venturimeter. It is the cylindrical pipe in venturimeter through which the fluid passes after converging in the convergent section. Throat has generally a diameter of throat is half the diameter of pipe. The diameter of the throat remains same through out its length.
Working :-
Expression for the rate of flow through Venturimeter
Consider a venturimeter is fitted in a horizontal pipe through which fluid ( water ) is flowing as shown in figure below.
Let a1 = cross-section area of inlet pipe
d1= diameter of inlet pipe
v1 = velocity at inlet pipe
p1 = pressure at inlet pipe
also,
a2 = cross-section area of throat
d2= diameter of throat
v2 = velocity at throat
p2 = pressure at inlet throat
Venturimeter is a device that is used to measure the rate of flow of fluid through a pipe. This device is based on the principle of Bernoulli's Equation. Venturimeter is named after G.B Venturi who developed the principle of venturimeter in 1797 but this principle comes into consideration with the help of C
Venturimeter kya hota hai
Venturimeter in hindi
Venturimeter derivation
Venturimeter derivation in hindi
Venturimeter derive
derive Venturimeter
Venturimeter
What is Venturimeter
what is Venturimeter in hindi
Venturimeter
Venturimeter derivation in hindi || Venturimeter derivation class 11 || venturimeter fluid mechanics
venturi meter,mechanical engineering,venturi meter in hindi,flow rate measurement,fluid mechanics,venturimeter derivation,venturimeter derivation class 11,Venturimeter,what is venturimeter,what is venturimeter in hindi,venturi meter derivation class 11,venturi meter derivation,venturimeter fluid mechanics,venturi meter flow measurement,venturi meter flow rate calculation,fluid mechanics lectures,gear institute
Bernoulli's practical in Hindi || Venturimeter practical || venturimeter experiment ||gear institute

Пікірлер: 31
@Sanjeevsirkeyodha
@Sanjeevsirkeyodha Жыл бұрын
Without GEAR INSTITUTE mechanical engineer is not a perfect engineer
@sarfanahamedyamin2368
@sarfanahamedyamin2368 Жыл бұрын
I am studying at diploma in chemical engineering in Bangladesh. This chennel is helpful for me.
@abdulraufmustafavi2937
@abdulraufmustafavi2937 Жыл бұрын
Understood sir
@ujjawalsharma8179
@ujjawalsharma8179 9 ай бұрын
Good explanation sir❤
@gear.institute
@gear.institute 8 ай бұрын
Thanks and keep watching SSC JE की तयारी के लिए App Download करें edumartin.page.link/jLFr
@Bibeksah-e6z
@Bibeksah-e6z Ай бұрын
Tq you so much sir itne achhe se samajhne k liye🙏🙏🙏
@gear.institute
@gear.institute Ай бұрын
Welcome and keep Watching For more videos Download app edumartin.page.link/jLFr
@pradeepmishra270
@pradeepmishra270 10 ай бұрын
Awesome explanation sir
@Sanjeevsirkeyodha
@Sanjeevsirkeyodha Жыл бұрын
@ajaykumargondvlogs3074
@ajaykumargondvlogs3074 Жыл бұрын
Nice sir very help full
@SyedZafarHussainShah
@SyedZafarHussainShah 4 ай бұрын
excellent sir thank you
@gear.institute
@gear.institute 3 ай бұрын
Welcome and Keep watching SSC JE की तयारी के लिए App Download करें edumartin.page.link/jLFr
@anupkumarsarkar5486
@anupkumarsarkar5486 Жыл бұрын
Sir ye to apne ideal fluid ke liye bola , isme to aapne head loss consider nhi Kara . Agar losses ko consider Kara to "Co efficient of discharge or Cd" ayega so formula In terms of Cd hoga i.g Actual dis. (Q)=Cd×A1×A2√2gh / √(A1)^2+(A2)^2. Cd = Actual discharge / theoretical discharge.. The value of Cd for venturimeter is ranges between 0.97 to 0.98
@gear.institute
@gear.institute Жыл бұрын
Vo alag se derivation hogi
@_Nagaraju-cj1hq
@_Nagaraju-cj1hq Жыл бұрын
Verey level
@RohitSharma-vw9ke
@RohitSharma-vw9ke 11 ай бұрын
class me Mja aa gya sir
@gear.institute
@gear.institute 11 ай бұрын
Thanks and keep watching SSC JE की तयारी के लिए App Download करें edumartin.page.link/jLFr
@Skillssypaisa
@Skillssypaisa 6 ай бұрын
Very nice ❤❤❤
@Alok.singh-
@Alok.singh- 10 ай бұрын
throat par P=F/A apply karenge to throat par pressure badhegi n
@sourabhYadav-t6l
@sourabhYadav-t6l 11 ай бұрын
Sir me bhi aaya hu class me
@Dr__Creater
@Dr__Creater Жыл бұрын
❤❤❤
@gear.institute
@gear.institute Жыл бұрын
For more videos Download app edumartin.page.link/jLFr
@studychannel3339
@studychannel3339 Жыл бұрын
Sir safety valve per 1 video❤❤
@engrjunaidrasool786
@engrjunaidrasool786 26 күн бұрын
🎉from Pakistan sir
@gear.institute
@gear.institute 25 күн бұрын
Thank you and keep Watching For more videos Download app edumartin.page.link/jLFr
@vivekmalviya3036
@vivekmalviya3036 10 ай бұрын
Thank u sir ❤
@sourabhYadav-t6l
@sourabhYadav-t6l 11 ай бұрын
Sir kha se cheat kiya h aappne
@Manishkumar-ip8pd
@Manishkumar-ip8pd 4 ай бұрын
H hi ni pata laga kahani ka kya fayda
@Shubham_01123
@Shubham_01123 11 ай бұрын
You don't cover any topic in depth , you should tell that why diverging length of venturimeter is long than converging length. Secondly discuss about cavitation in venturimeter
@lalityadav9761
@lalityadav9761 Жыл бұрын
@Manishkumar-ip8pd
@Manishkumar-ip8pd 4 ай бұрын
H hi ni pata laga kahani ka kya fayda
Running With Bigger And Bigger Lunchlys
00:18
MrBeast
Рет қаралды 131 МЛН
Стойкость Фёдора поразила всех!
00:58
МИНУС БАЛЛ
Рет қаралды 6 МЛН
Миллионер | 1 - серия
34:31
Million Show
Рет қаралды 2,5 МЛН
Spongebob ate Michael Jackson 😱 #meme #spongebob #gmod
00:14
Mr. LoLo
Рет қаралды 11 МЛН
Running With Bigger And Bigger Lunchlys
00:18
MrBeast
Рет қаралды 131 МЛН