SY Cable or SY Flex How to Terminate, Make Off Step by Step Practical Demonstration of Connecting

  Рет қаралды 65,112

GSH Electrical

GSH Electrical

Күн бұрын

Пікірлер: 108
@LP92LEO
@LP92LEO Ай бұрын
Been a spark for 16 years and I’ve never terminated this kind of cable before. I’ve worked with braided cable many times as having worked in the oil & gas industry for the past 8 years. Although it’s different glands you actually terminate the braiding of the cable as you would with a SWA cable/gland. Very interesting and informative video and I’m extremely humble to have came across something I’ve never done and to learn about it!
@whitebeltlyfbjj3393
@whitebeltlyfbjj3393 2 жыл бұрын
I've learnt more from this channel...than from college....I got am2 coming up...really helpful
@GSHElectrical
@GSHElectrical 2 жыл бұрын
All the best with AM2 and thanks for watching and the positive feedback 👍🏻. Gaz
@Beariam24
@Beariam24 2 жыл бұрын
Another great vid guys. I’m glad your showing the younger ones how to do it correctly. Hopefully we will see correctly glanded sy on AC units in the future. Personally I bloody hate the stuff and it should be sent to hell. Nearly all my commercial inspection I do, SY has been installed terrible and the condition of the cable if stupidly used out side or in damp conditions is appalling.
@makg4655
@makg4655 2 жыл бұрын
It shouldn’t be used that’s why ITS NOT FOR CARRYING VOLTAGE IN U.K. JUST CONTROL GEAR … as for using the braided for earth lol it’s not for that in any way IET & NICEIC BOTH SAY SY IS A C3 min but a C2 if showing any sign of thermal damage ( which it does if any voltage ever goes to the braiding)
@littlechestnutorchard
@littlechestnutorchard 2 жыл бұрын
Years ago I used to install commercial catering equipment and wired them up with SY cable. Those days I haven't seen any special gland for the SY ( or my wholesaler never heard of it) so I improvised external SWA glands by slitting the main section with metal hacksaw and terminate the SW as you did. Great job by the way.
@tomcardale5596
@tomcardale5596 2 жыл бұрын
That's cunning. I've never seen an SY gland, just seen it through a regular compression gland and if you're lucky the braid in to an earth terminal.
@S.Wardell
@S.Wardell Жыл бұрын
A little trick for cutting the braiding back. If you make a little hole by peeling the braiding to each side you can hoop the cable through and cut off the braiding where needed. I've always linked my braiding to earth directly however and sleeved.
@abdulseaforth6930
@abdulseaforth6930 4 ай бұрын
Thanks Gaz. Assessment tomorrow
@GSHElectrical
@GSHElectrical 4 ай бұрын
AM2 and AM2S Hints and Tips for the Electrical Apprenticeship end Point Assessment. kzbin.info/www/bejne/o4eWcoKLpK-kbck
@dwightsilagan8962
@dwightsilagan8962 2 жыл бұрын
I love your , channel and tools and instrument hoping for more video, i wish i could have your tools and instruments
@giubaca
@giubaca 7 ай бұрын
What's stopping you going twice round the thread with that braid? And then back into the split? I find it stays in a lot better and is neat
@engdarfatgalalyelectrical1076
@engdarfatgalalyelectrical1076 2 жыл бұрын
Your information is good and useful
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for watching and the support 👍🏻
@ashvanbro9329
@ashvanbro9329 2 жыл бұрын
Great video gaz
@khadarhassan711
@khadarhassan711 2 жыл бұрын
Hello sir I learned about electricity from KZbin very well and I want you to take it from me, a test on electricity
@lawrencer25
@lawrencer25 2 жыл бұрын
Great video 👍👍👍👍
@Jack-zr4lm
@Jack-zr4lm 2 жыл бұрын
Where can I get the 20/25 lock nut spanner?
@pjeaton58
@pjeaton58 6 ай бұрын
Use a large adjustable ????
