Hit pole and going to put up a temp transformer to parallel them and remove the one on the hit pole.

  Рет қаралды 16,078

Linemanundergroundworld

Linemanundergroundworld

Күн бұрын

Пікірлер: 61
@swagbucks4345
@swagbucks4345 9 ай бұрын
The way y’all teaching the apprentice is how it’s supposed to be done. Patient and with respect … no making fun or belittling a guy. The trade needs more of this
@linemanundergroundworld4854
@linemanundergroundworld4854 9 ай бұрын
Wazzup swag thank you I try always to teach and show them how things should be done. And have a happy new year 🎊
@MattMorris481
@MattMorris481 7 ай бұрын
I think there could be a good middle ground I mean there’s no need to belittle people, but being razzed is just part of coming up no reason to be nasty while teaching.
@desertviking
@desertviking 8 ай бұрын
That’s some good work gentlemen. I’d cover up those arms but that’s me, beautifully done.
@linemanundergroundworld4854
@linemanundergroundworld4854 8 ай бұрын
Wazzup desertviking ya we do our best always watch where and how far our arms and elbows are when working high-voltage.. hope all is well in AZ and thanks for looking out for us…👍😎
@chasefrank8143
@chasefrank8143 8 ай бұрын
A nice calm crew. Thats is how it should be 🤘🤘
@linemanundergroundworld4854
@linemanundergroundworld4854 8 ай бұрын
Wazzup Chase thanks but we have our moments out there, but we do our best to stay clam as much as possible..🤣🤣👍
@chasefrank8143
@chasefrank8143 8 ай бұрын
@linemanundergroundworld4854 lol oh I understand that's everywhere, but yall are showing how a crew should work together. Yall be safe out there 🤟🤟🤟💪💪
@justincantrell4980
@justincantrell4980 7 ай бұрын
Love to see my union brothers getting after it and instructing young apes on how its done. Yall men be safe! Local 317
@linehandibew6205
@linehandibew6205 11 ай бұрын
They had plenty of 4kv bayonet fuses in Puerto Rico, great video hope there is a part 2. Stay safe brothers!!!
@linemanundergroundworld4854
@linemanundergroundworld4854 11 ай бұрын
Wazzup linehand hope all is well in Puerto Rico. And if we go back to that job there will be a part 2 .
@linehandibew6205
@linehandibew6205 11 ай бұрын
@@linemanundergroundworld4854 I work on Long Island. I was on Puerto Rico back in 2017 for a hurricane.
@JimwombatLand
@JimwombatLand 3 ай бұрын
38 yrs line work , bucket , Regulators, capacitors, downtown ug , trouble shooting , loved bucket work...
@ramelwilliams8830
@ramelwilliams8830 11 ай бұрын
That fact that you guys do everything as far as pull cable ug and over head , the connections on both too i give it to u. My company we got different departments for everything
@linemanundergroundworld4854
@linemanundergroundworld4854 11 ай бұрын
Wazzup ramel we kinda do the same ..
@liam3284
@liam3284 2 ай бұрын
If the transformers don't match exactly, would parallel operation cause large circulating currents?
@scvmface7253
@scvmface7253 11 ай бұрын
I work for Rhode Island energy I’m in a 18 month lock in my office department but as soon as it’s up I’m going to overhead lines or underground whatever is open can’t wait
@freethinkingamerican80
@freethinkingamerican80 4 ай бұрын
Love watching your videos, work with a few of yalls ex-employees over where I work.
@christyler5093
@christyler5093 7 ай бұрын
Hey man I love the work curious about him being on hooks next to primary. Was there an open point and grounds not bashing just curious on the policy
@linemanundergroundworld4854
@linemanundergroundworld4854 7 ай бұрын
Wazzup Christyler that’s right what you see and we do most of the time work energized 4.8kv at any given time, we hardly ever work with opens unless we really have to for any special reason, that’s how we do our work here , and use rubber goods to protect us while in the primary.. thanks , what company do you work for and what location are you at…?? Thanks
@darnoth772
@darnoth772 Ай бұрын
no sleeves?
@tylerck2833
@tylerck2833 11 ай бұрын
