Bahut badiya bhai bahut achcha laga apke samjhane ka tarika
@thetechhvac Жыл бұрын
doston air conditioner se related agar aapka koi bhi doubt ho to aap comment karke bata sakte hain...🙏🔔❤
@EMADTECH Жыл бұрын
Please read and answer so that we can make our normal inverter ac into hybrid solar ac Inverter air conditioner nowadays are running smoothly on solar power provided their outdoor and indoor fan is also dc, as some brands install ac induction fan in outdoor unit and make it useless, In panasonic 5 star inverter ac compressor indoor fan outdoor fan swing motor all are dc and 6*550 solar panels run inverter ac whole day 9 pm to 3 pm But in cloudy days there may be some fluctuations To address this Amp fluctuation issue a bridge rectifier circuit can be used in air conditioner plug box on the one end of circuit we will give 220 v ac current and on another end of circuit 220v rectified dc will be produced by bridge rectifier with +v and -v polarity now connect +v of solar panel to + of bridge rectifier and -v of solar panel to -v of bridge rectifier, feedback current can be protected using diods so that solar current not go in ac line and ac rectified dc current dont go back into dc solar line diods should be connected before connecting + + and - - together will do this job, for this we need 6 panels of 550 watts and total voltage should be a little higher than grid supply 6 panels will give around 280 volt dc current while grid usually provides 250 volts now after using this bridge rectifier air conditioner will draw current from solar panel if sufficient ampere not available in solar supply it will take remaining amps from grid we are not touching anything inside air conditioner, this circuit will make our air conditioner an ongrid or hybrid air conditioner which will primarily run on solar power if solar power is available if solar power is not sufficient it will take power from grid no separate connection needed in night time and in case of grid outage and sun availability air conditioner will keep running till sufficient power is generated through solar panels Point to be noted 👉 in above post I used term 220v rectified dc for easier understanding but in reality 220v ac rectified gives peak voltage around 311 volt dc hence to counter this situation and maintain voltage compatibility easiest way to use a 220v to 110v converter on ac current line then do the bridge rectification and we will get around 155 voltage dc best voltage for our system now 4x550watt solar panels will produce around 200 to 190 volt dc bridge rectifier will produce 155 v dc now solar panels output and bridge rectifier output to be connected in parallel with diods protection since device will draw current from high voltage source first it will run on solar panel if solar panel voltage drops or current drops it will take remaining power from bridge rectifier, in the morning time solar panel will provide less amps and and our system will take remaining required amps from bridge rectifier this hybrid system will prevent fluctuations throughout the day and utilise solar+grid in day time and only grid in night time
@jollyscaria19227 ай бұрын
Seakd comprssir teeminal c.s and Rare udenttidiedby measuringtheresistance ohms bet ween ber qeenthe terninals using multimeraror clampmetrtheresisttanceif ruing windingis lowwhile thatof starting widingis gigh whenthw multimetr poeds are conneacted to terinals r c resistance of ruing winding orthe lowestreistance ia indicated when the pords are coneactedto terminals Rand s totalreistance of bothwiding is indicatedwentermuals termial c and s are co tactedto mwtrristens startigqundoifhifh low r c cs poted
@HVAC33106 ай бұрын
3 phase compressor l1 l2 l3 terminal remove ho gya ho to kaise pata karenge ki Kaun sa terminal l1 l2 l3 hai R-L1 , Y-L2, B-L3 ye wiring sequence hai Abhi RYB ko isi sequence me connection dena hota hai nahi to compressor high noise , homming karta hai
@RaeesOsman-h6d Жыл бұрын
Aap ka samja na bahut acha kisi naya elec ko samaj ahayega bahut bahut thank you ❤❤
@aishakhan8623 Жыл бұрын
Buhut accha tarika hai shamjane ka sir
@najjuk7850 Жыл бұрын
Apka tareeka bahut zyada achha hai samjhane ka
@HakeemKhan-tq8sg Жыл бұрын
زبردست 👍👍👍 ماشاءاللہ ❤❤❤ بہت اچھا زبردست بہت عمدہ 👍♥️♥️🌹🌹🌹🥀🌹🥀
@khanjuma7779 ай бұрын
Khoob kiaa baat hai teacher ho app jaisa
@pravinchourasiya97742 ай бұрын
Gajab
@shaikhaqeel449910 ай бұрын
Masah Allah Aap ne buhat accha tech Kiya Allah aap ko traqqi ata farmaye
@thetechhvac10 ай бұрын
🤲💚🤝
@tauhidalam342510 ай бұрын
Bahut Achcha se kam Sikha raha hai
@thetechhvac10 ай бұрын
🤝🤲😍
@Dawoodkhan-zb7tw Жыл бұрын
Sahi hai Boos good job
@singhsingh-ip1sc8 ай бұрын
Very useful video
@NewStatusRazaAli Жыл бұрын
very nice useful video bhai shukriya
@rahamanAnsariAnsari-z8p10 ай бұрын
Bahut badhiya samjhate hai sir
@thetechhvac10 ай бұрын
Thank you so much for your kind words! I'm glad you find my explanations helpful.
