Geberit SuperTube - a flow-optimised drainage system for high-rise buildings

  Рет қаралды 84,676

Geberit

Geberit

5 жыл бұрын

Thanks to special shaped fittings, the water in the pipes is pressed against the wall. This creates a continuous air column. There is no longer a need for an additional ventilation pipe. This noticeably minimises the space in the installation shaft.
ID: 2218144
If you need technical support, please contact the local technical support team.
Please note: Videos do not replace installation manuals. For installation purposes, please use the respective Geberit installation manuals.
For more information about Geberit visit www.geberit.com
Imprint: www.geberit.com/general/
Disclaimer: www.geberit.com/general/rechts...

Пікірлер: 52
@MD-sg4oc
@MD-sg4oc 2 ай бұрын
No pitch on the horizontal run? Wild
@zactan96
@zactan96 3 жыл бұрын
Hi, I have question regarding plumbing system for cascading/stacking/staggering apartment housing design(e.g. Altair Residences by Safdie Architects). How do the sanitary pipings work? Do they follow the slanting angle of the apartment as well? I'd appreciate it if you could help advice me on this issue.
@SlickManChoux
@SlickManChoux 4 жыл бұрын
It always depends on what is running inside the pipe . Toilet, paper grease, makes it clogged rapidly. There is nothing for life we always need to maintain waist pipe against lime scale. I prefer two waist pipe columns one for toilets the other one for kichens and bathrooms.
@GeberitGroup
@GeberitGroup 4 жыл бұрын
In many countries in Europe (e.g. Switzerland, Germany, Austria) the drainage systems are designed as single stack systems without separating black and grey waste water. Most important to prevent clogging of drainage pipes is correct design and dimensioning of the drainage system, especially when it comes to low-liter flush toilets. With Geberit SuperTube we are offering a hydraulically optimized single stack drainage system that mainly prevents critical over- and under pressure in the drainage system.
@KK-sk3em
@KK-sk3em 4 жыл бұрын
Nice your Video ! How about the fitting?
@Ahmed-oz7vg
@Ahmed-oz7vg 4 жыл бұрын
Cool
@GeberitGroup
@GeberitGroup 4 жыл бұрын
Thanks a lot Ahmed!
@TantheMan1995
@TantheMan1995 3 жыл бұрын
What if there is a blockage, will a Plumber’s snake be able to go through this fitting, seems very obstructive. Also in 40-50 years how would you repair without opening walls or ceilings? I am a Pipelining Technician, rehabilitating deteriorated DWV lines. This “Sovent” would not be linable...
@GeberitGroup
@GeberitGroup 3 жыл бұрын
You can clean it with the standard tools. By the way, one part of the system, the Sovent, is available since 1970 so we have some years of experience with it. :-)
@Hjonvard
@Hjonvard 2 жыл бұрын
When these are plugged and someone lucky enough to fish a cable down the line, does a 4" diameter ball of wipes or rags come back? As a drain cleaning company we are refusing jobs that have this system.
@MrNeptunebob
@MrNeptunebob 3 жыл бұрын
But what if someone makes a really Big American Turd? won't it block the "annular flow"
@GeberitGroup
@GeberitGroup 3 жыл бұрын
We are quite sure it will work
@rodrigogabriel7121
@rodrigogabriel7121 3 жыл бұрын
I am a maintenance guy in a high rise, this system is nothing but problems
@chastie_6821
@chastie_6821 2 жыл бұрын
can you elaborate?
@muzzafarahmad6477
@muzzafarahmad6477 Жыл бұрын
which joint you favor's , gasket joint or cement solvent joint
@muzzafarahmad6477
@muzzafarahmad6477 Жыл бұрын
what type of joint we should use in shaft in high riser building, gasket joint or cement solvent joint?
@GeberitGroup
@GeberitGroup Жыл бұрын
Butt welding joint with HDPE is the best option (pressure tight up to 3 bars)
@benyoucefihab7814
@benyoucefihab7814 5 жыл бұрын
Great idea.
@reinaldoclemente4535
@reinaldoclemente4535 4 жыл бұрын
it is on paper but in reality it is really bad especially in kitchens and laundry lines have the tendency of building soap scum on the walls of the pipes slowing down the flow of the water and clogging the system up i am a Facility Director in a property management company here in Florida and my complex have that system we had to do a monumental project to solved the situation of laundry and kitchen lines getting clogged with devastating catastrophic water damages definitely not recommended for those applications
@DerGriefer
@DerGriefer 3 жыл бұрын
@@reinaldoclemente4535 it’s perfectly calculated, check the papers mate. Maths you know?
@rodrigogabriel7121