@MysteriousDrJ
@MysteriousDrJ 8 ай бұрын
The smaller SY outer sheath is a perfect size to remove capsule lamps from control panels
@alunroberts1439
@alunroberts1439 2 жыл бұрын
Very good thanks for that good video
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for watching and commenting 👍🏻
@dennisphoenix1
@dennisphoenix1 2 жыл бұрын
The cable gland could be designed better by having a cup shaped washer and a flat washer to keep the strands in place . The same as a CPC connection on an immersion heater .
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for the comment 👍🏻
@makg4655
@makg4655 2 жыл бұрын
@@GSHElectrical WHY ARE YOU USING / promoting SY ?? AS OTHERS HAVE SAID SY DOES NOT CARRY AS BS no. AFTER CONSULTING NICEIC & IET THEY HAVE BOTH SAID SY IS A C2 if showing any signs of thermal damage. As the braiding is not designed to carry any voltage it should not be used as an earth .. SY IS FOR CONTROL CABLE.. SURELY YOU SHOULD BE TELLING STUDENTS NOT TO USE IT .. there is cable manufacturers looking at making SY & getting it a BS but untill then you are installing a C ISSUE IF USED . PI** POOR PRACTICE!!!!!
@stephen5261
@stephen5261 13 күн бұрын
You can get SY glands with a chrome finish that looks like a skintop gland but has a brass top hat inside, much better glands
@sve76
@sve76 2 жыл бұрын
Been a sparky since 1995 and never even knew they done glands for sy
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for watching and commenting 👍🏻
@LV-sb9nz
@LV-sb9nz 2 жыл бұрын
Hi mate any chance U could do a video on master switching and din rail time switches? keep up the good content mate
@dannyasp9869
@dannyasp9869 Жыл бұрын
Hi, would it be acceptable to fix the earth rings down with a locknut before putting the gland into the consumer unit to make it easier ? Then another locknut inside the consumer unit to hold the gland in place?
@dansheppard2965
@dansheppard2965 2 жыл бұрын
Can't help thinking gland manufacturers could do something to help keep the armouring between the washers. Some kind of rim, maybe? That looks like a real faff.
@mr.t8830
@mr.t8830 2 жыл бұрын
WARNING. That gland is fine made off like that when it’s inside but not when used externally installed in that fashion, and I’ve seen hundreds no thousands of them especially on air con units, the braid acts like a wick and draws moister down the braid is then heated by the sun causing mould growth and corrosion destroys the earth continuity to the braid and eventually fills the lower end switch or joint box with water If you look at the gland the split stops short of the base you need to make off with the two rings or washers on the inside thus preventing moister to enter between the external pvc and cable sheath,
@mr.t8830
@mr.t8830 2 жыл бұрын
Oh yes forgot to mention it’s also not suitable to be used outside in the first place but unfortunately it dose get used, so at least stop the water getting in or use a suitable cable even better.
@GSHElectrical
@GSHElectrical 2 жыл бұрын
My learners need to make off an SY cable as part of an assessment hence the video 👍🏻
@Andrew-bl2vo
@Andrew-bl2vo Жыл бұрын
Haven't seen that type of specific 20/ 25mm spanner in 30 odd year's.. where do you purchase them ?
@GSHElectrical
@GSHElectrical Жыл бұрын
That’s a great question and sadly I cannot remember 🫤. Thanks for watching Gaz 👍🏻
@allthegearnoidea6752
@allthegearnoidea6752 2 жыл бұрын
I was wondering is SY acceptable for fixed installation on trays for example. I used to use SY on machines but always thought it performed very poorly especially in any applications with even small amounts of flexing. The outer sheath can be damaged by the inner braiding and they deteriorate quickly if installed outside. You will always get moisture ingress between the two sheaf clamp washer and water then collect inside the cable braid. In places like New Zealand they use something very similar to SY for all the industrial installations.
@pirate69s
@pirate69s 2 жыл бұрын
SY does not comply with our BS standard for cables, not sure why it is being promoted here? It is a cable made to a EU standard there are no tables for volt drop or current carrying capacity so it cannot be sized for our UK 18th edition.
@007floppyboy
@007floppyboy 2 жыл бұрын
@@pirate69s All manufactures produce the data sheets including volt drop and current capability. The BS 7671 is just a guide, you should always use the manufactures data sheets. And 6mm is 6mm is 6mm, volt drops will always be the same. They will have different current ratings, and that is dependent on the level of insulation and at what temperature it can stand.