@jaychandran37878 ай бұрын
Sirji, u r a good teacher 😊
@mohdalamgir841111 ай бұрын
Bhut badia sa samjhiya ji
@thetechhvac11 ай бұрын
😍❤️🔔.
@hameedabdul60463 ай бұрын
Thanks bro ❤
@Ayemaa-xp4oy5 ай бұрын
Gajab bhai
@MovieWorld3640210 ай бұрын
Good job nice information
@mdhelalahmed22765 ай бұрын
Good work ❤❤
@irfanmirza-xd2cj10 ай бұрын
Very good good good information. Sir
@thetechhvac10 ай бұрын
So nice of you
@villagevlogs27632 ай бұрын
Tq so much bhai
@motinmiya39816 ай бұрын
Nice 👍 masaallah
@AmanKumar-ux7ze6 ай бұрын
Mujhe kam aata h fir bhi maine aapki video dekhi ustad ho to aapki trh
@thetechhvac6 ай бұрын
love you brother 🤝 💚
@javaidmughal6521 Жыл бұрын
❤ very professional
@sohaibazhar4942 Жыл бұрын
Very nice information...thnx a lot
@ehtashamkhan80898 ай бұрын
Sir g ap Great Hain....
@thetechhvac8 ай бұрын
it’s my pleasure 🤝💚
@LifeInformation481GulfDubai5 ай бұрын
ماشاء اللّٰہ
@Ammaar___0611 ай бұрын
Maasha Allah ❤
@awaisad95668 ай бұрын
Ma Sha Allah 🥰
@BrijeshKumar-ik8zl9 ай бұрын
Nice
@FahimArfankhan4 ай бұрын
Thank you
@razvivlogs963 ай бұрын
Bhai inverter AC ke outdoor mein jo bhi system Laga hota hai uske bare mein details mein Bata do ki uski wiring kaise karte hain aur har EK part ko check karna bata do
@prosanjitchakraborty2119Ай бұрын
❤
@Secretjocks Жыл бұрын
Very nice information sir ek video ap ac choking ke upar bhi bana do ki ac ke pure macenical system me kahi bhi choking ho cleamp meter or apne experience ke mutabik kaese pata kare ki ac me chok hai ❤❤❤❤
@thetechhvac Жыл бұрын
done....
@thetechhvac11 ай бұрын
ac choking se related video upload kar di hai ja kar ke aap dekh sakte hain ummeed karta hoon aap ko is video se jaroor kuchh na kuchh sikhne ko melega💚 video link:-kzbin.info/www/bejne/iYu6c4yufppqp6M video link part 2 :-kzbin.info/www/bejne/hWSuhKNsd76XZrMsi=5kehxcwepaFJ5OnC
@mdrakibabadactechnician9 ай бұрын
Like 1k ho gaya vai
@thetechhvac9 ай бұрын
We appreciate each and every like we get!👍🏻🎁
@umarsiddique926510 ай бұрын
Good 😊
@intakhabalam33779 ай бұрын
Good explanation
@thetechhvac9 ай бұрын
Thank you for your feedback!