@rodrigogabriel7121 2 жыл бұрын
@@DerGriefer it’s perfectly flawed. Very bad idea
@Beniamin6665
@Beniamin6665 3 жыл бұрын
I am a plumber. Ya right...
@cannonplumbinganddrainllc4221
@cannonplumbinganddrainllc4221 3 жыл бұрын
maintenance issues for sure, Texas code wont allow that to be implemented in a building anywhere
@GeberitGroup
@GeberitGroup 3 жыл бұрын
This system is currently not approved for the US as you have a quite different system as we in Europe.
@fiorellasolorzano5203
@fiorellasolorzano5203 2 жыл бұрын
I would like a system to save more than 20% in the vertical drain
@primelpious8316
@primelpious8316 4 жыл бұрын
What about vent pipes
@GeberitGroup
@GeberitGroup 4 жыл бұрын
With Geberit SuperTube you can plan installations without ventpipes - of course all conditions must be fullfilled.
@say_goodnight7342
@say_goodnight7342 4 жыл бұрын
Seeing stuff like this makes me wish Kentucky was a little less strict on their codes, because this would be absolutely illegal. No wet vents are allowed at all. Every fixture has to be individually vented within a span of a couple feet depending on the pipe size.
@GeberitGroup
@GeberitGroup 4 жыл бұрын
We do understand your point and we worked hard on getting all approvals.
@say_goodnight7342
@say_goodnight7342 4 жыл бұрын
@@GeberitGroup lol im not saying I like your system. In fact I believe there are way to many variables, and that the system will never work as good as an individual vent-per-fixture system that our code requires. There are just way to many variables for any wet vent, and to install anything as such is just asking for trouble, and not taking pride in your workmanship. That said, I do believe there is a time a place for your system, such as where you are unable to individually vent a number of fixtures in a remodel, and I believe this, paired with a main vent would do the job. But, it also comes down to cost. I guarantee that the fittings in the system alone cost too much to be a suitable substitute.
@nostradumbass4984
@nostradumbass4984 4 жыл бұрын
@@say_goodnight7342 There is absolutely no reason to vent every fixture. I´m a plumber in Germany, and we have ZERO issues with the way we vent. Geberit is the Nasa/ESA of waste water technology.
@tranceaddiction
@tranceaddiction 4 жыл бұрын
Wow no wet vents at all? That's tough
@DerGriefer
@DerGriefer 3 жыл бұрын
@@say_goodnight7342 in germany and Switzerland it works perfect, experienced man too here. When I see what you build in the US I cry... Geberit very perfectioned the plumbing
@Beniamin6665
@Beniamin6665 3 жыл бұрын
Where in the world are the municipality, Provence and state allowing you to do this....
@GeberitGroup
@GeberitGroup 3 жыл бұрын
SuperTube is approved and working :-)
@Beniamin6665
@Beniamin6665 3 жыл бұрын
Where... What building. Show me proof.
@Beniamin6665
@Beniamin6665 3 жыл бұрын
@@GeberitGroup Where are you approved
@GeberitGroup
@GeberitGroup 3 жыл бұрын
@@Beniamin6665 kzbin.info/www/bejne/m6C4pZiwm9-aq8k
@GeberitGroup
@GeberitGroup 3 жыл бұрын
Frankly spoken: We do not launch a product without a) approvals and certificates and b) our confidence that the respective product is a valid solution.
@neelamsingh54
@neelamsingh54 3 жыл бұрын
S
@neelamsingh54
@neelamsingh54 3 жыл бұрын
#Store
@Beniamin6665
@Beniamin6665 3 жыл бұрын
Bull shit. Where is it code that you don’t need slope on these
@cannonplumbinganddrainllc4221
@cannonplumbinganddrainllc4221 3 жыл бұрын
no thanks
10 Reasons Why You'd FAIL a Plumbing Inspection! | GOT2LEARN
7:36
Geberit Monolith 2016 WC Floor drain - Installation
6:21
Geberit
Рет қаралды 2,3 МЛН
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 35 МЛН
A teacher captured the cutest moment at the nursery #shorts
00:33
Fabiosa Stories
Рет қаралды 52 МЛН
Geberit Silent-Pro SuperTube Bottom Turn - Installation
1:54
Facq - Geberit - Silent PP hydraulic installation
1:58
Aliaxis single stack solutions explained
2:33
HEBEISHGROUP
Рет қаралды 9 М.
Water Supply in High Rise BUildings   2
22:44
Vidya-mitra
Рет қаралды 15 М.
What Happens When You Poop in A Burj Khalifa's Toilet
7:46
Tech Space
Рет қаралды 1 МЛН
How Do P-Traps Work? | Spec. Sense
2:24
AMRE Supply
Рет қаралды 2,3 МЛН
Skyscraper Water Supply | Strip the City
2:17
Science Channel
Рет қаралды 257 М.
Geberit Pluvia Siphonic Roof Drainage
2:46
Geberit
Рет қаралды 76 М.
头还可以刷卡买东西的吗?#海贼王#路飞
0:26
路飞与唐舞桐
Рет қаралды 10 МЛН
小丑与白天使遇见丧尸?#short #angel #clown
0:32
Super Beauty team
Рет қаралды 12 МЛН
♥️♥️♥️
0:20
Татьяна Дука
Рет қаралды 7 МЛН