@marcosnunes3052 Ай бұрын
A diferença é causada pelo trigger que dependendo do momento na curva senoidal o valor tambem altera! Por isso tem que Fazer 3 testes e extrair as medias!
@kermo8870
@kermo8870 5 ай бұрын
What brand circuit breaker is there ? I have seen with my own eye how Chint / Noark breaker is manipulating with tester giving different measurements ... Measured with FLUKE
@chok-d67
@chok-d67 6 ай бұрын
Does this brand of measuring instrument have a high error?
@computerbeschreibungen6758
@computerbeschreibungen6758 Жыл бұрын
Entweder dein gerät ist kaputt oder deine Leitungen sind uhr alt, den selben gerät habe ich auch und funktioniert tiptop
@joeramos7973
@joeramos7973 2 жыл бұрын
all the grounds of the building are linked and that creates alterations in the measurement, perhaps it would be better to measure on the same copper rod from the well to the ground (it is just an idea). Have you seen the UNI-T Multifunction Tester instrument UT595?? will it be more reliable?. Saludos!!
@bernhardneuner1282
@bernhardneuner1282 2 жыл бұрын
Hi, no - at the same socket the measurement must be the same. E.g. for 300mA and 500mA the results must be the same by ohmic law. This tester always shows 0 Ohm if you set 300mA test-current. See my other video than you know what I mean.... ;-)
@joeramos7973
@joeramos7973 2 жыл бұрын
@@bernhardneuner1282 uhm ok if I saw the video you mention, the equipment is not accurate, is there something that measures the equipment well, or all the functions are wrong
@flolandshut
@flolandshut 9 ай бұрын
Loop resistance is not really measured, its calculated! So it will differ even at the same socket. Belongs to voltage, loads nearby and so on!
@ช่างไฟไทยแลนด์1985
@ช่างไฟไทยแลนด์1985 6 ай бұрын
This brand of measuring instrument Measure loop impedance Is it reliable? Why are the measured values not the same?
@Menshinin
@Menshinin 2 жыл бұрын
Возможно, не должно быть других работающих потребителей в сети во время измерения.
@НиколайВикторович-ц4н
@НиколайВикторович-ц4н Жыл бұрын
Скажите,это ведь измерение петли фаза-ноль?Или я ошибаюсь?
@Menshinin
@Menshinin Жыл бұрын
@@НиколайВикторович-ц4н теоретически да, но на практике эти приборы ничего интересного в этом аспекте не измеряют. Вот УЗО они тестируют очень хорошо.
@OhmJunkie
@OhmJunkie 8 ай бұрын
​@@НиколайВикторович-ц4нда, но очень корявое 😅
@efanutz
@efanutz 2 жыл бұрын
you pay 150 euro and the result is the same, cheap china part ! i think about to buy one of this for myself too :) ... the price is too good not to try
@bernhardneuner1282
@bernhardneuner1282 2 жыл бұрын
I paid 107 euro but this was to much! The results are unreliable! The 300mA Range shows always 0Ohm.... 500mA Shows 4.9Ohm... so what now?... (another measurements at one socket with 500mA RCD, see other video).
@fabienchereault1883
@fabienchereault1883 2 жыл бұрын
The result is certainly correct the loop resistance always varies a little bit especially on values ​​as close to 0
@bernhardneuner1282
@bernhardneuner1282 2 жыл бұрын
Yes round about 0 Ohm would be nice - but I had measured on the same socket 0.0 Ohm and 4.8 Ohm - and this is not correct. The 300mA-Range of this device always show 0 Ohm.... I had to be below 1.9 Ohm - and with this tester there is no reliable results!
@computerbeschreibungen6758
@computerbeschreibungen6758 Жыл бұрын
So ein fehler passiert auch mit Profis Messgeräte 😉
@flolandshut
@flolandshut 9 ай бұрын
Ganz normal das es keine Messung sondern ein errechneter Wert ist
15 апреля 2024 г.
8:35
Максим Вакулен
Рет қаралды 1,4 М.
Habotest HT5910
3:59
Petr Orság
Рет қаралды 22 М.
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
We Attempted The Impossible 😱
00:54
Topper Guild
Рет қаралды 56 МЛН
To Brawl AND BEYOND!
00:51
Brawl Stars
Рет қаралды 17 МЛН
🔴 Aneng MH13 Insulation Resistance Tester Review - No.1170
23:00
Defpom's Electronics Repair
Рет қаралды 22 М.
Pomiary Tanie Mierniki UNIT 595 i 522
31:16
Bartek Elektryk
Рет қаралды 87 М.
HABOTEST HT5910 misst fehlerhaft!
4:16
Bernhard Neuner
Рет қаралды 9 М.
MS 5910 slow mode
3:25
Pavel Žiška
Рет қаралды 9 М.