This subfloor will last forever....kudos to the builders.
@Duke-sj8oc3 жыл бұрын
Made in Germany - Saubere Arbeit 👍
@gringo82413 жыл бұрын
Yes, I can see that is Germany quality My English is not the best, for my defense Statistical minimum for steel mesh is 40 cm, but what I see here is 20-25 And you are not use vibrator for concrete That must be very quality🤦♂️
@patricktlee3 жыл бұрын
The Steel Mesh is 15cm and we are using a Vibrator for the concrete😊
@salkosuvalic3776 Жыл бұрын
@@gringo8241 besser gucken
@muteallchat5829 ай бұрын
@@patricktlee Good afternoon, and what is used in the pillow under the monolith? Sand?Rubble?what is the depth of the pillow?is it necessary to insulate the monolith from below?
@patricktlee9 ай бұрын
@@muteallchat582 it is gravel, about 35 cm. You can insulate from the bottum or top, i recommend installing it underneath😊 greetings Lee
@MatzeMaulwurf2 жыл бұрын
Hallo, was wurde bei 1:30 zwischen das Schutzrohr und das KG-Rohr verfüllt? Weswegen überhaupt das Schutzrohr? Hier bei uns (Südniederdschsen) ist das unüblich. KG2000 und dann „direkt“ durch die Platte. Danke für die schöne Dokumentation.
@pan34113 жыл бұрын
Geile Musik - - -schön gemacht - - -
@patricktlee3 жыл бұрын
Danke dir ☺️
@AndiBauIT Жыл бұрын
Top Arbeit 👍
@daskasspatzle23963 жыл бұрын
Hübscher Zeitraffer :-)
@CC-jb4ey Жыл бұрын
Können Sie bitte mitteilen, mit welchem min. Abstand ist unterliegende Rohre zum Unterkante der Sauberkeitsschicht verbaut? Falls Bodenplatte tiefer als Grundwasserspiegel liegt, werden die Leitungen auch unter der Bodenplatte gebaut werden können?
@pmajluf103 жыл бұрын
Amazing video, thank you!
@nickforst90113 жыл бұрын
Cooles Video 👍👍
@andymora55952 жыл бұрын
Wie würden sie als Profi kostengünstig einen Kellerboden in einem Altbau (Baujahr 1960) wieder aufbauen? Meinen Werkstattboden würde ich gerne erneuern. Aushub sind aktuell 15cm. Darunter befindet sich eine ca. 5 bis 10cm Schotterschicht. Geplanter Wiederaufbau: Oberfläche exakt einebnen mit Sand. Bitumenschweißbahnen verlegen und verschweißen, seitlich bis zur alten Horizontalsperre hochziehen. XPS-Platten mit 4cm Stärke verlegen. Darüber Folie und seitlich hochziehen. Betonboden 11cm gießen, mit Stahlmatten verstärken. Wäre das so denkbar oder bricht alles nach paar Wochen zusammen? :)
@patricktlee2 жыл бұрын
Naja hört sich alles nicht schlecht an, bis auf die Schweißbahn unterhalb der Bodenplatte. Wieso unterhalb?
@andymora55952 жыл бұрын
@@patricktlee Mit der Schweißbahn war nur eine Idee dass auch keine Feuchtigkeit zwischen den Xps Platten hochzieht. Ich denke nun ich lasse die schweißbahn weg. Durch eine 0,2 mm dicke Folie kann ja auch kein Wasser durch
@patricktlee2 жыл бұрын
Also wir legen auf der Schotterschicht PE-Folie aus, betonieren eine Sauberkeitsschicht, legen die Dämmung aus, bewehren und betonieren die Bodenplatte und dichten dann diese ab
@andymora55952 жыл бұрын
@@patricktlee Danke für die Infos! Da ich nur 15cm zur Verfügung habe , bin ich am überlegen ob 12cm beton und 3cm Xps oder 11cm beton und 4cm xps. Was bringt mehr, 1cm mehr beton deutlich mehr Stabilität oder 1cm mehr dämmung höhere Bodentemperatur ... ?
@sabanbostan13202 жыл бұрын
beste haus
@kazemamin28552 жыл бұрын
thank you
@love.wildly.live.fearlessly3 жыл бұрын
What was it for? I speak English and was waiting the whole time to figure out what it was for but they just left it as a big slab.
@patricktlee3 жыл бұрын
It was for a house
@ZaZa-sm4ck7 ай бұрын
ÄH Hallo? Und was ist mit dem Schotter unter der Folie? Brauchst den heute nimmer??🤔🤔🤔
@patricktlee7 ай бұрын
??? Was brauch ich nicht mehr???🤨
@Bird223 жыл бұрын
At exactly 2:31, a worker leaves what is unmistakably a beer bottle sitting on one of those vertical PVC stacks. It IS Germany I suppose.
@patricktlee3 жыл бұрын
Of course, Bamberg, Germany 😊
@sergioluevano92293 жыл бұрын
🍻
@agah20673 жыл бұрын
👍😁
@sisandor10 ай бұрын
wofür die Rohre die dann einbetoniert werden in der Platte?
@patricktlee10 ай бұрын
Das sind die Grundleitungen für alle Abläufe im Haus (Toiletten, Dusche, Waschbecken, Küche etc.)
@sisandor10 ай бұрын
ja aber die sind doch unter der platte jetzt? @@patricktlee
@patricktlee10 ай бұрын
@@sisandor ja, wo sollten sie sonst sein?🤔
@sisandor10 ай бұрын
ok ich sehs gerade. die werden dann freigelegt. Wieso macht man die Rohre nicht 10cm länger damit sie aus der Bodenplatte rausstehen und so einfacher zu erreichen sind? und danke für deine Antworten - super Video!@@patricktlee
@andymora55952 жыл бұрын
Ich dachte es müsste eine mind. 12cm dicke Dämmung unter die Bodenplatte ? Weshalb ist dies hier nicht nötig gewesen?
@patricktlee2 жыл бұрын
Der Keller hier wird oberhalb der Bodenplatte gedämmt bspw. Eine Fußbodenheizung verlegt und es wäre nur nötig im Frostberührten Bereich, also wenn ohne Keller gebaut wird.
@ReactionTV2023 Жыл бұрын
@@patricktlee Hallo eine Frage: Bei mir altes Landhaus, Boden als Balkenkonstruktion. Darunter Dachpappe auf Sand. Nach 10cm Lehmboden. Ziegel-Fundament reicht 65cm tief von der Sandebene gemessen. Grundwasser liegt 1,5 Meter unter der Sandfläche. Ich möchte die Böden vor aufsteigender Feuchtigkeit schützen und Wärmedammen als Abschluss Bodenheizung. Ist folgender Aufbau sinnvoll? Pe-Schutzfolie Styrodur-Platten Boden Dehnungsstreifen an den Wänden zur Kontaktvermeidung Stahlmatten-Armierung etc. Schweißbahn auf fertiger Bodenplatte Isolierung für Bodenheizung Bodenheizung und Estrich Fertig. Ich überlege bevor die Bodenplatte angegangen wird unter dem Haus 2 Drainagerohre gegen Grundwasser durchzulegen, welche im Garten in den Fäkalientank ableiten, dieser ist mit einer Pumpe zum öffentlichen Abwassersystem verbunden.
@dedek2222 жыл бұрын
warum die erste betonschicht.?
@patricktlee2 жыл бұрын
Das ist eine Sauberkeitsschicht, um den flächendeckenden Abstand der Bewehrung zu gewährleisten