One thing is actually important, and even a lot of professionals do not know, but when drilling through a joist, one needs to drill dead center, if you drill above that, you are removing bearing strength, if you drill below that, you are removing tensile strength from the joist. My father was a construction engineer, and he let me in on that. Boards should have that printed on them. "Drill, dead center only". Almost everywhere I go, they miss that.
@mochissin84m842 жыл бұрын
yeah whatever
@mychaelleesly2 жыл бұрын
@@mochissin84m84 yeah no... it is important to keep the integrity of the joists. Not sure I 100% agree with David's guidance on dead center but this is an important point that electricians and plumbers totally ignore. See Paul Buehler's guidance below for the 1/3 rule.
@jackeroo752 жыл бұрын
Yeah and if they don’t? The whole board going to fail? Nope.
@ROMA--AETERNA2 жыл бұрын
Excellent point. For any simply supported beam, you should only drill through the centre depth of the beam.
@lizardman13032 жыл бұрын
@@ROMA--AETERNA damn my I wished I read this a hr ago my house collapsed
@grimdragon03 Жыл бұрын
Been waiting a year for my electrician to show up for this, SO glad you made this video.
@davidbenevy76922 жыл бұрын
One little code problem here. Assuming this was a 20 amp circuit, as the 12-2 yellow Romex would indicate it is a code violation to extend the line with 14-2. This is true even though the last light would never draw more than 1 amp. The issue is a 15 amp 14-2 wire, should not be protected by a 20 amp breaker. One way this could happen is if someone used a screw in adapter that supported a light and an outlet. Then, conceivably, someone could plug in something drawing over 15 amps and the circuit would be overloaded.
@davidicousgregorian2 жыл бұрын
right but now some companies are now stupidly using white sheathing for 12/2 flat and 12/3 rounded to save money and charge same price also if you noticed there is a yellow 12 g on other side of rafter to the left of screen which might be connected in a box on other side but if it is a 14 white then yes it is wrong and hell catch it hopefully maybe its just for example but whoops we see a problem
@briandillard8125 Жыл бұрын
What if the 12-2 is on a 15 breaker? No problem.
@luvdady Жыл бұрын
@Brian Dillard till someone sees 12 and puts in a 20 amp. I'd just ran more 12 and spent the 84 cents
@briandillard8125 Жыл бұрын
@@luvdady maybe the wire is bigger for voltage drop, or maybe that what they had on hand, either way there is no code that says wire can't be larger than breaker ampacity. Also, my response was that it might not be a code violation just because there are two diffrent wire sizes being used
@jeffreyspence2510 Жыл бұрын
To all of the posters below. Maybe the new wire he added for the second light is an old piece of 12-2 he had sitting around. I have rolls and rolls of white 12-2 that I purchased back when it was cheap.
@RadhadaniteBabylonian3 жыл бұрын
This is JUST the video I was looking for. Simply explained from start to finish as well as talking about wiring codes too. Thanks a ton for your work!!
@weekendhomeprojects2 жыл бұрын
Love these vids!
@morte100 Жыл бұрын
Agreed. The perfect level of detail and safety for a DIYer like myself.
@ronaldkearns60573 жыл бұрын
Thanks for sharing your skills. Just did this in an unfinished portion of my basement, been wanting to do it for 15 years. I watched your video and was able to make it happen.
@EverydayHomeRepairs3 жыл бұрын
Nice! 👍
@csimet3 жыл бұрын
In addition to the explanation of where to drill the holes in a joist... generally speaking, you want the hole in the center third of the joist. Placing holes in the outer thirds (top or bottom) weakens the joist.
@TheHavocdog Жыл бұрын
When I install ceramic light fixtures similar to yours, I always choose a fixture that includes a receptcal. It just gives me one more place to plug in to so it reduces the need for extension cords.
@justgivemethetruth Жыл бұрын
The ones with the strings switches are nice too.
