Been a spark for 16 years and I’ve never terminated this kind of cable before. I’ve worked with braided cable many times as having worked in the oil & gas industry for the past 8 years. Although it’s different glands you actually terminate the braiding of the cable as you would with a SWA cable/gland. Very interesting and informative video and I’m extremely humble to have came across something I’ve never done and to learn about it!
@whitebeltlyfbjj33932 жыл бұрын
I've learnt more from this channel...than from college....I got am2 coming up...really helpful
@GSHElectrical2 жыл бұрын
All the best with AM2 and thanks for watching and the positive feedback 👍🏻. Gaz
@Beariam242 жыл бұрын
Another great vid guys. I’m glad your showing the younger ones how to do it correctly. Hopefully we will see correctly glanded sy on AC units in the future. Personally I bloody hate the stuff and it should be sent to hell. Nearly all my commercial inspection I do, SY has been installed terrible and the condition of the cable if stupidly used out side or in damp conditions is appalling.
@makg46552 жыл бұрын
It shouldn’t be used that’s why ITS NOT FOR CARRYING VOLTAGE IN U.K. JUST CONTROL GEAR … as for using the braided for earth lol it’s not for that in any way IET & NICEIC BOTH SAY SY IS A C3 min but a C2 if showing any sign of thermal damage ( which it does if any voltage ever goes to the braiding)
@littlechestnutorchard2 жыл бұрын
Years ago I used to install commercial catering equipment and wired them up with SY cable. Those days I haven't seen any special gland for the SY ( or my wholesaler never heard of it) so I improvised external SWA glands by slitting the main section with metal hacksaw and terminate the SW as you did. Great job by the way.
@tomcardale55962 жыл бұрын
That's cunning. I've never seen an SY gland, just seen it through a regular compression gland and if you're lucky the braid in to an earth terminal.
@S.Wardell Жыл бұрын
A little trick for cutting the braiding back. If you make a little hole by peeling the braiding to each side you can hoop the cable through and cut off the braiding where needed. I've always linked my braiding to earth directly however and sleeved.
@abdulseaforth69304 ай бұрын
Thanks Gaz. Assessment tomorrow
@GSHElectrical4 ай бұрын
AM2 and AM2S Hints and Tips for the Electrical Apprenticeship end Point Assessment. kzbin.info/www/bejne/o4eWcoKLpK-kbck
@dwightsilagan89622 жыл бұрын
I love your , channel and tools and instrument hoping for more video, i wish i could have your tools and instruments
@giubaca7 ай бұрын
What's stopping you going twice round the thread with that braid? And then back into the split? I find it stays in a lot better and is neat
@engdarfatgalalyelectrical10762 жыл бұрын
Your information is good and useful
@GSHElectrical2 жыл бұрын
Thanks for watching and the support 👍🏻
@ashvanbro93292 жыл бұрын
Great video gaz
@khadarhassan7112 жыл бұрын
Hello sir I learned about electricity from KZbin very well and I want you to take it from me, a test on electricity
@lawrencer252 жыл бұрын
Great video 👍👍👍👍
@Jack-zr4lm2 жыл бұрын
Where can I get the 20/25 lock nut spanner?
@pjeaton586 ай бұрын
Use a large adjustable ????
@MysteriousDrJ8 ай бұрын
The smaller SY outer sheath is a perfect size to remove capsule lamps from control panels
@alunroberts14392 жыл бұрын
Very good thanks for that good video
@GSHElectrical2 жыл бұрын
Thanks for watching and commenting 👍🏻
@dennisphoenix12 жыл бұрын
The cable gland could be designed better by having a cup shaped washer and a flat washer to keep the strands in place . The same as a CPC connection on an immersion heater .
@GSHElectrical2 жыл бұрын
Thanks for the comment 👍🏻
@makg46552 жыл бұрын
@@GSHElectrical WHY ARE YOU USING / promoting SY ?? AS OTHERS HAVE SAID SY DOES NOT CARRY AS BS no. AFTER CONSULTING NICEIC & IET THEY HAVE BOTH SAID SY IS A C2 if showing any signs of thermal damage. As the braiding is not designed to carry any voltage it should not be used as an earth .. SY IS FOR CONTROL CABLE.. SURELY YOU SHOULD BE TELLING STUDENTS NOT TO USE IT .. there is cable manufacturers looking at making SY & getting it a BS but untill then you are installing a C ISSUE IF USED . PI** POOR PRACTICE!!!!!