@dubailifeinteluguindia71994 ай бұрын
Supar
@mohammadnaushad99767 ай бұрын
Masaallah ❤
@Mghosalkar Жыл бұрын
Great sir
@ZainKhan-f5d7j Жыл бұрын
Good 👍
@aslampahadi16398 ай бұрын
Good brother
@AwaisAwaisali-e2w Жыл бұрын
❤❤❤❤so nice ❤
@banshbahadur725810 ай бұрын
Good 👍 sir
@thetechhvac10 ай бұрын
So nice
@technicalshaheed22104 ай бұрын
Bhai jis modal number me last me kce rahega usme R407c gas dale gi kis leye policter oil hi our jis model numbere last me kc rahega toh usme R22 dal sakte hi isme mineral oil hota hai toh oil number sticker per likha raheta hai usko dekh ker dalna padega
@Rashid_Ansari93 Жыл бұрын
Ser common ke saath running lagta hai capacitor men
@thetechhvac Жыл бұрын
Capacitor par Running aur starting lagega Common par direct ek supply jayegi(N)
@Rashid_Ansari93 Жыл бұрын
@@thetechhvac thank you ser
@mohdafzal5961 Жыл бұрын
💯💯💯
@Aamir.Allinone Жыл бұрын
Thanks sir
@smartguy32864 ай бұрын
Compressor low amp per kisay chalai?
@vickysahota73758 ай бұрын
Veer ji. Lloyd ka one ton window AC compressor overheating problem Hai meter per reading 6:24 aa rha Hai Kya Karen
@thetechhvac8 ай бұрын
veeray kai sare reason ho sakte aap in sabhi pointon ko step by step check kar sakte hain . (1). voltage under ya over hona ( rated volt se) (2). capacitor weak hona (3). proper condensing na hona ( condensor coil chocked , condensor fan weak ) (4). refrigerant over charge (5). chocking hona (6). compressor oil over heat ya kam hona (7). compressor faulty.
@mdmahijulshaikh227011 ай бұрын
Sticker ka jo likha wa mitjayega to keise check karenge scorl compressor ke liye 3ph kitna ton Hain
@thetechhvac11 ай бұрын
bahut hi accha sawal hai bhai aapka ye problem aksar technician bhaiyon ko hoti hai ispar ek video aane wali hai bahut jald…⏰
@mdibrahimkholil67036 ай бұрын
Thanks
@thetechhvac6 ай бұрын
Welcome💚
@MovieWorld3640210 ай бұрын
Sir compressor ka overload ka number k bara ma btain ka kis nunmber ha ha
@thetechhvac10 ай бұрын
done..✅
@AtifShokat-rm5yp5 ай бұрын
Wa Boos
@MdShahid-mf3gk7 ай бұрын
Good🇹🇷🇺🇸
@thetechhvac7 ай бұрын
💚🇸🇦
@saudkureshi364811 ай бұрын
Sar rotary comp ka kese pata kare ke kitne tr ka he
@thetechhvac11 ай бұрын
saud bhai agar aapko compressor ka ton pata karna hai to aap model no aur LRA se bhi pata kar sakte hain LRA se pata karne ke liye . takreeben 36 LRA ka 1 ton hota hai model har company ka alag alag hota hai to aap ko thoda sa samajhna padega model se ton kaise pata kare.kzbin.info/www/bejne/g3q9cnqGdpece5Isi=TCRNfAHlZzOPzwlD
@SalamHossan-8 ай бұрын
❤❤❤❤❤
@FaizKhan-sw4nz11 ай бұрын
❤👍
@abhisheksah934711 ай бұрын
❤❤❤❤❤❤
@soumittra7 ай бұрын
Will the compressor of a refrigerator go bad if it is run without any load, such as being empty and without connecting any pipe or loading any gas? If it does go bad, what is the reason for this occurrence?
@thetechhvac7 ай бұрын
Yes! If it runs for a long time without gas. Because the compressor is designed to compress only vapor refrigerant ( not AIR , VACCUME etc..)
