The way y’all teaching the apprentice is how it’s supposed to be done. Patient and with respect … no making fun or belittling a guy. The trade needs more of this
@linemanundergroundworld48549 ай бұрын
Wazzup swag thank you I try always to teach and show them how things should be done. And have a happy new year 🎊
@MattMorris4817 ай бұрын
I think there could be a good middle ground I mean there’s no need to belittle people, but being razzed is just part of coming up no reason to be nasty while teaching.
@desertviking8 ай бұрын
That’s some good work gentlemen. I’d cover up those arms but that’s me, beautifully done.
@linemanundergroundworld48548 ай бұрын
Wazzup desertviking ya we do our best always watch where and how far our arms and elbows are when working high-voltage.. hope all is well in AZ and thanks for looking out for us…👍😎
@chasefrank81438 ай бұрын
A nice calm crew. Thats is how it should be 🤘🤘
@linemanundergroundworld48548 ай бұрын
Wazzup Chase thanks but we have our moments out there, but we do our best to stay clam as much as possible..🤣🤣👍
@chasefrank81438 ай бұрын
@linemanundergroundworld4854 lol oh I understand that's everywhere, but yall are showing how a crew should work together. Yall be safe out there 🤟🤟🤟💪💪
@justincantrell49807 ай бұрын
Love to see my union brothers getting after it and instructing young apes on how its done. Yall men be safe! Local 317
@linehandibew620511 ай бұрын
They had plenty of 4kv bayonet fuses in Puerto Rico, great video hope there is a part 2. Stay safe brothers!!!
@linemanundergroundworld485411 ай бұрын
Wazzup linehand hope all is well in Puerto Rico. And if we go back to that job there will be a part 2 .
@linehandibew620511 ай бұрын
@@linemanundergroundworld4854 I work on Long Island. I was on Puerto Rico back in 2017 for a hurricane.
@JimwombatLand3 ай бұрын
38 yrs line work , bucket , Regulators, capacitors, downtown ug , trouble shooting , loved bucket work...
@ramelwilliams883011 ай бұрын
That fact that you guys do everything as far as pull cable ug and over head , the connections on both too i give it to u. My company we got different departments for everything
@linemanundergroundworld485411 ай бұрын
Wazzup ramel we kinda do the same ..
@liam32842 ай бұрын
If the transformers don't match exactly, would parallel operation cause large circulating currents?
@scvmface725311 ай бұрын
I work for Rhode Island energy I’m in a 18 month lock in my office department but as soon as it’s up I’m going to overhead lines or underground whatever is open can’t wait
@freethinkingamerican804 ай бұрын
Love watching your videos, work with a few of yalls ex-employees over where I work.
@christyler50937 ай бұрын
Hey man I love the work curious about him being on hooks next to primary. Was there an open point and grounds not bashing just curious on the policy
@linemanundergroundworld48547 ай бұрын
Wazzup Christyler that’s right what you see and we do most of the time work energized 4.8kv at any given time, we hardly ever work with opens unless we really have to for any special reason, that’s how we do our work here , and use rubber goods to protect us while in the primary.. thanks , what company do you work for and what location are you at…?? Thanks
@darnoth772Ай бұрын
no sleeves?
@tylerck283311 ай бұрын
Split bolt connections to feed your buss, hard to believe that"s still a thing some places do!
@linemanundergroundworld485411 ай бұрын
Wazzup Tyler what’s the latest in new or different ways in your utility.. let me know or post a pic. Stay safe and healthy over there..👍😎
@tylerck283311 ай бұрын
@@linemanundergroundworld4854 where I am in Ontario, Canada , we use ampact connections. But I always love to see different ways to get the job done !
@linemanundergroundworld485411 ай бұрын
@@tylerck2833 wazzup Tyler this is temp, and we also use ampac”s for perm connections stay safe over there
@Jon_Drew9 ай бұрын
Im at Coned in NYC. I work in the services department. We do everything that involves the secondary; pulling, rigging, troubleshooting, meters, in both 10% overhead and 90% underground applications. My goal is to get into the overhead, even if it's for another company in another state.
@linemanundergroundworld48549 ай бұрын
Hey Jon message me back on my instagram I have a few questions for you.. thanks
@jxblove12356 ай бұрын
What yard? They just had a posting for overhead.
@Jon_Drew6 ай бұрын
@linemanundergroundworld4854 hey brother,sorry for the delay. I don't have Instagram. Most I have is Facebook
@Jon_Drew6 ай бұрын
@jxblove1235 in Van Nest. I posted for it, waiting to see what happens. Supposedly, there only taking 6 guys for the overhead for the bronx/westchester.
