Great video! It would be great if you can also make a video on sending and receiving data from other controllers (which are not from Siemens). Like sharing data with a robot. Thanks!
@nasonmutale2937 Жыл бұрын
Great video ,thanks . Your videos are really helpful for a beginner like me.
@zhengkunyan80014 жыл бұрын
hello guys, some more hints from YAN, if you wanna get code from plc and upload to your PC. You must pre-installed the GSD file which used by the project in PLC (if no GSD, no need). Second, you need same version of TIA portal which is utilized to program the PLC. Otherwise you can’t get the code.😘
@EHSANCHAHARMAHALI11 ай бұрын
You are the king🎉🎉🎉
@Resonant875 жыл бұрын
Great content! Pumping out new organization of videos helps. Although I think there some basics missing that might make good tutorials. How to use outputs for PWM, PTO, frequency, etc...
@hegamurl74345 жыл бұрын
Thanks for the feedback! I have a long list with video ideas and will put yours on it!
@nandarora13034 жыл бұрын
Looking forward to a video on PWM or frequency!
@saifrehman74135 жыл бұрын
So so helpful. Keep sharing more videos. Many thanks
@muhammadkhalid83745 жыл бұрын
Great things thanks a lot of
@fverboven2 жыл бұрын
Great , very usefull and very clear explained ,,, top :)
@electronicinfrared832922 күн бұрын
Hi I want to upload program from PLC to PC but upload button off saying about gsd files ..what to do
@oguzsahinn4 жыл бұрын
We have wago io modules and used gsd files. Very useful system.
@mahandhiraselvant90227 ай бұрын
Hey phili can you please show how to change the as per our requirement I/O tag number to change in gsd file inside
@sodhakishansinh94784 жыл бұрын
Sir Very good explanation 👍
@sarahlabidi6558 Жыл бұрын
Great, thank you for sharing
@anoop22march5 жыл бұрын
Sir please make video on DP/DA couplers, How to check profibus cable.
@khadarbabamohammad82812 жыл бұрын
Great, thank you for sharing the information
@christian_t79542 жыл бұрын
Thanks dude you are incredible !
@danielg.j.20997 ай бұрын
Hi, Sorry if this is not the video where this question goes. I have a DL100 laser position device and for now I could conect and get distance and speed but I need to configure from PLC to de device and I don't know how to do it. Do you have any example of this? I do really appreciate your help.
@amaohabeeb912211 ай бұрын
Hi Do i need a gsd file to create a profibus communication between siemens plc cpu and siemens Interface module using tia portal.
@JM-wc3gw3 жыл бұрын
Thank you for this Video. How about a generator set which has a Mitsubishi control panel can I apply this thing?
@framos9991 Жыл бұрын
Helpful.Thank you!
@thierrymeuris80422 жыл бұрын
Anothe great video! Do you also have a video on how to e.g. write or read a bit from a decentral I/O module trough Profinet? I'd like to see how the adressing stuff works!! Thanks! Keep up the great work!
@theboringchannel67212 жыл бұрын
Great video. Thank you sir
@trolingmaster232 жыл бұрын
Hi! Can you help me? I'm using a weighing module with profinet GSD, the manufacturer tells that the weighing signal is 16 bit. I originally used UDInt so that's 32 bits if I remember correctly. It worked king of ok because I didn't noticed the length, because I was following another manufacturer tutorial and for them it was 32 bit. On Monday I'm going back to check if the 16 bit approach worked. The question is, how are inputs managed? I can work with a normal " %IW100" for example? Or should them be input as peripheral ? " :P%IW100 " I need it to work. The first time I used the module I only had one scale, but this time is 2 scales which the module is capable of, the thing is that the bits may overlap if I don't use them correctly, it's 16 bits for one signal and then the next immediate 16 bits for another
@matthias84704 жыл бұрын
Genius. Helpful genius.
@hegamurl74345 жыл бұрын
First Comment!
@lavousee3 жыл бұрын
Hello, I cannot find the file sinamics 20171106.xml on the siemens GSD website. what is he supposed to do? it won't allow me to download the program from PLC ...
