4 types of dg checklist that every engineer should know
What is preventive maintenance
Preventive maintenance is the process of scheduled checking, replacement of parts, and servicing of a machine to maintain the performance of the machine, increase the efficiency and continue the reliability of the machine.
Why it is important
It is cost-saving
Increase the efficiency of the machine
Reduce the breakdown time of the machine
To Continue the safety of the machine
Diesel generator preventive maintenance dg checklist
There are mainly four types of dg checklist that perform on during preventive maintenance
A check
B check
C check
D check
A check
A check performs daily checking procedure of diesel generator sets.
Check oil level in the diesel generator sets.
Check cleanliness of diesel generator sets.
Check battery voltage
Check for any type of leakage
Check all filter condition
Check coolant level
Check the condition v-belts
B-check-B-check performs on weekly basis or after running hours of (300-350) hours.in this type of check following parameters should be checked:
Change oil
Change oil filter, fuel filter, and bypass filter
Change air filter
Change water separator
Radiator cleaning with chemical
C-check-c-check performed on monthly basis or after running hours of (800-1500) hours
Check all electrical conditions
Check pollution level
Change oil
Change oil filter, fuel filter, and bypass filter
Change air filter
Change water separator
Radiator cleaning with chemical
D-check-D-check performed on yearly basis or after running hours of (3000-5000) hours.
The complete dg set should be dismantled.
turbocharger service
injector pin service
cylinder head service
PT pump service
Change oil
Change oil filter, fuel filter, and bypass filter
Change air filter
Change water separator
Radiator cleaning with chemical
video created by unnipgs electrotech
DG Cummins 380kva
Powerica Stamford sunitha sales and service
topic covered
1. DG maintenance procedure
2. A check
3 B check
4. C check
5. D Check
6 coolant checking
7 oil level checking
8 diesel level checking
9 v belt checking
10 battery voltage checking

Пікірлер: 92
@babukrishanankk3502
@babukrishanankk3502 Жыл бұрын
പാനൽ ബോക്സുകളുടെ ഒരോന്നിന്റെയും ഇംഗ്ലീഷിലുള വാക്കുകളുടെ ഫൂൽ ഫോമിനി നെ കുറിച്ച് ഒരു വിഡിയോ ചെയ്യാമോ
@Krishnakumar-zw7tm
@Krishnakumar-zw7tm 2 жыл бұрын
🙋‍♂️ thanks bro.ചാനൽ സബ്സ്ക്രൈബ് ചെയ്തിട്ടുണ്ട്
@AnishKumar-dq5kc
@AnishKumar-dq5kc Жыл бұрын
Well explained & appreciate your effort.
@wilsonsebastian3784
@wilsonsebastian3784 Жыл бұрын
Thank you sir 👍👍
@travellizm5738
@travellizm5738 5 ай бұрын
ഓയിൽ ഫിൽറ്ററിന്റെ അടുത്തുള്ളത് coolant ഫിൽറ്റർ ആണ് ബ്രോ
@exclusivesafar
@exclusivesafar 11 ай бұрын
Good job 👍
@firozlatheafzeanath2465
@firozlatheafzeanath2465 3 жыл бұрын
Thanks...😍
@pranavcpcp1364
@pranavcpcp1364 Жыл бұрын
Poli
@Thethirdeye020
@Thethirdeye020 Жыл бұрын
Thank u so much sir
@mohammedajmal6798
@mohammedajmal6798 2 жыл бұрын
125kva Generator ഒരു 3kw usageന് ഉള്ള loadൽ Run ചെയ്യുമോ.അങ്ങനെ run ചെയ്യുമെങ്കിൽ എത്രയായിരിക്കും AVG fuel consumption
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
വർക്ക് ചെയ്യുന്നതിനു കുഴപ്പമൊന്നും ഇല്ല . പക്ഷെ നിങ്ങൾക്ക് ഒരിക്കലം അത് മുതലാകില്ല. പല കമ്പനികൾക്കും റേഞ്ച് വ്യത്യസ്തം ആണ് എന്നാലും 10 ലിറ്ററിനടുത്തു മണിക്കൂരിൽ വരും പിന്നെ എങ്ങനെ ഉപകാരപ്പെടും.