@zoibkhilonawala68203 ай бұрын
Compressor short, Kota
@Shareef87338 ай бұрын
Bahi apka Jo video acha laga magar apne Jo calutae Kiya o galth usme zr compress 🗜️ 125÷12= 10.4 are ok usme 12ka sath 00 kohi zarvath nahi
@thetechhvac8 ай бұрын
Ji han aise bhi kar sakte hain aur teen zero laga lenge to bhi kar sakte hain koi galat nahi hai copleland ke jo model hote hain wo do type main hote hain ek “K” main aur ek “M” main ( ZR125K,ZR19M) ab yahan par do model type hain ek K aur ek M To ham K wale main teen zero is wajah se lagayenge kyonki K jo yahan par diya gaya hai wo hajar ko represent kar raha hai is liye koi galat nahi hai aur M ke bare main aur maloom karna hai to watch this video 👉kzbin.info/www/bejne/g3q9cnqGdpece5Isi=dKJ4lYqaEbNmy7g0
@shaikhsabir38285 ай бұрын
Compressor ka 3 terminal continue aata h.3 terminal ke saath body pe touch kiya continue nhi dekhta h.ky reason h compressor nhi chalta h.new capactior lagaya
@thetechhvac5 ай бұрын
kabhi kabhi compressor jaam ho jaate hain jiski wajah se sab kuchh ok hone ke baad bhi compressor on nahi hota hai
@Farba-p5i9 ай бұрын
❤
@thetechhvac9 ай бұрын
💚
@BUTLERENGLISH Жыл бұрын
Agr aisa koi pahle samjaya hota to aaj mai AC ka engineer hota 😢
@thetechhvac Жыл бұрын
koi nahi bro agar aap main koi bhi kaam karne ka junoon hai to aap ko koi nahi rok sakta fir chahe aap ek engineer banna chahen ya fir ek blogger . aap mehnat karte rahiye . sikhte rahiye. aur improve karte rahiye god bless you🤝❤️
@BUTLERENGLISH Жыл бұрын
Thank you ❤ and the best part of this video is the name Ahmad,😂😂😂😂 it's mine name
@md_salman_khan_7860 Жыл бұрын
😂Accha ji
@jimfitneeswork3 ай бұрын
Hello Sar meri detan ki aisi hai aur usmein jo compressor hai vah load jyada le raha hai light jyada Jaise chalti hai aisi to load jyada leta hai sari light kam Ho jaati hai aur FIR cut maar deta hai to Kiya problem hai sar
@koundridinesh5494 Жыл бұрын
Hello sir i want to learn refrigerator and ac work please could you tech me sir i am from Hyderabad sir😊
@thetechhvac Жыл бұрын
Aap mere channel se jude rahiyega aapko aisi hi knowledgeble videos milti rahegi❤️🙏 Aapko jis bhi topic par video chahiye aap hame comment karke bata sakte hain I am from Lucknow 🤝
@malikjani7199 ай бұрын
Bhai mien NY new campresr instal Kiya pressure aur sab cheez theek tha Lekin gass add krny k time 10/15 mint theek chlaa us k bad preshr chor diya to kya msla ho skta Hy plz btaye ga zror
@thetechhvac9 ай бұрын
kis type ka ac hai aur compressor kis type ka ( single phase ,three phase , rotary , scroll…) please full detail den.
@malikjani7199 ай бұрын
Bhai 3ph Hy aur scroll type hy
@malikjani7199 ай бұрын
Ik bar gas Nikal k dubara adhy gnty bad chlaya phir 10 mint sae chla phir wesy hi ho gya is ka neechy waal to ni bnd Lekin mien NY fitar lghny k bad chak Kiya tha preshr sae AA rha tha
@thetechhvac9 ай бұрын
ye mera whatsapp no hai +917897686268
@thetechhvac9 ай бұрын
agar kahin se chocking hogi jaise exp. valve , orifice , capplery dryer filter to bhi ye problem aayega aise kai sare reason ho sakte hain
@crazyhate8 ай бұрын
Sar showing wrong common direct go to life connection running is neutral starting is line I am right tissing me please
@thetechhvac8 ай бұрын
please dobara bata sakte hain main aapka ka massage samajh nahi paya🙏
@suphiyanahamad6 ай бұрын
Sir HVAC ka pdf kha milega
@thetechhvac6 ай бұрын
online amazon se buy kar len .