Split bolt connections to feed your buss, hard to believe that"s still a thing some places do!
@linemanundergroundworld4854
@linemanundergroundworld4854 11 ай бұрын
Wazzup Tyler what’s the latest in new or different ways in your utility.. let me know or post a pic. Stay safe and healthy over there..👍😎
@tylerck2833
@tylerck2833 11 ай бұрын
@@linemanundergroundworld4854 where I am in Ontario, Canada , we use ampact connections. But I always love to see different ways to get the job done !
@linemanundergroundworld4854
@linemanundergroundworld4854 11 ай бұрын
@@tylerck2833 wazzup Tyler this is temp, and we also use ampac”s for perm connections stay safe over there
@Jon_Drew
@Jon_Drew 9 ай бұрын
Im at Coned in NYC. I work in the services department. We do everything that involves the secondary; pulling, rigging, troubleshooting, meters, in both 10% overhead and 90% underground applications. My goal is to get into the overhead, even if it's for another company in another state.
@linemanundergroundworld4854
@linemanundergroundworld4854 9 ай бұрын
Hey Jon message me back on my instagram I have a few questions for you.. thanks
@jxblove1235
@jxblove1235 6 ай бұрын
What yard? They just had a posting for overhead.
@Jon_Drew
@Jon_Drew 6 ай бұрын
@linemanundergroundworld4854 hey brother,sorry for the delay. I don't have Instagram. Most I have is Facebook
@Jon_Drew
@Jon_Drew 6 ай бұрын
@jxblove1235 in Van Nest. I posted for it, waiting to see what happens. Supposedly, there only taking 6 guys for the overhead for the bronx/westchester.
@jxblove1235
@jxblove1235 5 ай бұрын
My bad, didn’t see this response. Check PSEG for apprenticeship. It’s open right now, that’s where everyone is headed anyway! I just bounced, not too long ago once I got my HV title.
@johnovat
@johnovat 2 ай бұрын
May i know the voltage?
@HYPHYRAGE303
@HYPHYRAGE303 6 ай бұрын
how do you know the power won't turn on and shock you? like I'm guessing they turn it off in some way or another but how are you sure you wont cause an arc or anything?
@MattMorris481
@MattMorris481 7 ай бұрын
Man they used to make us wear are sleeves setting poles, even inside an underground transformer hell they made us wear gloves and sleeves setting a meter.
@salvagetone8213
@salvagetone8213 11 ай бұрын
Those old style disconnects!!
@fightermizan292
@fightermizan292 4 ай бұрын
Very nice system❤❤❤
@JimwombatLand
@JimwombatLand 3 ай бұрын
screw drivers in top of pole ....brings back soo many memories ...
@linemanundergroundworld4854
@linemanundergroundworld4854 3 ай бұрын
Wazzup Jim still doing it, when did you retire seems like it. 👍😎
@reesekramer5669
@reesekramer5669 8 ай бұрын
Upside down location in modern day. Wild!
@linemanundergroundworld4854
@linemanundergroundworld4854 8 ай бұрын
Wazzup reesek that’s right, hope all is well..
@reesekramer5669
@reesekramer5669 8 ай бұрын
@@linemanundergroundworld4854 what part of the country runs 4.8 🔺? I work outta Detroit and my be seen it in NY, I’m just curious where ur at??
@linemanundergroundworld4854
@linemanundergroundworld4854 8 ай бұрын
@@reesekramer5669 wazzup reesek I am in sunny California and in the city of Losangeles , and all our primary voltage is delta 4.8kv and stay safe over there ..
@reesekramer5669
@reesekramer5669 5 ай бұрын
Yall tape the low side of the cut outs to the arm?
@RJBeee91
@RJBeee91 4 ай бұрын
@@linemanundergroundworld4854 I've obviously got so much to learn as an apprentice lineman, but I'm on the other side of the country working for a Coop and there's talk of upgradingour primary voltage from 7200 to 19.9 wye due to load demands. I'm actually so confused how LA runs on 4.8kv with that tiny wire- looked like 6 solid copper? Smallest we even go on our system is 6 solid and those are on our oldest circuits that are slated to be rephased #4 ACSR. Maybe you guys just have tons of substations to distribute your load? Can't wrap my head around it lol. All I can say is obviously it works for LA, so obviously I just don't know enough about how all this shit works.
