How to Calculate your Heater Wattage (Get your target temperature)

  Рет қаралды 73,594

DwyerOmega

DwyerOmega

Күн бұрын

Пікірлер: 53
@blender_unleashed
@blender_unleashed 3 жыл бұрын
So difficult to find info on the internet these days. You really helped me
@Presso99
@Presso99 3 жыл бұрын
can you please open up a subject on the design of heating coil for roaster?
@dominiksavli3285
@dominiksavli3285 4 жыл бұрын
Well, it gives somehow the right idea, but it should be devided by time, not multiplied by time. Either that or correct use of parenthesis is required to repair your equation.
@kevinnazeraj1799
@kevinnazeraj1799 3 жыл бұрын
Exactly because kw=power=kjouls/s
@maheshpinnam5171
@maheshpinnam5171 Ай бұрын
Brother, i have a lithium ion lfp battery in ABS container size 25.2 x 26.5 x 27 cm with 0.6 cm thickness with exact lid with 0.8 cm thickness. Weigh of container is 2.91 kg.. how to calculate the heater pad wattage to bring -40 deg c temp to 0 deg c, pls help
@mustaqeemshaikh7839
@mustaqeemshaikh7839 4 жыл бұрын
How to calculate solar heat intensity (I) W/m2? Any theoretical formula?
@vinaykumarmaurya6288
@vinaykumarmaurya6288 2 жыл бұрын
Sir can you please give me a suggestion to how consider the TCU (TEMPRATURE CONTROL UNIT) for the rubbery Extruder please please please please please please
@DwyerOmega
@DwyerOmega 2 жыл бұрын
Thanks for asking! Contact one of our engineering experts at: temperature@omega.com
@UrBaNMCPaladinZ
@UrBaNMCPaladinZ 4 жыл бұрын
You're a blessing my friend
@SalmanAnsari-ce6nx
@SalmanAnsari-ce6nx Жыл бұрын
I need to heat water with mch heaters but there is a problem i don't understand that how much power i have to give to it
@mehreenkanwal2170
@mehreenkanwal2170 Жыл бұрын
very good way of explanation,,, can you plz guide to any video or link for calculating time needed to heat metal from 20 celcius to 100 celcius, 50mm sqaure aluminum pipe, 2mm wall thickness,, 1 meter long,, in closed chamber or oven (lhw 1,5 x 0,25 x 0,25m), having constant heat source, 100 watts heating element,, and some air circulation.
@travellingwithvagabond8688
@travellingwithvagabond8688 Жыл бұрын
What will be the solution for -20 C and for 8000 meter lenght pipe line?
@DwyerOmega
@DwyerOmega Жыл бұрын
For consultations please contact our Heater Department at heaters@omega.com.
@rajbirsaini9838
@rajbirsaini9838 Жыл бұрын
Good bro i know it already because, i am furnace manufacturer
@carljustinepadlan7368
@carljustinepadlan7368 Жыл бұрын
What if Im gonna calculate for the wattage of a liquid chemical. Do I need to calculate for the volume of the tank not the weight.
@DwyerOmega
@DwyerOmega Жыл бұрын
For this you will need to use the formula Q = m*c*∆T. Q (joules); m (mass of chemical); c (specific heat of chemical); ∆T (change in temperature °C). Then convert joules to watts.
@aliasger.kalolwala
@aliasger.kalolwala 3 жыл бұрын
hey i am unaware of the BTU conversion for the specific heat of aluminium that you used. The aluminum i am using has a Cp of 714.8J/kg.K and deltaT is 110C and 1hr heating time....can you please help with this?
@donnymontreano2045
@donnymontreano2045 2 жыл бұрын
convert the delta celcius into Kelvin
@seniordesign3830
@seniordesign3830 4 жыл бұрын