@pirate69s
@pirate69s 2 жыл бұрын
@@007floppyboy You are 100% wrong mate BS7671 is not a guide. It is the regulation, therefore THE LAW.
@ishkebab
@ishkebab 2 жыл бұрын
Electricians shears work a treat for removing the braid.
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Unlikely to get a set of them in a college tool box 👍🏻
@ishkebab
@ishkebab 2 жыл бұрын
@@GSHElectrical I used to get a butter knife in my college days……. Bloody useless it was !
@o0li553
@o0li553 2 жыл бұрын
可以,但剪刀可能有損壞
@doomain6769
@doomain6769 Жыл бұрын
Pretty sure you can use it... Have to Put it down as a departure from bs7671 on certificate and fill in box for other type of cable on circuit schedule..
@jon47com
@jon47com 8 ай бұрын
Any departure from BS7671 must meet or exceed the UK standards, how can you show it does when you have no current carrying capacity of the braid under fault conditions. Even the manufacturers say it is only for controls not fixed wiring for power supplies.
@EdwardBretherton
@EdwardBretherton 11 ай бұрын
why is the banjo on the outside of the consumer unit
@seandempsey7351
@seandempsey7351 2 жыл бұрын
Don’t think I have ever seen SY flex, it looks like that American kopex that aluminium flexy conduit that’s pre wired . Were would SY flex be used ? Great video Gaz as always 👍👍👍❤️
@sugardaddyxxx
@sugardaddyxxx 2 жыл бұрын
Normally on aircon units, from the isolator to the unit, only time I have ever had to use it.
@Daniells1982
@Daniells1982 2 жыл бұрын
SY and CY are a contentious one in the UK mate. There's an argument they shouldn't be used as they're designed to a German standard and not a British Standard. They tend to be used for control wiring and I've seen them used on pump sets, possibly because the manufacturer of the pumps sets are outside of the UK.
@arcadia1701e
@arcadia1701e 2 жыл бұрын
Sy shouldn't be used anywhere. It's not recognised by British standards. You should be using rubber ho7rn cable.
@martinkennedy8547
@martinkennedy8547 2 жыл бұрын
Where do I buy a lock nut spanner? Great video again btw
@GSHElectrical
@GSHElectrical 2 жыл бұрын
If only I could remember 🤦🏻‍♂️. Thanks for watching. Gaz
@pjeaton58
@pjeaton58 6 ай бұрын
Use a large adjustable ????
@syedmaqureshi5590
@syedmaqureshi5590 Жыл бұрын
Excellent
@bencorbin207
@bencorbin207 2 жыл бұрын
Hey, great video as always. We have to make off SY for our college exam, but have been told that we need to take braiding inside box and then crimp. My college is saying this is what is expected in the AM2. Has anyone done the AM2 recently and know which is the required way for it to be fixed?
@mfr58
@mfr58 Жыл бұрын
Not sure about AM2, but that's the way I do it and it's far less fiddly, cheaper and more secure than using those special glands.
@Alfie1178
@Alfie1178 Жыл бұрын
LAPP SKINTOP MS SC M are far more advanced glands for SY cable and are suitable for areas where spraying or splashing water is likely. They are my preference.
@paulpantsoff6584
@paulpantsoff6584 7 ай бұрын
I've seen many professional sparks make the same armoured shroud mistake. If you want your shrouds to have a wobbly cut then do it like this guy. If you want a more concentric and neater cut then push the uncut shroud over the cable in the wrong direction, then cut in a circular motion using the cable as a former, then fit the shroud in the correct direction. Laying it flat for the cut looks toilet.
@tonywatson1412
@tonywatson1412 2 жыл бұрын
dont project the banjo locking bolt too far into the c.unit.. brass nut with brass hex bolt easy to tighten say 15mm , in length..
@aaronrothwell9026
@aaronrothwell9026 2 жыл бұрын
I have just removed alot of this shite cable in a garden which the previous "spark" used to wire lights and sockets! He used the braid as an earth cause he found he did not have enough conductors to do what he wanted to, he terminated the braid in choc blocks in the back of the lights! The cable was undersized also giving massive earth fault loop readings. Needless to say the whole shite got ripped out and replaced with swa.