@nigemamobili83 жыл бұрын
The ideal height for that holes is the center of the beam, in this location the bending stresses on beams is cero because is the line where tension and compression force change. Also in the center between the beam supports because the shear stresses are also cero Saludos Gerardo
@petedonna48943 жыл бұрын
Absolutely, but although he didn't say it that way, those looked like 2x8's so his 3" mark was almost center. On a 7¼" board he's ⅝" off center.
@philribaudo4126 Жыл бұрын
apparently you can scratch what I was asking below as I just started watching your video on your mistakes that have been pointed out where you say indeed it is incorrect to connect 14 gauge to 12 gauge-Bravo to you sir! Thanks again for what you are doing!
@berthaduniverse3 жыл бұрын
Yea it's fine to be worried about anchors/nails/screws, but structurally more important to uese the 1/3s rule (in this case avoid drilling in the lower 1/3 of the member) on load bearing members. Almost every hole (pex and electrical) I see drilled here violates the 1/3 rule. If this is going to be exposed above a work space, surface run it in conduit or MC.
@dimsun30397 ай бұрын
Cheers. Much better then going to school to learn this.
@BellaRocko3 жыл бұрын
Thank you so much! This exactly what I am planning to do in my garage, so that I can use the same 3-bulb light fixture that you showed here. So perfect timing, and thanks for sharing!
@EverydayHomeRepairs3 жыл бұрын
Best of luck on the project!
@weekendhomeprojects2 жыл бұрын
Same.
@mynonameyt3 жыл бұрын
When trimming bolts down use electricians wire cutters. Most have at least two sizes to cut off bolts. That way after cutting the bolt down you back it out and that repairs the end.
@EverydayHomeRepairs3 жыл бұрын
Good call Greg 👍
@AgentOffice3 жыл бұрын
How's it repair it
@soisaidtogod42482 жыл бұрын
@@AgentOffice A proper wire stripper tool has threaded areas to put long bolt into, the threads hold the bolt while the cutter allows shortening.
@mighty09742 жыл бұрын
I thread a nut on the screw first. That way, I can take off the nut after the cut and it kind of repairs the end of the screw.
@Furrdaddy33619 күн бұрын
Thank you for the video im going to be putting more lights in my front porch and back porch iv already insulated everything next is drywall after i put new lights up
@steveloux47093 жыл бұрын
One correction for your audience - stapling of the romex must be within 8" of plastic boxes. The 12" reference is valid only if you're using a NM connector. Staple in the field every 4-1/2 feet minimum.
@EverydayHomeRepairs3 жыл бұрын
Thanks for the feedback / correction 👍
@markvanbritsom42093 жыл бұрын
Maximum distance between staples on a beam in wood construction for toned is 3 feet no more, , 6 inches going into and leaving a hole through the beam and 3 inches from entrance into the box with no connectors
@markvanbritsom42093 жыл бұрын
Not toned, it should read romex, spellcheck error
@Kudeghraw3 ай бұрын
I'm about to get into this myself. Replacing some 6 foot fluorescent lighting that may have been used to grow things by the previous owner. Going to do 5 sockets. 2 on one switch, 3 on another to split the garage. The third socket will be for the stairs leading into the garage. I want to be able to control the lights before I open the door to the garage vs having to walk in to a dark garage and try to find the holes on an outlet to plug in the fluorescents without shocking myself. I was going to try out one of those LED 3 way lights you showed at the end. They just screw right into an e26 socket as if they were a light bulb. If they suck, you can toss them and try something else.
@Jean-MichelRenaud-n6h9 ай бұрын
Great video… question? How many times can you add from one existing light?
@spencercarr433 Жыл бұрын
THANKS!!! Ended up that since we have a small area I only need the Ontel LED light!!!
@brentsaddress Жыл бұрын
Nothing oozes confidence like knowing your freshly installed lamp is working just fine without even checking when you throw the switch.