I want to heat a nichrome coil so I can boil water, I want it to reach 200 C degree in a minute Can I use your equation to know how much power do I need ???
@naveenkumarful
@naveenkumarful 4 жыл бұрын
Hi, I want to calculate kw for a tempering furnace, where my load is 250 Kg, material is iron, max temp 660 deg, soaking time 120 min Please suggest
@DwyerOmega
@DwyerOmega 4 жыл бұрын
Thank you for your inquiry. You still need to know your Starting Temperature to get your Delta Temp°F (Target (660°) - Starting (?°F). Iron has a specific heat of 0.108 Btu/lb°F. Use the same equation shown in the video.
@mubashirislam2791
@mubashirislam2791 2 жыл бұрын
I want to make heaters for my plastic extruder Bailer dia 23.5 inches Where my starting temp 30 °c And required temperature 300°C Applied voltages 440 v ac Which no of wire I can use and how long plz tell me
@DwyerOmega
@DwyerOmega 2 жыл бұрын
Hello and thanks for your question! It depends on the wattage rating for the heater you are building. Wire gauges have ampere limitations that can be found in the table on this data sheet from Omega: assets.omega.com/pdf/cable-and-wire/heating-wire/NI80.pdf
@robertogabriel6430
@robertogabriel6430 4 жыл бұрын
Very good, thank You!!!
@mayneac
@mayneac 8 ай бұрын
Based on your formula heater wattage increases with increased heat up time? Should it not be the opposite? More power would heat up the same volume faster, not slower?
@mayneac
@mayneac 8 ай бұрын
Finally figured it out despite your application engineer refusing to help - the second half of the equation is missing a parentheses, duration (h) should be in the denominator as well).
@santanudhar3382
@santanudhar3382 4 жыл бұрын
How to calculate the wattage required to heat a tank containing liquid at a given temperature?
@donnymontreano2045
@donnymontreano2045 2 жыл бұрын
Water = 1 kg CP = 1.001 BTU/lb F Delta temp = 78F - 100F= 22F Hour = 1 ((1 x 1.001 x 22F)/3412) x 1 hour = 6.45 watt
@josephsun7783
@josephsun7783 2 жыл бұрын
the correct formula should be Kw= (5.0X0.21X90)/(3421X1), or (5.0X0.21X90)/3421/1
@nikpik9584
@nikpik9584 2 жыл бұрын
the second one
@stevequate1797
@stevequate1797 2 жыл бұрын
Still can’t figure it out, I’m stupid I guess, I just need to know how hot a silicon rubber mat 3/6” thick with heater element wound throughout the mat 2”x 5” 120v and 50 watts, the average temp of inside house is 68 degrees, don’t know everything you need to figure out problem thanks I’ll keep searching
@axelateon1384
@axelateon1384 5 ай бұрын
yeah you are totally stupid
@astrofamily6081
@astrofamily6081 2 жыл бұрын
Weight or Mass?
@hussamridan7872
@hussamridan7872 3 жыл бұрын
In the case of muffle furnace What should the weight of material and specific heat be ? Please i need a help
@DwyerOmega
@DwyerOmega 3 жыл бұрын
Hello Hussam, thanks for your question! In the case of a muffle furnace, you would use the Free Air Heating Equation: Kw = (SCFM x Temperature Rise °F)/3000
@ganeshlokare1552
@ganeshlokare1552 4 жыл бұрын
How you selected conversation factor?
@DwyerOmega
@DwyerOmega 4 жыл бұрын
Thank you for your inquiry. The conversion factor is used because kilowatt-hour is a standard unit of electricity production and consumption. However the relationship between the kilowatt-hour and the BTU depends on which "BTU" is used. It is common, but not universal, to use: 1 kWh = 3412 BTU
