How to bypass a Defrost Heat Pump Board to allow cooling

  Рет қаралды 290,904

SuperCool Slide Rule

SuperCool Slide Rule

Күн бұрын

www.supercoolsliderule.com -- This video tutorial illustrates how to set up a defrost heat pump board to bypass for cooling. To set up to bypass for cooling, one simply needs to follow these steps on a defrost heat pump board.

Пікірлер: 78
@michaelcostello6991
@michaelcostello6991 6 жыл бұрын
Good video. It clarifies the functions of the defrost board and the fact that it is just needed really for heating and some safety interlocks
@btknowlton
@btknowlton 9 жыл бұрын
If you have comments that are helpful or suggestions on how to improve a video please post it but if you don't have anything valuable to add then please keep it to your self.
@mickeylojkar5769
@mickeylojkar5769 5 жыл бұрын
Why get a common from the board if your bypassing the other wires? Shouldn't you get common from the tstat wires?
@1251PrintHouse
@1251PrintHouse 2 жыл бұрын
Yes you should.I was thinking the same thing
@christopherpaul2938
@christopherpaul2938 9 жыл бұрын
Bryan the way you ecplained it is for.experienced technicians, it seemed a bit confusing, the easiest way would be to just unplug the two orange reversing valves wires from the defrost board and simply connect them on the each side of the contactor so the valve can get its 24 volt. The valve will always be energized when ever there is call for cool. Great vedeo though!!
@SombraLocs
@SombraLocs 9 жыл бұрын
exactly!
@michaelkranz2529
@michaelkranz2529 7 жыл бұрын
Ya I think this guy want's to show off his electrical engineering degree , but any tech can do that task in way less moves than his dumb ass video , Oh ya , why are we bypassing the control anyway ?
@Seawolfvital
@Seawolfvital 7 жыл бұрын
Christopher Paul what if condenser fan motor relay stuck open? U energized reversing valve but cond fan motor won't run. I would never bypass defrost bord(SW Florda) unless it's late call and I'm unable to get replacement part (most cases -next day in the morning it is installed).
@osiriscorporation1265
@osiriscorporation1265 6 жыл бұрын
simplicity at its finest, thanks smart brother!!
@PBS-nm1uu
@PBS-nm1uu 7 жыл бұрын
please do one on how to read the control board.
@aadilali1510
@aadilali1510 7 жыл бұрын
THANK U SO MUCH
@914peru
@914peru 10 жыл бұрын
thanks for you help I'll buy you slide rule I'll buy my defrost board in October
@OnePointLander
@OnePointLander 2 жыл бұрын
Why would a defrost board fail?
@jeffjula
@jeffjula 2 жыл бұрын
because it's a man-made item.
@michaeljennings3485
@michaeljennings3485 6 жыл бұрын
Good video but when you connected the common lead for the thermostat you connected it to the black lead on the board and not to the thermostat wire I think it was the grey wire
@ricoswavae512
@ricoswavae512 3 жыл бұрын
Yeah i saw that too, good catch.
@aarongreen8784
@aarongreen8784 10 жыл бұрын
Okay, in the beginning you moved the black (C) wire out the way, @ 1:43 to 1:53, and tried to put the red wire from the contactor to the light blue (C) wire from the thermostat. Then later you put the black (C) wire from the board with just the red and orange (C) wire and the light blue (C) wire was not connected. Now which wires need to be connected in that stage? All light blue, black, red and orange which equals four wire or does just three need to go together, black or light blue with red and orange?
@drouse365
@drouse365 5 жыл бұрын
Aaron Green Just the light blue,orange, and red. Forget the black coming from molex plug (board).
@zmanjz2001
@zmanjz2001 3 жыл бұрын
Great tutorial my Board went out. It's on backorder and it's been 102° here. This worked great and the temp is dropping as I type. Thank you!!
