How an X-Ray Tube Works⚡How X-Rays are Generated

  Рет қаралды 10,320

VirtualBrain [ENG]

VirtualBrain [ENG]

7 ай бұрын

Participate in the 6th PCBWay Design Contest and win up to 1500USD! Upload your project until January 15, 2024 at
www.pcbway.com/activity/6th-p...
In this chapter we will see how X-ray tubes work and the different mechanisms used to achieve their purpose.
My Social Networks:
◉ Instagram: / virtual_brain
What software do I use?
◉ 3D Animations: Blender (www.blender.org/)
◉ Editing and 2D effects: Davinci Resolve

Пікірлер: 13
@Dark_Matter2
@Dark_Matter2 7 ай бұрын
Very interesting video, thank you.
@lucianalvark321
@lucianalvark321 7 ай бұрын
Masterpiece
@Coowallsky
@Coowallsky 27 күн бұрын
Molybdenum is more often used than tungsten for the anode. Modern day X-Ray tubes for medical use have voltagte requirements from 25 to 150+ kilovolts. Available current in range from 100 to 1000 milliamps.
@bhanuteja_1222
@bhanuteja_1222 7 ай бұрын
Super
@nwetkyi1424
@nwetkyi1424 Ай бұрын
very interesting
@KarldorisLambley
@KarldorisLambley 7 ай бұрын
very useful indeed. i just bought an old xray tube from ebay. ive tested continuity, it seems fine. loads of volts is easy, but i wondered about it's current requirements. thanks
@Coowallsky
@Coowallsky 27 күн бұрын
Typical current for modern x-ray tubes is 100 - 1000 milliamperes depending on object mass of the desired part to be x-rayed.
@KarldorisLambley
@KarldorisLambley 25 күн бұрын
@@Coowallsky so you suggest i give a few v to the heater, then give the valve around 50kv, with a 100mA limited supply to start? i have been waiting to use this valve for 6 months, it is ancient, so no datasheet. but i dont want to kill it.
@Coowallsky
@Coowallsky 25 күн бұрын
@@KarldorisLambley Filament voltage of about 10 VDC cuerrent typically 3 to 5 amps. X-Ray equipment up to 1980 used Full-Wave rectifed High Voltage for what amounted to a pulsating DC voltage (it wasn't filtered after rectification. Some portable x-ray units used capacitive discharge which eliminated the ripple but were limited on exposure time and current (typical for portable). If I were going to do it, I would shroud the tube with 4# lead sheeting.
@abdulla9042
@abdulla9042 5 ай бұрын
Hello, I can translate your video?
@robertkattner1997
@robertkattner1997 7 ай бұрын
Boring, learn that 45 years ago.
@Spigglinggognug
@Spigglinggognug 4 ай бұрын
Then why are you watching mister knowitall
@Coowallsky
@Coowallsky 27 күн бұрын
@@Spigglinggognug I learned that 45 years ago and it still fascinatess me.
History of X-rays
24:21
Doctor Klioze
Рет қаралды 268 М.
X-Ray Tube Anatomy: X-Ray Production Explained!
10:58
Sahand Hooshmand
Рет қаралды 3,8 М.
1❤️#thankyou #shorts
00:21
あみか部
Рет қаралды 70 МЛН
I Need Your Help..
00:33
Stokes Twins
Рет қаралды 178 МЛН
#donglemadness. ONIX Alpha XI1 Review & Comparison
25:59
AndyAudioVault
Рет қаралды 3,9 М.
A Permanent Magnet That Turns On and Off
9:55
The Action Lab
Рет қаралды 2,2 МЛН
How do Electron Microscopes Work? 🔬🛠🔬 Taking Pictures of Atoms
19:54
Branch Education
Рет қаралды 2,8 МЛН
5D Quartz ETERNAL Storage 💿 How it Works
15:24
VirtualBrain [ENG]
Рет қаралды 28 М.
Why The First Computers Were Made Out Of Light Bulbs
18:56
Veritasium
Рет қаралды 5 МЛН
I bought 1000 meters of wire to settle a physics debate
22:49
AlphaPhoenix
Рет қаралды 3 МЛН
What If Swings Had Springs Instead Of Ropes: Autoparametric Resonance
15:25
The Insane Engineering of MRI Machines
17:53
Real Engineering
Рет қаралды 2,9 МЛН
I Made a Neural Network with just Redstone!
17:23
mattbatwings
Рет қаралды 531 М.
The ingenious micro-mechanisms inside your phone
19:31
Breaking Taps
Рет қаралды 1,1 МЛН