@mohammedajmal6798
@mohammedajmal6798 2 жыл бұрын
@@unnistechvlogs ok
@THEPYRAMID-wl6mc
@THEPYRAMID-wl6mc Жыл бұрын
Bro 250kva dg oil change cheyanm ethra litter aanu oil vendi varunnathu pls help
@mafrookmafrook6533
@mafrookmafrook6533 8 ай бұрын
I need a generator technician with minimum 7years experience......
@ajilajilks6052
@ajilajilks6052 2 жыл бұрын
Dg set polution eganeyanu check cheyyendathu ?
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
Keralathil proper aayi pollution test nadathunna sthapanathe patti enikku arivilla Mattu raajyangalil athinulla samvidaanam und Athu exhaust lineil ninnum sample shegarichu padanam nadathi aanu report nalkunnath . Evide service provider aayittulla company nammal avashyappettal report nalkum Pakshe vasthuthaa paramaaya onnum athil undaakilla ..
@aamirzaheer9578
@aamirzaheer9578 9 ай бұрын
Technitian course naattil evdelum ulathayi aryo Short term practical course!? Ariyel on share cheyuvo
@unnistechvlogs
@unnistechvlogs 9 ай бұрын
അറിയില്ല ബ്രോ. അന്വേഷിച്ചു പറയാം.
@ksaln1751
@ksaln1751 2 жыл бұрын
ഒരു വലിയ ജനറേറ്റർ വർക്കിംഗ് ചൂടായി ഓഫ് ആവുന്നു. ഒരു മെക്കാനിക്കിനെ കൊടുന്നു അവർ നോക്കിയിട്ട് എ വി ആർ കംപ്ലൈന്റ് ആണ് എന്ന് പറഞ്ഞ് മാറ്റി. വീണ്ടും അതേ പ്രശ്നം എന്തായിരിക്കും സാർ കംപ്ലൈന്റ്
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
bro ചൂടായി ഓഫ്‌ ആയി പോകുന്നു എന്നു പറഞ്ഞാൽ ഹൈ ടെമ്പുരേച്ചർ സെൻസ് ആയി പാനൽ ബോർഡിൽ അലാറം വന്നു പ്രൊട്ടക്ഷൻ മോഡ് ഓൺ ആയി അലാറം വന്നു ഓഫ്‌ ആയതാണോ.
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
ചുടായി ഓഫ്‌ ആകുന്നത് ആണ് എങ്കിൽ അതു റേഡിയേറ്റർ വാട്ടർ സർക്കുലേഷൻ പ്രോപ്പർ ആയി നടക്കാത്തത് ആണ്. സാധാരണ വലിയ ജെൻ സെറ്റുകളിൽ അതു സംഭവിക്കാറില്ല 1. കൂളെന്റ് നോക്കുക 2. കൂളെന്റ് ലെവൽ നോക്കുക 3 വാട്ടർ സർക്കുലേഷൻ ആകുന്നുണ്ടോ എന്നു പരിശോധിക്കുക 4. ബെൽറ്റുകൾ എല്ലാം ഒന്ന് പരിശോദിക്കുക 5 tempurature സെൻസർ പരിശോധിക്കുക 6 engine ഓൺ ആക്കി temp gauge. പരിശോധിക്കുക 7. ഓയിൽ ലെവൽ നോക്കുക ഒപ്പം ഓയിൽ കട്ടിയായിട്ടുണ്ടോ എന്നു നോക്കുക 8 dg ലോഡിൽ ആണ് ഓഫ്‌ ആകുന്നത് എങ്കിൽ 3 phase ലോഡ് ബാലൻസ് ആണോ എന്നു പരിശോധിക്കുക .
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
air ഫിൽറ്റർ കൂടെ ഒന്നു പരിശോദിക്കുക.
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
Valiya generator ennu paranjal ethra kva aanu ennu arinjaal nannayirunnu Njan mukalil paranjathu ellam valiya gen seetukalude karyam aanu AVR എന്നു പറഞ്ഞത് കൊണ്ടാണ് ഒരു സംശയം Automatic voltage regulator Compliant kondu choodaayi off aakunna prashnam varilla Bcs It an voltage protection system
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
Call me bro Njan oru number tharaam vilichaal mathi my number 9747536436 Whatsapp
@birdeyeview3901
@birdeyeview3901 2 жыл бұрын
Hai Bro.... എന്തോകെ ടെസ്റ്റ് അണ് Generator Batteryiku വേണ്ടി ചെയ്യാറുള്ളത്? എത്ര കൂടുമ്പോൾ ചെയും? Vendor anno അതോ ഇൻ ഹൗസ് team anno battery maintenance ചെയ്യാറുള്ളത്....?
