Growatt 3x SPF5000ES Parallel with batteries (Settings)

  Рет қаралды 2,351

Golden4o

Golden4o

6 ай бұрын

In the video we are going through my 3x Growatt inverter settings.
The system is with 3x Growatt SPF5000ES inverters working in parallel in a single phase with 7 batteries.
#SPF5000ES #growattsettings #diysolar

Пікірлер: 13
@LX777
@LX777 6 ай бұрын
Very useful and well done. Thank you
@poleznoszdrave
@poleznoszdrave 6 ай бұрын
Браво! Много полезно видео!
@eddywouters3044
@eddywouters3044 3 ай бұрын
Setting 23? When you are using single phase with 3 inverters in parallel the manual says to set it to PAL instead of SIG. But then it gives me a fault. What is your opinion? I am using exactly the same combination as your system...
@golden4o
@golden4o 3 ай бұрын
I cannot access Setting 23, from 21 it jumps to 28. My guess is that the communication between the inverters is not properly connected.
@freshia2008
@freshia2008 5 ай бұрын
Sir what is the Max. PV input current of this inverter ?
@golden4o
@golden4o 5 ай бұрын
18 Amps
@angelkm2599
@angelkm2599 2 ай бұрын
hello, I have an identical installation with 3 inverters 5 kW mounted in parallel with a total single-phase output of 45 kw but I have a three-phase public network subscription of 15A per phase, I would like to know if it is possible to make the network injection of the 3 phases with one phase per inverter
@golden4o
@golden4o 2 ай бұрын
Yes, you can make the inverters work in 3 phases and connect each phase of the residential network to the inverters. You can check the manual on how exactly you can connect them. I'm planning to switch to 3 phases as well as I have 3 phases coming to my house. Before you do that please make sure to balance each phase in your house. Because with 3 inverters you will have 5KW on each phase. (Total 15KW on the 3 phases)
@angelkm2599
@angelkm2599 2 ай бұрын
@@golden4o Thank you for your feedback but I want to stay in parallel mono and inject each phase in an inverter thank you
@golden4o
@golden4o 2 ай бұрын
@@angelkm2599 If you want to stay on single phase with the inverters and inject, you can only do that with one of the 3 phases that are coming to your house. Just grab one of the phases and connect it to the input of each inverter.
@angelkm2599
@angelkm2599 2 ай бұрын
​@@golden4o there is a risk of connecting the 3 phases if why, because each inverter normally sends its current, so I do not understand the risk and thank you again for your return
@golden4o
@golden4o 2 ай бұрын
@@angelkm2599 The inverters cannot convert 3 phases into a single phase. No inverter can do that (as far as I know). So in order to use 3 phases, your inverters must be in 3 phase mode. If they are in single phase mode, you can only input single phase.
Growatt Settings LiFePO4
9:14
Roll2 Videos
Рет қаралды 48 М.
HomeGrid Lithium Battery Review!
15:30
Engineer775
Рет қаралды 27 М.
БАБУШКИН КОМПОТ В СОЛО
00:23
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 17 МЛН
World’s Largest Jello Pool
01:00
Mark Rober
Рет қаралды 99 МЛН
A little girl was shy at her first ballet lesson #shorts
00:35
Fabiosa Animated
Рет қаралды 15 МЛН
Growatt 5000 ES Settings
9:04
Richard de los Santos
Рет қаралды 16 М.
Growatt SPF 5000 ES Parallel Installation with batteries
37:54
lvtopsun battery running with growatt 6000es
2:48
Wuttipong Kl
Рет қаралды 803
Victron three phase Off Grid build with Multiplus 2 and Ruixu battery
16:37
Joondalup Electrical Services
Рет қаралды 2,1 М.
Growatt Fault 62 Troubleshooting
4:29
Ian's Solar Projects
Рет қаралды 3,1 М.
Add additional Pylontech batteries to an existing battery bank
6:08
Zayd’s House
Рет қаралды 53 М.
Growatt SPF 5000es bug in 3 phase system
2:07
DeyanV
Рет қаралды 10 М.
Growatt SPF 5000 ES max pv input current and overpanneling
12:01
Дальше без меня!
0:25
SMASHCAR
Рет қаралды 582 М.
BMW M5 VS COBALT  QANCHAGA TUSHDI 😱💣
0:17
Comfort zone avto
Рет қаралды 2,5 МЛН
Every car need this.#car #carhack #shortsyoutube
1:00
Chaudery Auto Traders
Рет қаралды 6 МЛН