@billhandymanbill27753 жыл бұрын
I would never mix different sizes wire gauges in a circuit because of the different amp ratings of each wire. Say the yellow 12 gauge “ “Romex” (NM) goes to the electrical panel it should have a 20 amp breaker, but say it has 15 amp and say a year from now the homeowner decides to put in a new electrical panel, the electrician is going to see 12 gauge yellow wire so he is going to automatically put in a 20 amp breaker and that’s then you could be in for a problem having mixed gauges of wire on the same circuit. I would also use an electrician’s bolt cutter pliers so you don’t mangle the threads of the cut bolt, especially if it is going into a metal box or appliance. It would be help to point out on porcelain lamp fixture that the copper color screw is electrically attached to the center of the bulb socket and the silver is connected to the screw side of the bulb socket so you don’t accidentally get shocked if you touch bulb screw thread when changing the bulb, especially on the basement concrete floor.
@thatguy90453 жыл бұрын
I liked your explanation. What is ia the rule for having a loose ground wire like he did in the last light fixture box? Just tuck the ground wire back like that is fine? Thanks
@billhandymanbill27753 жыл бұрын
@@thatguy9045 Any metal electrical box must be grounded for safety reasons. Since the porcelain/plastic light fixture itself does not provide for a ground connection, simply add a green ground screw (10-32 machine thread) to the pre tapped hole in the back of the electrical box and wrap the 3/4”stripped ground wire around the screw in a clockwise turn and the screw and tighten the screw into the box. Now you have a grounded box in case a hot wire, uninsulated, “short circuit” should touch the metal box you will not get shocked. Hopes this helps.
@markvanbritsom42093 жыл бұрын
The real reason for drilling in the center of a floor joist or ceiling joist is because in most cities and townships it is a building code now not to drill or cut any load bearing joist or beam as most of a piece of woods strength is at the top and bottom 2 inches of the board, new construction will fail inspection if the inspector sees the wood cut or drilled in the top and bottom 2 inches, this is especially enforced when inspection of plumbing drain pipe installations, mark VB
@InnovaRL2 жыл бұрын
I was thinking the same thing. It makes sense what you say. The bottom and upper part of the beam is where the maximum bending stresses occurs. The center of the beam is the neutral axis and the stress is cero.
@rhoonah5849 Жыл бұрын
Great video as usual. Instead of hanging the string so your drilled holes are straight and then drawing the lines, I find it easier to just snap a chalk line. It saves a few minutes. Also, can't you put a 2x4 perpendicular to the joists and then staple the Romex to it on the side?
@waliw38413 жыл бұрын
Just curious if you discussed it in the video (maybe I didn't hear) that by using the 14 gauge off of the 12 you need to ensure it is on a 15A breaker? The circuit can only have a breaker sized for the smallest conductor rating.
@EverydayHomeRepairs3 жыл бұрын
Hi Wali, yes and you are right I didn’t call out this point which added confusion with the same circuit having 12/2 and the newly added 14/2. This specific circuit is a 15 Amp so the mixing of 12/2 and 14/2 is not best practice and can leas to confusion but not against code in my area. Check your breaker and if it is a 20 Amp on that circuit definitely pull 12/2. Thx!
@waliw38413 жыл бұрын
@@EverydayHomeRepairs Then I would most likely replace the outlet on that 2 gang at the start of the video or run the 12/2 to the light. You can see the home run is in the same box and there is a 20A outlet which at least by 2020 NEC isn't up to code as written 210.21(B3) (Can't have a receptacle with an amperage rating higher than the circuit). I should say I don't think it would ever be a problem, but if someone finishes the ceiling in there it might give them the wrong idea on what's ok to change on a breaker. Love the channel, but just making sure that people don't get into inspection issues if they replicate this exact setup. I know youtube watchers can be a pedantic bunch, but in a series of crazy bad choices by the next person this could potentially cause themselves an issue.