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
Battery voltage dg യിൽ നിന്നും നേരിട്ടും അതുപോലെ ബാറ്ററി ചാർജറിൽ നിന്നും ചാർജിങ് വോൾട് എന്നിവ ദിവസവും എടുക്കണം കൃത്യമായി ചാർജ് ആകുന്നുണ്ടോ എന്നു പരിശോധിക്കണം ബാറ്ററി വാട്ടർ ഒഴിക്കുന്ന ബാറ്ററി ആണ് എങ്കിൽ വാട്ടർ ലെവൽ കൂടെ നോക്കണം vendor നോക്കിയാലും അതിനു ചാർജ് ചെയ്യും service replacemet ഒക്കെ ഉടമയുടെ ഉത്തരവാദിത്തം ആണ്.
@vishakhh3676
@vishakhh3676 Жыл бұрын
@@unnistechvlogs Electrical maintenance/operation and maintenance of transformers, D.G sets repair and maintenance of all electrical accessories/equipment interview topic ഇതിനെ കുറിച്ച് വീഡിയോ ചെയ്യുമോ
@unnistechvlogs
@unnistechvlogs Жыл бұрын
ഒറ്റ ഒരു വിഡിയോയിൽ ഒന്നും അത് ഒതുക്കാൻ പറ്റില്ല bro. നമ്മുടെ ചാനലിൽ പലതായി വിഡിയോകൾ ഉണ്ട് ചാനലിൽ വീഡിയോ സെക്ഷൻ നോക്കി ബ്രോക്കു പറ്റുന്ന ടോപിക്സ് ഉണ്ടോ എന്ന് പരിശോധിക്കുക സംശയം ഉള്ളത് ചോദിച്ചാൽ എനിക്ക് അറിവുള്ളത് ആണെങ്കിൽ പറഞ്ഞു തരാം
@vishakhh3676
@vishakhh3676 Жыл бұрын
@@unnistechvlogs interview topic ഇതു ആണ് ഇതു എല്ലാംകൂടി ചുരുക്കി ഒരു വീഡിയോ ചെയ്യുമോ
@vishakhh3676
@vishakhh3676 Жыл бұрын
@@unnistechvlogs university Electrician Job ആണ് അതിൽ ചോദിക്കാവുന്ന interview questions ഒന്നും ചെയ്യുമോ plz
@maildeepusnair
@maildeepusnair 2 жыл бұрын
Hai chetta dg setil voltage varunnilla 220 480. 59 v kanikkunu avr problem ano
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
Haunting ellengil avr compliant aanu bro.
@nisarrahmanmohammed9402
@nisarrahmanmohammed9402 Жыл бұрын
Hi bro.. Kirloskar 25 kv generatoril Enganeyaan voltage increase cheyyal..?
@unnistechvlogs
@unnistechvlogs Жыл бұрын
Rpm 1500 aano ennu nokku bro 1450 vannaal thanne constant voltage aakum.
@SHYJUPYESUDASAN
@SHYJUPYESUDASAN 11 ай бұрын
Avr adjust ചെയ്യ്തു നോക്ക്
@musthafapv1067
@musthafapv1067 2 жыл бұрын
👌
@madhu.haikottayil2178
@madhu.haikottayil2178 2 жыл бұрын
സർ ATS പാനൽ DG with MDB വിഡിയോ ചെയ്യാമോ
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
ഒരു വിഡിയോ ചാനലിൽ ഉണ്ട് ബ്രോ .