@Alienspecies635
@Alienspecies635 2 жыл бұрын
I’m about to try this tonight for a customer that got a bad board on a new unit 🤦🏻 3-5 days for the board to get in then I have to go pick it up and install it
@michaelpope2946
@michaelpope2946 5 жыл бұрын
Shouldn't you connect to the valve end of the orange wires not the board end? I tried this and burned up my transformer not sure what I did wrong.
@boobieloc9734
@boobieloc9734 3 жыл бұрын
That's what I'm thinking.. because how would it power the valve. why wire the board if you're bypassing board
@matthewcrews4034
@matthewcrews4034 3 жыл бұрын
Hi how are you can you make a video .showing how to bypass the condensor fan relay on board for defrost and add and external relay to allow cooling and heat I've replaced this carrier board 3 times in a year and a half .just put a new board and new condensor fan motor just in case old fan motor was pulling to high of laps causing the relay to fail . However the board failed a week later anyway I've had the whole system checked over and voltage tested they found no issues but the board keeps failing the last unit I had the man installed a external relay for the fan which worked perfect until I had to get a new unit due to outdated freon thanks and I hope you can help
@Onatena
@Onatena 4 ай бұрын
thanks for this great Video I was struggling with one heat pump I was getting 24v but the board was not working well, after watching this video I end up bypassing it and it worked 😂
@outlawguitar1
@outlawguitar1 9 жыл бұрын
Something wasn't right, I wired it exactly after spending an hour repeating the steps, plugs mine in and 60 seconds later, a loud pop!!! Maybe redo this video and rethink the wiring and be a little more in detail, thanks
@JuanDiaz-vm1pv
@JuanDiaz-vm1pv 4 жыл бұрын
Thank you for your time. Question: my AC/Heat Pump is freezing up around the indoor unit coil. No AC at all. Thermostat and inside fan are working, filter and A-frame are clean, drain plug is NOT clogged. Outside fan and compressor are working too. I haven't measure capacitance, but assume dual capacitor is good since compressor and fan both run. I haven't check for low refrigerant yet (R-410A). What could possibly be the problem? Would the defrost control board have anything to do here (it's spring time and only inside is freezing). Thank you much in advance!
@bhaskarper909
@bhaskarper909 2 жыл бұрын
What did you do to fix it, I have similar problem?
@musclemoney4479
@musclemoney4479 2 жыл бұрын
@@bhaskarper909 low refrigererant
@DJatVRR
@DJatVRR 9 жыл бұрын
You should make another video with a more simplistic explanation of a simplistic solution and correct your mistake while you're at it.
@davidjackson3069
@davidjackson3069 2 жыл бұрын
You just cut half the words in the unit when all you had to do was run the "Y" wire directly to the contactor. Land the fan wire on the L1 terminal of contactor. Then you could have placed a common wire on the opposite side of the contactor and boom when the contactor pulls in you have air conditioning now you have to unspice all those wires and fix it all back ridiculous amateur status.
@johnj2496
@johnj2496 11 ай бұрын
what about the reversing valve wire just move the input wire down to the extra connection next to the yellow control wire on contactor
@sultanramza9379
@sultanramza9379 8 жыл бұрын
Thank you for this video. I followed the steps and it worked perfectly. Just two issues I'd like to highlight to help others: 1. Please refer to the wiring schematic for specific colors of the reversing valve. Mine were black. 2. Also I blew the fuse at the a/c handler in this process so my thermostat wasn't working. One I found that and replaced it everything worked well.
@glennthompson1620
@glennthompson1620 2 жыл бұрын
SMerry
@Ajax2341
@Ajax2341 6 жыл бұрын
Thank's Good Video. Ive worn out a couple of supercool slide rule already. a lot of information on that card. I use it all the time.
@herbertvega749
@herbertvega749 3 жыл бұрын
Good job !!!!! thank you for sharing !!!!!
