@lynncomstock1255
@lynncomstock1255 4 ай бұрын
This digital scroll works because the check valve (not shown or mentioned) keeps the high pressure discharge gas from backing up when the compressor is unloaded.
@stevenygabbyperez695
@stevenygabbyperez695 4 жыл бұрын
Acoustic means loud as hell especially on a bigger one.
@Sigmameals
@Sigmameals 3 жыл бұрын
Hi Tony, Can you put what you explained about HGBV on a PH diagram or in equation forms in terms of thermodynamic cycle?
@willytangkere5784
@willytangkere5784 12 күн бұрын
Gibson heat pump,are still made in Indianapolis US ,BDP PRODUCT ?
@nakiapringley5391
@nakiapringley5391 8 ай бұрын
Great video
@imrocSupermarketRefrig
@imrocSupermarketRefrig 4 жыл бұрын
I appreciate your videos, Tony. What and how are the these controlled? Is there a digital controller that's taking sample readings of suction pressure and/or temperature? Room temp? Etc. I see a lot of cut-away videos of "how" these compressors operate, but nothing really clear on what's controlling these. Thanks
@Human-bf7kz
@Human-bf7kz 3 жыл бұрын
I think they work using feedback pressure based on this video. It seems more mechanical and less digital . kzbin.info/www/bejne/mpCphGBprseajqc let me know if you get any answers . As for Tony , I couldn't connect to his website . You can try to connect with him via LinkedIn .
@shuaib8908
@shuaib8908 2 жыл бұрын
He does a hot gas bypass give wear and tear when the discharge is entered from the evap inlet?? You would still get a cold suction line and good superheat if it’s setup properly
@subarkahasep
@subarkahasep 3 жыл бұрын
Hi Tony , could you please share how to do selection of the hot gas bypass valve itself? For example this is for cooling tunnel apolication, on this application we need to keep temperature stable and in other side we need to avoid the evaporator freezing ..thanks in advance
@Sigmameals
@Sigmameals 3 жыл бұрын
You can search online for literature on HGBV.
@willytangkere5784
@willytangkere5784 12 күн бұрын
I re like heat pump with hot gas by pass idea
@prithwishdey6708
@prithwishdey6708 4 жыл бұрын
Please discuss ICM-220 lock out relay Waring cannection
Digital Scroll Compressor vs Variable Speed Compressor
8:08
Know Hot Gas Bypass? Advanced Refrigeration 2022 Part 1
39:45
Чистка воды совком от денег
00:32
FD Vasya
Рет қаралды 5 МЛН
Правильный подход к детям
00:18
Beatrise
Рет қаралды 9 МЛН
Support each other🤝
00:31
ISSEI / いっせい
Рет қаралды 37 МЛН
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 102 МЛН
Hot Gas Bypass Valve Application and Low Load Conditions
6:18
HVAC Know It All
Рет қаралды 61 М.
Hot Gas Reheat vs. Hot Gas Bypass
6:14
HVAC TV
Рет қаралды 8 М.
Copeland Scroll Compressor Teardown
7:03
John Brown
Рет қаралды 66 М.
Hot Gas Reheat Function and Purpose
6:57
HVAC TV
Рет қаралды 8 М.
Diagnosing Poor Compression
13:53
HVAC School
Рет қаралды 81 М.
AC Pressures, Subcooling and Superheat
29:52
HVAC School
Рет қаралды 267 М.
COPELAND DIGITAL SCROLL CONTROLLER /MODULE / COMPRESSOR
21:11
D2D NY Real World HVAC Simplified
Рет қаралды 11 М.
Making a Refrigerant - A Behind the Scenes Look with Dr. Charles Allgood of Chemours
44:10
ESCO Institute-HVAC Excellence
Рет қаралды 1,5 М.
Inside The Digital Scroll Compressor
4:11
HVAC TV
Рет қаралды 4 М.
Чистка воды совком от денег
00:32
FD Vasya
Рет қаралды 5 МЛН