At last! This makes so much sense. TRVs just don’t cut the mustard, and having a room stat and actuator on each room is just perfick! Hats off to multi pipe for spotting the hole in the market…..
@MultipipeLtd3 жыл бұрын
thanks Neil for your lovely message!
@MultipipeLtd3 жыл бұрын
👉Did you find the information in this video helpful? Let us know by leaving a comment below!
@dorsetengineering3 жыл бұрын
A good introduction to the principals behind manifold plumbing, lots of British plumbers wouldn't think to plum rads like this yet it make so much more sense. The benefit of a zone per room can't be overloooked. And no cost for t's or elbows, just an MLC-Copper transition at the rad.
@handresi Жыл бұрын
Do you need an additional loop not supplying a rad to act as a bypass? Im thinking about thermostat calling for heat, but rads being closed via TRV (if still fitted), or perhaps the only room calling for heat being a smal bathroom towel rail for example.
@MultipipeLtd Жыл бұрын
the hydraulics is the same if it is a standard branch system (a manifold just centralises the branches) we do recommend a auto bypass is fitted, to stop pump issues. but as more zones shut you may get boiler lockouts, without going down buffers it is hard to avoid this, good rad balancing can really help though.
@paulhill9132 Жыл бұрын
I agree about the TRV's being located next to the radiator not being ideal, but it would require much more pipe to feed each radiator individually from the manifold. Not only is that likely to mean lots more holes through joists, more piping running around the house that could be damaged, but also heat loss from all that piping! Maybe I'm a luddite, but not sure manifolds for radiators is the best way to go, especially when you can now purchase remote controlled TRV's with wall mounted thermostats!
@MultipipeLtd Жыл бұрын
You have some very good points you make. However, having single pipe runs with no fittings underfloor massively reduces the chance of leaks. Agreed, more pipework is installed, but in terms of heatloss, most of the time, you run pipework in the floor void of the first floor. This means any heat radiated is actually a contributor to the room's heating, so it is not technically lost. anything in attics, etc., we highly recommend lagging pipework. the snag with wireless TRV's is batteries require replacement every year. but thanks for your comments!
@MrAlang19843 жыл бұрын
If using a manifold for rads only does it require a separate pump and mixing valve like a UFH system or is it a direct connection to the feed and return to the boiler?
@MultipipeLtd3 жыл бұрын
Hi Alan, thanks for the question. No, you will not need any mixing or pump control as you would always run the Rads at the boiler's temperature. Also, the idea of the manifold system would actually reduce the overall duty, so the boiler pump would be fine. Just try and limit run out to 25m max.
@deeeirl2 жыл бұрын
Looking into replacing current pipework (copper) in a 90s build bungalow with concrete floors. Is there a limit on the maximum length from the manifold to a radiator that's recommended? or would splitting the system with 2 manifolds be a better option? Also, Is this available in Ireland via reseller? Thanks
@MultipipeLtd2 жыл бұрын
Derek, thanks for your comment. we normally don't recommend exceeding 15m from manifold to radiator, but this does vary a bit depending on the radiator's output. We cannot arrange an export now. But call us on 01245 227630, and you can arrange your own courier to collect from us.
@1000Mikey2 жыл бұрын
Hi there. I've just bought a new house that needs completely renovating. This sounds like a winner and would go nicely with the planned ufh on the ground floor. Can you balance the radiators via the manifold? can you adapt to different pipe directly from the manifold? Are the actuator sizes a generic size? thanks
@MultipipeLtd2 жыл бұрын
Thanks for watching our video, you are correct they work very nice with UFH on the ground floor as the controls can be done in a similar fashion with induvial control for each room giving far greater flexibility. Also, like UFH, the balancing is done at the manifold. If you are not using our UFH/controls we recommend to use our actuators, these have been tested for our valve pitch, but we can do both 230v and 24v so most controls will work with these. I hope this helps. If you wish for a quote just call us.
@1000Mikey2 жыл бұрын
@@MultipipeLtd sounds spot on. I will definitely be going with this system. Can you adapt to copper, speedfit at the manifold ?
@MultipipeLtd2 жыл бұрын
@@1000Mikey Our manifold is a standard 1" BSP, so copper is fine. As for the outlet, we recommend our MLC pipe. It is well priced and much better for thermal expansion.
@Nafianna322 жыл бұрын
Good video, what's the best way to control a radiator in a bathroom in this setup, if going each room as a zone?
@MultipipeLtd2 жыл бұрын
John, thanks for your question! Because all mains voltage controls are dealt with outside the bathroom (where the manifold is located). A simple wireless thermostat will control when the actuator opens and shuts that radiator loop. If you have any other questions, feel free to comment or call us for a quote.
@alexhaworth3 жыл бұрын
Useful video thanks - when working with radiators - all of my feeds would be going upwards - are there any manifolds with the fittings upside down or do you have to make a few joins in the pipework to change its direction? (that seems wasteful)
@MultipipeLtd3 жыл бұрын
There is no reason you cannot fit this manifold upside down. the air vent can be swapped in orientation/ you would vent from the rad.
@alexhaworth3 жыл бұрын
@@MultipipeLtd Great thank you
@robertakaminskaite7963 Жыл бұрын
Hiya, this sounds like it would be ideal for us. What mm is the feed into the manifold? And also we are planning on installing an air source heat pump - So would the hotfeed into the manifold come directly from the heat pump or from the hot water cylinder?
@MultipipeLtd Жыл бұрын
Being a universal thread we can offer multiple pipework sizes off the manifold but our standard is 16mm. as for connection it has to come direct from the ASHP (normally there would be some zoning on the system)
@illisbillis Жыл бұрын
Is it ok to locate a 6 port manifold below the floor it feeds, I have no location on the first floor to hide the manifold. There will be 6 rads in total.
@MultipipeLtd Жыл бұрын
A radiator manifold is okay to feed from below because you can remove air from the radiator. I hope this helps.
@peteroberts19793 жыл бұрын
Great Video! If you wanted to run multiple manifolds (one for each floor) what would the configuration be? We are looking at 3 floors, Firstly is it possible? and if so would you run a manifold closest to the tank with feeds to the local radiators and feed off this manifold to the second and third manifolds or would you run 22mm from the tank to the furthest manifolds and T off at the other 2 manifold locations? Thanks
@MultipipeLtd3 жыл бұрын
You can do either, by running a large manifold in the plant room with feeds to each manifold, you do get more control for balancing etc. But, most of the time, tee off the feed pipe to each floor is more than good enough.