@stephen526113 күн бұрын
You can get SY glands with a chrome finish that looks like a skintop gland but has a brass top hat inside, much better glands
@sve762 жыл бұрын
Been a sparky since 1995 and never even knew they done glands for sy
@GSHElectrical2 жыл бұрын
Thanks for watching and commenting 👍🏻
@LV-sb9nz2 жыл бұрын
Hi mate any chance U could do a video on master switching and din rail time switches? keep up the good content mate
@dannyasp9869 Жыл бұрын
Hi, would it be acceptable to fix the earth rings down with a locknut before putting the gland into the consumer unit to make it easier ? Then another locknut inside the consumer unit to hold the gland in place?
@dansheppard29652 жыл бұрын
Can't help thinking gland manufacturers could do something to help keep the armouring between the washers. Some kind of rim, maybe? That looks like a real faff.
@mr.t88302 жыл бұрын
WARNING. That gland is fine made off like that when it’s inside but not when used externally installed in that fashion, and I’ve seen hundreds no thousands of them especially on air con units, the braid acts like a wick and draws moister down the braid is then heated by the sun causing mould growth and corrosion destroys the earth continuity to the braid and eventually fills the lower end switch or joint box with water If you look at the gland the split stops short of the base you need to make off with the two rings or washers on the inside thus preventing moister to enter between the external pvc and cable sheath,
@mr.t88302 жыл бұрын
Oh yes forgot to mention it’s also not suitable to be used outside in the first place but unfortunately it dose get used, so at least stop the water getting in or use a suitable cable even better.
@GSHElectrical2 жыл бұрын
My learners need to make off an SY cable as part of an assessment hence the video 👍🏻
@Andrew-bl2vo Жыл бұрын
Haven't seen that type of specific 20/ 25mm spanner in 30 odd year's.. where do you purchase them ?
@GSHElectrical Жыл бұрын
That’s a great question and sadly I cannot remember 🫤. Thanks for watching Gaz 👍🏻
@allthegearnoidea67522 жыл бұрын
I was wondering is SY acceptable for fixed installation on trays for example. I used to use SY on machines but always thought it performed very poorly especially in any applications with even small amounts of flexing. The outer sheath can be damaged by the inner braiding and they deteriorate quickly if installed outside. You will always get moisture ingress between the two sheaf clamp washer and water then collect inside the cable braid. In places like New Zealand they use something very similar to SY for all the industrial installations.
@pirate69s2 жыл бұрын
SY does not comply with our BS standard for cables, not sure why it is being promoted here? It is a cable made to a EU standard there are no tables for volt drop or current carrying capacity so it cannot be sized for our UK 18th edition.
@007floppyboy2 жыл бұрын
@@pirate69s All manufactures produce the data sheets including volt drop and current capability. The BS 7671 is just a guide, you should always use the manufactures data sheets. And 6mm is 6mm is 6mm, volt drops will always be the same. They will have different current ratings, and that is dependent on the level of insulation and at what temperature it can stand.
@pirate69s2 жыл бұрын
@@007floppyboy You are 100% wrong mate BS7671 is not a guide. It is the regulation, therefore THE LAW.
@ishkebab2 жыл бұрын
Electricians shears work a treat for removing the braid.
@GSHElectrical2 жыл бұрын
Unlikely to get a set of them in a college tool box 👍🏻
@ishkebab2 жыл бұрын
@@GSHElectrical I used to get a butter knife in my college days……. Bloody useless it was !
@o0li5532 жыл бұрын
可以,但剪刀可能有損壞
@doomain6769 Жыл бұрын
Pretty sure you can use it... Have to Put it down as a departure from bs7671 on certificate and fill in box for other type of cable on circuit schedule..
@jon47com8 ай бұрын
Any departure from BS7671 must meet or exceed the UK standards, how can you show it does when you have no current carrying capacity of the braid under fault conditions. Even the manufacturers say it is only for controls not fixed wiring for power supplies.
@EdwardBretherton11 ай бұрын
why is the banjo on the outside of the consumer unit
@seandempsey73512 жыл бұрын
Don’t think I have ever seen SY flex, it looks like that American kopex that aluminium flexy conduit that’s pre wired . Were would SY flex be used ? Great video Gaz as always 👍👍👍❤️
@sugardaddyxxx2 жыл бұрын
Normally on aircon units, from the isolator to the unit, only time I have ever had to use it.
