How to Calculate and Measure Motor RPM/Speed using Mitsubishi PLC and Photo Sensor Urdu||Hindi

  Рет қаралды 33,510

Automation House

Automation House

Күн бұрын

Пікірлер: 55
@DàvidNewton-u7q
@DàvidNewton-u7q 3 ай бұрын
Just what i need to finish a project , thank you it has saved me a lot of time as i have never had to program a high speed counter before.
@hisyst
@hisyst Жыл бұрын
very good nice and fantastic 9 jawan .
@md.rashedalam4336
@md.rashedalam4336 3 жыл бұрын
আসসালামু আলাইকুম(asalamualiku) so nice a simple program...thanks a lot. Brother
@METHEE.C
@METHEE.C Жыл бұрын
I have 10 pulse/ 1 cycle can we can div10 before calculation?
@AliiSajid
@AliiSajid 3 жыл бұрын
x0 k lea apne c235 le liya hy, agr hum x1 ya x2 le lein tb knsa counter lengy?
@automationhouse8613
@automationhouse8613 3 жыл бұрын
Depends on PLC model u can see manual for relevant High speed counter...
@sandeepthorvat6395
@sandeepthorvat6395 3 жыл бұрын
sir Schneider plc me ye same program batado na moter speed measure ka
@ahmedmohamedhassan1033
@ahmedmohamedhassan1033 4 жыл бұрын
Thank why you did not use SPD function to calculate speed
@automationhouse8613
@automationhouse8613 4 жыл бұрын
This is simple way that's why i consider this technique but will share SPD command in coming videos as well.
@santhanavel6816
@santhanavel6816 4 жыл бұрын
Sir please can you explain speed detection function in fx5u
@automationhouse8613
@automationhouse8613 4 жыл бұрын
Just use high speed counter same as Mitsubishi other series
@santhanavel6816
@santhanavel6816 4 жыл бұрын
In fx5u series c235 its does not working on it.. so please tell c235 is high speed counter of fx5u or any other counter function to be using.. please mentioned it..
@arifwid
@arifwid 3 жыл бұрын
Sorry sir. For input x0 in ladder nothing? Where is it? Thank you very much
@automationhouse8613
@automationhouse8613 3 жыл бұрын
This is special high speed counter that dedicated for x0 u don't need to use x0 in program while using its dedicated counter..
@arjunjayswal6347
@arjunjayswal6347 2 жыл бұрын
Thank u sir
@tradingbaba4894
@tradingbaba4894 Жыл бұрын
Sir Jo ladder aapne banaya h usko mene simulation me chala kar dekha lekin mere me timer or counter Dono reset ho jate h T0 ke operate hote hi lekin rpm D0 me show nhi hota
@kokokafi
@kokokafi 2 жыл бұрын
Assalamualaikum. I so confused about how to positioning with mitsubishi plc using expansion qd75d, can you explain about positioning?
@industrytvpakistan2569
@industrytvpakistan2569 3 жыл бұрын
Dear sir which photosensor you are using??
@ajayrawat9525
@ajayrawat9525 4 жыл бұрын
Kindly teach analogue programming
@automationhouse8613
@automationhouse8613 4 жыл бұрын
Find more videos on channel i have already uploaded videos on analog signal using delta PLC...
@abdullahsiddiqawan9100
@abdullahsiddiqawan9100 4 жыл бұрын
Aoa Sir what is the price of plc trainer want to upgrade siklls i am a student of electrical engineering.
@automationhouse8613
@automationhouse8613 4 жыл бұрын
For purchasing any Instrumentation product contact me on my wtsup +923155368813
@AreebAhmed08
@AreebAhmed08 4 жыл бұрын
Excellent video sir. But i have a problem. we have dc motor of 90kw and its original analog rpm meter faulty and not availible. We are using yaskawa dc motor with techometer and connected in dc drive. now how can we measure rpm of motor. Please help. i didnt find any relevant topic in youtube or internet. Techometer output mein dc voltages deraha hai jo drive se connecr hai.
@automationhouse8613
@automationhouse8613 4 жыл бұрын
How much DC voltage are output from techometer?
@AreebAhmed08
@AreebAhmed08 4 жыл бұрын
@@automationhouse8613 3 to 5 vdc
@ajayrawat9525
@ajayrawat9525 4 жыл бұрын
Nice sir