@EverydayHomeRepairs3 жыл бұрын
@@waliw3841 I appreciate your feedback and I think you are right on swapping out that 20 Amp receptacle for a 15 Amp to match the 15 Amp breaker for this circuit. Keep the feedback coming 👍
@georgequalls50433 жыл бұрын
First thing I noticed.
@ARrights2 жыл бұрын
Thank you for the comments. I watched it again to understand as a beginner. So the white is the 14 gauge wired to the receptacle, which is labeled 660W/250V. And the 12/2 is the new conduit. How did you all know it was likely a 15Amp circuit?
@logicalmisery3737 Жыл бұрын
Just put one of those led panel style bulbs in my basement laundry area and yeah it's a massive improvement, but it's so bright and harsh you get afterimages if you happen to glance at the light. Needs some kind of diffuser.
@EUSOUES0273 жыл бұрын
Congratulations ,i am electrician in Brazil .
@EverydayHomeRepairs3 жыл бұрын
Legal, já estive no Brasil muitas vezes. belo país e pessoas.
@armandocarriedo93543 жыл бұрын
Thank you for the knowledge you are passing on. Very simple and easy to understand. Thank you greetings from Arizona. Have a great day.
@EverydayHomeRepairs3 жыл бұрын
Hey Armando, thanks for the kind words.
@mechasmoke3 ай бұрын
Thanks for the great video! You're pretty straightforward, while giving just enough extra info to help those of us that aren't familiar with this kind of stuff
@Mark-sd7gg3 жыл бұрын
More of this please. This was great. I’m teaching myself home electric and plumbing. You are a great resource for me. I didn’t know I couldn’t run the romex under the joists. Is 12/2 better than 14/2? What’s the right and wrong way to install the metal 4” j box? All of these things I’m learning. Thank you again for putting out great content.
@connor67803 жыл бұрын
12/2 can handle more power then 14/2, most lighting circuits are 14/2 (15 Amps). You have to check your breaker to see what size you need. If the circlet has a 15 Amp breaker you need 14/2 or bigger, if the circuit has a 20 Amp breaker you need 12/2 or bigger.
@Around_The_Home3 жыл бұрын
It is not a matter if 12/2 is better than 14/2, it is as Connor said. The amperage of the breaker determines the minimum AWG of the conductors. With a 15A breaker, the smallest AWG you can use is 14. With 20A, it is 12. And with 30A, it is 10.
@stuzman523 жыл бұрын
There are two cases where Romex can be stapled directly under the joists. The cable has to be either 6/2 or 8/3. If you want to run smaller cables such as 14/2 or 12/2 then those cables have to be installed on running boards. It’s quicker to just drill holes in the joists or run the cables parallel to the joists as shown in the video.
@plangelierwot3 жыл бұрын
Interesting there is a 2 foot section on one end of my house where a bunch of romex is run side to side under the joists.
@mattfleming862 жыл бұрын
Check out the channel "electrician u" He is an electrician and has covered about everything. Geared towards training apprentice electricians. He often covers the boring stuff (code) which can prevent making safety issues and code violations. For a home-gamer like me it has been an amazing resource.
@cyrilasfrenchyaz2 жыл бұрын
Good video. I know it's light and they don't have ground but I did the exact same thing in my attic and the junction box had a screw for ground so rather than letting the wire unattached in the box I screwed it in place there.
@davidicousgregorian2 жыл бұрын
thats why people need experts to inspect work
@squirrelattackspidy11 ай бұрын
Thanks dude. My setup is pretty ghetto compared to this. Just needed to know what colored wires go what terminal.
@kommoncents00003 жыл бұрын
Scott, you are probably aware of this. For anyone else, on the light switch that EMT conduit should have been longer past the floor joist and should have a blue plastic protector at the end (I forget what there called) so the romex sheathing doesn't tear.
@EverydayHomeRepairs3 жыл бұрын
Good callout 👍 thx!