@deitmagnet947
@deitmagnet947 Жыл бұрын
@@DwyerOmega isn't it BTU be converted to kilojoules? And watts is a unit of power wherein it's in J/s
@SalmanAnsari-ce6nx
@SalmanAnsari-ce6nx Жыл бұрын
Hello sir i need your help
@NIRVANA_1182
@NIRVANA_1182 Жыл бұрын
I fucking love you dude
@sandeepjatin1593
@sandeepjatin1593 2 жыл бұрын
Sir furnace ka kw and heater sulection
@thesciencefurry
@thesciencefurry 4 жыл бұрын
OMG That's exactly what I need! thx
@lambajilamba802
@lambajilamba802 4 жыл бұрын
In closed vessel medium air formula???
@DwyerOmega
@DwyerOmega 4 жыл бұрын
Thank you for your inquiry! We have our generic air flow formula: kilowatts = SCFM x (Target - Starting Temperature °F) / 3000 If you need more information, call or chat online at omega.com and speak with one of our Application Engineers.
@pratheeshtom4758
@pratheeshtom4758 4 жыл бұрын
I CALCULATED MANY TIMES IN DIFFERENT CONFIGURATION ALSO INCLUDING YOUR EQUATION ITS WRONG AND PLEASE REVISE
@wilsonraj8770
@wilsonraj8770 4 жыл бұрын
No audio re record it
@jimh6189
@jimh6189 4 жыл бұрын
LOL He conveniently uses 1 hour heat up time so his error does not show up in the calculation. Someone is playing a joke on you - to the detriment of the company. Don't blame this guy- he's just an actor.
@axelateon1384
@axelateon1384 5 ай бұрын
lmao
@taboosaboo
@taboosaboo 3 жыл бұрын
3412?
@MariaHernandez-ml3tq
@MariaHernandez-ml3tq 3 жыл бұрын
It's a conversion Factor, BTU/kWh
@muchlisrifai2831
@muchlisrifai2831 4 жыл бұрын
NOICE
@jimh6189
@jimh6189 4 жыл бұрын
What about heat loss? I think this equation (the equation he is trying to make) is based on a perfectly insulated system with no heat loss. Surely on a cold day it's going to take much more heat than this. This really gives a bad name for "Engineering" especially when "Omega" is attached. I think the 95 "Thumbs up" are from Omega employees. I would check other sources before I trusted any information from this (Omega) site.
Understanding thermocouple color codes and types
1:42
DwyerOmega
Рет қаралды 4,3 М.
Power Supply Calculations - HWFCI
12:30
LetsCutFoam
Рет қаралды 96 М.
Life hack 😂 Watermelon magic box! #shorts by Leisi Crazy
00:17
Leisi Crazy
Рет қаралды 80 МЛН
怎么能插队呢!#火影忍者 #佐助 #家庭
00:12
火影忍者一家
Рет қаралды 47 МЛН
How to whistle ?? 😱😱
00:31
Tibo InShape
Рет қаралды 17 МЛН
Хасанның өзі эфирге шықты! “Қылмыстық топқа қатысым жоқ” дейді. Талғарда не болды? Халық сене ме?
09:25
Демократиялы Қазақстан / Демократический Казахстан
Рет қаралды 345 М.
How to Calculate Heat
7:57
Valin Corporation
Рет қаралды 13 М.
Cooling Load Calculation -  Cold Room hvac
14:10
The Engineering Mindset
Рет қаралды 412 М.
RTD vs. Thermocouple: Which Temperature Sensor is Best?
3:32
Always Secured Automation
Рет қаралды 255
Flow switches and Switche Types
2:59
PLC FOLDERS _A COLLECTION OF INNOVATION
Рет қаралды 347
Printed PTC Heaters and how they work.
1:31
Butler Technologies Inc.
Рет қаралды 17 М.
Winding A Kanthal Heating Element For A DIY Heat Treatment Oven
3:06
I Build It Scrap Bin
Рет қаралды 67 М.
Life hack 😂 Watermelon magic box! #shorts by Leisi Crazy
00:17
Leisi Crazy
Рет қаралды 80 МЛН