@Daniells19822 жыл бұрын
SY and CY are a contentious one in the UK mate. There's an argument they shouldn't be used as they're designed to a German standard and not a British Standard. They tend to be used for control wiring and I've seen them used on pump sets, possibly because the manufacturer of the pumps sets are outside of the UK.
@arcadia1701e2 жыл бұрын
Sy shouldn't be used anywhere. It's not recognised by British standards. You should be using rubber ho7rn cable.
@martinkennedy85472 жыл бұрын
Where do I buy a lock nut spanner? Great video again btw
@GSHElectrical2 жыл бұрын
If only I could remember 🤦🏻♂️. Thanks for watching. Gaz
@pjeaton586 ай бұрын
Use a large adjustable ????
@syedmaqureshi5590 Жыл бұрын
Excellent
@bencorbin2072 жыл бұрын
Hey, great video as always. We have to make off SY for our college exam, but have been told that we need to take braiding inside box and then crimp. My college is saying this is what is expected in the AM2. Has anyone done the AM2 recently and know which is the required way for it to be fixed?
@mfr58 Жыл бұрын
Not sure about AM2, but that's the way I do it and it's far less fiddly, cheaper and more secure than using those special glands.
@Alfie1178 Жыл бұрын
LAPP SKINTOP MS SC M are far more advanced glands for SY cable and are suitable for areas where spraying or splashing water is likely. They are my preference.
@paulpantsoff65847 ай бұрын
I've seen many professional sparks make the same armoured shroud mistake. If you want your shrouds to have a wobbly cut then do it like this guy. If you want a more concentric and neater cut then push the uncut shroud over the cable in the wrong direction, then cut in a circular motion using the cable as a former, then fit the shroud in the correct direction. Laying it flat for the cut looks toilet.
@tonywatson14122 жыл бұрын
dont project the banjo locking bolt too far into the c.unit.. brass nut with brass hex bolt easy to tighten say 15mm , in length..
@aaronrothwell90262 жыл бұрын
I have just removed alot of this shite cable in a garden which the previous "spark" used to wire lights and sockets! He used the braid as an earth cause he found he did not have enough conductors to do what he wanted to, he terminated the braid in choc blocks in the back of the lights! The cable was undersized also giving massive earth fault loop readings. Needless to say the whole shite got ripped out and replaced with swa.
@GSHElectrical2 жыл бұрын
My learners need to make off SY flex as part of an assessment hence the video 👍🏻
@aaronrothwell90262 жыл бұрын
@@GSHElectrical I appreciate the video, and it's a very good demonstration. The issue I have not with you but in general is the selection of equipment in general for the environment, I have seen this stuff in loads of gardens etc where it is not appropriate, yes it has its uses in industry, but it is not recognised by bs7671 as a previous comment stated. In my opinion its awful stuff and there are better alternatives in certain situations
@pjeaton586 ай бұрын
SY cable is shite - period.
@theavchap2 жыл бұрын
It’s nice to see a CXT gland on some SY for a change. However, the only places I see it used are the exact same places it isn’t designed to be used. There are better alternatives with BS ratings.
@GSHElectrical2 жыл бұрын
Remember we are a college 👍🏻
@jackninnu9719 Жыл бұрын
King Gary
@HMGaming3602 жыл бұрын
Where can I buy the lock nut spanner please?
@GSHElectrical2 жыл бұрын
I wish I could remember 🤦🏻♂️
@pjeaton586 ай бұрын
Use a large adjustable ????
@imranemushtaq10812 жыл бұрын
Can sy be use for power and mains?
@jon47com8 ай бұрын
No, the manufacturers state it is only for controls.
@o0li5532 жыл бұрын
很好,在香港都是這做的,
@dennisphoenix12 жыл бұрын
I was told you couldn't use SY flex as it doesn't have a BS standard .
@GSHElectrical2 жыл бұрын
My learners have to install SY cable as part of an assessment hence the video 👍🏻
@dennisphoenix12 жыл бұрын
@@GSHElectrical is it correct that we can't use it in the UK because it's not got a BS standard, seeing as it's a European cable is there a harmonised standard ?
@makg46552 жыл бұрын
@@dennisphoenix1 & the braiding is not designed to carry voltage .. this video is so wrong . As it’s for U.K. STUDENTS.. he should be telling them it is not to be used in new installations or they are installing a fault.. PI** POOR PRACTICE
@Ste2023 Жыл бұрын
It is was it is
@derekmorrison1973 Жыл бұрын
Got to then ask the question, why are products for SY cable still being manufactured for the UK market, if it is not allowed? I don't know but that's a reasonable question. SY not allowed on Ex installs but allowed in factories and commercial I think.
