You are the best online tutor I have ever seen and thanks for great work
@chidoziriiroh9329 Жыл бұрын
Thanks a lot, Hegamurl. Your videos are straight to the point and very helpful.
@yacinesafsaf99024 жыл бұрын
Thanks for the explication please make a video about migration from TIA V13 TO TIA 15
@gerry66913 жыл бұрын
to get to v14, or v15 and above you need to convert the project done in v13 with V13 SP1 first.
@davidcunningham8318 Жыл бұрын
You're a smart man, Hegamurl. Thanks for the video.
@anoop22march4 жыл бұрын
Thank you sir, please make video V13 to V15 migration
@johnhajdu42763 жыл бұрын
There is a lot of problem during the migration. Of course it depends on the system. If you "Just" migrate a project from Manager to TIA, that is not that bad. If you also change the CPU from 31x or 400 to 1500, it makes more and more problems. Just doing the migration makes the Graphs unusable. It is better if you do the project from the start up.
@hegamurl74343 жыл бұрын
Of course, upgrading a real project is not as simple as shown here... there are MANY obstacles. There are whole Siemens Teams that don't do anything else then upgrading, a huge business!
@berinderazvan79094 жыл бұрын
Greetings from Romania many Thanks and you are so GREAT.
@nightking9615 Жыл бұрын
So, if I have a S7 300 PLC "not supported by TIA", and I choosed not to click on that box, will the projects written in the PLC appear in TIA?, and can they be modifiable?
@Vozzhd4 жыл бұрын
Wow, looks great. But when I think about having to do this one day, I get scared. Can you talk something about tag migration? Few days ago I migrate tags by "proxy device" and by "Tag converter" as another way. Can you say, what is more effective? I love device proxy, because I have all tags in my WinCC project in different DB those was added in created device proxy directory. Tag converter load all in device tag table, that's not comfortable with huge data. But some people says, that they have bad experience with device proxy method. When you have 20000+ tags from several PLC you cannot check all of this manually. Love your videos, you know that))) P.S. Siemens Industry support site crash for 3 hours, when I want to download Tia converter last time xD
@habibrehman78204 жыл бұрын
great..Can you make video about VFD programming in TIA
@omarvalencia88634 жыл бұрын
This so nice and clean i wonder if all this is part of Device proxy, can´t find anything about it
@lawrencearguedo23864 жыл бұрын
hello phil. thanks for the vids.. really helps give some insights.. can you also do safety PLC programming with TIA portal? thankx
@framos9991 Жыл бұрын
Thank You! Very Helpful!
@chidoziriiroh9329 Жыл бұрын
Please do you have any video that thought about controlling induction motors using VSD through S7 PLC. I would be glad to go through it. Thanks.
@ВадимПешков-ь7ж4 жыл бұрын
Thank you a lot. I have a wincc project as well. Can I migrate it to TIA Portal too, to join it to related S7 project?
@hegamurl74344 жыл бұрын
Very good question, I've actually never tried to but am pretty sure that it is possible. I'll try it out some time!
@91peppec4 жыл бұрын
You are the best...thank you very much for your videos ... I hope one day to become as good as you. xD
@hegamurl74344 жыл бұрын
"Skill comes with practice" young padawan 😄 I was actually pretty bad when I started ~10 years ago
@91peppec4 жыл бұрын
@@hegamurl7434 Thanks xD I know. At the moment I work in the energy sector and there is a lot to learn (protocols, standards, devices ...). I also started studying RTUs (with ABB). I will try to commit myself and improve more and more and find my force. And you helped me a lot.
@pierpaolodini39582 жыл бұрын
Hello! First of all, thank you for sharing your precious work! I have just a question. It is possible to do the inverse process? I mean if it is possible to create a project in the tia portal which is compliant with a Simatic manager environment. Thank you in advance.
@garidze13 жыл бұрын
Do you have a link for SIMATIC MANAGER download?
@braincrackz4 жыл бұрын
It helps me alot. You are the best. May i know what is the meaning of SPS?because you share with us about why its called step 7. Thank you
@АндрейСидоров-ц3ж4 жыл бұрын
Speicherprogrammierbare steuerung, erste link im google.
@abdallahghariani34893 жыл бұрын
Thanks Mr. for all theses great videos. I want to ask you if it is possible to program with step7 a hardware (S7300) initialy configured with Tia Portal
@chandrashekhartippannabell62382 жыл бұрын
Hi. Nice online information. Is it possible to tell The version of Step 7 and Wincc Flexible 2008 software is possible to migrate to TIA Portal. Again here which is the best version of TIA portal need to use?