@GSHElectrical
@GSHElectrical 2 жыл бұрын
My learners need to make off SY flex as part of an assessment hence the video 👍🏻
@aaronrothwell9026
@aaronrothwell9026 2 жыл бұрын
@@GSHElectrical I appreciate the video, and it's a very good demonstration. The issue I have not with you but in general is the selection of equipment in general for the environment, I have seen this stuff in loads of gardens etc where it is not appropriate, yes it has its uses in industry, but it is not recognised by bs7671 as a previous comment stated. In my opinion its awful stuff and there are better alternatives in certain situations
@pjeaton58
@pjeaton58 6 ай бұрын
SY cable is shite - period.
@theavchap
@theavchap 2 жыл бұрын
It’s nice to see a CXT gland on some SY for a change. However, the only places I see it used are the exact same places it isn’t designed to be used. There are better alternatives with BS ratings.
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Remember we are a college 👍🏻
@jackninnu9719
@jackninnu9719 Жыл бұрын
King Gary
@HMGaming360
@HMGaming360 2 жыл бұрын
Where can I buy the lock nut spanner please?
@GSHElectrical
@GSHElectrical 2 жыл бұрын
I wish I could remember 🤦🏻‍♂️
@pjeaton58
@pjeaton58 6 ай бұрын
Use a large adjustable ????
@imranemushtaq1081
@imranemushtaq1081 2 жыл бұрын
Can sy be use for power and mains?
@jon47com
@jon47com 8 ай бұрын
No, the manufacturers state it is only for controls.
@o0li553
@o0li553 2 жыл бұрын
很好,在香港都是這做的,
@dennisphoenix1
@dennisphoenix1 2 жыл бұрын
I was told you couldn't use SY flex as it doesn't have a BS standard .
@GSHElectrical
@GSHElectrical 2 жыл бұрын
My learners have to install SY cable as part of an assessment hence the video 👍🏻
@dennisphoenix1
@dennisphoenix1 2 жыл бұрын
@@GSHElectrical is it correct that we can't use it in the UK because it's not got a BS standard, seeing as it's a European cable is there a harmonised standard ?
@makg4655
@makg4655 2 жыл бұрын
@@dennisphoenix1 & the braiding is not designed to carry voltage .. this video is so wrong . As it’s for U.K. STUDENTS.. he should be telling them it is not to be used in new installations or they are installing a fault.. PI** POOR PRACTICE
@Ste2023
@Ste2023 Жыл бұрын
It is was it is
@derekmorrison1973
@derekmorrison1973 Жыл бұрын
Got to then ask the question, why are products for SY cable still being manufactured for the UK market, if it is not allowed? I don't know but that's a reasonable question. SY not allowed on Ex installs but allowed in factories and commercial I think.
@andybaker6088
@andybaker6088 2 жыл бұрын
Those glands are crap, just use a standard SWA gland and flip the tapered olive upside down so it bites into the braiding and make it off live an SWA, saves time and both....these glands are crap!
@arcadia1701e
@arcadia1701e 2 жыл бұрын
Sy cable has no British standard, It shouldn't be used. Use rubber ho7rn cable instead.
@carlmarquardt994
@carlmarquardt994 2 жыл бұрын
Ok.decent tip. I just had to check a gas flare. Sy cable outside run on ground no cable tray. Looked up the ruling. Tbh I have used it on e or twice and didn't mind it...but rules are rules. Ta
@GSHElectrical
@GSHElectrical 2 жыл бұрын
It’s in the end assessment for my learners hence the video
@pirate69s
@pirate69s 2 жыл бұрын
100% Europen rubbish belongs in Europe!
@makg4655
@makg4655 2 жыл бұрын
@@GSHElectrical why are you not contacting the assessment body and telling them it shouldn’t be used except for control gear !!!!! How many other things are you teaching that is wrong .. but doing it because the computer says NO 🤔🤔😂😂
@007floppyboy
@007floppyboy 2 жыл бұрын
@@makg4655 SY can be used as supply cable (Low tension feed) I have asked all the manufactures and have their responses on file, its my insurance against owt going t1ts up. To be honest, after years of installing this stuff, Its fine. Carried out inspections on my designs in Nuclear plants and its still ok, after more than 20 odd years in service.