@REWYRED
@REWYRED 5 ай бұрын
Where I live before the utility was bought out they had several trailer mounted transformers for temporary use such as this or if a back yard can failed they would set one up at the start of the line and feed into the secondary. Cant have that now, tweakers would be trying to steal it and the copper conductor. Now everything gets de energized until repairs are made, if you are out 8..12...16 hours, too bad...
@liam3284
@liam3284 2 ай бұрын
Copper theives ruin everything.
@diedfrombored5295
@diedfrombored5295 7 ай бұрын
This is badass I applied for apprenticeship where i'm at locally can't wait to do this stuff. By the way what level is the apprentice? Just want to know how long it takes to get to be able to do this stuff as apprentice.
@linemanundergroundworld4854
@linemanundergroundworld4854 7 ай бұрын
Wazzup dead from here at dwp you have to be at 3rd step in order to work on the primary 4.8kv , where are you at and with what company’s have you applied for the apprenticeship..
@DigitalIP
@DigitalIP 5 ай бұрын
Would be nice if my power company would come and remove their old pole that they left behind in my yard due to a similar issue. Getting ahold of Engineering shouldnt take months.
@corevette
@corevette Ай бұрын
lose that @ in the middle of the video!!
@lewy1
@lewy1 3 ай бұрын
Why have the transformer below secondary on new construction
@nomansland78
@nomansland78 2 ай бұрын
Are the rubber arm sleeves a rule state by state? I see the rubber gloves but in Texas they wear both regardless.
@linemanundergroundworld4854
@linemanundergroundworld4854 2 ай бұрын
@@nomansland78 wazzup that question I really can’t answer, because utilities or contractors do different things with that question
@ericthehalfmexican9187
@ericthehalfmexican9187 11 ай бұрын
Are those live?
@Joe-oo3xv
@Joe-oo3xv 8 ай бұрын
No sleeves ?
@linemanundergroundworld4854
@linemanundergroundworld4854 8 ай бұрын
Wazzup Joe and that’s correct no sleeves But it’s probably coming soon but as of now not yet , what company do you work at that you guys are wearing them ..??
@lewy1
@lewy1 3 ай бұрын
Sleeves are not required with proper training
@Joe-oo3xv
@Joe-oo3xv 3 ай бұрын
@@lewy1 I disagree but ok. Every extra protection you can take is life saving.
@lewy1
@lewy1 3 ай бұрын
@@Joe-oo3xv Proper cover up and only working on one phase. You should never be reaching past a phase to work on another. In over 30 years never saw a pair of sleeves until storm chasing into the states. Never had an issue or saw an issue.
@Joe-oo3xv
@Joe-oo3xv 3 ай бұрын
@@lewy1 Most companies here require them when working primary voltages. Including setting poles inbetween primary circuits
New Project to remove Flooded land working by Dozer M3 & 5T Truck
1:29:59
Mega Heavy Machine
Рет қаралды 1,8 М.
POV: Your kids ask to play the claw machine
00:20
Hungry FAM
Рет қаралды 22 МЛН
Bike Vs Tricycle Fast Challenge
00:43
Russo
Рет қаралды 97 МЛН
Hazardous tension on Powerline - working solo
21:21
Bobsdecline - Lineman blogger
Рет қаралды 69 М.
No power!... all cutouts are closed !?
23:21
Bobsdecline - Lineman blogger
Рет қаралды 127 М.
Easy said than done replacing underground service..
27:57
Linemanundergroundworld
Рет қаралды 3,2 М.
Lineman Training: Climbing Techniques for a Beginning Student
13:58
Blue Ridge Community and Technical College
Рет қаралды 646 М.
Not Just Another Day-Gerry Kinney's Story by Safe Electricity.org
21:43
Mountain View Electric Association
Рет қаралды 89 М.
Distribution Transformers 1
9:18
Susan Blaser
Рет қаралды 124 М.
Changing blown transformer!
30:58
Bobsdecline - Lineman blogger
Рет қаралды 373 М.
A breaker disguised as a meter
19:16
Bobsdecline - Lineman blogger
Рет қаралды 1,1 МЛН
Pt-2 finishing up on the transferring and did a ( pull - push ) on the transformers
10:11
Lineman - Pole climbing
16:59
Bobsdecline - Lineman blogger
Рет қаралды 202 М.