@bilalfarih34492 жыл бұрын
Hello thank you for your videos, i have one question, i installed the GSDML of one device in TIA PORTAL V16 and the installation normally was successful, but when i look in hardware catalog, this device doesn't appears. what can is the problem?
@rafm1019934 жыл бұрын
Hi! Can you make a video on Danfoss FC302 VFD profibus GSD installation and how to program it (Start/Stop/Rever/Speed Reference) in TIA if possible?
@divyeshmali49584 жыл бұрын
informativ. 👍
@zhengkunyan80014 жыл бұрын
May I ask a question, I build the modbus communication between Rockwell plc and S7-410smart by using CP modules (my real experience), but I don’t need GSD file. So if I have GSD file installed, no need configure the communication (including use PSend PReceive block?)
@luzvic27174 жыл бұрын
I HAVE A DOUBT. IF I WANT TO MAKE A BACKUP? WHAT SHOULD I DO? I HAVE SEVEN FESTO MODULES AND ONE WEIDMULLER MODULE. REGARDS AND THANKS.
@glebonly46604 жыл бұрын
Hello. Please make a video about communication of siemens plc and product of another manufactor. maybe "RDREC" "WRREC" functions.
@anoop22march5 жыл бұрын
Sir please video software fault occur in Simatics manager and TIA portal like Communication, hardware ,how to diagnosis them
@mortezarahimi67845 жыл бұрын
hi Phillipe. please make some tutorials on LAD programming with both digital i/o and analog i/o. at least in a series videos from beginning to the end. from hardware selection and tag creation to the HMI control. having for example all the topics you have mentioned (OBs, Timers, counters, flipfliops and PID controller.) that video ALONE would be the best Source for TIA Portal in the whole Internet, Please!!! ☺☺😊🙏🙏
@zhengkunyan80014 жыл бұрын
I mean if I have GSD files, the two devices can set up their communication directly? (Can read data directly by entering the address?)No need any other configurations?
@surendra198019803 жыл бұрын
thanks for video
@JinsonKurianVJames5 жыл бұрын
Nice. Very useful. I have tried some stuffs like this with P&F absolute encoder to measure leg length of jack up rigs. One thing I suggest to add in part 2 video that is "Telegram" . How could we use standard or siemens telegram to get input and transfer output to the other device like encoder or Vfd? Also with example, how does these telegram Dint data value work on external devices like encoder or Vfd?
@TheMusabsaleh855 жыл бұрын
Is there a FC or FB that comes with gsd file which I can use it to make the control of this device easier?
@sovonbhattacharya44103 жыл бұрын
How to Import LGF File In TIA PORTAL
@aouartamohammed25344 жыл бұрын
Great video
@hibra55704 жыл бұрын
How can I get your course?
@jees__antony2 жыл бұрын
thanks
@مصطفیغلامی-م7ن2 жыл бұрын
Hello I am Mostafa Gholami engineer electrical I need a download qsd file INOVANCE servo drive Can are you help me
@dennisrubio2375 Жыл бұрын
great
@christiandimelow92745 жыл бұрын
Nice video
@hegamurl74345 жыл бұрын
Thanks! Great... now my "First Comment!" - comment is actually not true, because you were faster by 7 seconds!😅
@christiandimelow92745 жыл бұрын
Haha, sorry about that 🤣
@dukenuke26905 жыл бұрын
lol, you guys have problems ..
@christiandimelow92745 жыл бұрын
Do you plan on making any videos involving I/O link?
@fonso_84164 жыл бұрын
Hi all! Great video Hegamurl! Anyone knows the difference between HSP y GSD? Thanks in advance :)
@ginnorenzo4 жыл бұрын
Hello, It's possible export GSD that it's in my project, How do I do?
@hegamurl74344 жыл бұрын
If you save your project and open it on any other PC that does not have it, it should be automatically installed by tia portal
@ashoksham86405 жыл бұрын
Make a sample program on field devices using GSD files
@beautyofislam3234 жыл бұрын
nice sir
@sabermrz87593 жыл бұрын
👍
@saeed2tube5 жыл бұрын
Festo made interesting robot.😉
@hegamurl74345 жыл бұрын
They make many interesting robots, I like the flying ones, they look so elegant and simple