@elektro95643 жыл бұрын
Not to mention at least where I'm from romex is not allowed in conduit.
@briandillard8125 Жыл бұрын
@@elektro9564 why would romex not be allowed in conduit? 334.15 C in NEC tells you to do this in unfinished basements. And there is nothing saying it's not allowed in conduit anywhere in 334.
@philribaudo4126 Жыл бұрын
Hi there, I love your videos and one reason is that you always go above and beyond and include what is to code or what is in violation to code. Question: If your original circuit was 12 gauge yellow shouldn't you have used 12 gauge to the new light? (you used 14 gauge and isn't it a violation by connecting it to existing 12 gauge and if not an actual violation at least not best practices?)
@kw6713a Жыл бұрын
Yes it should be 12 gauge always on 20 amp. It's kind of a common fudge to use 14 gauge on lights based on the premise that lights will never draw close to 20 amps. It's not code, because someone could later rewire an outlet in that box or add one of those socket-to-outlet adapters. It's not the biggest risk in the world but could happen.
@kaisykaisy3 жыл бұрын
So a beautiful work and I really like the wire connectors you used. God bless all good people.
@frankb110 ай бұрын
Why are you switching from 12-2 to 14-2 @7:58? If this is on a 20 amp circuit, shouldn't it be 12-2 throughout?
@davidexley78583 жыл бұрын
Hi. Always sleeve the bare ground/earth/CPC cables with sleeving to prevent them shorting out on the live parts.
@Sean-Aviation Жыл бұрын
Excellent and clear video! Thanks. I'm thinking of multiple LED recessed lights hooked to a centered ceiling fan. So do I hook them all up from the fan, into a junction box and into the multiple LEDs in series? Since they only use 13W each, I assume it won't be a real issue in a single line
@BrianChristenson Жыл бұрын
Great video! Can you show a video on how to install a light switch from a pullchain light switch when two 12/2 wires go into the pullchain fixture?
@ericboss10 Жыл бұрын
EXACTLY the video I was looking for. Thank you
@ritzbitz1905 Жыл бұрын
Thanks for your great video! It was able to wire a new light into my crawlspace ! So much more light now ! Thanks 🙏🏻.
@henrysolis89963 жыл бұрын
This video is a huge help, especially the 2-to-1 connector at the first lamp.
@tsetendorjee90402 жыл бұрын
This is a very good show and we love it !!!
@pjmtts3 жыл бұрын
Judging off the size of that filter and ductwork somebody has been homegrow’n something tasty
@robertmungenast41933 жыл бұрын
nice video. but before cutting the screw put a nut on then cut the screw when you back off the nut it leans the threads
@DaveAwesome2 жыл бұрын
I was going to say as a noob, I don't know what wire to buy. I don't how many lights I can have on whatever size breaker ect. I think you showed me how to do it if I knew what I was doing with the other questions.
@thomasmayfield41417 ай бұрын
thanks for the help, my sound is out on my dell ,your advice was clear,thanks!!
@debbies61923 жыл бұрын
The information on "how to" is always useful and so much appreciated! Thank you!
@termagator Жыл бұрын
Very helpful video, thanks very much for this video. Well done
@EverydayHomeRepairs Жыл бұрын
You bet!
@eddieespinosa8743 Жыл бұрын
Thank you for making everything clear
@phillamoore157 Жыл бұрын
Great video. I think this will have helped a lot of people. I would like to have seen the Wago connectors a little better though. But, I think I got the gist of how you wired it. Thank you for taking the time.
@Californiansurfer3 жыл бұрын
I was working on customers house which they told me, when we take a shower, we get a shock or something. Well, I went under house and found bare phone line on pipe which when there was a phone call which is 40amps , they get a shock. Wow, they could of died. I always remember that service. Downey California
@SaltMinerOU8126 ай бұрын
I love the sound of the speed hammer 😂
@game-mifi Жыл бұрын
would be nice to get a close up of the wires.. can the ground copper touch other wires?