@Dawoodkhan-zb7tw Жыл бұрын
❤❤❤❤❤👍👍👍👍👍👍💯💯💯💯
@VinodMaurya-v6y Жыл бұрын
Oil ka nhi bataya bhai apne kaise pta kare kitna oil hai compressor mai
@thetechhvac Жыл бұрын
bhai aap ye video dekh len is video main poori information hai. kzbin.info/www/bejne/oYXZiGmehdKMmKMsi=4n1gXpHVrt27x41V
@AbdulAlim-tg3xr11 ай бұрын
Kaha btaye bhai oil ka
@thetechhvac11 ай бұрын
agar compressor main side glaas diya huwa hai to aap use dekh kar pata kar sakte ho ki kitna oil compressor main hai jesa ki kuchh compressor main hota hai lekin agar aap aise compressor main oil check karna chahte ho jisme side glass nahi hai to aap compressor ka sara oil bahar nikal karke check kar sakte hain aur agar oil kam hai to oil add karke oil poora kar len . bas yahi ek tarika hai oil check karne ka . ummed karta hoon aapko samaj main aa gaya hoga ..🤝❤️
@AbdulAlim-tg3xr11 ай бұрын
@@thetechhvac universal pcb indoor wiring p ek video chahiye
@thetechhvac11 ай бұрын
@@AbdulAlim-tg3xr bilkul ji jaroor banayenge...❤
@mithileshyadav5188 Жыл бұрын
Hello sir. Good evening How much max ampere is allowed for 1.5 TR and 2 TR ac compressor for a healthy running otherwise it will be faulty??
@thetechhvac Жыл бұрын
hello . 🤝🙏 .ex.1 cooling capacity of 1.5 ton = 5275 W of power. If the supply voltage is around 220 V AC, then the running current will be 1510/220 = 6.9 A. ex.2. Capacity Current (AMP) Breaker size 0.75 ton 5~6Amp 16 Amp 1.0 ton 6~7Amp 20 Amp 1.5 ton 8~10Amp 32Amp 2 ton 15~16Amp 40Amp NOTE;- ye ek example hai koi fix amp.nahi hota hai . han ye jaroor hai ki "lagbhag " itna hi amp compressor leta hai (kyonki ye depend karta hai ki aap ke system main kon sa compressor laga hai , kon sa refrigerant use huwa hai , kitne star ka hai 3 star ya 5 star ....aur bhi bahut sari baten hai jiski wajah se amp. main thoda sa diffrent ho sakta hai.
@parvezkhanparvezkhan5477 Жыл бұрын
Aap galat bata rahe hai 1.5 ton AC me 6ya7A so hoga
@thetechhvac Жыл бұрын
@@parvezkhanparvezkhan5477 aap se request 🙏hai aap dobara comment dyan se padhe aap ko poori baat samajh main aa jayegi .
@janakiramgudela5460 Жыл бұрын
Hermetic matlab purana Nahin Hai hermetic matlab sealed Jo compresser use karte hain ham log Vahi Shield hai
@thetechhvac Жыл бұрын
Bilkul sahi kaha aap ne lekin yahan main “purana” is wajah se bola hon ki ye “model purana“ hai🤝
@Sonuvlog4526 ай бұрын
Mai apke pass kam karna chahata hu
@NewStatusRazaAli Жыл бұрын
bhai mere miter me contati hold nahi re rahi har baar alag aa rahi hai
@thetechhvac Жыл бұрын
shayad meter ki prob sahi se nahi lagi hongi. ya fir us jagah par carbon jama hoga ...
@saifalikhan913911 ай бұрын
aapne C par N wala wire Laga Diya or R Line to glat hai yeah C pr line or R par Newton
@thetechhvac11 ай бұрын
aisa koi fix nahi hai AC (alternative current) voltage main par aapke suggestion ki main respect karta hoon✅💚
agar mere pass 60 HZ ki supply ho to ? phase to phase 230 volt banta ho to aap kya kahoge ?. ( kuchh country main is type ki power supply hoti hai )
@alisultan11024 ай бұрын
125+000=125000 125000%12000=10.41-1 =9.41
@Anujmishravlogs2.0 Жыл бұрын
Really nhi lagya
@thetechhvac Жыл бұрын
Reley refrigerator ya deep freezer ke compressor main lagta hai Ye compressor Air condition ka hai iske compressor main jyadatar capacitor hi laga hota hai( PSC type ) Pahle aate they aise compressor jo ki hermetic type ke hote they jinme reley lagi hoti thi jisko CSR type connection karna hota tha Abhi rotary type ke compressor main sirf PSC type connection hote hain… Thanks for feedback ❤️