@tonywatson1412
@tonywatson1412 2 жыл бұрын
who would even bother with this stuff..when there are alternatives available...and are easier to terminate..
@GSHElectrical
@GSHElectrical 2 жыл бұрын
It’s part of a practical assessment my learners have to do hence the video
@havoctrousers
@havoctrousers 2 жыл бұрын
I've done electrics for a long time, and I did an apprenticeship many years ago. I was never taught SY and I've never used it. I can't help thinking for the exact same amount of work you might as well use SWA? It's tougher, better and you can use it outside and bury it etc. If you don't need that level of mechanical protection, then you might as well use NYY-J and stuffing glands and save yourself a little bit of faff. Also, I haven't used a banjo in years, those pirahna/earthing nuts are so much less hassle and save you compromising the IP rating of your enclosure.
@ominence5573
@ominence5573 2 жыл бұрын
Cl electrician scissors
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Sadly we a stuck with 10 basic tools in our college tool kits 👍🏻
@ominence5573
@ominence5573 2 жыл бұрын
@@GSHElectrical well you had 2 pairs of side cutters.. I think one pair could be dropped and replaced for the scissors.. they are really handy for stranded copper, like in this video :-)
@dead.format
@dead.format Жыл бұрын
No idea why this is taught on the courses. It just encourages thebuse of a sub standard cable
@GSHElectrical
@GSHElectrical Жыл бұрын
But we do have to teach it….
@jon47com
@jon47com 8 ай бұрын
I complained to NET about this, they said they included it because it was listed as an acceptable cable by City & Guilds despite the IET saying its use should be discouraged. Personally I think there are plenty of other types of cable that it would be more useful for apprentices to learn how to terminate especially those who will go into industrial work.
@stevenwalker3102
@stevenwalker3102 11 ай бұрын
I know this is the by the book way of doing it, but i really can't see a reason why you cant just use a stuffing gland and take the yarn strait to the cpc terminal inside the enclosure? This has always seemed pointless imo. I haven't used sy in the 10 years since doing my AM2 and I'm a commercial spark (Before I get the housebasher comment). The most pointless cable ever invented also.
@pjeaton58
@pjeaton58 6 ай бұрын
SY cable is rubbish and the braid strands are a finger piercing health & safety hazard !!
@007floppyboy
@007floppyboy 2 жыл бұрын
Those glands are simply the worst type of gland I have ever had the misfortune to use. I used them in the 80s, complete joke, and you expect them to improve, no they didnt. If you are thinking of using these stop, chuck em in the bin. Loads of other good glands out there, just like SWA E1W glands or similar, where they grab the flex all around with the olive. Also, if your doing any high frequency work, these glands dont meet latest EMC standards where as an E1W type does.
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Thanks for your feedback 👍🏻 these glands are the ones my learners are required to install as part of an assessment hence the video 👍🏻
@sachindas7937
@sachindas7937 2 жыл бұрын
Takes to much time, time is money
@GSHElectrical
@GSHElectrical 2 жыл бұрын
It’s a requirement for my learners assessment hence the video 👍🏻
快乐总是短暂的!😂 #搞笑夫妻 #爱美食爱生活 #搞笑达人
00:14
朱大帅and依美姐
Рет қаралды 14 МЛН
Lazy days…
00:24
Anwar Jibawi
Рет қаралды 8 МЛН
SY Cable is Not Armoured, Not for Outside Use
7:20
John Ward (jwflame)
Рет қаралды 40 М.
AM2 Assessments - DO's and DONT's ✍️
18:01
Scolmore Group
Рет қаралды 15 М.
AM2-S The Night Before
12:43
AdamDunlopElectrical
Рет қаралды 11 М.
How to Make Off an Armoured Cable - SWA
10:59
GSH Electrical
Рет қаралды 11 М.
How to Make off a SWA Gland | For Steel Wire Armoured Cable Installation
9:52
快乐总是短暂的!😂 #搞笑夫妻 #爱美食爱生活 #搞笑达人
00:14
朱大帅and依美姐
Рет қаралды 14 МЛН