thanks for making another great video. area where i live has high sulphur pollution and it attacks any phosphorus fluxed braze joint. after watching your excellent video about "brazing vs solder" I've used staybrite 8 and 56% silver solder on R410a system. they've worked beautifully and is still going strong against sulphur corrosion. i know many "know it all" HVAC technicians frown upon silver solder but in my case it worked really great. keep making awesome and informative videos like this in the future.
@Halligan142
@Halligan142 2 жыл бұрын
Interesting. Never knew that was an issue. Only thing I've seen close to that around here is on ground level condensing units and it's from dogs pissing on the units.
@popsmccartney435
@popsmccartney435 2 жыл бұрын
Thanks for the video/ Used Stay Brite 8 for years, retired now.
@reginahall4500
@reginahall4500 2 жыл бұрын
I agree, I have been using stay brite for 40 years, we used it in the Navy too. it's all about the quality of the installation. we have a 20 year old ac system, 50 ton developing leaks at brazed joints (1 3/8") we do braze at 1 1/8" and up due to the fittings are usually too loose, we have replaced 25 year old systems that we installed and were still running with original compressors. The proof is in experience. Most engineers and manufacturers engineers have never been in the field or held a torch. Yesterday we repaired a cracked 3/8 factory turn due to annealing, we have 2 Lennox units 10 ton compressors with spilt 1/2" lines at the discharge - wonder why? Brazing is not the end all, it's mostly for lazy techs. Most don't purge or clean the fittings, but the rest of us are supposed to follow there lead? Its' also laziness on the manufacturers part because they don't any field research. still living in the 1950's.
@Halligan142
@Halligan142 2 жыл бұрын
Yeah most people who have badmouthed it or given me grief about using Stay Brite have never actually used it themselves. The most common argument I hear is the joints will not hold up in a building fire. While yes that may be true, all the new crimp style fittings use an O-ring to seal. Those won't hold up in a fire either. Those Lennox units are notorious for cracking right at the compressor discharge 90. It goes from 3/8 into 1/2, but it's inserted into the tube instead of a normal fitting that goes around the outside. Makes that section weak and that discharge line is completely unsupported. Vibration work hardens it. The older LGA units were also notorious for the discharge lines rubbing out against the vertical wall where the tubing goes up to go across the blower section. We remove the factory clamps and add a piece of armorflex then clamp on the outside of the armorflex. Prevents that issue.
@ccthepope
@ccthepope 2 жыл бұрын
Great video!
@GlenS123
@GlenS123 2 жыл бұрын
Nothing wrong with Stay-Brite #8, if tech's were to take the time to read the spec's they would agree with you.
@Halligan142
@Halligan142 2 жыл бұрын
Did a whole video on it where I pulled the actual product specs and I still got crap. The most logical argument I've gotten is it melting during a fire, but zoomlock fittings have a rubber o-ring to seal and those zoomlock shark bite style things use a plastic insert. Those will melt too.
@OnePointLander
@OnePointLander 2 жыл бұрын
Have you ever had a problem with flux/acid in the system years later?
@Halligan142
@Halligan142 2 жыл бұрын
Never had an issue if you use the correct amount and put it only on the tubing and not in the fitting. I did a video a while back where I soft soldered and brazed joints and cut them apart to see the inside. No flux intrusion. You can skim to those parts in this vid. kzbin.info/www/bejne/rXunaGRoeadpiZI
@OnePointLander
@OnePointLander 2 жыл бұрын
@@Halligan142 Thanks! Yeap seen that video a few times hah. I do the same thing, male end and lightly apply. Just curious since you have done so many. Thanks for the upload!
@AndrewPrice2704
@AndrewPrice2704 2 жыл бұрын
What is the green spot on the sight glass for? :)
@Halligan142
@Halligan142 2 жыл бұрын
Moisture indicator. Green = dry yellow= moisture present. Alco brand is purple and pink. Intense heat like overheating during brazing will also make it permanently yellow so as can age when exposed to sunlight so it's not a 100% accurate system.
Another Day in the Life of an HVAC Tech: Episode 21
18:40
Halligan142
Рет қаралды 1 М.
The Cooler Job Part 1: Another Day In The Life Of An HVAC Tech
28:35
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН
Cat mode and a glass of water #family #humor #fun
00:22
Kotiki_Z
Рет қаралды 42 МЛН
She made herself an ear of corn from his marmalade candies🌽🌽🌽
00:38
Valja & Maxim Family
Рет қаралды 18 МЛН
HVAC Silver Soldering vs Brazing vs Brazing While Flowing Nitrogen!
18:42
AC Service Tech LLC
Рет қаралды 182 М.
Refrigeration Cycle 101
10:36
HVAC School
Рет қаралды 869 М.
Another Day in the Life of an HVAC Tech: Episode 24
32:28
Halligan142
Рет қаралды 2,6 М.
Fixed Copeland Scroll
11:00
Don Gillis
Рет қаралды 1,4 М.
Heat and Walk-in Freezer Not Working
27:25
Halligan142
Рет қаралды 1,2 М.
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,9 МЛН
Explaining Superheat and Subcooling to Your Apprentice!
14:14
AC Service Tech LLC
Рет қаралды 654 М.
Day In The Life - Commercial HVAC Technician
27:30
HVAC For LIFE
Рет қаралды 9 М.
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН