How to Change Out a Recloser

  Рет қаралды 47,151

T&D World

T&D World

Күн бұрын

Пікірлер: 20
@ElectroTree01
@ElectroTree01 2 жыл бұрын
The supposed strengthening of the guy wire was actually just another fiberglass extension rod being added as the guy wire would be near the live terminals on the recloser
@roosterkerr1780
@roosterkerr1780 4 жыл бұрын
We haven’t been able to uncraddle a truck in years without sleeves and gloves . Im real suprised to even see a company that does allow it. I sure miss it.
@SFoley990
@SFoley990 4 жыл бұрын
The small transformer is a potential transformer, it drops the line voltage from 7200 VAC to 120 VAC for control power.
@hardmarine
@hardmarine 8 жыл бұрын
Good job on that thumbs up, Eric!
@moisesaguilar7591
@moisesaguilar7591 5 жыл бұрын
What brand is the recloser?
@michaelgagne1911
@michaelgagne1911 3 жыл бұрын
Your vids are fantastic thank u
@AriBenDavid
@AriBenDavid 7 жыл бұрын
Why was the recloser put on the opposite side of the pole? The old one was out of the way.
@azrios
@azrios 2 жыл бұрын
Where is the rubber gloves? Cradle to cradle.
@sthdz2932
@sthdz2932 7 жыл бұрын
What was that small transformer for?
@TheKingbonagua
@TheKingbonagua 6 жыл бұрын
Sergio Hernandez , sir, that's the small P.T. for power supply of the controller. The other one is the C.T. for detecting the fault and other parameters such as the load. Correct me if im wrong.
@fabiodejesuscamargoeletricista
@fabiodejesuscamargoeletricista 4 жыл бұрын
Excelent working conglatulation.
@allezvenga7617
@allezvenga7617 3 жыл бұрын
Thanks for your sharing
@lennys5058
@lennys5058 4 жыл бұрын
I assemble those control boxes
@xCondemnedIV
@xCondemnedIV 2 жыл бұрын
Yeah sure an instructional video but somehow doesn't even mention the bypass switches being closed in on the other side of the recloser to tie the line without dropping load and jumps straight into removing leads lol.
@TheKingbonagua
@TheKingbonagua 6 жыл бұрын
I think they're using the voltage detector and not a ammeter as you said sir. How long it takes the process of changeout?
@linemanap
@linemanap 6 жыл бұрын
No it's a amp meter
@michaeleverest3487
@michaeleverest3487 4 жыл бұрын
There's voltage. What they want to be certain of is that the amperage is zero to ensure no loads are being powered, or if they cut into the cable there would be an arc and potentially kill someone.
@TheBibleListener
@TheBibleListener 4 жыл бұрын
"Strengthened the guy wire" lol!!!! They didnt Strengthened the wire they cut a fiber stick into it to insulate it from the hot wires on the recloser lol just let us watch the vids and mute the narrator
@freethinkingamerican80
@freethinkingamerican80 3 жыл бұрын
I was like "strengthening the guy wire", that's new to me lol 😆
@raulmejia2066
@raulmejia2066 3 жыл бұрын
T & D World. APS. LineMan... Thank you. IBEW...... Thank U.... Raul Mejia O'regel CIty of Suprise. State of Arizona.....I like that girl... Yeahh
How to Change Out a Capacitor Bank
7:01
T&D World
Рет қаралды 62 М.
How to Change Out a Voltage Regulator
9:53
T&D World
Рет қаралды 102 М.
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН
Mom Hack for Cooking Solo with a Little One! 🍳👶
00:15
5-Minute Crafts HOUSE
Рет қаралды 23 МЛН
How to Install the TripSaver II Recloser
6:47
T&D World
Рет қаралды 88 М.
Why aren't all power lines underground?
1:50
Vector Ltd
Рет қаралды 33 М.
Insulator Changeout On H-Structure NLC
11:41
David Wilkins
Рет қаралды 6 МЛН
Up close look at a single phase oil recloser
12:26
Cube Computer Channel
Рет қаралды 916
Primary Conductor Removal
8:27
T&D World
Рет қаралды 79 М.
Fusesaver Installation
6:39
T&D World
Рет қаралды 107 М.
Concrete Pole Framing
6:10
T&D World
Рет қаралды 38 М.
Energized Line Transfer
6:20
T&D World
Рет қаралды 358 М.
LA 511
3:52
FRANCISCO JAVIER ÁNGEL ÁVILA
Рет қаралды 21 М.