@jxblove12355 ай бұрын
My bad, didn’t see this response. Check PSEG for apprenticeship. It’s open right now, that’s where everyone is headed anyway! I just bounced, not too long ago once I got my HV title.
@johnovat2 ай бұрын
May i know the voltage?
@HYPHYRAGE3036 ай бұрын
how do you know the power won't turn on and shock you? like I'm guessing they turn it off in some way or another but how are you sure you wont cause an arc or anything?
@MattMorris4817 ай бұрын
Man they used to make us wear are sleeves setting poles, even inside an underground transformer hell they made us wear gloves and sleeves setting a meter.
@salvagetone821311 ай бұрын
Those old style disconnects!!
@fightermizan2924 ай бұрын
Very nice system❤❤❤
@JimwombatLand3 ай бұрын
screw drivers in top of pole ....brings back soo many memories ...
@linemanundergroundworld48543 ай бұрын
Wazzup Jim still doing it, when did you retire seems like it. 👍😎
@reesekramer56698 ай бұрын
Upside down location in modern day. Wild!
@linemanundergroundworld48548 ай бұрын
Wazzup reesek that’s right, hope all is well..
@reesekramer56698 ай бұрын
@@linemanundergroundworld4854 what part of the country runs 4.8 🔺? I work outta Detroit and my be seen it in NY, I’m just curious where ur at??
@linemanundergroundworld48548 ай бұрын
@@reesekramer5669 wazzup reesek I am in sunny California and in the city of Losangeles , and all our primary voltage is delta 4.8kv and stay safe over there ..
@reesekramer56695 ай бұрын
Yall tape the low side of the cut outs to the arm?
@RJBeee914 ай бұрын
@@linemanundergroundworld4854 I've obviously got so much to learn as an apprentice lineman, but I'm on the other side of the country working for a Coop and there's talk of upgradingour primary voltage from 7200 to 19.9 wye due to load demands. I'm actually so confused how LA runs on 4.8kv with that tiny wire- looked like 6 solid copper? Smallest we even go on our system is 6 solid and those are on our oldest circuits that are slated to be rephased #4 ACSR. Maybe you guys just have tons of substations to distribute your load? Can't wrap my head around it lol. All I can say is obviously it works for LA, so obviously I just don't know enough about how all this shit works.
@REWYRED5 ай бұрын
Where I live before the utility was bought out they had several trailer mounted transformers for temporary use such as this or if a back yard can failed they would set one up at the start of the line and feed into the secondary. Cant have that now, tweakers would be trying to steal it and the copper conductor. Now everything gets de energized until repairs are made, if you are out 8..12...16 hours, too bad...
@liam32842 ай бұрын
Copper theives ruin everything.
@diedfrombored52957 ай бұрын
This is badass I applied for apprenticeship where i'm at locally can't wait to do this stuff. By the way what level is the apprentice? Just want to know how long it takes to get to be able to do this stuff as apprentice.
@linemanundergroundworld48547 ай бұрын
Wazzup dead from here at dwp you have to be at 3rd step in order to work on the primary 4.8kv , where are you at and with what company’s have you applied for the apprenticeship..
@DigitalIP5 ай бұрын
Would be nice if my power company would come and remove their old pole that they left behind in my yard due to a similar issue. Getting ahold of Engineering shouldnt take months.
@corevetteАй бұрын
lose that @ in the middle of the video!!
@lewy13 ай бұрын
Why have the transformer below secondary on new construction
@nomansland782 ай бұрын
Are the rubber arm sleeves a rule state by state? I see the rubber gloves but in Texas they wear both regardless.
@linemanundergroundworld48542 ай бұрын
@@nomansland78 wazzup that question I really can’t answer, because utilities or contractors do different things with that question
@ericthehalfmexican918711 ай бұрын
Are those live?
@Joe-oo3xv8 ай бұрын
No sleeves ?
@linemanundergroundworld48548 ай бұрын
Wazzup Joe and that’s correct no sleeves But it’s probably coming soon but as of now not yet , what company do you work at that you guys are wearing them ..??
@lewy13 ай бұрын
Sleeves are not required with proper training
@Joe-oo3xv3 ай бұрын
@@lewy1 I disagree but ok. Every extra protection you can take is life saving.
@lewy13 ай бұрын
@@Joe-oo3xv Proper cover up and only working on one phase. You should never be reaching past a phase to work on another. In over 30 years never saw a pair of sleeves until storm chasing into the states. Never had an issue or saw an issue.
@Joe-oo3xv3 ай бұрын
@@lewy1 Most companies here require them when working primary voltages. Including setting poles inbetween primary circuits