@manna5610
@manna5610 10 ай бұрын
So, I wanted to bypass the defrost board for heating, then just leave the reversing as is.
@TalentNetworked
@TalentNetworked Жыл бұрын
Great videos. Can an ohms OL on a Solenoid cause the 3amp fuse in the AH to keep failing? Can’t get Low Voltage on Contactor, changed contractor, same issue.
@RifullOfTheWest
@RifullOfTheWest 6 жыл бұрын
@SuperCool Slide Rule" can you make a video on how to make yourself a light wieght, small home built window defogger wire setup. I have a velomobile I need to make a defogging wire setup, but can't figure out how to do it, and where to get the wire.
@hg2.
@hg2. 6 жыл бұрын
Not good for beginners. "Don't do this at home.
@chadoxdcfan
@chadoxdcfan 4 жыл бұрын
Could I just jump yellow and orange and leave common alone? Shouldn't common still be present no matter what?
@sarahgracebrooks2629
@sarahgracebrooks2629 8 жыл бұрын
What if you don't have a RV and your indoor fan is wired with the unit....Package/A/C and GAS??
@louisg4567
@louisg4567 10 жыл бұрын
you right Aaron he messed up.. the red wire from the contactor is suppose to connect to the common on the thermostat wire coming from the air handler and that completes your 24v coming from the transformer the other yellow wire which is your call for cooling he has correct
@nitrofan917
@nitrofan917 5 жыл бұрын
Do the red and blue wires that you jumped get plugged back into the relay? Thanks.
@viper22304
@viper22304 5 жыл бұрын
Thanks for the video. Can you do this with rudd and rheem?
@ricoswavae512
@ricoswavae512 3 жыл бұрын
Yes you can.
@trickyanims7852
@trickyanims7852 8 жыл бұрын
Basically just take the low voltage cooling wire out of the board and connect it at the contractor. 🆒
@RM-gw8ue
@RM-gw8ue 4 жыл бұрын
How can you bypass the control board and still retain the ability to use the heat strips ?
@romeshthomas7949
@romeshthomas7949 7 жыл бұрын
How to wire up a hot water coil to an air handler using two relays and an aquastat
@kaster2014
@kaster2014 4 жыл бұрын
Good video ... but very bad explanation
@andrewlaurice8227
@andrewlaurice8227 10 жыл бұрын
Great information! Thanks. Andrew Laurice
@gotchaplumber
@gotchaplumber Ай бұрын
Great video!
@manuel12888
@manuel12888 2 жыл бұрын
Thank you so much for your help
@gotchaplumber
@gotchaplumber 6 ай бұрын
Great video!
@danpan4425
@danpan4425 6 жыл бұрын
Can you bypass the board for heating and cooling?
@Ggg77777
@Ggg77777 3 жыл бұрын
Yes but different way
@abnergallo6960
@abnergallo6960 Жыл бұрын
Thank you so much
@giorgioguidolin
@giorgioguidolin 3 жыл бұрын
Thank you
@saltrue1555
@saltrue1555 7 жыл бұрын
Nice tks
@Carskinify
@Carskinify 9 жыл бұрын
The defrost cycle doesn't work during the summer so if you just use the summer ac,why would you need to bypass the defrost cycle?
@acoustic4037
@acoustic4037 9 жыл бұрын
Carskinify You don't "bypass the defrost cycle" as you put it. You bypass the defrost board. The board can burn out (a relay on the board) and not pass power (24v) to energize the main contactor and not allow the system to run or cool at all. I'm still new at hacks so I just get the replacement board and install it. People go hot for a few days, thats life.
@foghornleghorn8536
@foghornleghorn8536 9 жыл бұрын
acoustic4037 Sounds like you should probably be doing installs. Leave the service work to an actual technician.
@acoustic4037
@acoustic4037 9 жыл бұрын
Foghorn Leghorn your comment serves no purpose except to insult. Why bother if you can't be constructive or helpful.