@vaishnavatheertham4171
@vaishnavatheertham4171 2 жыл бұрын
Three phase ജനറേറ്റർറിൽ മുന്ന് phaseil നിന്നും ഒരേപോലെ ലോഡ് എടുത്തു ഇല്ലങ്കിൽ എന്തെങ്കിലും പ്രോബ്ലം ഉണ്ടാകുമോ ഒന്ന് പറഞ്ഞുതരാമോ
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
ഒരു വാഹനത്തിന്റെ ഉദാഹരണം ഒരു ഓട്ടോ എടുക്കാം അതിന്റെ ഒരു വീൽ പഞ്ചറും ഒരു വീലിൽ 20% air ഉം അവസാനത്തെ വീൽ 100% air ഉം അടിച്ചു ഓടിച്ചാൽ എന്താകും അവസ്ഥ അധിക ദൂരം ഓടില്ല. ഉയർന്ന പവർ ഉള്ള dg കളിൽ 35% വരെ ലോഡ് ഡിഫറൻസ് കാര്യമായി ബാധിക്കില്ല. amf ലോഡ് ഡിഫറെൻസ് ഉയർന്നാൽ dg യെ ഓഫ്‌ ആക്കും പ്രധാനമായും ആർമേച്ചർ ,ഫീൽഡ് , ഗിയർ , ഭയറിങ് എന്നിവയ്ക്ക് തകരാർ ഉണ്ടാകാൻ കാരണം ആകും Unbalanced lode
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
ചെറിയ dg യിൽ 15% വരെ ലോഡ് വ്യത്യാസം കുഴപ്പമില്ല ബാലൻസ്ഡ് ലോഡ് ആക്കുന്നത് ആണ് നല്ലത്.
@vaishnavatheertham4171
@vaishnavatheertham4171 2 жыл бұрын
Thanks 🙏
@newgen6621
@newgen6621 Жыл бұрын
Hi sir, to run a 3 phase induction motor of 5.5kw/7.5HP . What is the kva diesel generator required . People saying starting current required will be high. Please advise how much kva diesel generator required.
@unnistechvlogs
@unnistechvlogs Жыл бұрын
What is the powerfactor mentioned in name plate.
@newgen6621
@newgen6621 Жыл бұрын
Sir it is 0.86
@newgen6621
@newgen6621 Жыл бұрын
@@unnistechvlogs it is 0.86
@unnistechvlogs
@unnistechvlogs Жыл бұрын
15 kva ok aanu pakse 20 kva vangunnath aakum nallath kaaryamaya price differance varilla Bhaviyilum prayojanappedum.. Price difference nokki vanguka bro.
@newgen6621
@newgen6621 Жыл бұрын
@@unnistechvlogs ok thank you. Dg shop was suggesting 25 or 30kva telling initial current required is 3 times etc
@vipinvipinv2670
@vipinvipinv2670 2 жыл бұрын
Company maintenance job padikanamenund
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
Engineering department ulla sthaapanangalil joli cheythaale manasilaku. Sherikkum enthaanu Nammude sadhyatha ennu Allengil. Chilappol oru wireman ennathinu appurathekku oru electricianum chindikkan sadhikkilla
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
Theerchayaayum adutha oru video athine patti thanne cheyyam
@vipinvipinv2670
@vipinvipinv2670 2 жыл бұрын
Njan sremikunnathum angane oru jolik vendi ahn bro I am compleated Iti electrician trade ....factory maintenance fully padikanM oru company il Joli cheyanam eann ah dream so ith vare athinu oru chance kitiyilla nalla oru company um kitiyilla
@vipinvipinv2670
@vipinvipinv2670 2 жыл бұрын
Bro paranjath seriya company Thane ninu padichale nammal real ayi oru Electrician akullu
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
Good luck
@srjnjfmjqa8860
@srjnjfmjqa8860 Жыл бұрын
Hallo. Generator repair course പഠിക്കുന്ന സ്ഥലം കേരളത്തിൽ എവിടെയേലും ഉണ്ടോ
@vipinchandran9508
@vipinchandran9508 Жыл бұрын
Diesel mechanic cource padichitt Dealership(Cummins, kirloskar)il kayariyal mathi trainee ayitt.. Nalla future undavum 👍
@sajithcr9590
@sajithcr9590 Жыл бұрын
Unbalnced load problem kanikkunnu... Enthukondavum
@unnistechvlogs
@unnistechvlogs Жыл бұрын
Load unbalanced aayathu kond korachu load mattu phase lekku mattuka
@sajithcr9590
@sajithcr9590 Жыл бұрын
@@unnistechvlogs mattikoduthittum same problem...
@sajithcr9590
@sajithcr9590 Жыл бұрын
Runningil allatheyum unbalanced load alam kanikkunnund..
@unnistechvlogs
@unnistechvlogs Жыл бұрын
Call me bro.
