Globe valve Vs Balancing valve | HVAC | in Urdu/Hindi

  Рет қаралды 8,802

Tanweer Ahmed

Tanweer Ahmed

Күн бұрын

Пікірлер: 36
@danishkhadim4048
@danishkhadim4048 2 ай бұрын
In an hydronic HVAC system with a 2-pipe direct return setup, we use balancing valves to make sure each machine gets the right amount of water. Balancing valves are installed at the outlet and manually set to have desired flow rate (GPM). Once adjusted, the balancing valve stays in place to ensure each machine gets only the water it needs. Additionally, an automatic control valve, with the help of a thermostat in the air conditioning space, adjusts the flow of water based on air conditioning needs. Balancing Valve will not automatically adjust flow rate , we manually adjust balancing valve to setup the flow we want to have in that machine .
@TanweerAhmed
@TanweerAhmed 2 ай бұрын
Okay
@ahsankhan8494
@ahsankhan8494 4 ай бұрын
Very good information
@TanweerAhmed
@TanweerAhmed 4 ай бұрын
Thanks
@NafeesChohan773
@NafeesChohan773 5 ай бұрын
JazakAllah Khairah Brother 🥰
@TanweerAhmed
@TanweerAhmed 5 ай бұрын
Thanks
@shadabrehman709
@shadabrehman709 2 жыл бұрын
Very good information.
@TanweerAhmed
@TanweerAhmed 2 жыл бұрын
Welcome
@muhammadai4160
@muhammadai4160 Жыл бұрын
Salam alaikum excellent channel Mr ❣️
@TanweerAhmed
@TanweerAhmed Жыл бұрын
وعلیکم سلام
@taqirkan7712
@taqirkan7712 Жыл бұрын
Assalam O Allikum Sir...let say if we have 4 AHUs at 700 TR operating at 75% load. Let say, if out of 4 AHUs, 2 are turned off for maintainace aand their balancing valves are turned off as well and other 2 are running at the same load, then where will the remaining chilled water be going which was providing chilled water to AHUs which are tunred off dor maintainace?
@TanweerAhmed
@TanweerAhmed Жыл бұрын
W.Salam, I have explained in video. However, if constant flow system then 3-way valves are installed with AHUs and water bypass from 3-ways. If variable water system is installed then 2-way installed at AHUs and pump's will be VFD drive and also bypass in chiller plant room.
@mohammedsaadsaqibareeba9889
@mohammedsaadsaqibareeba9889 3 жыл бұрын
Assalmalikum tanveer sab App bahut acchay vedioes banatay hai MEP sector may Thank you , DRV why its called double regulating valve ,is it double means working in cold and hot watwer conditions, pls explain and make one vedoie on how to balance at site
@TanweerAhmed
@TanweerAhmed 3 жыл бұрын
W.Salam and thanks Insha'Allah will prepare video on it
@rashidkhan8783
@rashidkhan8783 3 жыл бұрын
Wa ALAKUM SALAM very nice
@TanweerAhmed
@TanweerAhmed 3 жыл бұрын
Thanks
@indiantraveller194
@indiantraveller194 Жыл бұрын
Bhai jaan category kaun sa select kare channel ka hvac banana hai please batayein
@TanweerAhmed
@TanweerAhmed Жыл бұрын
Science & Technology
@moideenyousaf3757
@moideenyousaf3757 3 жыл бұрын
👍👍👍
@TanweerAhmed
@TanweerAhmed 3 жыл бұрын
Thanks
@ammarkhan2851
@ammarkhan2851 3 жыл бұрын
Sir plz uplod all types of plumbing drawing reading
@TanweerAhmed
@TanweerAhmed 3 жыл бұрын
Insha'Allah will upload after prepare video
@علیچوہدری-ذ6ي
@علیچوہدری-ذ6ي 3 жыл бұрын
3vav k bary main information dien sir
@TanweerAhmed
@TanweerAhmed 3 жыл бұрын
3vav?
@علیچوہدری-ذ6ي
@علیچوہدری-ذ6ي 3 жыл бұрын
@@TanweerAhmed 3way volve
@TanweerAhmed
@TanweerAhmed 3 жыл бұрын
Sure, I am working on it
@jitendrasinghbhadoriya3980
@jitendrasinghbhadoriya3980 3 жыл бұрын
Sir why cwt weight is Half of capacity+empty car weight
@jitendrasinghbhadoriya3980
@jitendrasinghbhadoriya3980 3 жыл бұрын
Sir plz give me a ans With Logic
@TanweerAhmed
@TanweerAhmed 3 жыл бұрын
Because save motor power energy
@jafarkasim5600
@jafarkasim5600 3 жыл бұрын
Kisi ko kuc v kaam na malum ho us k ley suro se kuc batay
@TanweerAhmed
@TanweerAhmed 3 жыл бұрын
My all videos are for new Engineers or students for learners
兔子姐姐最终逃走了吗?#小丑#兔子警官#家庭
00:58
小蚂蚁和小宇宙
Рет қаралды 9 МЛН
小丑家的感情危机!#小丑#天使#家庭
00:15
家庭搞笑日记
Рет қаралды 34 МЛН
А что бы ты сделал? @LimbLossBoss
00:17
История одного вокалиста
Рет қаралды 10 МЛН
Double Regulating Valve | DRV | in Urdu/Hindi
15:01
Tanweer Ahmed
Рет қаралды 30 М.
PICV Explained - Pressure Independent Control Valves
10:52
The Engineering Mindset
Рет қаралды 207 М.
Three Way Valve of HVAC System in Urdu/Hindi
9:32
Tanweer Ahmed
Рет қаралды 37 М.
HVAC Project complete overview Related to #hvac in Urdu/Hindi
18:50
HVAC TECHNOLOGY
Рет қаралды 11 М.