@huyp38615 ай бұрын
Do you have to pigtail it? I noticed there are 4 screws in the lamp holder. Can you just connect the 14-2 wires to the other 2 screws?
@EverydayHomeRepairs5 ай бұрын
That would work.
@StevePilgrim20133 жыл бұрын
Really useful video. The hands-on work explains what we see in our 60 year old house! Thanks!
@briandillard8125 Жыл бұрын
Don't use linesman pliers to cut the screws, your wire strippers have built in screw cutters for 6-32 and 8-32 screws
@shube3103 Жыл бұрын
Can you add another lighting run out of the same box using the empty wago connector hole?
@Wborogoal4784 ай бұрын
Can you tap into the feed before the switch box to add another switch without running to the breaker, or do you need to run to the breaker if you want your add another switch? (I don’t have a socket nearby but I do have an existing light on the other side of the wall I plan to add the switch to).
@nsoccer1811 ай бұрын
If I run multiple light fixtures, let’s say I turn off one by that pull switch, would the other lights still receive power for me to turn it on?
@jaimejovel55983 жыл бұрын
Excellent Maestro
@luisnataniel13732 жыл бұрын
Excellent video. This is exactly what I was looking for to add an additional light in my storage room that has a dark area. It's much appreciated. Keep up the good work!
@davidicousgregorian2 жыл бұрын
new codes dont allow exposed bulb fixtures especially pullchains and keyless or outlets that are on keyless lamps all bulbs must now be covered enclosed with glass or shield the shields that you can reach over or through are not even allowed all bulbs must be fully enclosed
@matthewsalvador9783 Жыл бұрын
@@davidicousgregorian does that mean I have change out my attic pull chain light? My house was built in the late 90s
@EldaLuna3 жыл бұрын
interestings indeed but what really got me going in this vid is what is with the water pipes in there.. is that really the new standard over copper? i really do not feel comfortable with that what so ever also interesting how mention that yellow wire being cut by something but i think id be more worried hitting that red hot water or blue cold water pipes around all that wiring.., i am waiting for the new sections this house i am in to rupture at any time cause they couldn't of been arsed to redo it in copper. but back to topic at hand, i didnt even know they made new electric boxes that nailed in on the side like that things surely change fast in the electric world.
@CashMoneyMoore Жыл бұрын
Awesome video, how many can you daisy chain off of one wire with these wago connectors?
@port3d2 жыл бұрын
Thanks. Exactly what I was looking for.....NICE.
@gallardojorge4763 Жыл бұрын
Hey guys, is it appropriate to use round or fork connectors from the wires to the gold and silver screws?
@weekendhomeprojects2 жыл бұрын
What's the rule for drilling into floor joists? Does drilling holes in it weaken it at all? What if you had a few projects on different sides of the basement, ok to drill through the same joist at different spots?
@davidicousgregorian2 жыл бұрын
at 1:52 if you want to keep the integrety and strength of floor joists then use a pvc to protect wires or box em in with wood or metal raceways especially if there needs to be many holes drilled to accomplish protection since code only allows so many holes allowed through rafters and joists by code also holes need to be drilled as close to center of joists as possible no closer to edge than 2 inches from edge or top and stapled every 3 feet and within 8 inches of bends and no farther than 8 inches from splice boxes also no bee lining only smooth curves and no 90s
@trevorleeanderson8 ай бұрын
Does the order in which the neutral/hots matter inside the WAGO....like left to right, right to left? Thanks!
@appleztooranges3 жыл бұрын
Nice makita drill. Just got into that platform from dewalt love it!
@EverydayHomeRepairs3 жыл бұрын
Yeah, a few months back I was debating on which platform to go with longterm but decided to still with Makita 👍👍
@Nahyoutrippin2 жыл бұрын
Great video, it helped me plan. Can I use that same principal for a ceiling fan?