@foghornleghorn8536
@foghornleghorn8536 9 жыл бұрын
Merely pointing out that by making this statement "People go hot for a few days, that's life." You clearly indicated that you should not be a service technician.
@WilliamBelliard
@WilliamBelliard 9 жыл бұрын
I enjoyed your video thank you for the education, I do have a question. I have a temp star unit and I replaced the contractor, defrost board and fan board along with a new honey well digital thermostat. All looks well, the ac blows cold air but I did notice that the condenser fan is always running/spinning even when the blower inside is not blowing anything. Also the air power of the air coming out of the vents inside is not as strong and the other units. Can you please help
@btknowlton
@btknowlton 9 жыл бұрын
William Belliard You may want to ensure that the wires feeding the condenser fan are connected to the load side of the contactor instead of the line side (they should be on the side opposite the incoming high voltage wires). Hope this helped.
@WilliamBelliard
@WilliamBelliard 9 жыл бұрын
Bryan Knowlton Thank Bryan. Is the load side L1 or L2 correct? I mean have you heard of this? Could the fan motor be bad as well? Or if it spins that means its good. By making these changes will it increase the speed of the fan outside thus increasing the air blowing inside?
@michaelkranz2529
@michaelkranz2529 7 жыл бұрын
Oh ya , if you can speed up the out door fan , it will surely blow like hell inside , dude stay away from this trade , your scaring me .
@luishernandez5394
@luishernandez5394 Жыл бұрын
Sounds like you wired the low voltage incorrectly and by that I mean maybe at the furnace you installed the y wire on the r terminal instead of it being on y and therefore your your condenser is always running. Or you wired your fan high voltage going too the line side of your contactor that you replaced something is mis wired need more input.
@OcRefrig
@OcRefrig 6 жыл бұрын
Good video !
@BradMillsXRP
@BradMillsXRP 9 жыл бұрын
I tried this and it burned my house down. So my laywer is wanting your General Liability policy number
@michaelkranz2529
@michaelkranz2529 7 жыл бұрын
Excellent reply , I love it , people like him don't realize that people shouldn't be attempting modification like that , leave it to qualified service company , I would sue the shit out of him , he is an accomplice to disaster.
Troubleshooting the Goodman Defrost Board
14:52
John Jennings
Рет қаралды 84 М.
Heat Pump Troubleshooting- Defrost Board Testing and Bypass for Cooling!
12:32
AC Service Tech LLC
Рет қаралды 448 М.
Brawl Stars Edit😈📕
00:15
Kan Andrey
Рет қаралды 57 МЛН
Как подписать? 😂 #shorts
00:10
Денис Кукояка
Рет қаралды 8 МЛН
Ozoda - Lada (Official Music Video)
06:07
Ozoda
Рет қаралды 14 МЛН
The Sequence of Operation for a Defrost Heat Pump Board
9:30
SuperCool Slide Rule
Рет қаралды 224 М.
Trane Heat Pump with Bad HPS, Diagnosed! #hvac #airconditioner #heating
11:46
Jeff’s HVAC Adventures
Рет қаралды 22 М.
Heat Pump Reversing Valve Troubleshooting Tips (Switchover Valve)
10:43
Fox Family Heating and Air Conditioning
Рет қаралды 148 М.
Testing Pressure Switches on Condensing Units
4:38
Tec Tube
Рет қаралды 110 М.
Troubleshooting a Bryant Defrost Board
12:55
John Jennings
Рет қаралды 22 М.
How a Heat Pump Reversing Valve Works
6:10
HVAC School
Рет қаралды 759 М.
DIY Vapor Compression Refrigeration System
28:06
Hyperspace Pirate
Рет қаралды 1,1 МЛН
HVAC  076 Pressure Switch Refrigerant
16:34
Love2HVAC with Ty Branaman
Рет қаралды 44 М.
Return to Freezing Heat Pump to Change Defrost Board!
10:16