@ramkumarviswanathan70284 жыл бұрын
Hi, many s7 programs /wincc cannot be migrated directly to TIA V15 which requires first convert to TIA v13 then to TIA V15., which very difficult also lot of Errors generated during migration ,some commands are not actually migrated some data type error and so on....
@hegamurl74344 жыл бұрын
You are completely correct, the migration process is not perfect and there can be a lot of errors. But the general process is as described (which works pretty okay-ish). As for the V13: Theoretically correct, but I have forgotten to address that in the video! You don't need to migrate projects to V13. If you can not convert the wanted project to V15 directly, you can simply install V13 on the same machine (it's free and you don't need a license). V15 will recognize that V13 is installed and "use" V13 passively (without you noticing) to directly migrate to V15. That's how I do it! (I have V13,V14,V15,V15.1,V16 all installed side by side on my PC)
@CosminRusu1544 жыл бұрын
Thank you!!
@chaseyourapp2 жыл бұрын
Hello First of all thank you so much it's help me alot, but I have question if I have project at TIA is there any way to open it at simatic manager Thanks
@عبدالسلاممحمد-ق5ر2 жыл бұрын
i have CPU 400 programmed with siamtic manege and i have Tia portal on my PC i think i have to install siamtic maneger to upload project and then use migration to open it with Tia portal
@henrikespedal46654 жыл бұрын
Hello, great vid. Is i possible to do the other way round? I have a TIA project, is it possible to open this in Simatic Manager?
@yanuarwibisono26044 жыл бұрын
What should i do when I am facing error like attachment file this one The project to be migrated is not consistent. "DB101" needs to be recompiled. 5:49:27 PM FB51: The interface of FC2 is out of date. 5:49:27 PM DB101: The interface of FB1 is out of date. 5:49:27 PM The project to be migrated is not consistent. "S7 Program(1)" needs to be recompiled. 5:49:27 PM
@ATOMACH3 жыл бұрын
Thank you
@venkatesan81412 жыл бұрын
I was try simatic to Tia portal v14 migration, it's complete. After upload the PLC it's also ok but online monitoring time compile that block was error show again download it's clear, again compile same error show , this problem repeat again and again. What will do sir
@inhtan30804 жыл бұрын
Hi Mr: Hegamurl. I want migration block privacy simatic manager s7 to TIA PORTAL? When I migration error (FC block privacy password) Out off date. I have check block consistency
@luisadan529 Жыл бұрын
Hi all, I'm having problems trying to migrate from S7 5.5 to TIA v11 with below errors. Can you please help me? 0039:000010
@annyvivas2 жыл бұрын
Hi! Nice tutorial! I'm trying to migrate an existing program from Step7 to TIA. I have this problem: the code has been made on LIST configuration so i have some lines that TIA doesn't migrate correctly. On STEP 7 i have this kind of lines: UN #IN4 = L 3.2. On TIA portal i have an error because after migration this code line is traduces like this: UN #IN4 = %L3.2 and this adresse isn't assigned for a variable. How you can traduce the use of temporary L Stack on TIA portal? Thanks in advance i hope my question is clear enought
@sandeep14234 жыл бұрын
Hii sir.. Does S7 400( pcs7 ) works on Tia portal? ?
@hegamurl74344 жыл бұрын
Generally yes, but not all of them. The best thing is to inform yourself first (simply googling it) if your S7-400 is available in TIA Portal. (I know there is a special software tool for it, but I forgot the name)
@syeddanishraza9033 ай бұрын
Hi please help me out to license free simatic manager or tia portal?
@ChrisChristou2 жыл бұрын
If someone wants to migrate WinCC flex to TIA is it necessary to have Flex installed like with STEP7?
@John_Chiotis4 жыл бұрын
Hi and thanks for the videos. Someone give me a compact cpu 314C-2 DP .I want to use it in home for hobby/education. How can i communicate that with my laptop? With MPI USB converter?
@yoghurtedchikenpneumatics7493 жыл бұрын
PLCEMPEROR
@premnathk20444 жыл бұрын
i am using s7-400 plc and tp1200 hmi. I want to use the smartserver for remote access of the hmi. how to do? without TIA portal will it work? orelse if i migrate to tia portal there wont be any problem in logic or hardware? pls suggest