Sir Mark ... keep those procedures and tips about the features of solis coming ... the manual seems lacking in details ...we are lucky we have you testing every Solis features in great details
@rds00092 ай бұрын
What is the standby power consumption of this Solis?
@DM-gn1gx6 ай бұрын
Hello Mark I am interested in your experience with firm ware on this Inverter, details release notes. My installed unit has version 3E0038 by the way Solis says it won't do what you show here... Thank you for sharing, better then solis.
@ivanvelarde31552 жыл бұрын
This is what i have been waiting this is not shown clearly in the Manual ... now i know why my setting does not work ... i was not turning the inverter off
@ivanvelarde31552 жыл бұрын
Sir Mark , i guess setting up this feature will only work as long as there is at least a PV or Battery supplying power to the inverter . Because on my experience i was not able to set this up at Night no PV ... and a broken battery ... because with both DC supply out the inverter is basically dead . So i would say to be able to set the inverter to do that a requirement is that at least one of thr DC power is present .
@MarkMinoza2 жыл бұрын
Yes, If there is NO battery, it will act as a regular GTi, so you need PV source.
@chriscowap3159 Жыл бұрын
I want to test maintaining the inverters control electronics over night via a DC PSU, into the battery terminals, so the monitoring is kept alive. We have a few systems installed, no battery - 'battery ready' - but we lose overnight grid power logging.. which is annoying.
@MuhammadAli-hh2ml5 ай бұрын
I donot have battery installed with my 6kv solis hybrid inverter, can i run that in load shedding case(without grid) during day time only on PV?
@MarkMinoza5 ай бұрын
@@MuhammadAli-hh2ml S5 doesnt have loading shedding capability.
@leonidovich1025 Жыл бұрын
Hello, Mark. There are clarifications on connecting and disabling the Solis inverter. Ginlong gives the following recommendations: PV, BATTERY, AC, LOAD is a connection. OFF LOAD, off AC, off DC, off BATTERY is a shutdown. Your recommendations are different, where is it right? Regards
@MarkMinoza Жыл бұрын
If your system is energize and running with loads. You need to disconnect your Grid first! You don't disconnect your PV since its under load. You also do not disconnect your backup load since it has a running load. The guide assumes that prior to shutting down the system. You had transfered your backup load to the grid, thus, the proper way of disconnecting is. 1. GRID 2. PV 3. BATTERY.
@edgarrapisora2712 Жыл бұрын
Hi Sir Mark, do you have a video for Solis 6 KW Ongrid/hybrid inverter to be commissioned for the first time without battery.
@MarkMinoza Жыл бұрын
Don't have a unit for that latest hardware.
@barkley9611 ай бұрын
hola, como se configura en el tablero para que el respaldo por batería pueda funcionar ante un corte de energía eléctrica?
@MarkMinoza11 ай бұрын
Please see this how to guide. kzbin.info/www/bejne/hIeseHijbJlgi7csi=RTF2Wnj75IcfjTGS
@barkley9611 ай бұрын
gracias, pero vivo en Chile, me sirve igual?@@MarkMinoza
@leonidovich10252 жыл бұрын
Mark, hello. Thank you for your feedback on the solis inverter. Equipment (switch) is connected to the inverter, which must be in operation for 24 hours. The inverter at off 220V passes to the battery and the time of this transition according to the characteristics is 1 period or 20 ms. After the transition, the connection between the switch and the equipment connected to it disappears. To date, is it possible to reduce the transition time to the backup port to 10 ms? Thank you!
@MarkMinoza2 жыл бұрын
I also asked if they can drop to 10ms, but as per support, the 20ms is standard on all RHI models. If you have issues on sudden shutdown due to switch from grid to off grid, you need to request a firmware update to rectify the problem.
@leonidovich10252 жыл бұрын
Thank you!
@ivanvelarde31552 жыл бұрын
Question what will happen if the PV is cut off under load ? Aside from the obvious arcing
@MarkMinoza2 жыл бұрын
its not advisable unless under certain condition such as an emergency situation. Its not recommended especially when your have a high demand load and you cut off the PV. Hardware malfunction sometimes happens.
@marmata35 Жыл бұрын
If in a Solis grid-tie set up, still do not disconnect P.V. under load, it should be disconnect first the grid then the P.V...
@chriscowap3159 Жыл бұрын
But arent you still driving the inverters control electronics from the battery DC source ? If the battery is still connected physically.... thats not the same as the battery setting being set to none.... Surely....? The battery is still showing as drawing 10w...
@MarkMinoza Жыл бұрын
youre probably correct. it makes sense.
@rogiecoquilla3543 Жыл бұрын
Sir gud pm po, if you are pilipino use tagalog version and translate english version in your screen so that our kababayan and diy er can understand, ty very much