@jaimecabrales85143 жыл бұрын
Thank you Sir.
@ForrestWilkinsisrad Жыл бұрын
thank you, helped me a lot.
@DirkGorgiel3 жыл бұрын
For that job I would use WAGO pushing connecters, only!
@waynet83272 жыл бұрын
I'd rather staple it than drill a hole to the wood making the wood weaker.
@vincentdeleonjr10394 ай бұрын
great well explained thank you
@jragadio2 жыл бұрын
Many wire strippers have a dedicated 8-32 and 6-32 bolt cutter that will clean out the threads
@EverydayHomeRepairs2 жыл бұрын
That is a better option as it can help to keep the threads undamaged. 👍
@cornbreadfedkirkpatrick96473 жыл бұрын
What I would like to add more light is to current living space like a living room a room and kitchen and bathroom more like recessed light
@thisjustin6150 Жыл бұрын
Thanks for the video.
@jkaramyhotmail3 жыл бұрын
What's the plastic connectors used to link the cables to the original socket? Thanks
@EverydayHomeRepairs3 жыл бұрын
They are called Wago 221 lever nuts. You can get them on Amazon or if you have a Menards in your area they also carry them.
@JeanCast Жыл бұрын
Looks good but i wouldn't connect a 14/2 wire with a 12/2 wire as its a code violation even though the light bulb would not exceed the amperage capacity of the 14/2 wire but it signals a red flag. Another issue would be at the panel as most likely there's a 20 amp breaker that is not protecting the 14/2 wire. It's best practice to stay with the same gauge all the way to the panel. Technically if you would have several lights it would work without any issue but in practice stay with they same wire throughout to avoid any issues, especially if the next owner decides to be creative and add something else to the end of the circuit....
@rickteeden86563 жыл бұрын
I just finished doing this exact project, but I ended up wrapping the wago connectors with electrical tape to make sure the levers stayed closed.
@EverydayHomeRepairs3 жыл бұрын
Yeah, I know the levers can open up a bit but I think the levers needs to really be pulled open to release the wire. Not that electrical tape is bad on WAGO 221 lever nuts but probably not needed. Thanks for the feedback
@ralphyboy38562 жыл бұрын
Always fun watching your videos very basic and simple to follow especially for us DIYers💪💪
@Wegetsignal3 жыл бұрын
Very useful information!
@EverydayHomeRepairs3 жыл бұрын
Happy to help!
@Unrealistic-o9c2 жыл бұрын
Electricians love to cut through joists, just like plumbers. It's a stinking crawlspace. Run conduit above or below joists.
@davidicousgregorian2 жыл бұрын
we know building codes related to field for structural rules you should too
@HMJKS2000 Жыл бұрын
So if the light is controlled from two switches I assume there will essentially be double the cable?
@robertjoseph15923 жыл бұрын
Did you really need pigtails at the original box? It had an additional pair of screws on the fixture to which the new 14/2 wires could be attached.
@MrFitness943 жыл бұрын
If those additional screw terminals fail somehow, both lights will fail. In addition, say this room gets completely finished, and that circuit starts getting receps, and more lights. Now all of that will fail at once. Also, in that scenario, that means 10, 12 amps could be running through those little screw terminals quite often. And although they are rated for that, most pros prefer the high loads to be run through the connection that they themselves have made, whether it’s through a wago or a wirenut
@hotrodpaully13 жыл бұрын
@@MrFitness94 I would agree on and outlet that may be the case but with today's LED bulbs a lighting circuit carry very little amps and probably never see 10 amps
@MrFitness943 жыл бұрын
@@hotrodpaully1 yeah for sure. Pigtailing isn’t even necessary ever for stuff like this. It’s just preferred thats all. One thing I forgot is it would also make swapping the fixture out in future easier
@miguelcolon89292 жыл бұрын
Will it be the same wiring procedure when installing 4 light fixtures
@steveloux47093 жыл бұрын
Although you didn't verbalize it, I saw you run your fingers on the backside of the joist before drilling. It's a good practice in case there is either Pex or romex/NM running parallel to the surface just out of sight.
