Highrise Hydraulics Video

  Рет қаралды 15,738

PoudreFireAuthority

PoudreFireAuthority

7 жыл бұрын

This video is to show how our highrise hydraulics were determined and to use the guage on the standpipe

Пікірлер: 6
@MrLhill1222
@MrLhill1222 3 жыл бұрын
I am a fire sprinkler contractor that test these systems, this is great insight on why we test these systems.
@willlock3644
@willlock3644 Жыл бұрын
Great video!! I wanted to add something about the FDC pressures. High rise buildings are required to have signage showing the pressure required to hit 100 psi at the top.
@thiagoduarte7916
@thiagoduarte7916 5 жыл бұрын
Congratulation for your explanation! How many psi are necessary to firefight a flashover Room in a comercial building ?
@chriswilson965
@chriswilson965 5 жыл бұрын
Just found the video. Looking at 2" with 2.5" couplings for our hirise paks. Do yall plan for putting a second line in play on the fire floor? Just didnt see that option in your hookup.
@Rescue-mt7fl
@Rescue-mt7fl 3 жыл бұрын
Chris, consider both 2” and 2.5”. You truly gather a larger fire flow from the 2.5, especially with 1.75 tip or 1 1/4 tip. Always consider the potential failure of the fire pump. In pumping to a high rise with appliance loss, you may very likely not have the flow from the hookup in question for two lines. Gated wyes are pressure robbers and when flowing high GPM or pressures, wyes are very dangerous. All pressures are transferred from one line to the next as lines are opened and closed. Consider instead the larger line is controlling your hallway or in open offices, giving you the reach through the cubicles from defensible positions. Consider the fire loads for your jurisdiction in determining size of high rise lines. You should also always be planning to pump to the highest floor in the building. As fire doors are opened through escape and fire attack, you must consider fire spread to the floors above. Use of the inline gauge and figuring fire flow per floor with use of a person to monitor that is spot on. Many departments use the 3rd or 4th person on the line who is responsible for monitoring fire flow and feeding lines.
@billsmith5109
@billsmith5109 Жыл бұрын
@@Rescue-mt7fl Some of the British fire brigades have changed to 30mm solid tips, using 65mm hose. A little math shows this is almost exactly a 1-3/16” tip, with 65mm close to 2-1/2” hose. Yes, Akron makes a 1-3/16” tip. At your NP = 45psi the 1-3/16 tip flows 280 gpm. I think they sized up to 30mm especially for open office floor plans. Remember sprinklers are much less common in the U.K., and they want to be ready in event system doesn’t operate. I don’t think their FP bureaus have historically been right on top of periodic ITM enforcement. Is yours? One indicator of that question is, do you have an inventory by building of all active FPS in your jurisdiction? If you don’t, you probably don’t have an effective ITM enforcement system unless you’re tiny.
Standpipe Operations, Part 1: System Orientation
1:29:11
Fire Engineering
Рет қаралды 3,3 М.
Highrise Hose Deployment Video
6:56
PoudreFireAuthority
Рет қаралды 70 М.
Smart Sigma Kid #funny #sigma #comedy
00:40
CRAZY GREAPA
Рет қаралды 32 МЛН
Best Toilet Gadgets and #Hacks you must try!!💩💩
00:49
Poly Holy Yow
Рет қаралды 22 МЛН
Sigma Kid Hair #funny #sigma #comedy
00:33
CRAZY GREAPA
Рет қаралды 39 МЛН
High Rise - Fire Floor Ops
18:53
Fort Worth Fire Department Training
Рет қаралды 16 М.
1-3/4” versus 2-1/2” for Standpipe Operations  (Ep #59)
2:54
Elkhart Brass
Рет қаралды 16 М.
Standpipe Flow Test
3:13
George Malarchik
Рет қаралды 5 М.
Setting the Pressure at the Standpipe
5:53
Tim Vandermeer
Рет қаралды 35 М.
The proper way to fold a high rise load
3:15
SMFR911
Рет қаралды 16 М.
Standalone HydraCALC Standpipe Calculation
24:32
GA Blackburn
Рет қаралды 2,7 М.
High Rise Operations - Driver/Operator Duties
4:09
Glenside Fire Company
Рет қаралды 4,9 М.
Standpipe Valve Outlets (Episode #47)
3:42
Elkhart Brass
Рет қаралды 12 М.
Calculating Pump Discharge Pressure
5:37
Dallas Fire-Rescue Training
Рет қаралды 20 М.
Smart Sigma Kid #funny #sigma #comedy
00:40
CRAZY GREAPA
Рет қаралды 32 МЛН