Programming an LAE AT2-5 Digital Controller

  Рет қаралды 155,774

Hawco

Hawco

Күн бұрын

Learn how to configure an AT2-5 digital controller from LAE Electronic. This controller features three relays, which are often set to run fans, a compressor and a defrost control schedule.
This video explains the main programming parameters for this controller, including how to set the third or auxiliary relay for a defrost schedule. This includes how to set the defrost type, frequency, end temperature, drip time and duration.
Other configuration settings include set point temperature and limits, compressor settings, fan settings, door alarms and light controls.
Got a question about programming an LAE controller? We can help. Contact our technical support team on +44 (0)1483 869 069 or email technical@hawco.co.uk.
Find a manual for the LAE AT2-5 and other LAE digital controllers at www.hawco.co.u...

Пікірлер: 9
@amoomere9548
@amoomere9548 5 жыл бұрын
Thank you
@miodragnedic378
@miodragnedic378 4 жыл бұрын
Thanks a lot. Big help.
@liamp5
@liamp5 5 жыл бұрын
Excellent thankyou :)
@mohamedkamel1611
@mohamedkamel1611 4 жыл бұрын
How can set the thermostat at a temperature of 37.5 ...I can't set the temperature to a comma
@HawcoCoUk
@HawcoCoUk 4 жыл бұрын
Hi Mohamed The parameter you want is SCL. With SCL set to “2: This means that a decimal point is not present (ie “20 deg c”) With SCL set to “1”: This means that a decimal point is present. This now means that what was once “20 deg c is now 2.0 deg c” However, if you ever change the SCL parameter from “2” to “1” (or vice versa) please ensure you check all the parameters as they will all be affected - ie HYS (hysteresis) was “05 deg c” is now “0.5 deg c” automatically!! Hope that makes sense. The Hawco team
@mohamedkamel1611
@mohamedkamel1611 4 жыл бұрын
@@HawcoCoUk..Thank you very much for your reply- I understand that if I put HYS at 1.0 and SP at 38 ° C this might give me an average temperature of about 37.5 ° C
@HawcoCoUk
@HawcoCoUk 4 жыл бұрын
Dear Mohamed Setting HYS to “1.0” is too small a tolerance for the controller and probe to read unless you are using a K-type / J-type thermocouple. If you are using an NTC or PTC thermistor, you should increase HYS to at least “2.0”. Hope that helps. The Hawco team
@FilmesLaranjeiro
@FilmesLaranjeiro 4 жыл бұрын
Hi Hawco. I was wandering is there a controller capable of defrosting triggered by evaporator temperature...I'm thinking water heating for radiant floor...
@HawcoCoUk
@HawcoCoUk 4 жыл бұрын
Hi Antonio It depends on the temperature you are hoping to achieve but you can set a LAE AT2-5 controller to switch off by either time or by temperature, whichever is reached first. For example, the two parameters you would need are: The DLI parameter which controls the defrost end temperature The DTO parameter which controls the maximum defrosting duration If you need any further advice on a specific application, email technical@hawco.co.uk and we will try to help you. The Hawco Team
Fixing An E1 Probe Fault: LAE AT2 5 Digital Controller
1:19
Harley Quinn's revenge plan!!!#Harley Quinn #joker
00:59
Harley Quinn with the Joker
Рет қаралды 27 МЛН
Please Help Barry Choose His Real Son
00:23
Garri Creative
Рет қаралды 22 МЛН
Кадр сыртындағы қызықтар | Келінжан
00:16
LAE BIT25 controller Defrost settings on Global VGLD52 Party Case1
3:57
Programming an LAE AC1-5 Digital Controller
9:16
Hawco
Рет қаралды 30 М.
20190415 194209
3:52
Bo Ford
Рет қаралды 89 М.
True sollatek temp controller replacement
10:07
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 18 М.
How to win a argument
9:28
ajaxkmr
Рет қаралды 472 М.
Emerson™ Electronic Defrost Control
7:28
Copeland
Рет қаралды 171 М.
Новый фонарик в iPhone с iOS 18
0:49
Wylsacom
Рет қаралды 641 М.
Худший iPhone 16. #apple #iphone
1:01
Не шарю!
Рет қаралды 288 М.
Тест Ryzen AI 9 HX 370 и графики 890m
27:29
PRO Hi-Tech
Рет қаралды 39 М.
POV: You Find a 🗑️ Full of iPhones ⭐
0:13
Shakeuptech
Рет қаралды 1,5 МЛН