@EverydayHomeRepairs3 жыл бұрын
Totally agree, around 3:00 I made a quick mention of this best practice.
@TheJoshDoes2 жыл бұрын
Super helpful video! Thanks so much!
@EverydayHomeRepairs2 жыл бұрын
You bet!
@thepeach123459 ай бұрын
@ 5:21 he says gold is hot, silver is nutrual but he then connects the dark black wire to the gold connection leaving the white to go to the neutral (neg)? just curious
@chriscutress17023 жыл бұрын
In a garage, how would you run a power line to a new fixture from an existing switched fixture without cutting into the ceiling ? In other words exposed but at the same time safe against the garage ceiling.
@elektro95643 жыл бұрын
You would have to run it on the surface in either metal or grey pvc electrical conduit. This would mean you need to put an extention box on the existing fixture, so that the box extension can have conduit attached to go to the new fixture. Remember you can't run romex in conduit, you have to buy individual wires on spools. 14 guage for a 15amp circuit and 12 guage for a 20. For wires you would need black, white and green, assuming you are in North America. If you don't feel comfortable doing this you should just get an electrician to come out, it shouldn't cost too much. And remember to turn the power off before even touching anything!
@kedso27692 жыл бұрын
Great video, you take your time to explain each step which is great for first timers like me, I'm learning a lot from you Sir! Thank you!
@Quentyn732 жыл бұрын
How do you cross across floor joists if there are ducts between them? It's funny worrying about nicking the Romex sheathing but not bulbs
@j5tan68js2 жыл бұрын
Thank you you made that very easy to understand
@elnene1748 ай бұрын
Awesome video!!!
@WonboShim3 жыл бұрын
Great video, thanks for posting. I plan to do this for my unfinished detached garage. I currently only have one fixture, so it's dark, and there are a lot of shadows.
@MarioEscobedo-e8m Жыл бұрын
Would you use a GFCI outlet in a crawlspace?
@nathanielcholewa64723 жыл бұрын
can you use both 12/2 and 14/2 wire connected together and how do you know if your existing wire is 12 or 14/2?
@EverydayHomeRepairs3 жыл бұрын
In this case technically I could since it was on a 15 Amp breaker. Probably just best to stay consistent. If you have a 20 Amp breaker and the wire is 12 gauge stick with 12 gauge. You can compare your existing stripped wire (just the copper) to a dime or a nickel. If the wire is the same thickness of a dime it is 14 gauge if it is the same thickness of nickel you are working with 12 gauge.
@justaguyonthefly Жыл бұрын
How many lights could a person add using this method? Would 3 be ok or no?
@ninawade30553 жыл бұрын
Very nice!
@EverydayHomeRepairs3 жыл бұрын
Thanks!
@budgetaudiophilelife-long54613 жыл бұрын
🤗 been there, done that the right way…💡 IT WAS A VERY ENLIGHTENING EXPERIENCE AND WELL WORTH THE EFFORT THANKS SCOTT FOR SHOWING OTHERS HOW TO 👍😍😍😍
@jameskappel3 жыл бұрын
Hello, I do not find a link to Scott - the"multi-head led arrays that can adjust"?
@EverydayHomeRepairs3 жыл бұрын
This is the one featured at the end www.amazon.com/Ontel-Beyond-Bright-Ultra-Bright-Garage/dp/B085LSY9CM?crid=1D57WGK1F3V1C&dchild=1&keywords=LED+garage+light+array+bulb&qid=1634952434&s=hi&sprefix=led+garage+light+array+bulb,tools,165&sr=1-17&linkCode=sl1&tag=dixon41431-20&linkId=db119c6db4de98563be0c9076c34b0fb&language=en_US&ref_=as_li_ss_tl