@sajithcr9590
@sajithcr9590 Жыл бұрын
@@unnistechvlogs number tharumo
@aravinthan9922
@aravinthan9922 Жыл бұрын
Hi bro I got job offer as a generator service engineer at cummins authorised dealer shall I join bro is this worthy job bro please reply
@unnistechvlogs
@unnistechvlogs Жыл бұрын
👌👍
@madhu.haikottayil2178
@madhu.haikottayil2178 2 жыл бұрын
സർ 220/380 DG ആണ് ഇതിൽ ന്യൂട്രലിൽ രണ്ടിലും 220 ഫേസ് വരുന്നു ഇങ്ങനെ കാണിക്കോ
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
റെക്ട്ടിഫയർ കംപ്ലൈന്റ് ആയി കാണും അതാണ്
@madhu.haikottayil2178
@madhu.haikottayil2178 2 жыл бұрын
അത് എന്താണ് റെക്ട്ടിഫയർ '
@madhu.haikottayil2178
@madhu.haikottayil2178 2 жыл бұрын
സാധാരണ അങ്ങനെ വരുമോ സാർ
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
ഇതിനെ ശെരിക്കും avr എന്നു പറയും automatic voltage regulating system Gen setill undaakunna voltagine കൃത്യമായി നിലനിർത്തുക N p ഇവ യുടെ പൊലാരിറ്റി കൃത്യമായി നൽകുക ഇവയാണ് അതിന്റെ ഉപയോഗം വിശദമായി പറയാൻ ഒരുപാട് ഉണ്ട് bro. പറ്റിയാൽ കാണിക്കാം.
@Jerry.m837
@Jerry.m837 2 жыл бұрын
Charging alternator looks disaster
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
good observation, 👍
@Anu-gy4yj
@Anu-gy4yj 4 ай бұрын
മച്ചാനെ പൊളി വീഡിയോ നിങ്ങളെ number comments ചെയ്യുമോ
@eldhojames2373
@eldhojames2373 2 жыл бұрын
Nobr തരുമോ
@unnistechvlogs
@unnistechvlogs Жыл бұрын
Description box ill und bro Channel about athilum und.
@sujithchikku7012
@sujithchikku7012 2 жыл бұрын
Number onnu parayane
@madhu.haikottayil2178
@madhu.haikottayil2178 2 жыл бұрын
brother ജനറേറ്റർ ന്യൂട്രൽ ഫെസ് കാണിക്കോ
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
NUTREL earth ചെയ്തിട്ടുള്ള dg യിൽ കാണിക്കില്ല പക്ഷെ ചെറിയ ജനറേറ്റർ ill ലോഡ് ഓവർ ആയി കൂടിയാലും അതുപോലെ റെക്ട്ടിഫിക്കേഷൻ കംപ്ലൈന്റ് കൊണ്ടും കാണിക്കാം
@amalkrishnan1038
@amalkrishnan1038 2 жыл бұрын
പ്ലീസ് നമ്പർ ഒന്ന് തരുമോ
@unnistechvlogs
@unnistechvlogs 2 жыл бұрын
9747536436 രാത്രി പരമാവധി കാൾ ഒഴിവാക്കണേ പകൽ ഇപ്പോൾ വേണമെങ്കിലും വിളിക്കാം ജോലി തിരക്കുകളിൽ ആണെങ്കിൽ ചിലപ്പോൾ എടുക്കില്ല തിരികെ വിളിക്കും സംശയങ്ങൾ വാട്ട്സാപ്പ് ചെയ്യാം
@vibaleshpp7308
@vibaleshpp7308 7 ай бұрын
Bro number tharo
@techtechishare5604
@techtechishare5604 Ай бұрын
Hi ... Contact number share cheyyaamo...
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 43 МЛН
Пройди игру и получи 5 чупа-чупсов (2024)
00:49
Екатерина Ковалева
Рет қаралды 3,1 МЛН
ALL ABOUT NEUTRAL IN MALAYALAM
9:49
ELECTRICAL AASHAAN
Рет қаралды 48 М.
Preventive Maintenance of Genset
16:01
JOT POWER
Рет қаралды 39 М.
Top 10 Diesel generator interview questions and answers
7:05
electrical mastar
Рет қаралды 53 М.
Diesel Engine Working | 4 Stroke & 2 Stroke | DI & IDI | Malayalam
12:58
Ajith Buddy Malayalam
Рет қаралды 219 М.
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 43 МЛН