@andybaker60882 жыл бұрын
Those glands are crap, just use a standard SWA gland and flip the tapered olive upside down so it bites into the braiding and make it off live an SWA, saves time and both....these glands are crap!
@arcadia1701e2 жыл бұрын
Sy cable has no British standard, It shouldn't be used. Use rubber ho7rn cable instead.
@carlmarquardt9942 жыл бұрын
Ok.decent tip. I just had to check a gas flare. Sy cable outside run on ground no cable tray. Looked up the ruling. Tbh I have used it on e or twice and didn't mind it...but rules are rules. Ta
@GSHElectrical2 жыл бұрын
It’s in the end assessment for my learners hence the video
@pirate69s2 жыл бұрын
100% Europen rubbish belongs in Europe!
@makg46552 жыл бұрын
@@GSHElectrical why are you not contacting the assessment body and telling them it shouldn’t be used except for control gear !!!!! How many other things are you teaching that is wrong .. but doing it because the computer says NO 🤔🤔😂😂
@007floppyboy2 жыл бұрын
@@makg4655 SY can be used as supply cable (Low tension feed) I have asked all the manufactures and have their responses on file, its my insurance against owt going t1ts up. To be honest, after years of installing this stuff, Its fine. Carried out inspections on my designs in Nuclear plants and its still ok, after more than 20 odd years in service.
@tonywatson14122 жыл бұрын
who would even bother with this stuff..when there are alternatives available...and are easier to terminate..
@GSHElectrical2 жыл бұрын
It’s part of a practical assessment my learners have to do hence the video
@havoctrousers2 жыл бұрын
I've done electrics for a long time, and I did an apprenticeship many years ago. I was never taught SY and I've never used it. I can't help thinking for the exact same amount of work you might as well use SWA? It's tougher, better and you can use it outside and bury it etc. If you don't need that level of mechanical protection, then you might as well use NYY-J and stuffing glands and save yourself a little bit of faff. Also, I haven't used a banjo in years, those pirahna/earthing nuts are so much less hassle and save you compromising the IP rating of your enclosure.
@ominence55732 жыл бұрын
Cl electrician scissors
@GSHElectrical2 жыл бұрын
Sadly we a stuck with 10 basic tools in our college tool kits 👍🏻
@ominence55732 жыл бұрын
@@GSHElectrical well you had 2 pairs of side cutters.. I think one pair could be dropped and replaced for the scissors.. they are really handy for stranded copper, like in this video :-)
@dead.format Жыл бұрын
No idea why this is taught on the courses. It just encourages thebuse of a sub standard cable
@GSHElectrical Жыл бұрын
But we do have to teach it….
@jon47com8 ай бұрын
I complained to NET about this, they said they included it because it was listed as an acceptable cable by City & Guilds despite the IET saying its use should be discouraged. Personally I think there are plenty of other types of cable that it would be more useful for apprentices to learn how to terminate especially those who will go into industrial work.
@stevenwalker310211 ай бұрын
I know this is the by the book way of doing it, but i really can't see a reason why you cant just use a stuffing gland and take the yarn strait to the cpc terminal inside the enclosure? This has always seemed pointless imo. I haven't used sy in the 10 years since doing my AM2 and I'm a commercial spark (Before I get the housebasher comment). The most pointless cable ever invented also.
@pjeaton586 ай бұрын
SY cable is rubbish and the braid strands are a finger piercing health & safety hazard !!
@007floppyboy2 жыл бұрын
Those glands are simply the worst type of gland I have ever had the misfortune to use. I used them in the 80s, complete joke, and you expect them to improve, no they didnt. If you are thinking of using these stop, chuck em in the bin. Loads of other good glands out there, just like SWA E1W glands or similar, where they grab the flex all around with the olive. Also, if your doing any high frequency work, these glands dont meet latest EMC standards where as an E1W type does.
@GSHElectrical2 жыл бұрын
Thanks for your feedback 👍🏻 these glands are the ones my learners are required to install as part of an assessment hence the video 👍🏻
@sachindas79372 жыл бұрын
Takes to much time, time is money
@GSHElectrical2 жыл бұрын
It’s a requirement for my learners assessment hence the video 👍🏻