@automationhouse8613
@automationhouse8613 4 жыл бұрын
Thank you for your appreciation...
@alaminkhan965
@alaminkhan965 Жыл бұрын
Boss encider to analog output 10volt program bana do
@lockercoin3693
@lockercoin3693 4 жыл бұрын
assalamualaikum brother. i am not from india so i cant undertsand what you were trying to explain. Would you please send me the pdf file so that i can learn from you? thanks :)
@automationhouse8613
@automationhouse8613 4 жыл бұрын
W/slam dear Yes for sure.. share your email..
@lockercoin3693
@lockercoin3693 4 жыл бұрын
@@automationhouse8613 thank you for your reply brother. i sent you a feedback from my email :)
@automationhouse8613
@automationhouse8613 4 жыл бұрын
Ok brother
@automationhouse8613
@automationhouse8613 4 жыл бұрын
@@lockercoin3693 Sorry dear i didn't received any email from your side till now.. email me on muhib.khan068@gmail.com or autmation.house068@gmail.com
@aldyfebriansyahakbar162
@aldyfebriansyahakbar162 2 жыл бұрын
@@automationhouse8613 assalamualaikum brother, would you please send me the pdf file too, thanks for explain in this video
@mohanrajm439
@mohanrajm439 4 жыл бұрын
RPM WILL updated every one minute . can i get rpm like tacho meter.
@automationhouse8613
@automationhouse8613 4 жыл бұрын
You can get in every second too watch video till end..
@ramsharma3772
@ramsharma3772 2 жыл бұрын
Sir एक ही PLC मे 1 से अधिक मोटर के RPM की प्रोग्रामिंग करनी हो तो कैसे करेंगे
@maruthuraj7960
@maruthuraj7960 4 жыл бұрын
We have to use latched data registers for this operations... If we use general data registers, it will not work... Am i right ....
@automationhouse8613
@automationhouse8613 4 жыл бұрын
Sorry u can use any general data register. Latched data register not mandatory...
@AreebAhmed08
@AreebAhmed08 4 жыл бұрын
In fx plc all data registers are latched type. For Q series plc you need to assign special latch type data registers
@automationhouse8613
@automationhouse8613 4 жыл бұрын
@@AreebAhmed08 latch data register may very model to model in fx series but in fx 3u latch data register start from D200
@AreebAhmed08
@AreebAhmed08 4 жыл бұрын
@@automationhouse8613 I was talking about fx 3g . all data registers are latched type
@automationhouse8613
@automationhouse8613 4 жыл бұрын
@@AreebAhmed08 No dear not all data registers are latched some r latched nd some r general purpose check datasheet also latch data registers quantity can be define through parameters setting ...
@shibarammazumder309
@shibarammazumder309 3 жыл бұрын
can i calculate PPR(pulses per rotation ) using a proximity sensor of a roller?
@automationhouse8613
@automationhouse8613 3 жыл бұрын
Try to use photo sensor but u can use proximity if working perfectly
@rivalfahrurizki4562
@rivalfahrurizki4562 3 жыл бұрын
How if we want to know speed in m/min ?? What's the programs ??
@automationhouse8613
@automationhouse8613 3 жыл бұрын
First u have to use encoder for sensing area then u calculate pulses per unit area then u can apply sone calculation for finding m/min
@mrityunjaykumar5407
@mrityunjaykumar5407 11 ай бұрын
Good
@mhayatkhanhayat8714
@mhayatkhanhayat8714 3 жыл бұрын
Nice
@wallstreet497
@wallstreet497 2 жыл бұрын
SPD ???
SC06b. Calculate Motor Speed RPM via Siemens S7-1200 HSC(High-Speed Counter) and Encoder
11:45
Каха и дочка
00:28
К-Media
Рет қаралды 2,8 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 152 МЛН
How to measure RPM in PLC Program ? High speed counter || PLC Programming
7:55
PLC Programming Tutorials Tips and Tricks
Рет қаралды 29 М.
Mastering Belt Conveyor Motor Selection and Calculation: Ultimate Guide
23:36
Master Mechanical DESIGN
Рет қаралды 71 М.
Sudden assault near Kursk / Putin's statement
13:04
NEXTA Live
Рет қаралды 472 М.